Loading…
Loading…
Tender Value
₹29.4 Cr
EMD Value
₹58.8 L
Closing Date
6 Jul 2026, 3:00 pm
"Design, Supply, Installation, Programming, Testing and Commissioning of New Hot Standby Electronic Interlocking System at Waghodiya , Jarod and Lotna Stations and EI alteration at Dabhoi and Samlaya station along with Supply, Installation, Testing and Commissioning of various Indoor and Outdoor Signaling System with BPAC in Dabhoi-Waghodiya -Jarod - Lotna-Samlaya Section in connection of provision of Gauge Conversion Work under Dy. CSTE Construction, Vadodara, Gujarat (Western Railway)
SnT-C-BRC-154-2026-27
SnT-C-BRC-154-2026-27
Open
12 Days
Vadodara, Gujarat
₹0
₹58.8 L
8 Jun 2026
8 Jun 2026
22 Jun 2026
Item Breakup - A-Supply of Items
Approximate Screen size 55 inch Total 694352.25 Data logger system for Railway S&T installation As per spec. IRS: S-99 2006 (Amdt-3) or latest. Central Monitoring Unit (Hardware Configuration as per Annexure) with UPS minimum 06 hrs Item- 11 battery backup and required Software tools. This also includes the supply of one no composite computer & printer table (Godrej workstation table) for keeping the Processor module and one no Godrej make operator chair model PCH7001. S No. Item Description of Item Unit Qty Rate Amount No
1024 digital and 32 analog inputs. Total 2460108.25 Item- 17 Supply Color Light Signal Accessories. S No. Item Description of Item Unit Qty Rate Amount No DYCSTE-C-BRC-S AND T/WESTERN RLY
(1) CI Base (As per IRS S-10 & RDSO Drg. No. Set 2011/M With latest assembly). (2) Pinnacle. (3) Ladder Assembly, as per RDSO Drg. No. S A - 2 3 1 5 6 , w i t h B a s e , Ladder Guards, Platform, Fr o n t Maintenance Platform, MS Supporting bracket t o Suppo rt Ladder.(4) Signal Front Staging Complete Assembly for CLS Unit.(5) Signal back staging as per extent WR Practice.
Supply of signal no plate as per Drg no CSTE Numbers Drg No CSTE/6186. Total 296555.65 Item- 30 Supply of DC Track Circuit Accessories as follows - S No. Item Description of Item Unit Qty Rate Amount No
Track feed battery chargers, 110V AC input, Numbers 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery.
Choke Coil for Single Rail Track Circuit on 25 Numbers KV 50 Hz AC Electrified Section a s per Spec No IRS S 65/1983 with latest amendments.
L o w maintenance Lea d acid secondary cell Numbers 2 V / 8 0 AH (Track feed B a t t e r y ) , shelf mounting type conforming to IRS:S- 88/2004 or latest (uncharged).
Adjustable Track Feed Resistance disc type Numbers 30 ohms as per RDSO Drg. No. S A 20166/M (Adv.) with latest amendments (with Phenolic molded base). Total 2465158.60 Disconnect Terminal Block, Screw less type, as per RDSO Spec. No.RDSO/SPN/189/2004. With the Item- 52 latest amendments. S No. Item Description of Item Unit Qty Rate Amount No
Disconnect Terminal Block, Screw less type, Numbers 30000.00 4-wire front entry (Two in-put & Two out-put) The color will be decided b y Engineer - in - Charge. (Preferably I n Blue, Red & Grey Colors i n t h e ratio o f 1:2:3). as per RDSO Spec. N o . RDSO/SPN/189/2004. W i t h latest amendments.Note- Make to be approved by Railway before supply.
Supply of End plate 2.5mm/0.091 i n thick as Numbers per site requirement.
Supply of End Stopper 10mm/0.0394 in width Numbers as per site requirement.
Supply o f Carrier Rails f o r above 3 5 m m x Numbers 7.5mm, 1mm/0.039 i n thickness un-slotted type as per site requirement. Total 1657633.20 Microcontroller based programmable static switching module (Auto changeover) of Reliance Item- 77 Electricals Make or similar, with an at a glance LCD display suitable for break-less switching between two DC supplies as per attached technical specifications. S No. Item Description of Item Unit Qty Rate Amount No
Upto 40A for 20-110VDC. Model No: RE- Numbers SDSM-40.
Upto 70A for 20-110VDC. Model No: RE- Numbers SDSM-70.
Upto 40A for 110VAC. Model No: RE-SASM- Numbers 40. Total 3648235.50
Item Breakup - B-Execution items
Per Alteration more than 20 routes. Route Total 33100225.40 Item- 2 Design of ST/LT/TOC/Square sheet/RCC (Three copy) for approval. S No. Item Description of Item Unit Qty Rate Amount No
Upto four line station Total 54046.47 Installation, wiring, programming, testing and commissioning of EI equipment supplied as per supply item in schedule 'A' including transportation from Consignee's depot to site. The works and materials for installation, wiring, testing and commissioning, grouting, cutting of floors, walls, refilling of the same, re-plastering, required CC/ masonry works, fixing/ placing/ laying of insulated ladders/ casing-capping/ cable trays/ RCC/GI pipes / Cables, termination of cables with lugs/ connectors, painting, / lettering are to be provided/ done by the contractor for the equipments supplied vide Item of Schedule "A" of this contract. This also covers the networking of built in EI Data loggers of all the stations to monitor the system to any other places where desired by Engineer-in-charge. Note: Installation shall be comply with RDSO Technical Advisory Note No STE/E/TAN/3012 dtd. 28.08.2014 or latest. Installation, wiring, programming, testing and commissioning of Operator VDU in Hot stand-by with Redundancy. Any Equipments/cards/Modules required for Hot stand-by with Redundancy shall be supplied & Installed by the Contractor. This also include supply of one no Godrej make operator chair model PCH7001 or better , one no. of Item- 4 composite computer & printer table (Godrej work station table or better) for keeping MT , one no Godrej make operator chair model PCH7001 or better. Termination of indoor/ PIJF cables in relay room on relays, tag blocks, CT racks as per approved wiring diagram including alterations/ modifications as required at site. Soldering to be done at all required termination. Dressing/ lacing of wiring shall be done neatly with help of dressing thread / plastic self-lock strip of suitable size. The tools/ equipments/ materials/ simulation boards required for testing shall be supplied / fabricated by contactor. This included replacement of modules/ cards/ LEDs/ equipments going defective during testing. Necessary power supply boards with required capacity plugs, sockets, surge & lightning protection boxes shall be supplied and installed by the contractor. 230V supply shall be arranged by Railways. In case supplies are required to be extended, from Power room / relay room then same shall be extended by the contractor with his own materials such as 1X16 sq. mm wires, cables, lugs,RCC/GI pipes, insulated ladders etc. After ST/LT testing, Factory Acceptance Tests (FAT) & Square Sheet testing system should be fault free while submitting to Railways, otherwise suitable necessary action can be taken by Engineer-in-charge. S No. Item Description of Item Unit Qty Rate Amount No
without Object Controller Total 2862966.39 Design of Circuit Diagrams consisting Wiring/ Logic diagram, contact analysis, fuse detail, Item- 5 Input/output bit chart, VDU diagram, Interface etc. submission of Three paper copies for approval. S No. Item Description of Item Unit Qty Rate Amount No
50 to 100 Routes Total 833331.63 Design of Miscellaneous diagram consist of Floor Plan of Relay Room, Battery Room, Power Equipment Room, Data logger room, Power Supply Diagrams along with power supply calculation, Item- 6 Earthing Diagram, Power panel diagram, IPS wiring diagram , Auto change over diagram , Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings (Three copy) for approval. S No. Item Description of Item Unit Qty Rate Amount No DYCSTE-C-BRC-S AND T/WESTERN RLY
More than four line station Total 30907.36 Supply of Circuit Diagrams consisting wiring/Logic diagram, contact analysis, fuse detail, Item- 8 Input/output bit chart, VDU diagram, Interface in Auto CAD in Pen Drive and Six set of Copies after approval. S No. Item Description of Item Unit Qty Rate Amount No
Upto four line station
More than four line station Total 154630.87 Supply of diagrams consist of Floor Plan of Relay Room, Battery Room, Power Equipment Room, Data logger room, Power Supply Diagrams along with power supply calculation, Earthing Diagram, Item- 9 Power panel diagram, IPS wiring diagram, Auto change over diagram, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawing in original tracing along with AutoCAD in Pen Drive and six set copies after approval. S No. Item Description of Item Unit Qty Rate Amount No
Upto four line station
More than four line station Total 21543.75 Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD in A3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly Item- 11 approved withalterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards. S No. Item Description of Item Unit Qty Rate Amount No
Station Total 303361.75 Design and supply SWR Diagram on standard tracing paper of 95grams for each station. Corrected Item- 12 version of SWR plans after checked & approved by Rly's 25 Ferro copies will be supply for each of the plans. S No. Item Description of Item Unit Qty Rate Amount No
For stations having up to 4 lines
More than four line station Total 211705.84 Item- 13 Preparation of SWR including supply of SWR booklets (25 Nos. per station). S No. Item Description of Item Unit Qty Rate Amount No
For stations having up to 4 lines
For stations having more than 4 lines Total 291649.10 "Preparation of Cable Route Plan of buried S & T Cables using Radio Detector 8200 GS or Similar Item- 14 model GPS Model and DGPS for Per Trench per Km. For existing cables as per the instruction of Engineer in-charge. Submission of report in KMZ file format, Soft Copy Only." S No. Item Description of Item Unit Qty Rate Amount No
In Yard Section Total 617071.44 Item- 16 Foundation, Erection & Installation of CLS without route indicator. S No. Item Description of Item Unit Qty Rate Amount No DYCSTE-C-BRC-S AND T/WESTERN RLY
Excavation a n d Casting o f foundation for Numbers main signal post as per CSTE/3122 (WR) with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost.
Erection of CLS Post with base and signal Numbers unit on top or on OFF set Bracket, fixing of front a n d bac k staging, ladder a n d guards w i t h contractor's o w n brackets and fixing materials. T h i s a l s o includes erection of auxiliary signals like calling on, shunt signal if a n y . T h e work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing o f maintenance platform as per design given by Engineer -In- Charge at site. I t a l s o includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor t i l l t h e signals a r e introduced. T h e Item includes cutting of Signal post if required by S i t e In c h a r g e . 2 / 3 / 4 a s p e c t s i g n a l unit mounted directly on signal post. Total 1413886.63 Item- 19 Foundation, Erection & Installation of Shunt Signal. S No. Item Description of Item Unit Qty Rate Amount No
Excavation and Casting of foundation for Numbers Shunt Signal as per Drg. No. CSTE/6090 with Contractor's own materials including Cement a n d A n c h o r B o l t s o f Standard Size. The required scaffolding, Ferma etc. for Casting of foundation w ill hav e t o b e brought b y the Contractor at his own cost.
Erection o f Position Light Shunt signal with Numbers Base, Post, and Signal unit. Wiring & Fixing of Number Plate .The work shall be done as per instructions of Rly engineer at site. Total 330577.17 Item- 25 Provision of Field accessories of DC Track Circuits S No. Item Description of Item Unit Qty Rate Amount No
Track Lead Junction Boxes a s per C.Rly Drg. Numbers No.RST 11509 m a d e f r o m fiber glass/SMC/FRP along with terminal blocks.
G I wire 8 SWG (4mm Dia) suitable f o r track Kg circuit rail bonding.
Channel Pins M S (Galvanized) single groove, Numbers 7 mm suitable for 4mm Dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. Total 783842.20 "Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Item- 38 Epoxy paint will be supplied by Railways. NOTE-The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974)." S No. Item Description of Item Unit Qty Rate Amount No
Main Signal Post w ith Signal Units, Surface Numbers base and complete fittings a s p e r Western Railways standard practice.
Shunt signal post w ith signal unit, surface Numbers b a s e a s per Western Railway's Standard Practice. DYCSTE-C-BRC-S AND T/WESTERN RLY
Track Lead Junction Box. (Black enamel Numbers outside only).
Point Machine with ground connections Numbers complete (Point Machine with Black enamel o n l y outside a n d ground connections with Red Oxide). Total 82806.71 Excavation and Casting of Apparatus Case foundation with contractor's own materials including Item- 45 cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost. S No. Item Description of Item Unit Qty Rate Amount No
Single Case as per Drg No SK 748 or Numbers CSTE/5074 or SS Location
Half Case as per Drg No SK 747or CSTE/5074 Numbers or SS Location. Total 2588215.30 Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of Item- 46 location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. S No. Item Description of Item Unit Qty Rate Amount No
Half Case Total 370751.50 Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own Item- 48 materials. The work shall be done as per Drg and arrangement similar to SK 783-1/2. With latest alterations & as per instructions of Rly engineer at site. Note- SMC sheet will be taken in place of phenolic laminated sheet. S No. Item Description of Item Unit Qty Rate Amount No
Half Case Total 764769.70 Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Item- 49 Epoxy paint will be supplied by Railways. NOTE-The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974). S No. Item Description of Item Unit Qty Rate Amount No
Apparatus Case Full Size. (Outside & inside)
Apparatus case Half Size. (Outside & inside) Total 100870.05 Installation, Wiring and testing of Integrated Power Supply System. This includes power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 8mm thick SMC sheets or any standard make with connections suitable for 32 A. Wiring to be done considering site requirement, depending upon the load with suitable wires, lugs & glands as per instructions of Engineer-in- Item- 64 charge. The work includes installation of ELD's, fixing & wiring of change over switch(program switch) for selection of DG set supply (DG1 & DG2) and wiring of change over switch (program switch) for selection of mains or DG supply. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room etc. Any masonry work required will be carried out by contactors own material. S No. Item Description of Item Unit Qty Rate Amount No
For Station Total 519181.35 Supply, Installation, Testing and Commiioning of fire alarm system as per RDSO spec. No. Item- 67 RDSO/SPN/217/2021 version 2 or latest. DYCSTE-C-BRC-S AND T/WESTERN RLY S No. Item Description of Item Unit Qty Rate Amount No
Power supply Unit 24VDC, 5 Amps, with two Numbers batteries.
Control Module to address sounder cum Set strobe.
Relay module to connect the Data logger to Numbers the panel.
Zone Interface module.
Cable EOL.(1 Nos =30m)
Aspirating type (air sampling) for relay room Numbers with inbuilt fault isolator.
Copper pipe with 25mm Dia and 1mm Numbers thickness.
U L / E N / F M / V D S / L P C B approved Numbers Microprocessor based Networkable Analog addressable and modular type of Fire Alarm Control panel with display, i n built changing facility and provision of GSM module suitable to send SMS to configured mobile numbers.
Resettable, addressable multisensory (heat Numbers and smoke) which is fully compatible with analogue addressable protocol, electronically addressed.
Analogue Addressable, resettable Manual Numbers Call point with inbuilt integral short circuit isolator having status LED for alarming & standby mode, Electronically addressed.
Analogue type Linear heat sensing (LHS) Numbers Cable.
Liner heat sensing (LHS) interface module. Numbers (01 Number = 1 Meter)
Addressable l o o p powdered sounde r cum Each Strobe with inbuilt fault isolator. Module
Hooter cum Strobe. Total 5342687.08 Supply and Installation of Solar Power system for 110volt/300AH battery bank load as IPS System. Item- 71 Each panel containing the following items. S No. Item Description of Item Unit Qty Rate Amount No
i. commissioning of Solar photovoltaic Module as per IRS: S:84/92 (Amendment -2) or latest, 12Volt-80 Watt Peak, 72 Nos. in each set) series & parallel combinations (Preferably 9 series X 8 Parallel) will be as per site requirements & instruction of Engineer-in- Charge.
ii. commissioning of charge controller of 110V, 60 Amp. compatible with solar panel installed with digital meter. The charger controller should have provision of over voltage protection and low voltage protection , Blocking Diode fitted in the charge controller unit as per RDSO/SPN/187/2004 Amnd-1 or latest
iii. commissioning of Array junction Box (02 Nos par set) & Main junction Box (01 No par set) fited with MOV's etc. to safeguard the system from surges and suitable for above item as per instruction of Engineer-in-Charge. DYCSTE-C-BRC-S AND T/WESTERN RLY
iv. Supply , installation , testing and Set commissioning of theft proof mounting frame of angle iron MS Galvanized with adequate strength & weather -proof for solar panel (4- Module & 5- Module strructure ) as with suitable tilting arrangement to be fixed on roof top of building or any other location as per approvde drawing and as per instruction of Engineer in charge. In addition to holes provided for fixing on the mounting structure, extra holes are to be provided suitably in the frame for cable routing. 1 No/ Set Installation must have porper earth terminals and shall be porperly earthed as per instrucion of Engineer in charge.
v. Supply, and installation, of power cables Set with conduit pipes and grouting bolts/Hardware. This includes 1X2.5 sq. mm (minimum 50 mtr) , 2X2.5 sq.mm (minimum 250 mtr) for series and parallel connection of module. 2X10sq mm (minimum 200 mtr), copper cable of RDSO approved supplier between junction charge controllers.
vi. commissioning of Earthing kit for solar Panel system. (1 No./set) as per instruction of Engineer-in-Charge. Total 1928973.84 Shifting & Termination of Signaling cables in S&T gears. It involves disconnection of Old main cable Item- 78 and connection of new main cable (during shifting /NI/Pre-NI). S No. Item Description of Item Unit Qty Rate Amount No
Point Total 136800.00 Earthing of armour of quad cables on copper busbar for three layer earthing of quad cables , it Item- 86 included copper strip green earth wire from quad cable armory to copper strip and green earth wire from copper strip to earth rod along with suitable termination material and soldering S No. Item Description of Item Unit Qty Rate Amount No
Half location box
Full location box Total 1277500.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
tenderdocumnet1.pdf
ATTACHMENT
DB_GC_MYG-DB-SMLA_V6-
ATTACHMENT
SIP WGR
ATTACHMENT
1408-2025-V1-R0-A0-SSE-C- SIP JD
ATTACHMENT
SIP-SMLA.pdf
ATTACHMENT
SIP-LOTNALTN.pdf
ATTACHMENT
07BRC-SC-YRD-SIP-DB_GC_MYG-DB-SMLA_V6-Correctedon05.05.2025.pdf
ATTACHMENT
GMW-WR-SIPS-CONWR-WGR-862-2025-V1-R0-A0-SSE-C-SIG-DRG-VIII-CCG-PDF.pdf2.pdf
ATTACHMENT
GMW-WR-SIPS-CONWR-JD-1408-2025-V1-R0-A0-SSE-C-SIG-DRG-VIII-CCG-PDF.pdf.pdf
ATTACHMENT
Download all tender documents and submit your bid