Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC 11 26 BHAGWANPURA KISHANGARH CHANDIGARH | L1 | Accepted-AOC AOC | |
| 2 | L2₹26.5 L+₹22,141 (0.84%)Rejected-Finance 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L2 | Rejected-Finance Highest | |
| 3 | L3₹28.4 L+₹2.2 L (8.21%)Rejected-Finance SCO 529 3RD FLOOR KESHO RAM COMPLEX SECTOR 4 C CHANDIGARH 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | L3 | Rejected-Finance Highest | |
| 4 | Rejected-Technical TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | - | Rejected-Technical non responsive |
Tender Value
₹25.9 L
EMD Value
₹51,720
Closing Date
17 Oct 2023, 5:00 pmClosed
NAVEEN RATHEE
ED - Ambala
Establishment of Civil Enclave at Ambala for Commencement of Flight Operations under RCS Scheme in Ambala District (Pdg. Fire Alarm System, LAN and EPABX system and Information Display system.
2023_HRY_317171_1
202383859338 EA8E 481B 9357 24112E94F705663BAR
Open Tender
Civil Works
Works
180 days
Ambala Cantt
Establishment of Civil Enclave at Ambala for Commencement of Flight Operations under RCS Scheme in Ambala District (Pdg. Fire Alarm System, LAN and EPABX system and Information Display system.
2 documents required · 2 mandatory
₹5,000
₹51,720
Yes
8 Jan 2024
4 Oct 2023
18 Oct 2023
4 Oct 2023
17 Oct 2023
4 Oct 2023
Amount
[2.EL003] EL003. 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of required loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. The panel should also have IP30 or better protection. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. Make: Morley ZX5SE,Bosch Avenar 2000, Siemens Cereberus EN.
SITC of addressable multi sensor smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements: Drift Compensation feature and Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Morley HM/PTSE/I plus MI/B501AP/IV ,Bosch FAP-425-OT plus MS400B,Siemens OH720 plus DB721
SITC. of Addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector). (Make: Morley HM/RHSE/I plus MI/B501AP/IV, Bosch FAH-425-T plus MS400B, Siemens HI720 plus DB 721).
SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make : Morley HM/MCP/Glass, Bosch FMC-210- DM-G-R, Siemens FDM22.
SITC of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Make: Morley WSO-PR-N05,Bosch FNM-420, Siemens
SITC of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in-Charge of work. Make Pearl/ Giolite/OMEX.
SITC of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make : Morley MI/DCMO,Bosch FLM-420-RLV1-E, Siemens FDCIO221
SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make : (Morley MI DMMI, Bosch FLM-420-O1I1-E,Siemens
SITC of Cabinet and Ceiling Speaker Max Power - 9 W ,Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedance - 1667 Make /BOSCH/ Siemens/Honeywell
SITC of PVC unsheathed copper size 1.5 sq mm 2 core PVC unsheathed s/c stranded ( ISI marked ) copper contuvtor cable 1100v grade in existing pipe excluding cost and erection of pipe but including connection etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer – in charge of work MAKE FINOLEX/POLYCAB/Plaza.
Supply and erection of ABC Dry power type fire Extinguishers of 5 kg. capacity FIRE EXTINGUISHERS duly hang on wall with necessary hook complete in all respect (Make: Safex/Minimax/ Ceasefire)
Supply and erection of Co2 type fire extinguishers of 4 Kg capacity FIRE EXTINGUISHERS duly hang on wall with necessary hook complete in all respect (Make: Safex/Minimax/ Ceasefire)
Supply,Erection testing and Commissioning of UTP cat 6 information outlet( RED - for Data - User End) complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- RandM,Siemon,Systimax,D-link
Supply,Erection testing and Commissioning of UTP Face plate(Single/dual) complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- RandM,Siemon,Systimax,D-link
Supply,Erection testing and Commissioning of 3 FT lenth UTP cat 6 Mounting Patch Cords Low smoke zero helogene (LSZH/LS0H )complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- RandM,Siemon,Systimax,D-link
Supply,Erection testing and Commissioning of 7 FT lenth UTP cat 6 Mounting Patch Cords Low smoke zero helogene (LSZH/LS0H )complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- RandM,Siemon,Systimax,D-link
SETC of 24-port 19` 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19` 1U straight Patch Panel, 24-port, Should have integral cable management Metal shelf,Should accept Shielded as well as Unshielded jacks which should be toolless termination. Should have rear cable management shelf metallic powder coated. Make: (RandM,Siemon,Systimax,D-link)
Supply,Erection testing and Commissioning of Edge Switch 24 Port 10/100/1000 plus 4 SFP Layer 2 manageble Base T Manageble auto sense, Ethernet switch complete in all respect up to the entire satisfaction of Engineer-in charge of work . Make:CISCO /Allied /Juiper/D-link
Supply, Erection, testing and commissioning of 1KVA on line UPS with 3 nos 17 AH 12V along with batteries stand comple in all respect. Make:-APC/DELTA/VERTIV/EMERSON/Microtek
Supply, Erection, testing and commissioning of Non Blocking 32 Bit microprocessor / micro controller based on Stored Program Control Technique. Microprocessor EPABX system expandable up to 48 ports and system components as per specifications / features:- EPABX. system should be configured for: 04 Trunk Lines, 04 Digital Extensions,16 Analog Extensions - Preference would be given to the manufacturer having DSIR recognized RandD. - System should have a system memory of minimum 600 names and number. - System should support CLI on internal and extrernal without any gateway -_ System should support flexible extension Configuration.- System should support Least Cost Routing- System should have DISA (Direct inward Station Access) and DOSA (Direct outward Station Access) facility without consuming any port of the system. - Hunting facility should be inbuilt in the exchange- System should support multi party conferencing Make - AVAYA/UNIFY/ MATRIX/ALCATEL
SITC of Operator Console : SITC of Digital DSS having 32 Direct Keys compatible with the PBX and its console.With option to add multiple DSS with the console. Phone Features Message wait Lamp, Ringer Lamp. Make : Avaya/Unify/Matrix/ALCATEL
SITC of Digital Phonee with large Backlit Display of 240x60 Pixels Graphic LCD, 4 Context Sensitive Keys,Built-in 16 DSS Keys,High Quality Full Duplex Speaker Phone Features Call Forward,Waiting,Transfer,Hold,Conference,Redial, Ringer Lamp.Must have storage for minimum 20 calls per call log in the console itself. Make : Avaya/Unify/Matrix/ALCATEL
Supply, Erection, testing and commissioning of Push Button Telephone Desktop model CLI, flash , redial ,mic with speaker complete in all respect. Make :-Beetel
S/E of 20 Pair IDF/MDF with Krone Make module on Krone Make MS Box duly painted and having lock facilitis
Supply and Laying of 2 Pair multicore Telephone cable conductor size 0.51mm bright annealed copper conductor PVC insulated and shealed in existing pipe / Channel etc. (excluding the cost and laying of pipe / channel) and making necessary connection complete in all respect . Make:- Delton / Shalimar / Polycap/Phenolex.
Supply Installation Testing and Commissioning of 65` FHD(1920 X 1080) resolution Android LED display with built in 2.4 Ghz Wifi, 1.1 Ghz Built in Quad core processor, 1.5 GB DDR3 RAM, 8 GB Memory, built in Double Core Mali 600 MHz GPU, with HDR 10, Dolby Audio, Built in Wifi and Cromecast, Built in web browser, HDMI CEC, HDMI ARC, Built-in Bluetooth Ver.4, 20W built in speakers, HDMI 2.0 X 2, AV X 1, USB 2.0 X 1, RJ45 X 1, Headphone Out x 1, SPDIF Out x 1, Make: Panasonic/Christie/Sony
Supply Installation Testing and Commissioning of Digital signage media player : CPU Octa-core amlogic S912 ARM Cortex-A53, GPU/ Graphics Mali T-820 MP3 OpenGL ES 3.2, OS Android 6.0.1, Memory 2GB DDR3, Storage 32 GB, Wi Fi 802.11/b/g/m with 2dB antena, Ethernet 10/100 Mbps, Bluetooth 4.0, O/P Ports HDMI 2.0,USB 2 USB 2.0 ports , SD SD card slot, support up to 32 GB, Resolution 3840 x 2160. Make: Extreme Media / 3M / Panasonic
SITC of PC Client Intel i7 processor (for workstation) with clock speed- minimum 3.0GHz, RAM8 GB and Expandable. Window 10 or Window 2016 Server Edition .Minimum 1TB (For Workstations)With Read and Write functions . LAN Interface 10/100/1000 Mbps Ethernet. PCI express graphics card 4GB Mouse Optical . USB port at front Dual and dual monitor support. Make: HP, Dell, Lenovo.
Supply Installation Testing and Commissioning of Server software for digital signage. Make: Extreme Media / 3M / Panasonic /SCALA
Supply and laying of 1.5 m HDMI cable. Make: Kramer/Extron/AWM
Supply Installation Testing and Commissioning of 8 port non POE switch. Make: D-link/Digilink/Netgear
Spply erection testing and commissioning of CAT 6 UTP Cable.Transmission frequency of 250 MHz (Minimum),cable Should be 4 pair and Cable should be jacket FR PVC Lbp 69% required with certification report. Make: Panduit/RandM/Systimax)
SITC of 3 Core 1.5 Sqmm Power Cable Make : Havells, Polycab, Finolex.
Insat Techno Services
Hytek Communications and Networking
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .