Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.2 LAccepted-AOC 19 PAOTA C IIIRD ROAD JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Being lowest and acceptable | |
| 2 | L2₹65.9 L+₹5.0 L (8.13%)Rejected-Finance 112 AMBALA ROAD NARAINGARH AMBALA 134203 | NARAINGARH | AMBALA | HARYANA | 134203 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹66.1 L+₹5.2 L (8.55%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹66.5 L+₹5.6 L (9.20%)Rejected-Finance OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹66.8 L+₹5.9 L (9.67%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
Tender Value
₹77.1 L
EMD Value
₹1.4 L
Closing Date
4 Jun 2024, 6:00 pmClosed
CWE AF JODHPUR
HQ CWE AF JODHPUR 342011 Rajasthan
CERTAIN REPAIR TO INTERNAL ELECTRIFICATION AND MISC B/R SERVICES TO THE BLDGS 31 SQN COMPLEX, SIMULATOR COMPLEX, NGHAS ANNEXE AND CHARLIE COMPLEX AT AF STATION JODHPUR
2024_MES_652704_1
88039/E8
Open Tender
Civil Works
Item Rate
90 days
GE AF JODHPUR
As per NIT
8 documents required · 8 mandatory
₹1,000
GE AF Jodhpur
₹1.4 L
Yes
16 Jul 2024
7 May 2024
6 Jun 2024
7 May 2024
4 Jun 2024
21 May 2024
Amount
M&L for point wiring in replacement using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No drawn through and including PVC concealed conduit of 20 mm bore with accessories in wall floor etc ISI marked, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly,including GI sunken box of 1.8 mm thickness for modular plates including modular plate of suitable module including making good of disturbed surface of cement plaster, whitewash/ distempered match with original colour complete all as specified and directed by Engineer-in-charge for the followings:- (a) one light/ fan/Exhaust fan point controlled by one switch.
(b) All as per item No 1 above but One 3 pin 5 amps socket outlet on independent board with other switches.
(c) All as per item No 1 above but for one 3 pin 5 amps socket outlet on the same board with other switches.
(e) All as per item No 1 above but with 2.5 Sq mm copper conductor multistraned pvcinsulated and unshethed cable for Independent one 3 pin 15 Amps socket outlet In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire.
M&L for point wiring in replacement using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area , single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and inciuding medium grade, PVC casing caping and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box of 1.8 mm thick and 60 mm deep (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for (a) one light/ fan/Exhaust fan point controlled by one switch
(b) All as per srl item 5 above but for one 5 pin 5 amps socket outlet on the independent board.
(c) All as per item No 5 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
(d) All as per item No 5 above but with with 2.5 Sq mm cable for Independent one 3 pin 15 Amps socket outlet In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire.
S&F switch piano 5 amps flush type single pole one way
S&F switch piano 16 amps flush type single pole one way
S&F socket outlet flush type 3 pin 5 amps
S&F socket outlet 2 in 1, 5 pin 16 amps flush type
S&F modular switches 6 amps single pole one way
S&F modular socketes out let 6 amps 5 pin combine 2 Module.
S&F modular switches 16 A single pole one way, 1 Module.
S&F modular socket 6-16 A 2/3 pin combined 2 Module.
Supply and fixing Fan step regulator, 120W - 2 module
Supply and fixing Steped type elecrtonic fan regulator flash type on the existing phenolic laminated sheet etc suitable for 240 volt.
Supply & fix in repairs fan down rod of size 3 ft long' made out of 15mm bore duly powder coated GI pipe long complete all as specified and directed
S & F in repairs modular gang box for modular switches,3 module.
S & F in repairs modular gang box for modular switches,6 module.
Taking down carefully copper/aluminium point wiring light ,fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
Supply and fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A,230V, 2P+earth.Complete all as specified and directed by Engineer-in-Charge.
S&F sub main wiring with multistranded FRLS copper conductors 1100 volt grade IS- 694 marked drawn through and including in steel conduit pipe medium grade ISI marked (not less than 20 mm dia)along with fittings and accessories all fixed on wall and surface on ceiling and also including the specified runs of specified size earth continuity conductor of similar type of cable complete all as specified and directed by Engineer in charge. (2 runs of main cable one run of earth wire one run of steel pipe will be measured as an one run) (a) 2 Run of 2.5 Sqmm cable and one run of 2.5 sqmm cable for earth wire.
Material & labour in replacement for sub main wiring with multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC surface conduit pipe medium grade ISI marked (not less than 20 mm dia)along with fittings and accessories all on wall and surface on ceiling and also including the specified runs of specified size earth continuity conductor complete including taking down existing sub main wiring all as specified and directed by Engineer in charge. (2 runs of main cable one run of earth wire one run of PVC pipe will be measured as an one run) (a) 2 Run of 4.0 Sqmm cable and one run of 4.0 sqmm cable for earth wire.
All as per Item No 18 but 2 Run of 6 Sqmm cable and one run of 6 sqmm cable for earth wire
Material & labour in replacement for sub main wiring with multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC surface conduit pipe medium grade ISI marked (not less than 20 mm dia)along with fittings and accessories all on wall and surface on ceiling and also including the specified runs of specified size earth continuity conductor complete including taking down existing sub main wiring all as specified and directed by Engineer in charge. (2 runs of main cable one run of earth wire one run of PVC pipe will be measured as an one run) (a) 4 Run of 10.0 Sqmm cable and two run of 6.0 sqmm cable for earth wire.
S&F and testing in replacement of MCB DB TPN 4 way 240 volt with double door, IP - 43 protection system with having 200 Amps 2 Nos bus bar for neutral bar and earth bus bar fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
Material & labour in replaceemnt for vertical MCB DB TPN 4 Way,IP 43 with 200 amps rated busbar 415 volts suitable for TPN MCCB as incomer,double door with magnetic locking system all as specified.
Supply & fixing in repairs MCCB 125 Amps, 3 Pole,415V 16 KA Complete all as specified and directed.
S&F replacement including unservicable MCB 40 to 100 Amps TPN 10 KA,415 V 'C' Series
S&F in repairs MCB 6 to 32 Amps SP ,240 V ,10 KA 'C' curve,IP 20 complete all as specified and directed.
S&F in repairs MCB 40 to 63 Amps SPN ,240 V C curve 10 KA,IP 20 complete all as specified and directed.
Supply and fixing in repairs ceiling rose,surface type polycarbonate ,isolated body 65 mm 3 terminals (isi marked) complete all as specified and directed.
S&F and testing in replacement of MCB DB SPN 8 way 240 volt with double door, IP - 43 protection system with having 200 Amps 2 Nos bus bar for neutral bar and earth bus bar fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
Supply and fixing in repairs LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
M&L in repairs for in earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m deep below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete including taking out existing earthing all as specified and directed. Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply and fixing in repairs of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing in repairs LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply & fix in repairs Building Security light luminaire LED 22 W 600K,IP-65 with asthetically designed sheet aluminium housing and UV stabilised acrylic cover complete with lamp and internal connection including bracket made of 40 mm dia GI pipe light grade 1.5 m length fixed with MS clamp of suitable size grouted on wall with suitable nos of screws/bolts/nuts etc complete all as specified and directed.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 240V including MCB 20 amps.
S& F Iin replacement of LED flood light 150 watt 230V AC outdoor type with thermal management in AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and necessary cable connctions complete as directed
Supply and fixing in replacement 1100 volt grade heavy duty cable PVC insulated Al conductor screwed with inner seathing of PVC tape and over all PVC sheathed twin core cable flat circulator 6 sqmm solid conductor through suitable size PVC conduit including fixing saddles on wall/roof complete all as specified and directed by Engineer in Charge.
Supply and fixing in replacement 1100 volt grade heavy duty cable PVC insulated Al conductor screwed with inner seathing of PVC tape and over all PVC sheathed twin core cable flat circulator 10 sqmm solid conductor through suitable size PVC conduit including fixing saddles on wall/roof complete all as specified and directed by Engineer in Charge.
Taking down MCB DB any type any size.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 35 sq mm 3½ core.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts/stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed.
M&L for Sand cusioning for cable with screened & washed sand & punning to provide a required cover complete all as specified and directed.
Material and labour for stone slab/patti, 40 to 50mm thick, rough dressed, Jodhpur stone slab cover in trenches for protection of cables, 25cm to 35cm wide and 80 cm long, laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
S & F LT feeder pillar (kiosk) of suitable made out of 3 mm thick CRCA sheet duly powder coated outdoor type double door with openable front door including locking arrangement with copper busbar 250 Amps rating with MCCB 160 Amps 4 pole 16 KA thermal magnetic adjustable type for incoming and fixed on angle iron frame and PCC plinth complete as directed.
M & L for earthing complete with GI earth plate electrode 60cmX60cmX6mm thick,buried directly in ground(earth pit not less than 2.25metres deep below ground level) with top edge of the platenot less than 1.5 m below ground level,connected to and including GI earth strip 32*6 mm by means of nuts,bolts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber,precast RCC cover 50mm thick in cement concrete 1:2:4 type B1,reinforced with welded steel wire fabric or XPM (weight not less than 4 kg/sqm) with cast iron frame,funnel with wire mesh,20mm bore GI pipe medium grade watering pipe,lugs,40mm bore GI pipe medium grade protection pipe upto 7.5 m as directed.
S&F in repair MCCB, 160 Amps, four pole, 25 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge.
S&F in repair MCCB, 100 Amps, four pole,16 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge.
S&F in repair MCCB, 63 Amps, 4 pole,16 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge.
Supply, install, testing and commissioning in repairs on load change over switch 100 Amps, four pole, 415V AC, 50HZ enclosed in sheet metal enclosure complete all as specified and directed by Engr-in-charge
Supply, install, testing and commissioning in repairs on load change over switch 125 Amps , four pole, 415V AC, 50HZ enclosed in sheet metal enclosure complete all as specified and directed by Engr-in-charge
Taking down fire detectors for false ceiling and refixing them with complete connection all complete all as specified & directed by the Engineer-in-Charge.
M&L for 1.5 sqmm 2 core FRLS multistranded copper conductor cable drawn through and including stove enamelled steel conduit 20 mm dia fixed on wall/ceiling with all accessories including fixing accessories complete all as specified & directed.
Demolition of cement concrete in ground floors and pavings not exc 15 cm thickness ( below or above ground level ) and disposing of debries outside MD land complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling of Stone slabs & tiles of any description or thickness in floors, aprons etc. Laid, bedded & pointed in any mortar complete all as specified and directed by Engr-in- Charge
Taking down chowkats or frames with shutter (without taking off shutters from the frame) not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down chowkats or frames with shutter (without taking off shutters from the frame) exceeding 1.5 Sqm not exc.4 sqm each complete all as specified and as directed.
Dismantling of Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including hangers & cover fillets/frame work complete all as specified and directed
Disconnecting existing tanks, exc. 250 ltr and n. exc. 500 ltr capacity setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
Disconnecting existing tanks, exc. 500 ltr and n. exc. 1000 ltr capacity setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
Taking down old existing roof treatment (APP membrane and plaster) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc including removing debris outside MD land complete all as specified and directed by Engr-in-Charge
Demolition of cement concrete in any position of any description and disposing of debries outside MD land complete all as specified and as directed.
Dismantling of Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
M&L for Precast cement concrete 1:3:6 type C1 (Using 20 mm graded stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified including demolition and as directed by the Engr-in - Charge.
S&F in repair for 15 mm bore CP wall mixer (3-in-1 ) for mixing hot and cold water with arrangement for both telephonic hand shower and overhead shower with long bend pipe complete all as specified and directed (Make Cera cat part No. F1005413 (Ruby))/Johnson Cat part No. T3223C (Fusion)/Jaquar Cat part No. FUS-29281(Fusion) or equivalent
S&F in repair for One piece EWC with seat cover and Twin flush fittings of size 640 mm x 350 mm x 725 mm of snow white colour incl 220 mm S trap complete all as specified and directed ( Make Cera Catpart No. S1013208VS(Cattler)/Jaquar Cat part No. FSS-WHT-29853S300UFSM(Fusion)/Johnson Cat part No. G3907P0103 (VIGO) or equivalent
S&F in repair for counter top wash hand basin of size 520 mm x 450 mm x 200 mm of snow white colour incl all necessay fittings etc complete all as specified and directed (Make Cera Cat part no. S2030101 (Clair) / Johnson Cat part No. P6212PW0401 (Grande) /Jaquar cat part No. ARS-WHT-39601(ARIA) or equivalent)
S&F in repair for Single lever basin mixer with 450 mm braided connection pipe complete all as specified and directed (Make Cera Cat part No. F1005451(Ruby)/Jaquar cat part No. FUS-29052B (Fusion)/Johnson cat part No. T3245C (Fusion) or equivalent
S&F in repair for 15 mm bore angle valve fancy type, CP, cast copper alloy screwed down high presure, with wall flange complete all as specified and directed (Make Cera cat part No. F1005201 (Ruby)/Johnson cat part No. T3212C (Fusion)/Jaquar cat part No. FUS-29053 (Fusion) or equivalent)
S&F in repair for 15 mm bore Bib cock fancy type, CP, cast copper alloy long nose with wall flange complete all as specified and directed (Make Cera cat part No. F1005152 (Ruby)/Jaquar cat part No. FUS-29037 (Fusion)/Johnson cat part No. T3205C (Fusion) or equivalent)
S&F in repair for 15 mm bore 2 way CP bib cock with wall flange complete all as specified and directed (Make Cera cat part No. F1005161 (Ruby)/Johnson cat part No. T3208C (Fusion)/Jaquar cat part No. FUS-29041 (Fusion) or equivalent)
S&F in repair for fancy type overhead shower of size 200 x 200 mm with necessary fittings complete all as specified and directed (Make Cera Cat part No. F7010503AB/Jaquar cat part No. OHS-35497/Johnson cat part No. S0006C or equivalent
S&F in repair for health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long SS braided connection pipe and ABS wall hook including making connection and fixed in position complete in all respect as specified and directed (Make Cera cat part No. F8030111AB/Jaquar cat part No. ALD 563/Johnson cat part No. S00305C or equivalent)
S&F in repair for towel rack of SS grade 304 with shelf 600 mm including necessary fittings complete all as specified and directed. (Make Cera cat part No. F5014131CH / Johnson cat part No. T1356C/Jaquar cat part No. CAN-1181FHS or equivalent)
S&F in repair for toilet paper holder with flap guard of SS grade 304 fitting with necessary screws complete all as specified and directed (Make Cera Cat part No. F5014110CH/Johnson cat part No. T1354C (Delta)/Jaquar cat part No. CAN-1153S or equivalent)
S&F in repair for CP towel ring of round shape with round flange complete all as specified and directed (make Cera/Johnson/Jaquar or equivalent)
S&F in repair for wall mounted Sink Mixer with flange with 150 mm long swivel spout and all other fittings complete all as specified and directed (Make Cera Cat part No.F1005501 (Ruby) or equivalent)
S & F in repair for PVC connection 15 mm size with nuts of length 450 mm, complete all as specified and as directed.(Make Cera cat part No. F8070402 or equivalent)
M & L for 15 mm GI tubing medium grade with all fittings fixed to walls, ceiling or laid in floors including taking up or down existing unserviceable steel tubing and connections complete all as specified and as directed.
M & L for 20 mm GI tubing medium grade with all fittings fixed to walls, ceiling or laid in floors including taking up or down existing unserviceable steel tubing and connections complete all as specified and as directed.
S&F in repair for sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed
S & F in repairs kitchen plate rack with four shelves made out of stainless steel sheet 1mm thick over all size 90x60x25cm complete all as specified and directed
S & F in repair for 20 mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and including taking down old gate valve all as specified and as directed.
Supply and fix in repair Vitreous china urinal half stall type white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60cm long brass screws, pointing around urinal back in cement, with grating and union for discharge pipe and PVC waste pipe, including making all connections to existing connections, fixed complete all as specified and as directed
S&F in repair for CP urinal spreader fancy type of approved quality fixing with 8 mm dia CP connection up to angle valve complete all as specified and directed.
S&F in repairs 32mm dia, 800mm long flexible PVC waste pipe complete all as specified and as directed.
S&F in repair for CP grating of size 100 mm dia with/without waste hole complete all as specified
S&F in repair for 15mm dia CP jet with CP flexible pipe 90cm long incl necessary fittings complete all as specified and directed (Make Cera/Jhonson/Hindware or equivalent) .
S&F for rotational moulded polyethylene water storage tanks of 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20mm dia HD polythene float (ball) and epoxy coated aluminium rod (fly nut) screwed for iron pipe or brass ferrule including taking down old one all as specified and as directed.complete all as specifed and directed.
All as per item no. 99 above but 1000 Ltrs capacity.
S & F 75 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches including taking down old pipes all as specified and as directed.
All as per item No. 101 above but 110 mm dia .
S & F for 110 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including taking down old pipes all as specified and as directed.
S & F PVC (SWR) bends any radius 75 mm dia, , in repairs all as specified and as directed
S & F PVC (SWR) bends any radius 110 mm dia of bore, including taking down old bends all as specified and as directed.
M&L for 15 mm thick rendering in cement mortar 1:4 or fair faces of brick or cement concrete surfaces finished even and smooth without using extra cement complete all as specifed and as directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed
M&L for preparation of old decorated unplastered surfaces of wall, including brooming or steel wire brushing, scrapping down smoke spot, moss, efflorescent salts, trading oil, greasy spots and stopping nails marks by applying 2-3 mm thick wall care putty and applying two coat of oil bound distemper to wall incl cleaning of windows, door internal fitting & any other surfaces by removing splashes/ spot after finishing the job complete all as specified and directed
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors complete all as specified and as directed by the Engr-in - Charge.
M&L for Vitrified light shade coloured tiles 9-10 mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 1.00 sqm in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in cement mortor 1:6 complete all as specifed and directed.
S&F coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in CM(1:6) complete all as specified and directed
M&L for Vitrified light shade coloured tiles 9-10 mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 1.00 sqm in skirting etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick plastering in CM 1:4 as in backing coat of tiles complete all as specifed and directed.
M&L for glazed ceramic coloured wall tiles of size 450mm x 300 mm x 7-8 mm/1200 mm x 600 mm x 9-10 mm thick size as directed including 10 mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces,set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specifed and directed.
M & L for renewing tiles in patches area n.exc 5.00 Sqm including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new ceramic tiles to match the existing floor/wall complete all as specified and as directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps,treads/risers jambs, pillars, win?dow-cills, cooking platforms/partition including chamfered in exposed edges and like in cement mortar (1:4) including pointing in white cement (1:2) us?ing marble dust with admixture of pigment to match with shade of granite incl necessary screed bed etc complete all as specified and directed
S&F Aluminium Anodized aluminium frame/shutter for doors, windows, ventilators, partition wall with one or more rebates including handle, tower bolt, hinges etc complete all as specified and as directed.
Add for Powder Coating to Aluminium Anodized aluminium frame/shutter for doors, windows, ventilators, partition wall (minimum thickness of powder coating 50 micron) complete all as specified and directed
S&F in repair for 18/19 mm thick PVC moulded solid board, of approved colour decorative for cabinet boxes,shutters etc. with shelf and shutters full size fitted including coloured topping on all exposed edges under /above kitchen cooking platform and other platform including necessary ball catch fitting complete all as directed
S&F for 12 mm solid PVC ply of 1st quality of approved colour fixed with necessary joining cleats, glazing clips, rubber packing, aluminium snap beading, screw etc complete all as specified and as directed by Engr-in-Charge.
S & F for 4.8 mm thick sheet glass ordinary quality in square exc 0.50 Sqm each in each pane including rubber beading for fixing of glass complete all as specified and as directed by Engr-in-Charge .
S&F for Hasp and staple, safety type, stainless steel including bolt to hinge plate and fixed with screws all as specified and directed.
S & F for Continuous (piano) hinges width of flap 30 mm mild steel, bright finish or electrogalvanised complete all as specified and directed
S & F for stainless steel handles 75 mm long complete all as specified and as directed by Engr-in-Charge .
S&F for Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) complete all as specified and directed
S&F for Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with particle board core with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face complete all as specified and directed
S&F for butt hinges medium weight stainless steel of size 75 mm complete all as specified and directed.
S&F in for hinges medium weight stainless steel of size 100 mm complete all as specified and directed.
S&F for Aluminium anodised barrel tower bolt, of extuded section and fixed of 150 mm long complete all as specified and directed.
S&F for 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F for extruded aluminium alloy handles fabricated type, anodised 150 mm long all as specified and directed
S & F for stainless steel barrel tower bolts of 150 mm long complete all as specified and as directed by Engr-in-Charge .
S & F for stainless steel handles 150mm long complete all as specified and as directed by Engr-in-Charge .
S & F for stainless steel sliding door bolt with hasp, staple bolt type and fixing clips of sheet of 300 mm long complete all as specified and as directed by Engr-in-Charge.
S&F in repairs cast iron body Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width & of weight between 61 to 80kg.complete all as specified
S & F in repair 150 mm floor door stopper of aluminium alloy powder coated, with hard drawn steel spring all as specified and as directed.
S&F in repair for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of mild steel heavy duty including taking down old one all as specified and as directed.
S&F in repair for Venetian blinds, vertical/horizontal type, 100 mm wide with polyester fabric of approved colour and pattern with aluminum fittings, and top rail and nylon buttons / loops etc., fixed cuttings and alteration if necessary wherever AC / coolers exists including dismantling of old unserviceable venetian blinds, complete all as specified and as directed.
Supply and fix in repairs 20 mm dia with 1 mm wall thickness curtain rod in any length, high strength stainless steel pipe including required bracket/finials complete all as specified and as directed
S&F for Solar control film 50 micron reflective type, pattern as approved sticked to glass panes as per instructions of manufacturers complete all as specified and directed
S& F for Solid PVC Wall Lining consisting of 5mm thick single side prelaminated PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed
S&F for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed
S&F in repair for powder coated GI grid frame work for false ceiling fixed with screw suspended with 6mm dia GI (upto 1200 mm length) adjustign level fixed to roof slabs by means of ceiling cleates made out of GI flat 40 x 3 mm size 60mm long complete all as specified and as directed
S&F for 5-6 mm thick PVC ceiling board fixed in flat surfaces on snap grid frame work including complete all as specified and directed
S&F in repair for anodised aluminium snap grid frame work for false ceiling ceiling fixed with screw suspended with 6mm dia GI (upto 1200 mm length) adjustign level fixed to roof slabs by means of ceiling cleates made out of GI flat 40 x 3 mm size 60mm long complete all as specified and as directed by Engr-in-Charge
M&L for 12 mm thick perforated particle board/tiles for insulation and accoustic purpose 60x60 cm in size fixed with staples on snap grid incl preparation of surface and applying two coats of oil bound distemper on new or previously untreated surfaces of ceiling complete all as specified and directed
M&L for Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish including joint filling with white cement complete all as specified and directed
S&F for rolled mild steel work Fe 290 (Gde E-165 ) Rolled sections as in main and cross beams, hip and jack rafters; purlins, Post etc where connected to common rafters and running rails and guides for sliding doors; sheets, fixed with angle cleats or other connecting plates complete all as specified and directed by Engr-in-Charge
M&L for PCC 1:2:4 type B 0 (using 12.5 mm graded aggregate) as in pedding layer on roof complete all as specified and directed
M&L for 10 mm thick rendering in cement mortar 1:3 with water proofing compound @3% by weight of cement, on concrete surface on roof, finishing even and smooth without using extra cement complete all as specified and directed by the Engr-in-Charge. Note-WPC shall be paid separately
M&L for preparing new surface of roof and applying two coats of Polyurethane (PU) acrylic based water proofing liquid compound over and including a coat of diluted elastomeric self primer and reinforcement fabric sheet as per manufacturer's instruction to stop leakage/seepage from roof/wall complete all as specified and directed by Engr-in-Charge. Note- Quoted rate shall be deemed to be included for work in buildings/structure of any height
Supply only integral water proofing compound
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, disposal of unserviceable materials, debris and rubbish outside MD land complete all as specified and as directed by the Engr-in - Charge.
M&L for reinforced cement concrete type B-1 1:2:4 (using 20 mm graded aggregate) (nominal mix) as in fins, fascias, louvres, Chajjas, shelves and similar articles complete all as specified and as directed. (Note- The rate quated by the contractor inclusive of necessary formwork as directed by Engr-in-Charge)
M&L for Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed.
M&L for 75 mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregates as in sub base complete all as specified and as directed.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed
M&L for 35 to 40 mm thick precast RCC Jallies of pattern as approved including frame , balusters, bressumers, kneelers, string courses fixing in any position with CM 1:4 including demolition of old jallies and thrown outside MD land complete all as specified and directed
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for Factory made Vitrified heavy Duty parking tiles coloured, matt finish,unglazed and unpolished of size 300x300x10mm thick including 15 mm thick screed bed in CM (1:4) complete all as specified and as directed by Engr-in-Charge.
S&F for at or near ground level factory made cement concrete kerb stone in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise discribed, and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
M&L for preparation of new concrete surfaces of any description over 10cm in width or girth not otherwise discribed, and applying two coats of synthetic enamel paint (ordinary tint) complete all as specified and as directed.
S&F in repair for 5 mm thick approved coloured ACP (Aluminium Composit Panel) sheet cladding over MS frame work or any other surfaces including making necessary arrangement for light, vertical , horizontal offset of any size/any pattern complete all as specified and directed.
S&F in repair for Ready made vanity cabinet for toilets of Basin size-120 cm x 46 cm, Base Cabinet size-119 cm x 45.2 cm x 49.7 cm, Side cabinet size- 37.9 cm x 23.7 cm, 180 cm, Mirror size- 110 cm x 80 cm (Make - Hindware Cat part No. 70084 (EBELLO) or equivalent) including all arrangement complete all as specified and directed.
Supply and Fixing in repair position Phenol bonded Bamboowood flooring with planks of size 14 mm thick, 1800 mm length (minimum) and 130 mm wide (minimum), in approved colour, texture and finish having Performance Appraisal Certificate (PAC) issued by Building Material & Technologies Promotion Council (BMPTC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4 mm thick expanded polythelene foam sheet having density 40 kg/cum, over prepared surface with necessary quarter round planks of size 1900 mm x 44 mm, wherever required, The bamboowood planks shall have minimum density of 1000 kg/cum & minimum Hardness 1000 Kgf with Eco friendly/UV coating, all complete all as per direction of the Engineer-in- Charge
Supply and fixing in repair position Phenol bonded Bamboowood in wall/skirting with planks of size 14 mm thick, 1800 mm length (minimum) and 85 mm wide (minimum), in approved colour, texture and finish having Performance Appraisal Certificate (PAC) issued by Building Material & Technologies Promotion Council (BMPTC). The skirting shall be fixed with SS screws & rawl plugs over underlayment of 4 mm thick expanded polythelene foam sheet having density 40 kg/cum, over prepared surface with necessary quarter round planks of size 1900 mm x 44 mm, wherever required, The bamboowood planks shall have minimum density of 1000 kg/cum & minimum Hardness 1000 Kgf with Eco friendly/UV coating, all complete all as per direction of the Engineer-in- Charge
J S Construction Company
M/S KAUTILYA GARG
Harsh Enterprises
M/s Vishnu Infrastructures
VIKAS CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .