Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹16.5 Laccepted-aoc | accepted-aoc |
Tender Value
₹16.5 L
EMD Value
₹42,750
Closing Date
22 Dec 2025, 10:59 pmClosed
Department of Medical Education
HARISHA N
Providing Comprehensive Annual Maintenance contract services for Firefighting systems installed at various Blocks of KMIO for a period of TWO Years and supplying and re- filling of Fire Extinguishers
DME/2025-26/SE0553/CALL-2
DME/2025-26/SE0553/CALL-2
Open
Two Tender Document System(Two Cover)
Kidwai Memorial Institute of Oncology Bengaluru
3 documents required · 2 mandatory · 1 optional
The bidders has to upload all the documents as per the elegibility criteria
₹500
₹42,750
22 Dec 2025
8 Dec 2025
23 Dec 2025
19 Dec 2025
C02 4.5Kg Squeeze grip 15.34 Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinguisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Secs, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138
Providing ABC Powder based MAP 50, 4Kg Supply and installation of 2kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal),
Providing ABC Powder based MAP 50, 2Kg 15.2 Supply and installation of 2kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal),
Re- filling of existing Fire Extinguishers for clean Agent HCFC 123, 2kG, The re-filling rate shall include cost of all lead and Lifts, transportation, loading / un loading, fixing and all other incidental charges etc. complete as per specification and directions of the Engineer in- charge of the work PWD SR Rates 23-24 , Fire Fighting page 43 , item 15.185
Re- Filling of existing C02 Squeeze Grip fire extinguishers 4.5 KG. The refilling rate shall include cost of all lead and Lift charges transportation charges, loading and un loading. fixing and all other incidental charges etc. complete as per specification and directions of the Engineer-in- charge of the work PWD SR Ele 23-24, Firefighting page 44, item 15.193
Re- Filling of existing C02 Squeeze Grip fire extinguishers 2 KG. The refilling rate shall include cost of all lead and Lift charges, transportation charges, loading and un loading. fixing and all other incidental charges etc. complete as per specification and directions of the engineer-in- charge of the work PWD SR Ele 23-24, Firefighting page 44 , item 15.191
Re- Filling of Existing Fire Extinguishers for ABC powder coated MAP50 2 Kg. the refilling rate shall include cost of all lead and Lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete as per specifications and directions of the Engineer in- charge of the work PWD Ele SR 23-24 Fire Fighting page 41 item 15.165
Re- Filling of Existing Fire Extinguishers for ABC powder coated MAP50 4 Kg. the refilling rate shall include cost of all lead and Lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete as per specifications and directions of the Engineer in- charge of the work PWD Ele SR 23-24 Fire Fighting page 41 item 15.166
Re- Filling of Existing Fire Extinguishers for ABC powder coated MAP50 6 Kg. the refilling rate shall include cost of all lead and Lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete as per specifications and directions of the Engineer in- charge of the work PWD Ele SR 23-24 Fire Fighting page 41 item 15.167
Providing CMC services for Fire Alarm systems at PACS Room. The contractor Agency shall quote the rates after the site visit
Providing CMC services for Fire Alarm systems at server Room. The contractor Agency shall quote the rates after the site visit
Providing CMC services for Fire Alarm systems at Major OT . The contractor Agency shall quote the rates after the site visit
Providing CMC services for Fire Alarm systems at SCI Block,
Providing CMC services for Fire Hydrant systems at Jindal block/ Major OT/BMTBlock. Installation details Scope of Work Maintenance & repairs works of firefighting systems Viz Fire Alarm system, PA system, talk back, system, hydrant & riser system, sprinkler system, with diesel engine pump, wet riser pump, sprinkler pump, Jockey pump, dewatering pumps, two submersible pumps
Providing CMC services for Fire Hydrant systems at Infosys OPD Block. Installation details Scope of Work Maintenance & repairs works of firefighting systems. Maintenance of sprinkler system, with diesel engine pump, wet riser pump, sprinkler pump, Jockey pump, dewatering pumps, two submersible pumps. Fire Electrical Control Panels at Basement Hydrant pump - 20 HP, Sprinkler pump -15 HP, Jockey pump- 15 HP
Providing CMC services for Fire Hydrant systems at Anikethana Building. Maintenance & repairs works of firefighting systems Viz Fire Alarm system, PA system, talk back, system, hydrant & riser system, sprinkler system, with, Jockey pump. Fire Electrical Control Panels at Basement, Jockey pump- 10 HP
Providing CMC services for Fire Alarm systems at CT Scan Rooms. The contractor Agency shall quote the rates after the site visit
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tender 458 2025-26 CMC services for Fire Hydrant System.docx
Tender Document • 0.90 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .