Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹84,474.50Accepted-AOC 676301 | MALAPPURAM | KERALA | 676301 | 1 | Accepted-AOC Accepted | |
| 2 | 2₹85,063+₹588.50 (0.70%)Rejected-Finance | 2 | Rejected-Finance High |
Tender Value
₹84,717
EMD Value
₹2,118
Closing Date
2 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
BDO
Block Development Officer Tanur
MLA SDF 2023-24, RENOVATION OF EXISTING BUILDING OF GHSS CHERIYAMUNDAM FOR THE PURPOSE OF GOVT NURSING COLLEGE (ELECTRIFICATION) (WC6736)
2024_CRD_676613_5
B-982/2023
Open Tender
Electrical Works
Item Wise
90 days
Block Development Office Tanur
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
Yes
₹2,118
Yes
3 Sept 2024
21 Jun 2024
3 Jul 2024
21 Jun 2024
2 Jul 2024
21 Jun 2024
Amount
Electrification
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
Supplying and fixing following size modules. GI box along with modular base & over plate for moular switches in recess etc as required 8 module (75mmX75mm)
Supplying and fixing following size modules. GI box along with modular base & over plate for moular switches in recess etc as required 8 module (125mmX125mm)
Supplying and fixing following modular seitch/socket o the existing modular plate & switch box including connections but excluding modular plate ect. As required 5/6 amps switch
Supplying and fixing following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS Complaing) 32A DP switch with indicator
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supply and fixing of following size of medium class PVC conuit along with accessories in surface recess including cutting the wall and making good the same in case of recessed conduit as requied 20 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
Supplying and fixing following rating, double pole 240 Volts, isolator in the existing MCB DB completed with connectiosns testing and commissioning etc. as required 40 amps
Supplying and fixing following rating, double pole. (Single Phase and neutral) 240 volts, residual current ciruuit breaker (RCCB), having a sensitivity current upto 300 milliameres in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps
Supplying and fixing 5 amps to 32 amps rating 240/415 Volts C curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection tesing and commiossioning etc. as required single pole
Supplying and following way single pole and neutral, sheet steel MCB distribution board 240 V on surface recess completed with tinned copper bus bar neutral bus bar, earth bar, din bar, interconnection powder painted including earthing etc. as required (But whithout MCBIRCCB) Isolator 2 way double door
Supplying and fixing single pole blanking plate in the existing MCB DB completed etc. as required
FAHADU M
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1052485.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .