Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.5 L+₹11,445 (0.38%)Rejected-AOC D S ELECTRICALS D S MANDIRAM SREEVARAHAM VALLAKADAVU P O TRIVANDRUM | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | L2 | Rejected-AOC L2 | |
| 3 | L3₹31.1 L+₹66,652.30 (2.19%)Rejected-Finance BETHAL THIRUMALA TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695001 | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | D SURESH L2 | Best Power Controls L1 | STEPHEN MOSES L3 |
|---|---|---|---|---|---|---|
| 1.00SITC of UPS | ||||||
| 1.00 | OD97008/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 5 KVA, Single phase in and single phase out UPS with zero transfer time, DSP based control , IGBT rectifier and IGBT inverter, provision for enhancing UPS capacity by operating UPS in N+X parallel (Up to 4 systems), RS232 port, input PF> 0.99@ full load, unity output PF (5KVA=5KW), input voltage range 160V- 280V with auto cut off, THD </= 10%, overall efficiency (AC to AC) >/= 94% , Display panel (in-built LCD and LED) with all measurements and fault indication and LED indications, Audible alarms for: "replace battery, overload warning and shutdown, Low battery, High temperature warning and shutdown". Suitable for operation in 0-40 degree Celsius ambient Temperature with a noise level<50 dbA at 1m distance and noise level should reduce with load., Generator compatibility, pure sine wave , Battery overcharge and undercharge cut off , Cold start, Automatic restart, self diagnosis, Automatic Bypass arrangement. The UPS system shall include necessary parallel kit and all battery accessories including MS open racks complete with interconnections. The system shall comply with IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS and relevant IS standards. All relevant type test certificates shall be provided and the UPS system shall include a minimum warranty of 3 years for UPS and 4 years for battery. UPS Make : Delta, Legrand- Numeric, Hykon or equivalent make) , Battery Make : Exide EL / Amaron Quanta, c10 Battery suitable for a minimum VAH of 15840 | 10 | each | 2,49,000 ₹24,90,000 | 2,46,000 ₹24,60,000 Lowest | 2,61,337.5 ₹26,13,375 |
| 1.00 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door | 10 | each | 2,546 ₹25,460 Lowest | 2,724 ₹27,240 | 2,724.44 ₹27,244.4 |
| 1.00 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | 80 | each | 272 ₹21,760 | 270 ₹21,600 Lowest | 301.21 ₹24,096.8 |
| 1.00 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 10 | each | 477 ₹4,770 Lowest | 600 ₹6,000 | 511.7 ₹5,117 |
| 1.00 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps | 10 | each | 2,230 ₹22,300 Lowest | 2,670 ₹26,700 | 2,386.69 ₹23,866.9 |
| 1.01 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. | 20 | each | 1,286 ₹25,720 | 1,100 ₹22,000 Lowest | 1,375.91 ₹27,518.2 |
| 1.01 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 300 | metre | 104 ₹31,200 | 111 ₹33,300 | 100 ₹30,000 Lowest |
| 1.01 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm | 200 | metre | 198 ₹39,600 | 210 ₹42,000 | 150 ₹30,000 Lowest |
| 1.01 | 1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm | 25 | metre | 313 ₹7,825 | 350 ₹8,750 | 240 ₹6,000 Lowest |
Tender Value
₹32.2 L
EMD Value
₹50,000
Closing Date
17 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Office of Executive Engineer, PWD Electrical Division, Thiruvananthapuram 695033
DEPOSIT Village offices in Kattakada Thaluk UPS Installation Providing UPS in 10 nos Village offices jurisdiction under Kattakada Thaluk as part of the E Office implementation General Electrical Work
2025_PWD_775518_1
EDT_ET_16_2025_26
Open Tender
Electrical Works
Item Rate
120 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹50,000
Yes
1 Sept 2025
8 Jul 2025
21 Jul 2025
8 Jul 2025
17 Jul 2025
8 Jul 2025
Amount
SITC of UPS
OD97008/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 5 KVA, Single phase in and single phase out UPS with zero transfer time, DSP based control , IGBT rectifier and IGBT inverter, provision for enhancing UPS capacity by operating UPS in N+X parallel (Up to 4 systems), RS232 port, input PF> 0.99@ full load, unity output PF (5KVA=5KW), input voltage range 160V- 280V with auto cut off, THD </= 10%, overall efficiency (AC to AC) >/= 94% , Display panel (in-built LCD and LED) with all measurements and fault indication and LED indications, Audible alarms for: "replace battery, overload warning and shutdown, Low battery, High temperature warning and shutdown". Suitable for operation in 0-40 degree Celsius ambient Temperature with a noise level<50 dbA at 1m distance and noise level should reduce with load., Generator compatibility, pure sine wave , Battery overcharge and undercharge cut off , Cold start, Automatic restart, self diagnosis, Automatic Bypass arrangement. The UPS system shall include necessary parallel kit and all battery accessories including MS open racks complete with interconnections. The system shall comply with IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS and relevant IS standards. All relevant type test certificates shall be provided and the UPS system shall include a minimum warranty of 3 years for UPS and 4 years for battery. UPS Make : Delta, Legrand- Numeric, Hykon or equivalent make) , Battery Make : Exide EL / Amaron Quanta, c10 Battery suitable for a minimum VAH of 15840
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
OD268154/2023-2024:Supplying and clamping 20 mm sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required
5.11:Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
D SURESH (BID ID -2253951)
STEPHEN MOSES (BID ID -2253921)
Bidder Name
D SURESH
STEPHEN MOSES
Best Power Controls
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1267534.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .