| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹19.6 L+₹2.1 L (12.1%)Rejected-Finance | L2 | Rejected-Finance Second Lowest | |
| 3 | L3₹19.8 L+₹2.3 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Third Lowest | |
| 4 | L4₹20.6 L+₹3.1 L (17.8%)Rejected-Finance 202 VIDYA NAGAR BEHIND SANJAY GANDHI MEMORIAL COLLEGE KAMRE RANCHI JHARKHAND 835222 | RANCHI | JHARKHAND | 835222 | L4 | Rejected-Finance Fourth Lowest | |
| 5 | L5₹21.6 L+₹4.1 L (23.2%)Rejected-Finance | L5 | Rejected-Finance Fifth Lowest |
Tender Value
Refer Docs
EMD Value
₹43,820
Closing Date
8 Jan 2022, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Major Sameer Wadekar
Holta Cantt, Palampur
PROVN OF CIVIL IPS CHANGING ROOM REST ROOM ALONG WITH BATHROOM AND TOILET FACILITY AND OTHER SANCTIONED WORKS AT ALHILAL MIL STN
2021_MES_494061_1
GEP/ - /2021-22
Open Tender
Civil Works
Item Rate
180 days
Alhilal Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹43,820
Yes
11 Mar 2022
11 Dec 2021
10 Jan 2022
11 Dec 2021
8 Jan 2022
25 Dec 2021
60 days
Amount
SCHEDULE 'A' PART-I: Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for 75mm thick Plain cement concrete 1:3:6 (Nominal Mix) type C-2 (using 40mm graded crushed stone aggregates), as in sub base flooring finished even and fair without using extra cement, complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block laid in floor, any shape and size conforming to IS-15658-2006 of 60mm thickness M-35 grade with grey cement & pigment, complete all as specified and directed.
M&L for sand filling in 25mm thick layer under floors or in foundation including watering and consolidation for laying interlocking tiles complete all as specified and directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick , set, jointed and pointed in neat cement slurry in floors with grey cement and pigments including screed bed or bedding layer of mortar 15mm thick in CM 1:6, complete all as specified and directed.
M&L for plain cement concrete, M-15 (Nominal Mix), type B-0, 1:2:4 (using 12.5mm graded aggregates) as in roof kerbs, mud stops, roof padding etc using water proofing compound, complete all as specified and directed. including Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. Note:- Water proofing compound shall be paid separately.
SCHEDULE 'A' PART-II: Surface excavation not exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified.
Excavation in trenches in type of soil not exc.1.5 m wide and not exc.1.5m deep and getting out complete all as specified.
PCC 1:4:8 type D2 (Nominal Mix) using 40mm graded crushed stone aggregates as in foundation filling and mass concrete complete all specified.
M&L brickwork with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M&L TMT bar 10mm dia and over cut to length,bent to shape required incl cranking bending and binding with and including mild steel wire(annealed) not less then 0.9mm dia complete all as specified and directed.
All as per the description of Serial item No. 11 above but 6 mm to 8 mm dia.
Returning filling in soil including spreading, leveling, watering & well ramming in layers not exceeding 25 cm thick complete all as specified.
Removel of excavation soil to a distence n. exc. 50m and depositing where directed at level n. exc. 1.5m above the starting point complete all as specified .
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed .
M&L for formwork to sides and soffit of floor or roof beams beam haunching, girders, lintels, cantilever, shelves including supports, overhangs etc complete all as specified and directed.
M&L reinforced cement concrete (design mix) M-25 using 20mm graded crushed stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M&L reinforced cement concrete (design mix) M-25 using 20mm graded crushed stone crushed stone aggregate in beams, cantilvers, bressummers, lintels over 1.50 m span complete all as specified and directed.
M&L reinforced cement concrete (design mix) M-25 using 20mm graded aggregate in columns, pillars, piers, posts and struts etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed.
S&F roof trusses (framed), trussed, purlins, crane girders, purlins, crane gantries, rails and fastenings and heavy brackets including distance pieces, cleats etc. complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated stee sheet 0.50mm thick of an olour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L painting steel surfaces of any description, over 10cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide all as specified and directed.
M&L for broken stone boulders hard core of gauge n. exc. 63 mm deposited, spread & lewvelled in layers n exc 15 cm th watered & rammed to a true surface complete all as specified and directed.
M&L 100mm thick Plain cement concrete (nominal mix) type C-2, 1:3:6 using 40mm graded aggregate as in floor base and the like all as specified.
M&L 25 mm thick, M-15, plain cement concrete, type B-0 (using 12.5 mm graded crushed stone aggregates) as in floors finished rough surface to receive floor finishes, complete all as specified and directed.
M&L for non-skid, ceramic, coloured tiles 7 to 8mm thick (Square/rectangular ) area of each tile exc 0.18sqm but n. exc 0.38sqm in floors, set and jointed in cement slurry and pointed in white or coloured cement to match with the shade of tiles including screed bed or bedding layer 15mm thick in CM 1:4 complete all as specified and directed.
M&L for Non skid ceramic coloured tiles7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, bedded and jointed in neat cement slurry , including pointed in white or colourred cement to match over and including 15mm thick screed bed in cement mortar 1:4, complete, all as specified.
M&L for glazed ceramic coloured tiles 300mm x 450mm x 7 to 8 mm thick as in vertical surfaces such as skirting, set and jointed in neat cement slurry, pointed in white or colourred cement to match over 10mm thick rendering in cement mortar 1:4, complete, complete all as specified and directed.
M&L for 50 mm thick, plain cement concrete, M-10 type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection, finished even and fair, complete, complete all as specified and directed.
M&L 15 mm thick plastering in cement mortar 1:4 on brick surfaces or surface other than fair faces of brick walls, as on external surfaces surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces , finished even and fair without using extra cement, complete all as specified and directed .
S&F pressed steel frames of size 125x60mm for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer and tarring back side of frame, complete all as specified and directed .
S&F steel ventilator with top hung shutter incl hinges, steel peg stay, complete with glazing bars dove tailed or welded, complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over coat of 3mm wall care putty and primer to walls complete, all as specified.
M&L for preparation of new plastered or unplastered wall surfaces and applying two coats of oil bound distemper white or tinted over a coat of primer, complete all as specified and directed.
S&F 2nd class hard wood (Sal / Hollock) factory made, plain framed, panelled shutters (two panels) with lock rail and panel of 12mm veneered particle board with commercial veneers on both faces. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, 35 mm thick fitted to chowkates, complete all as specified and directed.
S&F 2nd class hard wood (Sal / Hollock) factory made glazed and skelton shutters 35 mm thick, open rebated and prepared to receive glass or guage,etc. (without sash bars) edges of framing plain, chamferred or rounded, fitted with cut & mitred beads for securing guage sizes of members of shutters as specified in SSR Part-I Section 8.20 (a) for door shutter supplying and fitted to chowkhats, complete all as specified and directed.
S&F steel window side hung glazed shutters incl Box type hinges with steel handle and steel peg stay complete with glazing bars dove tailed or welded complete all as specified and directed .
S&F steel window side hung gauged shutters incl box type hinges with steel handle and steel peg stay complete without glazing bars dove tailed or welded complete all as specified and directed .
S&F solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
S&F factory made soild PVC profiled panel door shutter 28mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill,with 'C type Gl or 40 x 20 x19 of MS pipe as stiffner & supplying & fixing in frame at site as per specifications & drawing, complete all as specified and directed.
S&F aluminium, anodised, barrel tower bolts of extruded section and fixed of size 150 mm complete all as specified and directed.
S&F aluminium handles, cast type, anodised of size 150 mm complete all as specified and directed.
S&F mild steel cold rolled butt hinges medium weight 100 mm long, complete all as specified and directed.
S&F 300 mm long mild steel helical door , springs including roller and roller plate enamelled black fixed to wooden chowkat, complete all as specified and directed.
S&F mild steel sliding door bolt plate type stove enamelled black with 250 mm bright bolt not less 12mm dia with and incl a mini of 6 bolts and nut, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.457 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire stapples, complete all as specified and directed.
M&L for preparation of new wooden surfaces and applying two coats of synthetic enamel paint over one coat of pink primer exceeding 10cm widht or grith,complete all as specified and directed.
S&f 3mm thick sheet glass ordinary quality, sheet glass and glazing with oil putty or wooden beads in squares not exceeding 0. 50 Square metre in each pane, complete all as specified and directed.
S&f Hi steel clip inn false ceiling system plai/perforated with steel/ aluminium tiles ( 600x600)mm manufactured out of 0.50mm thick polister coil coated galvanised steel having 120/180 grams zinc coating or 0.70mm aluminium powder coated with 0.50 micron polyester paint in AA5050,AA3105 or AA1050 aluminium alloy. Tiles shall have square or bevelled edge, coil Coated steel tiles shall have 20 micron polyster coated finished or on the front side back side coat of 5 micron alkyd primer. two side of each tile are raised and piped and stopped to ensure postive engagement in to spring clip in profile allowing for demounting of indiviual tile.e rigid suspension system consist of row of 0.50 mm galvanised galvanised steel clip in profile of 38mm installed at 600mm centre to centre a spcing to support the tiles suspension angle are suspended from roof structure /truss by GI ceiling bracket these are jointed clip profile by hold on clamps. the tiles/ planks are held in place by pressuring clips. In the flexible system hanger and butter fly clip replaced the the suspension angle wall angle shall be of size 24mmx24mmx0.40mm thick made of coil coated steel or aluminium matching the colour of tiles incl necessary scafolding complete all as specified and directed.
S&F wash hand basin 550x400mm viterous china white, flat back, including brackets CP grating, PVC flexible waste pipe, PVC waste coupling complete all as specified and directed.
S&F looking mirror bevelled edge 600x450mm mounted over 4mm thick AC board or 6mm thick plywood commercial fixed with brass screws and cup washers complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank 1000 Ltrs capacity, ISI marked (cylindrical vertical with closed top), double wall layer construction, hoisted and fixed in position complete all as specified in SSR Part-I, making connections including 20mm bore ball valve brass float valve with ploythene float and fly nut complete all as specified and directed.
S&F 10 litre capacity PVC, low level, valveless, syphonic action type flushing cistern, inlet ball valve, float valve, handle and fixing arrangement, 32 mm dia PVC flushing pipe, complete all as specified and directed.
S&F vitreous china down water closet pan white orrisa pattern size 580x440 mm) (excluding flushing cistern and flush pipe) including connection into trap and flush pipe incl making good the disturbed portion of floor complete all as specified and directed.
S&F vitreous china urinals, Half stal comp incl providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing securing urinal to plugs with and including 60mm long brass screw including flushing cistern and flushing pipe complete all as specified and directed.
S&F steel water tubing 15mm bore medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
All as per the description of Serial item No 59 here-in-before but 20 mm bore.
All as per the description of Serial item No 59 here-in-before but 25 mm bore.
S&F stop valve cast copper alloy, screwed down, high pressure with crutch of butterfly handle, screwed both ends for iron pipe or for unions of 25mm bore and fixed,complete all as specified and directed.
S&F 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe 25mm bore and fixed, complete all as specified and directed.
S&F pillar taps 15mm cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot of Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F Chromium plated fancy bib taps, 15mm cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F Low density polythene pipe connection 450mm long suitable for connecting 15mm bore GI pipe including PTMT nuts on both ends complete all as specified and directed.
S&F Chromium plated shower rose with or without swivel joints any size including fixing to steel pipe or union complete all as specified and directed.
S&F 15mm bore stop valve/Angle Valve, cast copper alloy fancy type chromium plated screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union complete all as specified and directed.
S&F curtain rails harrison rails, mild steel, chromium plated with chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed.
S&F tubular towel rail, 20mm dia, 60 cm long, CP with a pair of brackets, fixed to wall with CP brass screw and PVC rowl plugs, complete all as specified and directed.
S&F Vitreous china, wash hand basin with pedastral (white) of size 550mmx400mm including brass CP waste coupling 32mm dia with long screwed shank and fly nuts, PVC medium grade 32mm dia waste pipe, chain and plug, porcelain stopper , PVC connection 15mm dia, 450mm long with brass CP nuts and washers at both ends complete all as specified .
S&F sink with drainage board made of stainless stell 1mm thick kitchen or laboratory with plugs, washers and waste coupling, incl bedding in CM to dwarf wall or providing cantilever brackets, PVC waste pipe and connecting union to pipe overall size 915mm x 460mm bowl size 410 x 330 x 160mm, complete all as specified and directed.
S&F 18/19 mm thick Block board grade 1 quality exterior grade Commercial type fixed with screws for shelves, kitchen/ cupboars etc, to timber frame work complete all as specified and directed.
S&F 1.5 mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions Make:- Sunmica/Formica/century liminates
S&F Ist class HW plain fillets, square / rectangular, wrought face of sectional area n.exc 3 Sqcm, securing with screw complete all as specified and directed.
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished, complete all as specified and directed
M&L for 100 mm thick PCC 1:2:4 type B-2 ( using 40mm graded crushed stone aggregate) as in sub base of floor and finishing the surface even & fair whtiout using extra cement complete all as specified and directed.
M&L out door heavy duty full body vitrified tiles of any shade ( As approved by GE) 600x600x15mm fixed with spacer over 6mm thick high polymer modified grey cement based tiles adhesive and grouted epoxy grout over and including 15mm screed bed in CM 1:4 laid in floor complete all as specified and directed .
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Excavation over area n exc 1.5m in depth and getting out in any type of soilcomplete all as specified and directed .
Excavation over area exc 1.5m but n exc 3m in depth and getting out in any type of soil complete all as specified and directed .
PCC, M-10, C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed .
M&L for PCC M-15 (Nominal mix) using 20mm graded crushed stone aggregate as in coping benching and the like including weathering, slightly rounded or chamfered angles and directed including form work and finishing complete all as specified and directed.
M&L for precast cement concrete type B-1, 1:2:4(20mm graded aggregate) set in CM 1:4 as in cover slab (for manholes etc) with similar articles with plain faces complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius, using old size brick, build in CM 1:4 complete all as specified and directed.
M&L for rendering 15mm thick on brick surfaces in CM 1:4 finished even and smooth without using extra cement including mixing of water proofing admixture in the proportion as mentioned in manufacture's instructions complete all as specified. Note:- Water proofing mixture shall be measured and paid for separately.
Supply only integral liquid water proofing compound complete all as specified and directed.
M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete M-10 (nominal mix) using 20mm graded crushed stone aggregate for 150mm bore pipes complete all as specified and directed.
M&L for reinforced conrete pipes, Class NP-2 drain pipes 150mm bore laid and jointed on concrete bed, complete including testing etc all as specified. Note:- concrete bed shall be measured and paid for separately
M&L for reinforced cement concrete, M-15 (nominal mix) type B1 (using 20mm graded stone aggregates) in slabs supported on walls, beams, and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
M&L for formwork to sides and soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exceeding 200mm thick, complete all as specified.
M&L for loose filling with brick aggregates of gauge 40 to 80 mm in soakage pits, soakage wells complete all as specified and directed.
M&L for brick work with sub class 'B' bricks in one brick thick honey combing walling built CM 1:4 complete all as specified and directed.
SCHEDULE 'A' PART-III: M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including new CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note:- (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed.
All as per the description of Serial item No 94 here-in-before but 5 Amp socket outlet on same board complete all as specified and directed.
All as per the description of Serial item No 94 here-in-before but socket outlet 5 Amps independent board complete all as specified and directed.
All as per the description of Serial item No 94 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 sqmm size complete all as specified and directed.
S&F switch piano, flush type single pole one way 5 Amp, 240 volts ISI marked complete all as specified and as directed.
S&F switch piano, flush type single pole, one way 15 Amps, 240 volts ISI marked complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 5 A complete all as specified and directed.
S&F socket outlet 3 pin, 15 Amp, flush type, 240 Volts, flush type complete ISI marked complete all as specified and directed.
S&F ceiling rose, 3 terminal surface type complete all as specified and directed.
M&L for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sq mm for phase and neutral and one run of 6.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note:- Wiring shall be done in proper colour coding.
S&F ceiling light with enviromental friendly, new generation, aesthetically designed, ultra modern recessed mounted LED light luminaries of size 595 mm x 595 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage- 6/40/42 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection suitable for Armstrong/ Grid ceiling with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. MAKE:- Havells Cat Part No: PLUTONEO2X2PLR42WLED857S or equivalent in CG/Philips as approved by GE
Supply & fixing surface/wall mounted light fitting pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat Part No for batten:- STREAKT8UPTO 1X22WSSBSWH of make Havells or equivalent in Crompton/Philips as approved by GE. Cat Part No for Tubelight:- PHOTANULTRAE2.0 1213T8SSTL18WLED865SPC of make Havells or equivalent in Crompton/Philips as approved by GE.
M&L for replacement distribution board steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
S&F of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F of SPN 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F fan hook suitable for 40mm dia pipe, made out of MS flat iron of size 50 x 6mm incl suitable size of nut, bolt & washer complete all as specified & directed
M&L for earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to 4mm dia galvanized iron wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 15mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, including testing on completion. NOTE: The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
Supply & hanging ceiling fan AC single phase 230/240 volts of size 1200 mm sweep, having service value > 4.0 including making connection with and including suitable flexible copper wire, complete all as specified and as directed. Make:- Usha Technix Plus / CG (H S Plus)/ Havells (ES-50 Premimum)
Supply & fixing exhaust fan AC single phase 230/240 V of size 300mm sweep, speed 1400 RPM power input 50-55 W, Heavy duty with louver having aliminium / sheet metal flap with thickness not less than 1.00 mm and mounting assembly including fixing exhaust fan with grouting of nut & bolts, complete all as specified and as directed. Make:- Crompton -EXHD300-6-1/Havells-Turbo force SP/Khaitan-HD Exhaust fan
S&F electric water storage Heater (vertical type Geysers) 50 Ltrs BEE 5 STAR, 230 volts AC single phase with and including grouting with high tensile rag bolt, nut & washer etc as directed as per site requirement and making necessary inlet / outlet water connection for Geysers.Geysers to have glass lines tank, fero glass coated container,PUF insulation, glass coated heating element, 8 BAR rated pressurer, thermostat cut off etc. complete all as specified and as directed. Make : Bajaj (Model No-Caldia) or Crompton (SWH Arno Neo ASHW-2125) Havells ( Puro project Model PURO PPT) Note:- Old unserviceable electric water heater to be deposited in MES store yard.
SCHEDULE 'A' PART-IV: S&F Air termination vertical type, Single pointed made with 12mm dia 300mm long aluminium rod including necessary fixing arrangements with aluminium bolts, nuts, lead wasters etc. complete and incl provisin of GI tubing light grade 40mm dia, 300mm long embedded in PCC block (size 30cm x 30cm x 30cm) one end and other end fitted with air termination rod all as specified and directed.
S&F Horizontal /down conductors, aluminium strip of size 25 x 3.15mm and incl epoxy insulator bus bar type 40mm thick at an interwal of 60 cm apart for lightening protection on roof and for down conductors, including all fixing arrangementsand aluminiun nut, bolt & washers complete all as per IS-2309-1989 and testing complete all as specified and as directed. Note:- Aluminium strip shall be jointed with rivets (minimum 4 Nos).
M&L for test point terminal block madeout and gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos 8 mm dia 25mm long hex head screw for fixing the same on wall complete all as specified and as directed.
S&F Galvanised from strip of size 32 x 6mm from earth pit to test point provided all around the bldg for lightening protection laid in trenches/fixed to walls on epoxy insulators with screws etc and connecting up complete all as specified and as directed.
M&L for earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to galvanized iron strip of size 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 40mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, including testing on completion. Note:- The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
SCHEDULE 'A' PART-V: Supply and Laying LT cable of size 10 sq.mm, 2 core 1100 Volt grade aluminium conductor laid in trenches / fixed to wall / pole / laid in floor including necessary connection and suitable size of thimbling complete all as specified and as directed. Note:- Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured and paid separately under appropriate item of this schedule.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
Removing excavated any type of soil to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning to underground cable provided a layer of sand 8cm before laying the cable and 15cm after laying the cable. The top layer of 15cm shall be punned to 10cm ( total 18cm) complete all as specified and directed.
M&L old size brick class 'B' as in cable protection laid dry, flat, transversally along the length of cable on sand cushioning with width equalto length of the brick complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal including necessary formwork and fair finishing to exposed surface without using extra cement complete all as specified and directed.
M&L cement concrete (1:3:6) type C2 using 40mm graded crushed stone aggregates for foundation of poles / struts / stays etc complete all as specified and directed.
S&F 40mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
S&F steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolt, nut and screws as specified 410 SP-31 (9 mter long) including taking down old damaged pole of any type and size, including one coat of red-oxide zinc chrome primer and two coats aluminium paint on surfaces, exposed to view and making 30cm wide strips (Total 5 Nos) with yellow and black paint alternately on external surface, above PCC benching including with writing of pole No with letters/figures of size not exc 30 mm with black paint on a yellow circle of dia 75 mm after painting complete all as specified and directed.
S&F LED street light fixture ≥ 90 Watt LED with pressure die cast aluminium housing with toughened glass having IP-66 degree of protection, individual LED's must have secondary lense for better throw across and along the road, with system luminarie efficacy ≥100 lumen/watt, colour rending index(CRI) of ≥ 70, co-related colour temperature (CCT) of 5700K. Luminaire should have surge protection upto 05 KV and having additional surge protection upto 10 KV for driver, PF ≥ 0.9 and THD ≤10% (Make of LED shall be Cree/Lumileds/Osram/Nichia), operating voltage range from 140 to 270 volt, The potted driver used shall be a constant curent driver with efficiency of ≥ 85%.The manufacturers LOGO shall be engraved into housing of luminaire complete all as specified and directed. Make: Cat Part No ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO of Havells or equivalent in Crompton/ Philips/Wipro
Supply, installation, testing and commissioning to electrical system distribution board (outdoor top canopy type), suitable size, factory made, single door, cubical type, back door fixed type, fabricated out of 3.15 mm thick CRCA steel sheet, powder coated, weather/dust/vermin proof, IP 65 protection, suitably spaced totally enclosed in chamber, with provision to enter light inside the panel for light sensing timer, earthing arrangement, inbuilt locking arrangement with two locks with duplicate key duly and including connection of all incoming and outgoing cables using suitable size lugs and glands, danger notice board, panel to be mounted on PCC block/brick piller complete all as specified and directed including comprising of following items :-
(a) MCCB 2 pole 63 amp, 415 volts 10 KA - 01 No. (b) Power contactor of capacity 70 Amp, 3 pole, 415 volts, 50 Hz-01 No. (c) Timer Switch (Analog sensor type) type suitable for 3 Phase distribution System. (d) Indication lamp (R,Y,B) LED type with suitable MCB control for each indicator - set of three Make of MCCB:- L&T/Legrand/C&S/ Schneider NOTE :-Before fabrication of panels the contractor shall submit detailed general arrangement drawing and single line diagram of LT panel for approval of Engr-in-Charge. A drawing shall also show foundation details, list of compents with manufacturer reference and bill of materials.
S&F moduler box made of FRP / impact resistance plastic & heat resistant materials suitable size of 50x250x150 mm single door to accomodate the fixtures with IP 65 for controlling of LED security light of any wattages, including provision of MCB SP 6 Amps, connector terminal block 4 pole suitable for fixing cable connection and fixing to pole with suitable size of clamps,nuts,bolts and painting steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to galvanized iron strip of size 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 40mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, including testing on completion. NOTE:- The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
BHARDWAJ BUILDERS
M/S THAKUR ENTERPRISES
M/s R S Construction
VIVEKA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .