Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.9 L+₹1.7 L (4.61%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L2 | Rejected-Finance Being other than L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
29 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/O 56 APO
Spl repairs to bldg No T-50 T-12 and T-41A including provn of certain minor work at Rajouri under AGE B/R Dett B of GE 862 EWS
2021_MES_486096_1
GER-55/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹92,000
Yes
7 Dec 2021
3 Nov 2021
1 Dec 2021
3 Nov 2021
29 Nov 2021
16 Nov 2021
60 days
Amount
Sch 'A' Part-I (B/R works) Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nanital or similar pattern roof coverings complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 Mpa as in ridges, hips, valley gutters, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Dismantling timber scantling 40 Sq cm and over in section, in any position (framed work) complete all as specified and directed.
S&F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
S&F for rolled mild steel joist, channel, angle, flat iron or Tee section, fixed independently, without connecting plates etc (cut to ordinary length ie within 20mm of the length indicated) conforming to Fe 290 grade E-165 complete all as specified and directed.
M&L for 4mm thick designer cement fibre ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing board etc complete all as specified and directed.
M&L for 15mm dia bib tap cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed for iron pipe complete as in repair all as specified and directed.
M&L for 15mm dia gun metal, gate/globe valve with iron wheel head screwed on both sides for iron pipes complete as in repair all as specified and directed. (Make:- L&T, Kirloskar ,Leader, Zoloto, Upadhya)
M&L for 20mm dia gun metal, gate/globe valve with iron wheel head screwed on both sides for iron pipes complete as in repair all as specified and directed. (Make:- L&T, Kirloskar ,Leader, Zoloto, Upadhya)
S&F for 32mm dia waste coupling of brass chromium plated for glazed ware sinks, basin etc with long screwed shanks and fly nuts, flange and bedded in red lead cement mortar complete as in repair all as specified and directed.
S&F for Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete as in repairs all as specified and directed.
S&F for 40mm dia PVC waste pipe of polythene, flexible, for wash hand basin or kitchen sink complete all as specified and directed.
S&F for 110mm dia PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed.
S&F for 75mm dia PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed.
M&L for 110mm dia PVC SWR bends complete all as specifed and directed.
M&L for 75mm dia PVC SWR bends complete all as specifed and directed.
M&L for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
M&L for providing RCC M-25 (Design Mix) using 20 mm graded stone aggregate) as in slab supported on walls, beams and coloumns in floors, roofs, landings etc and like complete all as specified and directed.
Taking up or down GI tubing 15 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
Taking up or down GI tubing 20mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
S&F for 15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specified and directed.
S&F for 20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specified and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 1000 ltrs including dismantling old unserviceable tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 20mm bore ball brass valve with union screwed for iron pipe and fixed complete after dismantling existing tank all as specifed and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 500 ltrs including dismantling old unserviceable tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 20mm bore ball brass valve with union screwed for iron pipe and fixed complete after dismantling existing tank all as specifed and directed.
M&L for block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work complete all as specified and directed.
M&L for Block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face complete all as specified and as directed.
S&F for 30mm wide flap when open, continuous (piano) hinges, mild steel, bright finish or elec trogalvanised complete all as specified and directed.
S& F for stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L for Steel windows factory made with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as per IS-1038 complete all as specified and directed.
M&L for Steel windows factory made with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded all as per IS-1038 complete all as specified and directed.
M&L for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Gde E-165 complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brick work using old size bricks sub class 'B', straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4), complete all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
M&L for stone walling of random rubble masonry (except stones, using old unserviceable stone after cleaning), uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete surfaces including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on stone walls, finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over one coat of chalk whitening complete all as specified and directed.
M&L for preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed.
Demolition of reinforced cement concrete in ground floor and paving n exc 15 cm thickness below or above the ground level complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 5mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, column etc for rought finished surface of concrete complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for vitrified tiles light shade (premium quality) 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 sqm in vertical surfaces, skirting/dado, pillers etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
S&F for factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
M&L for solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square complete all as specified and directed.
M&L for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M. S . frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing mentioned in SSR Part-II 2010 complete all as specified and directed.
M&L for Anodised aluminium frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
M&L for Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, mortice lock, 1 No, floor door stopper, anodised aluminium snap beading, screws etc including powder coating of any colour (thickness of powder coating not less than 50 micron) complete all as specified and directed.
M&L for Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21100mm long (2 no.) suitable handle (1no.) complete all as specified and directed.
M&L for steel ventilators (factory made) with top hung shutter including hinges, steel peg stay complete all as specified and directed.
M&L for 5.5mm thick sheet glass, ordinary quality fixed to aluminium doors in square exc 0.5 sq. m in each pane complete all as specified and directed.
M&L for 12mm thick prelaminated partical board, interior grade both side decorative choice lamination fixed to aluminium doors or as in cup board cabinets similar works complete all as specified and directed.
M&L for 15mm bore stop valve (angular), cast copper alloy screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete as in repair all as specified and directed.
S&F for PVC connection 15 mm x 450 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed.
S&F for viterous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern) and inlcuding flush pipe set of CP jet with PVC pipe of superior quality complete as in repair all as specified and directed.
S&F for PVC low level flushing cistern 10 ltrs capacity white with inlet ball valve, float valve and handle including providing & fixing MS angle iron brackets, PVC flush pipe complete as in repair all as specified and as directed.
S&f for vitreous China wash basin, white, flat back, size 550 x 440mm including 15mm bore CP pillar tap cast copper alloy, PVC connection 15mm length 450mm, low density PVC waste pipe(6 Kgf/sqm) of superior quality complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450x350x7mm/ 300x200x7mm (premium quality) on vertical surface such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10 mm thick backing layer of cement plaster in cement mortar (1:4) complete all as specified and as directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) exc 1.5 Sqm and n.exc 4 Sqm each and removing to store complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing to store complete all as specified and directed.
S&F for pressed steel door frame of size 125x60 mm with one or more rebates incl necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC (1:3:6) type C-0 using 12.5mm graded stone agregate complete all as specified and directed.
S&F for factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L for 4.0 mm thick sheet glass ordinary quality and glazing with oil putty and steel pins or wooden beads in squares not exceeding 0.50 square metre in each pane, complete all as specified and directed.
S&F for 150mm long aluminium anodized barrel tower bolts extruded section all as specified and directed.
S&F for 100mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F for 125 mm long extruded aluminium alloy handles fabricated type anodised complete all as specified and directed.
S&F for 300mm long aluminium alloy, anodised, sliding door bolt, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F for 140mm long floor door stopper of brass body and tongue with hard drawn steel spring complete as in repair all as specified and directed.
M&L for preparation of new wooden surfaces of any description exc 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of Synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for PCC type C-2 (1:3:6), (using 40 mm graded stone aggregates) in surface channels and drains complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level complete all as specified and directed.
M&L for 75mm thick PCC type C-1, (1:3:6) (using 20mm graded stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight) complete all as specified and directed.
M&L for pre-polished chequered cement concrete tiles of size 30 cmx 30cmx25 mm thick set, jointed in neat cement slurry in floor and pointed in white or coloured cement to match the shade of tiles laid over and including 20 mm thick screed bed in cement mortar (1:4) after demolition/dismantling of existing unserviceable cement concrete tiles complete all as specified and as directed.
M&L for complete removal of existing treatment form old decorated surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening complete all as specified and directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for foundation etc and n. exc 10sqm on plan and getting out in any type of soil complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed (Note: Punned thickness of sand shall be measured and paid).
M&L for PCC (1:4:8), type D-2 using 40mm graded stone aggregates as in foundation, filling and mass concrete complete all as specified and directed.
Dismantling of structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
S&F for kitchen sinks with drainage board made of stainless steel 1.00mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 60mm thick, M-35 grade (Medium Traffic), in paths and hardstanding,with grey cement, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE after demolition/dismantling of existing unserviceable precast concrete interlocking paver block complete all as specified and directed.
M&L for Machine cut kota stone slab(mirror polished) flooring 20-22mm thick in floors and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 20 mm thick in cement mortar (1:4) after dismantling/demolition of old unserviceable kota stone of any size complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of cement base paint over one coat of chalk whitening complete all as specified and directed.
M&L for LLDPE septic tank (conventional) of capacity 10 users designed to carry sewage and sludge water, excavation in any type of soil, PCC (1:4:8) type D-2 in foundation, vent shaft, connection etc including refilling of soil at sides of tank, well ramming in layers and removing excavated surplus soil to a distance not exc 50m complete all as specified and directed.
M&L for construction of soakage well 1.2 Mtr dia and 3 M deep including excavation and earth work in any type of soil, PCC (1:3:6) type C-2 in foundation, walls of honey combed masonry with top ring of M-25 concrete including intercerpting chamber and screen chamber made of Brick masonry in cement mortar 1:4, RCC cover slab in M-25, interconnecting pipes of RCC complete filled with brick bats complete all as specified and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2.
M&L for 150 mm internal dia Salt-Glazed stone ware drain pipes grade 'A' laid in trenches over concrete bedding jointed in cement mortar (1:1) and tested complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 100 mm dia PVC pipe complete all as specified and directed.
M&L for plain cement concrete type B-1 , 1:2:4 (using 20mm graded stone aggregate) as in coping, benching, hold fasts, water troughs, bed block and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
Supply only integral water proofing compound complete all as specifed and directed.
M&L for providing precast cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in manhole covers set in cement mortar 1:6 including necessary formwork and moulds complete all as specified and directed.
M&L for surface excavation in soft/loose soil n exc 30cm deep and averaging 15cm deep and getting out complete all as specified and directed.
M&L for providing reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for providing reinforced cement concrete M-25 (Design Mix), using 20mm graded stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed.
M&L for use & waste of formwork to sides of concrete foundation, footing, bases of colums, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub base complete all as specified and directed.
S&F for stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof suitable for 75mm bore pipe complete all as specified and directed.
M&L for 25mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection complete all as specified and directed.
M&L for 25mm dia gun metal, gate/globe valve with iron wheel head screwed on both sides for iron pipes complete as in repair all as specified and directed. (Make:- L&T, Kirloskar ,Leader, Zoloto, Upadhya)
Sch 'A' Part-II (E/M works) Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVC casing & caping of 25mm width (Medium grade double locking system) complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit)
Description all as per Serial item No 114 above but for one 5 pin 6 Amp socket outlet on independent board controlled by one 6 amp switch complete all as specified and directed.
Description all as per Serial item No 114 above but for one 5 pin 6 Amp socket outlet on same board controlled by one 6 amp switchcomplete all as specified and directed.
Description all as per Serial item No 114 above but for one 6 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for Switch piano, flush type single pole, one way 6 Amp, 240 volts complete all as specified and directed.
M&L for switch socket combination 2 in 1, 5 pin 5 amp flush type complete all as specified and directed.
M&L for Switch socket combination 5 pin 5 Amp/16 Amp, 230 volts, 5 in 1 flush type complete all as specified & directed.
M&L for socket 2 in 1, 5 pin, 5 amp, 240 volt, flush type complete all as specified and directed.
M&L for Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
M&L for Ceiling fan regulator elctronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed. (Make Bajaj /Crompton Greaves/Khaitan/Orient)
S&F for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete as in repair all as specified and directed. (Make :- Havells Cat part No HEXAFT10WLED857SSYMBOPC/Crompton Greaves Cat No. LBHP-10-CDL or equivalant of Philips)
M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete as in repair all as specified and directed. (Make :- Havells cat No LHEXAPP7IN1W020/Crompton Greaves Cat No LCTLN-20-CDL or equivalent in Philips
S&F for post top lantern light fitting 35/40 watts with cast aluminium spigot lid cover and clear acrylic cover with IP65 protection complete with all accessories including fixing arrangement on top surface of boundary wall or on pillar by providing GI pipe of suitable size and length as per site requirement and making good the distrubed portion to match with existing surface complete as in repair all as specified and directed. (Make:- Havells, Cat Part No. CORALPT35WLED757PSYMTOPC/Crompton greaves, Cat No LPTM-40-CDL/LPTC-40-CDL or equivalent in Philips)
M&L for MCB single pole, 240 volts any rating from 6 to 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cablescomplete all as specified and directed.
M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion including taking down existing unserviceable earthing complete all as specified.
S&F for XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 2 core laid in trenches/ on poles/ under road crossing etc. includig testing complete after taking down old unserviceable cable etc all as specified and directed.
S&F for XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sq mm 2 core laid in trenches/ on poles/ under road crossing etc. includig testing complete after taking down old unserviceable cable etc all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class LV, type 1 flat, size 250mm x 150mm x 40mm complete all as specified and directed.
M&L for galvanized steel tubing light grade with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as per site requirement of 50 mm bore GI pipe line complete all as specified and directed.
M&L for MCB single pole & neutral 240 volts any rating from 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cablescomplete all as specified and directed.
S&F in repairs High efficacy 2'x2' recess LED flat panel light fittings 36W LED 6000K edge-lit luminaire with in and including LED lamp suitable for armstrong/grid ceiling complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete as in repair all as specified and directed. (Make :-Havells, Cat part PLUTONEO02X2PLR34WLED840S / Crompton Greaves, Cat No LCTLSNE-36-FO-CDL or equivalent of philips.
S&F for LED bollard light fitting 8 watts cone shaped integral decorative with polycarvonate diffuser with IP 65 protection complete with all accessories and internally prewired and necessary fixing arrangement on PCC platform by providing GI bolts complete as in repair all as specified and directed. (Make:- Havells/Crompton Greaves/ Philips).
S&F for FRP looping box of size 250x200x100mm with connector and comprising of MCB SP 6 Amps, ISI marked, 240 volts complete with and including providing GI clamps, nuts bolts etc suitable for fixing on PCC pole/wall etc and including removing old unserviceable item complete all as specified and directed. (Make:- Sintex/National).
S&F for call bell AC, 230 volts single pole, ding-dong sound type complete all as specified and directed.
Supply, installation, testing and commssioning of wall mounted split type air conditioner 2.0 TR capacity of 3 star rating including cooling and heating mode for all weather condition with cordless remote control, single phase 240 volts complete with all accessories such as indoor and outdoor unit and refrigernet tubing of adequate length as required as site, indoor mounting plate, drain pipe of suitable size brought to ground level from any height includintg making cable connection by providiing three core 4 sqmm copper conductor cable PVC insulated, sheathed of adequate length as required at site and initial filling of refrigerant gas drain pipe and cables etc and making the round hole on existing wall of any type and making good the disturbed surface by matching with existing adjoining surfaces complete all specified and directed.
S&F for sheet metal enclosure single pole and neutral with two pin and earth plug and socket with one single pole MCB 20 amp complete all as specified and directed.
M&L for sub main wiring complete with 2 runs of 4 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable along with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade multi stranded copper conductor as earth continuity conductor drawn through and including PVC casing and capping of size 25mm width or above accessories fixed on wall/floor/ceiling etc all as specified and as directed. Note: 03 runs of cable and one run of casing capping shall be measured as one unit.
M&L for point wiring (Concealed) for one light point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVC conduit of 25mm dia with minimum thickness 2 mm (Medium grade) complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including necessary cutting, chasing etc and making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of conduit measured as one unit).
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
NATIONAL TRADING COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .