Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC RAMAKRISHNA COLONY PO MAJHIPARA DIST 24 PARGANAS NORTH PIN 743145 STATE WEST BENGAL | 24 PARAGANAS NORTH | WEST BENGAL | 743145 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹33.7 L+₹1.5 L (4.56%)Rejected-Finance 17 NO TIKIA MAHAL ORDERLY BAZAR PO PS BARRACKPORE DIST 24 PGS KOLKATA 700120 WB | KOLKATA | 24 PGS | WB | 700120 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹37.8 L+₹5.6 L (17.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹38.0 L+₹5.8 L (18.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹38.1 L+₹5.9 L (18.4%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹39.5 L
EMD Value
₹78,920
Closing Date
18 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BARRACKPORE
Office of the GE BARRACKPORE, KOLKATA - 700120
SPL REPAIR FOR BLDG NO T226 (BLOCK OF JCOs MD ACCN) OF 236 ENGRS REGT AT MIL STN KANCHRAPARA UNDER GE BARRACKPORE
2025_MES_699320_1
C/8979/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹500
GE BARRACKPORE
₹78,920
Yes
2 May 2025
25 Feb 2025
20 Mar 2025
25 Feb 2025
18 Mar 2025
11 Mar 2025
Amount
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of basin slabs/platform, urinal partitions and of any other description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Demolition of cement concrete in ground floor, (unreinforced) paving not execeeding 15cm thick(below or above GL) complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down all existing roof treatment and demolition of cement concrete padding/levelling course(any thickness as available at site)including wire brushing and cleaning loose dust etc from surfaces of RCC roof including flashing and junction of parapet complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and directed. (Note for Item No. 8.00 & 9.00 - Rate shall be deemed to be include for cutting holes/demolition of masionry walls etc for taking down chowkats and making good the damaged surfaces).
Dismantlin asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slab of any description including cover fillets complete all as specified and directed.
M&L for brick work with subclass 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks locally available best quality , straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
M&L for cutting chases, in brick wall, pinning in and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc and making good the disturbed surface, cutting not exceeding 10cm girth complete all as specified and directed.
S&F of factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing as mentioned in SSR Part-II (2020), Section 8, Page No. 178 complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification & drawing as mentioned in SSR Part-II (2020), Section 8, Page No.174 complete all as specified and directed.
S&F of 35 mm thick flush door shutters (factory made) solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed.
S&F of Pressed steel frames (Factory made) for doors size 105 mm x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including filing of concrete (1:3:6) type C-0 using 12.5mm aggregate after applying 02 shop coats of bituminous paint to back of chowkhats complete all as specified and directed.
S&F 25mm thick solid PVC composite sheet, prelaminated on front side and plain matching dark shade laminated background as in Cubboard flush shutters, fixed with and incl SS flush screws incl necessary cutting for reqd shape, rebate, hinges, hooks, etc and fixing only of self closing hinges, wall hanging hooks, magnetic locks, handles, etc complete all as specified and as directed. (Note :- (i) Necessary Hinges, hooks, handles and locks shall be measured and paid separately as' Supply Only' (ii) Labour charges for 'supply only' items are deemed to be included with quoted rates)
S&F 18/19mm thick solid PVC composite sheet, prelaminated on front side and plain matching dark shade laminated background as in kitchen cabinet shutters, backing, sides, top/bottom, etc, fixed with and incl SS flush screws incl necessary cutting for reqd shape, rebate, hinges, hooks, etc and fixing only of self closing hinges, wall hanging hooks, magnetic locks, handles, etc complete all as specified and as directed. (Notes:- (i) Necessary hinges, hooks, handles & locks shall be measured & paid separately as 'Supply Only' under relevant item. (ii) Labour charges for 'supply only' items are deemed to be included with quoted rates)
Supply only heavy duty Slim Nickel plated Stainless steel magnetic catch (L shape) with strong earth magnet, size 11mm x 35mm x 4mm complete all as specified and directed.
Supply only heavy duty stainless steel slip on hinges, self closing type with opening full overlay or 105°, suitable for 25mm thick shutter of maximum size 850mm x 550mm complete all as specified and directed.
Supply only ergonomically designed powder coated Aluminium anodised handle, finger pull type, suitable for 19mm thick shutter, size 14mm x 43mm complete including finish complete all as specified and directed. (Notes for item No. 22.00 to 24.00 :- Material for Item No. 22.00 to 24.00 to be incorporated in Item No. 20.00 & 21.00 here-in-before)
M&L of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F for 100mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed.
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section (as per IS-204 (Part 2) : 1992) and fixed complete all as specified and directed.
S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section (as per IS-204 (Part 2) : 1992) and fixed complete all as specified and directed.
S&F of 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F of 150 mm long aluminium anodised extruded alloy handle cast type (as per IS-208 : 1996) complete all as specified and directed.
S&F of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (overall length of cover plate 150mm) complete all as specified and directed.
S&F powder coated anodised aluminium alloy sections 3 tier track sliding windows series B weight of section frame 1.248Kg/m and shutter section weight 0.547 kg/m jindal or equivalent duly fitted with neoprene beading, glazing clips, tinted glass panes 5.0mm nominal thickness, aluminium wire cloth 0.45 mm dia and average width of aperture 1.4mm, aluminium alloy handles etc complete all as specified and directed. (Note : Rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc.)
S&F powder coated anodised aluminium ventilator with fixed aluminium frame of size 65x40x1.98mm thick or equivalent section fixed in vertical position with aluminium vertical members and half portion to be approved with 4mm thick pin head glass and remaining protion to be ouvered using 4mm thick pinhead glass and louvered porition covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm incl necessary channel frame work, including rubber gasket and aluminium beading, and make completed all as specified and directed. (Note : Rates shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading etc.)
S&F for MS rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including where required drilling, fittings, riveting or welding connecting with fish plate, gusset plates etc of Fe-410-W (Gde E-250) quality 'A' complete all as specified and directed.
S&F for MS rolled sections as in MS plates (Plain/chequered), channels, square cut or notched (ordinary and counter sink) forming holes, without any attachment etc of Fe-410-W (Gde E-250) quality 'A' complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of Red colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws / 'L' or 'J' type or cranked hooks bolts complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of Red colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of powder coated anodised aluminium snap grid frame work for false ceiling, size of grid 605 x 605mm using Main/Cross Bulbed tees - Tapered head (Web :25mm flange : 38mm) of weight not less than 0.249 Kg/m and equal angle of size 25mm of weight not less than 0.196 Kg/m complete all as specified and as directed.
S&F of hangers 6mm dia GI (not exceeding 1200mm in length apart) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm, 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed.
M&L for 4mm thick non asbestos fibre cement building boards (E-board) fixed or laid/inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.
M&L for 40 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor/paving etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 20mm graded crushed stone aggregate) as in subbsase/plinth protection including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 8 to 10 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
Ditto of Item No.43.00 here-in-before but in skirting over including a backing coat of 10mm thick rendering in cement mortar (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 450 mmX 350 mmX7 mm thick or equivalent set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering of cement mortar (1:4) complete all as specified and directed.
M&L for 18-20mm thick Mirror polished, high gloss finish Granite (absolute Jet Black) work in steps, jambs & soffits of chowkhat (incl necessary pasting), pillars, window-cills, basin platforms, urinal partitions and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl necessary cutting for sunk basin/sink, making holes for fixing hinges, door bolts, etc over and including 15mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
Providing edge moulding to 18-20mm thick granite stone slab including machine polishing to edge to give high gloss finish etc. Complete all as specified and directed.
M&L for mirror polishing on existing Kota stone/ stone work flooring/ skirting wherever required complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on fair face of brick works or concrete surfaces of walls with cement mortar (1:4) in two coats (10mm thick backing coat + 5mm thick plaster) mixed with WPC @200ml per 50 Kg of cement on 5mm thick plaster, finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for rendering 5mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L cleaning vertical and horizontal surfaces of of unplastered masonary wall and concrete surfaces for loose materials/dust and applying two coats of epoxy resin component (Dr. Fixit DAMPGUARD or equivalent) solution/mix using nylon brush pouring Base part in atttain homogeneous smooth paste and dilute the mixed compound with water in ration 1 part Base: 1 part Harder : 1 part water by slow addition and mix thoroughly until a brushable consistency is obtained, first coat will be allowed to dry for 6 to 8 hrs before application of second/fianl coat) including curing treated surface for 24 hrs complete incl applying evenly a coat of blown [email protected] kg/sqm over entire treated surfaces incl spout holes complete and all as specified as per manufacurer instruction.
M&L for preparation of RCC roof surface or wall & floor of sunken slab by cleaning the entire roof with Pressure water jet to remove the unwanted dust, loose material or any other material which may impair adhesion of the material. Surface must be cleaned and dried properly so that any cracks on the substrate can be visible. Concrete substrate to be cleaned up to exposed sound concrete cover, remove dust, laitance etc, which may impair adhesion of the material. All surface cracks up to 1-2 mm wide should be filled with single component cold applied elastomeric waterproofing coating (Dr. Fixit RoofSeal Ultra or equivalent) using a brush and adding a coat on the slab on both sides of the crack, up to a distance of 100 mm around it. Cracks more than 1-2 mm should be widen by making V-groove and repaired with PMM (Polymer Modified Mortar) using Dr. Fixit Pidicrete URP or equivalent 10% by weight of cement. Note : 1. Finished surface shall be as per satisfaction of Engr-in-Charge. 2. All cracks shall be prepared and checked by Engr-in-Charge before and after treatment for the satisfaction and rates quoted shall be including the quantum of cracks in proposed surfaces which shall be checked on grnd by the contractor before quoting bid. 3. No addl amount shall be claimed further for repairing cracks (unless deep structural cracks, if obtained after preparation of surfaces, which shall be adjusted through Deviation Order as per dirns of AO. 4. Entire application shall be carried out by trained certified manufacturer applicator only.
Material and labour for 25mm thick PCC 1:2:4, type B0 (using 12.5mm size stone aggregate) as levelling course, padding on chajjas, etc incl angular moulding at junction upto 10cm height complete all as specified with WPC @200ml/50 Kg of cement or as per manufacturer's instruction, applied over prepared surfaces complete all as specified and directed. Note : (i) WPC shall be measured and paid separately as 'supply only'. (ii) PCC shall be laid to acheive true slope towards the drain/weep holes.
Material and labour for single component cold applied elastomeric waterproofing coating (Dr. Fixit RoofSeal Ultra or equivalent) on in-accessible/accessible roof or wall & floor of sunken slab based on synthetic resin emulsion, tough yet extremely flexible coating that can be efficiently applied by roller or squeegee having fwg important features : (i) High film build up provides excellent water resistance. (ii) Excellent flexibility and elongation properties - can easily accommodate all normal building movements. (iii) Can be applied to complex shapes to form a seamless and highly durable water proofing coating. (iv) Adheres firmly to most of building surfaces incl both horizontal and vertical surfaces of parapet, etcs. (v) Suitable consistency for easy application by brush, roller or squeegee. Single component cold applied elastomeric waterproofing coating (Dr. Fixit RoofSeal Ultra or equivalent) shall be applied by sprinkling some water over the roof just before application of 1st coat @ 0.75 ltrs/Sqm uniformaly over the entire flat surface incl verticle parapets incl reinforcing fibre (45 gsm Glass fiber mesh) and allow for drying for 12 hrs and 2nd coat @ 0.75 ltrs/Sqm shall be apllied (perpendicular direction of 1st coat as per manufacturer's instruction) on dried 1st coat complete all as specified. Note : (i) Entire application shall be carried out by TRAINED CERTIFIED MANUFACTURER'S APPLICATOR only. (ii) Waterproofing treatment shall cover min 10 yrs WARRENTY by the applicator and Contractor. (iii) Quoted rates shall include WATER PONDING TEST : After full drying of second coat for at least 72 hrs, a water ponding test can be performed by filling water on the terrace by carefully blocking all the down take drain outlets without damaging the coating. The test shall be carried out for 48 hrs by filling water up to 50 mm level. Observe for leakages, if any, and then remove the water and allow the coating to dry completely for handingover of site. (iv) Application shall be restricted in open sunlight having temperature above 35°C.
Supply only Integral liquid waterproofing compound complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new or previously treated steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for complete removal of existing treatment & levelling of wall surface using MECHANICAL/ ELECTRICAL OPERATED SANDING/SCRAPING MACHINE WITH INBUILT VACCUM SUCTION system to such the existing treatment as retrieved by scrapping/sanding etc for obtaining smooth paintable surface complete all as specified and directed.
M&L for applying two coats of 100% Premium acrylic emulsion paint(using AIR-LESS PAINT SPRAYER) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall surfaces by using AIR-LESS PAINT PRIMER SPRAYER using smart technique including preparation/levelling of new surface of wall using manual sand papers(where reqd) of approved grade complete all as specified and as directed.
M&L for two coats of Oil bound distemper over prepared surface of wall over a coat of primer using AUTO-ROLLER and AIR-LESS PAINT SPRAYER complete all as specified and directed.
M&L for two coats of Oil bound distemper over prepared surface of ceiling over a coat of primer using AUTO-ROLLER and AIR-LESS PAINT SPRAYER complete all as specified and directed.
Taking up or down old unserviceable steel tubings including connections and cleaning for refixing or removing from site for 15 mm bore pipes complete all as specified and directed.
Taking up or down old unserviceable steel tubings including connections and cleaning for refixing or removing from site for 20 mm bore pipes complete all as specified and directed.
S&F of 20mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass CPVC fittings and cutting grooves, filled with Cement mortar(1:6) complete all as specified and as directed.
S&F of 25mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass CPVC fittings and cutting grooves, filled with Cement mortar(1:6) complete all as specified and as directed.
S&F of 50mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass CPVC fittings and cutting grooves, filled with Cement mortar(1:6) complete all as specified and as directed.
S&F in repairs of brass chromium plated Bib taps (suitable size for 20mm outer dia CPVC pipe) nozzle with flange for connecting delivery pipe washing machine complete all as specified and directed.
S&F in repairs of brass chromium plated Bib taps concealed type (suitable size for 20mm outer dia CPVC pipe) with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs of brass chromium plated angular stop cock with flange (suitable size for 20mm outer dia CPVC pipe) concealed type complete all as specified and directed.
S&F in repairs of brass chromium plated 2-way angular stop cock with flange (suitable size for 20mm outer dia CPVC pipe) concealed type complete complete all as specified and directed.
S&F in repairs of Brass CP 3 in 1 Wall Mixer for mixing hot & Cold water screwed down for iron pipe and fixed and joint with adhesive, taflon tape, etc complete including taking down old CP Bib tap complete all as specified and directed.
S&F in repairs of Brass CP Sink Mixer with movable neck, fixed to wall, for mixing hot & Cold water screwed down for iron pipe and fixed and joint with adhesive, taflon tape, etc complete including taking down old CP Pillar tap complete all as specified and directed.
S&F in repairs of Brass CP central hole basin mixer, fixed to wall, for mixing hot & Cold water screwed down for iron pipe and fixed and joint with adhesive, taflon tape, etc complete including taking down old CP Pillar tap complete all as specified and directed.
S&F of 40mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc. with long screwed shanks & fly nuts, flanged end bedded in red lead cement & other end fixed complete all as specified and directed
S&F of 32mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc. with long screwed shanks & fly nuts, flanged end bedded in red lead cement & other end fixed complete all as specified and directed
S&F in repairs of sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs of vitreous china wash basin, white, flat back, size 550 X 400 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F in repairs of mild steel chromium plated health faucet (ABS) with rubbit cleaning system, with 1.25mtr long easy flexible tube suitable for 20mm outer dia of CPVC pipe and wall hook including making connections & fixed in position complete all as specified and directed.
S&F in repairs of vitreous china wash down water closet pan (pedestal pattern) white with 'P' or 'S' trap type (excluding fixing bolt, flushing cistern & flush pipe) including connection to trap with 110mm PVC (SWR) connection and lip ring & to flushing pipe, anti-syphonage pipe out in with and including white seat cover etc. including making good to floor complete all as specified and directed.
S&F in repairs of 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia suitable for low level cistern fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F in repairs of 15 mm dia PVC connection pipe of length 600 mm with PTMT nuts complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor including taking down old unserviceable pipe complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F in repairs of 100 x 75 mm bore PVC (SWR) multi floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F of 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer) ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 20mm dia ball valve high pressure of PTMT (minimum weight 210 gms) including dismantling / taking down old unserviceable PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
S&F of stainless steel kitchen plate rack made out of SS-204/304 (0.85 mm - 1.00mm thick s/s sheet) of size 24" x 30" x 10" complete all as specified and directed.
S&F in repairs of 25mm dia (heavy duty) stainless steel, single curtain rod (wall thickness not less than 1mm) including funnels, brackets, stops etc suitable for single curtain rod, fixed etc complete all as specified and directed.
S&F 125mm long curtain rod side brackets of stainless steel (SS 202), angular or cantilever type fixed to wall with 02 nos screws on each bracket and fitted screws for fixing curtain rod incl stainless steel (SS 202) decorative design plain metal colour nobs (oval/shere shape) with fixing arrangement for curtain rod using a screw complete all as specified and directed.
PART-II : (E/M WORKS) Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as modular box, top cover plate, blank plate, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch .
One fan / exhaust fan point controlled by one switch and one regulator.
One light point controlled by two way switch .
One 3 pin 5 amps socket outlet point on same board .
One bell/buzzer point controlled by one push button.
One 3 pin 5 amps socket point on independent board .
Ditto- all as per Item No.92.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm for one 15A socket on independent board complete all as specified and directed.
S&F of angle/batten lamp holder, PVC polycab type with back plate suitable for batten fittings complete all as specified and directed.
S&F of call bell ding-dong sound type, 230V, 50Hz complete all as specified and directed.
S&F of modular bell push, 1 module, 5/6 Amps, 240 Volts complete all as specified and directed.
S&F of modular switch 10 Amps, single pole, 2 way, 1 module, 240V, AC, complete all as specified and directed.
S&F of modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, complete all as specified and directed.
S&F of modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, complete all as specified and directed.
S&F of modular socket 6Amp/16 Amps, 2/3 pin combined shutter socket, 2 module 240 V, AC, complete all as specified and directed.
S&F of modular fan regulator, electronic, 360 degree rotation (0 to 4), 100 to 120 Watts, 2 module, 240Volts, AC, complete all as specified and directed.
S&F of modular switch 16 Amps, single pole, 1 way, 1 module, 240V, AC, complete all as specified and directed.
S&F of ceiling rose , surface bekelite 65x50mm, three terminals complete all as specified and directed.
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make : Philips Cat No. TMC501T8 and MAS LED tube PC body/ Crompto Greeves Cat No. IGP 118 T8 and LT8-20865-2/ Surya Cat No. SUB 118 T8 & SLETLDS 20 PC or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure with metal type acrylic door, 415 volts, AC, VTPN DB (V-vertical type distribution board) 4way, for flush mounting with 200amps copper busbar, 2 neutral/earth bar for ease of installation and MCCB incomer of rating upto 63Amps, FP and MCB SP /SPN MCB's as outgoing and complete connecting cable links with top and bottom with IP43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable one complete all as specified and as directed. (Note : MCCB 3 pole 63 Amps as main incomer will be measured and paid separately)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat including taking down old unserviceable DBs complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way /L&T Cat No.DBSPN008GD/C&S Cat No. CSDBSPNPCGDD08 or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of MCCB, 100 Amps, 3 pole, 16/18KA breaking capacity Icu at 415 Volt with thermal magnetic release, 50 Hz housed with vertical load line DB and connecting under ground cable as main incomer to the bldg complete all as specified and directed.
S&F of RCBOs 40 Amps, 240 Volts, 50 Hz, 'C' series including necessary incoming and outgoing electric connection with suitable size of copper lugs complete all as specified and directed.
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, complete all as specified and directed
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 35sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking down existing cable of any type and any size complete all as specified and directed . (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed . (Note : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensured for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.)
M&L for earthing with glavanised steel earth plate electrode of size 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old earthing complete all as specified and directed. (Notre: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points as in soft/loose soil all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x .75mm laid dry flat complete all as specified and directed.
S&F in repairs of LED Bldg Security light Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed. (Make :- SURYA CAT NO-SLE UL 36WIP66LXN / HAVELLS CAT NO. ENDURASUNDOWN SL 35W LED 765PASYBOPC / PHILIPS CAT NO. BRPO46LED36CWMRSLPSUGRor equivalent model/Cat No of make as per Appx ‘A’ as mentioned in PS here-in-after)
M&L for GI pipe 50 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings including necessary MS clamp including taking down old unserviceable one complete all as specified and directed.
S&F of GI bracket pipe of size 32 mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on PCC & Steel poles/on wall surfaces and including suitable fabricate galvanised flat iron clamps of 30X6 mm thick -02 Nos suitable for fixing any place of poles with nuts, bolts & washers including grouting on wall etc including taking down old unserviceable one complete all as specified and directed.
S&F in repairs of sheet metal enclosures with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 Volts complete all as specified and as directed .
Taking down carefully ceiling fan of any size complete at site for rewinding and replacement of unserviceable parts i.e Capacitor, PVC connector, MS galvanised check nut, ball bearing, rubber pads, PVC strip clamps including servicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing with detergent powder to fan blades, painting fan, greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washer check nuts split pin rubber packing and rubber seal etc including testing after assembling and connecting to electric system complete all as specified and directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose to fan complete all as specified and directed.
Taking down existing electric meter carefully from the meter box and re-fixed the same in the new location all as specified and as directed by Engr-in-Charge.
Taking down carefully of exhaust fan louver of size 300/350 mm sweep made out of MS sheet heavy duty of 22 gauge for rewinding and replacement of unserviceable parts, including servicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing with detergent powder to fan blades, painting fan, greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washer check nuts split pin rubber packing and rubber seal etc complete includng provision of cables from ceiling rose or connector to fan and making holes for exhaust fan, making good the disturbed surface of wall both inner and outer side and match with the existing complete all as specified and directed. {NOTE- (i) Contractor will make all arrangement of safety devices and necessary T&P, and department will not be held responsible for any kind of accident and damage caused to man and machinary. (ii) Rate quoted are including necessary cutting chasing in brick/stone wall of 300mm suitable for fixing exhaust fan}
Taking down carefully storage type water heater of any capacity (Geyser) after disconnecting inlet/outlet/vent pipes, electric/earth connections etc cleaning of the body inlet/outlet/vent pipes, stop valve, non return valves etc leakage arresting of inner copper/steel tank by welding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washetrs etc refixing the same in position by replacing mounting bolts and nuts reconnecting all inlet/outlet/vent pipes electric/earth connections and carrying out testing for proper functioning complete all as specified and directed .
B N ENTERPRISE (BID ID -3265177)
SANDIPA TRADING CO. (BID ID -3265547)
M/s S K SHARMA (BID ID -3265339)
ABJ Pest Control (BID ID -3265649)
MAZUMDER AND CO (BID ID -3265715)
M/S. D. K. SINGHA (BID ID -3265530)
INDUSTRIAL CONSTRUCTION (BID ID -3263495)
RAJ TRANCON (BID ID -3265340)
DAS ENTERPRISE (BID ID -3265795)
BOSE BUILDERS AND ASSOCIATES (BID ID -3264562)
azad enterprise (BID ID -3265524)
M/S KARTICK CHANDRA CHAKRABORTY (BID ID -3264575)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .