Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹26.4 L+₹3.6 L (15.9%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | L3₹32.3 L+₹9.5 L (41.7%)Rejected-AOC | L3 | Rejected-AOC ok | |
| 4 | L4₹34.1 L+₹11.4 L (49.9%)Rejected-AOC 81 82 GHER SAIKH MITHOO KUBRHI PAKHAR ZAKHERA BAREILLY UP | BAREILLY | BAREILLY | UTTAR PRADESH | L4 | Rejected-AOC ok | |
| 5 | L5₹36.1 L+₹13.4 L (58.6%)Rejected-AOC | L5 | Rejected-AOC ok |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
2 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST
REPAIR / MAINT OF EXTERNAL ELECTRIC SYSTEM AT BAREILLY CANTT UNDER GE WEST BAREILLY.
2021_MES_446145_1
8945/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹50,000
Yes
30 Jul 2021
27 May 2021
7 Jul 2021
27 May 2021
2 Jul 2021
25 Jun 2021
27 May 2021 - 23 Jun 2021
60 days
Amount
Dismantling of LT PCC/steel tubular pole/stay assembly/street light of any size and discription incl coping, foundation etc and dismantling of serviceable insulators from poles for reuse and shifting to E/M yard or any other location.
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
M&L for stay assembly comprising of stay bow 40 cm long, 14mm dia complete with accessories as shown in electrical plate No -1 of SSR Pt- 1 with and including 20 mm dia stay rod , 215 cm long with threaded ends ,GI nuts, bolts , washers, thimbles including nuts, bolts and washers, 300mmx300mmx6mm stay plate, 7/8 SWG strand GI wire and also exposed surfaces shall be given two coats of aluminum paint over a coat red oxide primer complete including dismentling of existing damaged assembly. Note :- Stay clamps, Stay strand, PCC excavation and earth work shall be measured and paid for seperately.
Dismantling stay assembly complete from the pole all as specified and directed by Engineer -in-Charge.
Supply and fixing in replacement of stay wire stranded of size 7/3.15mm made of galvanised steel wire all as specified and directed.
Supplying,drawing and fixing in replacement of continuous GI earth wire/guard/cradles of 4mm dia including GI binding wire 1.63 mm and GI eye hook on LT poles incl taking down old rusted GI wire all as specified and directed.
Supply and fixing in replacement, loop type insulators, vitreous porcelain white, brown or green with over all size 65x90mm with clearance dia of the hole 16mm including removal of old broken insulators. Make :- MYSORE/ BHEL/ PORCELAIN / JAIPURIA BROS.
Supply & fixing in replacement shackle type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut 75 mm height, 90 mm dia for 1100 volts grade, including removal of existing insulators. Make :- MYSORE/ BHEL/ PORCELAIN/ JAIPURIA BROS.
Supply & fixing in replacement pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade, including removal of existing insulators. Make :- MYSORE/ BHEL/ PORCELAIN/ JAIPURIA BROS.
Fixing of ACSR conductor, removed under relevant items on existing or new LT poles including binding with 02 mm dia aluminium binding wire all as specified and directed by Engineer-in-charge.
Supply & fixing in replacement ACSR conductor of any size including binding on existing LT poles or new poles with 02 mm dia aluminium binding wire all as specified & directed by the Engineer-in-charge. Make of ACSR : ICC/ NICCO/ BHARAT CONDUCTORS.
Supply, fabricating and fixing in replacement of cross arms (any type) supports, bracting, stiffness etc made out of MS channel, angle iron, flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint all as directed by Engineer-in-charge.
Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces including broken of existing PCC all as specified & directed.
All as per srl item No 13 here-in-before but PCC 1:3:6 type C-2 as in foundation of stays and coping of poles.
Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth for LT cables complete including bricks all as specified & directed.
Returning, filling in, including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed.
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches/ducts complete all as specified & directed.
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat/lengthwise perpendicular to the axis of cable all as specified & directed.
Supply and laying in replacement of OH ACSR Conductor / XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 10 Sq mm 4 core all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs.
All as per Ser item No 20 here-in-before but 16 Sq mm 4 core
All as per Ser item No 20 here-in-before but 25 Sq mm 4 core
All as per Ser item No 20 here-in-before but 50 Sq mm 3.5 core
All as per Ser item No 20 here-in-before but 95 Sq mm 3.5 core
All as per Ser item No 20 here-in-before but 120 Sq mm 3.5 core
All as per Ser item No 20 here-in-before but 185 Sq mm 3.5 core
All as per Ser item No 20 here-in-before but 240 Sq mm 3.5 core
Supply and fixing 1100 volt grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connectiuons suspended by insulating hangers not more than 1 meter apart including 4 mm dia suspension wire, one twin core cable flat or circular of size 10 Sqmm all as specified.
Taking down of old aluminium conductor of any description /size from LT Poles including cross arms, bracing and other steel accessories.
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge.
Supply and fixing/laying of galvanized iron strip of size 32x6 mm as earth continuity conductor provided in between earth test point terminal and upto the equipment incl nuts, bolts and washers complete all as specified and directed.Note: Making of earth test point is also included in the quoted rate.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
M&L Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed.
M&L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 80/50 mm bore at the depth not less than 1 mtr below ground level for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measure and paid separately under respective item.
S & F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. (a) 50 mm dia
(b) 80 mm dia
Supply and fixing of PVC LT OH line spacer for 3 wires complete all as specified and directed.
Supply and fixing of PVC LT OH line spacer for 4 wires complete all as specified and directed.
Supply and fixing of PVC LT OH line spacer for 2 wires complete all as specified and directed.
Removal of Tree fallen on HT/LT overhead lines by cutting branches,bushes by electric cutter or manual and lifted by crane /Hydra/Manual including collection and depositing the retrieved timber at a place as directed by Engineer-in-charge.
Opening the binding wire from pin /shackle insulator on steel pole of any height for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the pin /shackle insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- charge. Note: (i) The above work includes clearing /prooning of tree branches falling around the conductors. (ii) Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid.
Opening the binding wire from 'J' hook or opening nut, bolts,of cross arms on steel /pole of any height for re-stretching the galvanised iron earth wire any size, after re-restretching without kinks & bends, binding the 'J' hook with appropriate size of aluminium binding wire or fixing with appropriate size of nut,bolts,washers complete all specified & directed by Engineer-in- charge. Note: (i) Cost of binding wire,nut,bolts and washers deemed to be included in the quoted rate, No extra amount will be paid.
Supply, fixing, testing and commissioning of epoxy type straight through jointing kit suitable for LT cable of size 35 Sqmm to 70 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade. Make :- ENSON/ M-SEAL/ FRONTEC
All as per set item No 44 here-in-before but 95 to 120 Sqmm.
All as per set item No 44 here-in-before but 150 to 185 Sqmm.
Supply& fixing in repair PVC jumper cable of size 70 Sqmm aluminium,single core suitable for 1100 volts and removing the old burnt/ worn out jumper complete all as directed by the Engr-in-Charge.
All as per item No 47 here-in-before but & size 95 Sqmm.
M & L fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 300 mm duly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way open ing duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 250 Amp 35 KA (Make Havells /Standard) complete all as sepcified and directed incl making connection /thimbles etc complete.
All as per srl item No 49 here-in-before but of size 600 mm x 600 mm x 300 mm and without MCCB
Supply and fixing street light bracket made out of 40 mm dia GI pipe light grade of length upto 1.2 mtr bent to shape required with and including 2 Nos, 50 x 6 mm MS flat iron clamps with nuts, bolts, washer etc and applying one coat of aluminium paint to clamps including dismantling of old brackets complete all as specified and directed.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the over head lines conductor upto 3 mtr from furthest conductor on pole and pole to pole one span including removing of cut branches and cleaning of site complete all as specified and directed. Note :- (a). The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b). Prooning of all tree branches in one tree shall be measured as one Job. c). Contractor will employ sufficient labour to complete the job with in time as directed. (d). Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e). Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply . However full assistance will be provided by MES staff. (f). The contractor will provide proper tools and safety devices to his staff for prooning of trees.
Cleaning of surrounding areas from large grass weeds ,vegetation, shrubs branches of trees at substations, near Transformers ,near Electric pole structures by manual /Electric Grass cutting machine/JCB etc with complete grass and vegetation clearance from ground without any damage to the electric cables and items complete all as specified and as directed by Engr-in-Charge. Notes: Rates of T&P must be included in the quoted rates
Cleaning and preparation of old painted surface of old painted surface of LT steel tubular pole complete and painting with one coat of aluminium paint including channels/brackets,street light brackets.cross arms and making Red & white strips with synthetic enamelled paint of 30cm height,each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coat of white wash on PCC coping complete all as specified
Notes:- 1.The time limit for attending the job/complaints complaints within 24 hour. 2. In case the contracts fails to attend/rectify the defects within the above time limit, penalty will the imposed as under:- (a) Rs100/- per day per complaints for first seven days after that Rs 1000/- per day per complaint. 3. The contractor or his authorised representative shall submit daily report to the Engineer-in-charge or concered JE at 0900 hour daily on all working days to receive order/instructions of the work.
Ishtiaq and Sons
RAZA ENTERPRISES
shahji contractors
M/S HINA ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .