| 1 | L1₹8.9 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L1 | Accepted-AOC THE LOWEST BIDDER | |
| 2 | L2₹9.9 L+₹41,410 (4.37%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
7 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) CHILODA
VAYU SHAKTI NAGAR CHILODA- 382042
COMPREHENSIVE MAINT/ REPAIR OF SUMMER APPLIANCES AT SEC 25 AND SEC 27 OF GANDHINAGAR UNDER GE (AF) CHILODA
2021_MES_441929_1
8915
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GANDHINAGAR
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (AF) CHILODA
₹30,000
Yes
23 Jul 2021
12 May 2021
9 Jun 2021
12 May 2021
7 Jun 2021
26 May 2021
60 days
Amount
M&L for repair/ maintenance/ servicing of water coolers of any type with replacement of defective minor spare parts such as connector, burn contol copper cable, copper thimbles etc or if any other required minor spares at 258 SU/ 857 SU at Sector-27 and 3 AFSB at Sector-25, Gandhinagar including taking out old u/s water cooler with disconnecting electrical/ mechanical connection and transporting to workshop for repairing & testing after repair entire satisfaction of Engineer-in-Charge and transporting back, fixing to its original location complete with making electical connection complete all as specified and as directed. Note:- Defective major components/ spares if required to be replaced shall be measured as supply only under respective items and labour element included in this item for replacement.
Supply only compressor for 40/ 80 Ltr capacity water cooler.
Supply only compressor for 60/ 120 Ltr capacity water cooler.
Supply only starting relay for water cooler of any type.
Supply only overload for water cooler of any type.
Supply only running capacitor 10/ 15/ 20 mfd for water cooler of any type.
Supply only starting capacitor 40/ 60, 80/ 100 mfd for water cooler of any type.
Supply only push cock copper alloy chromium plated 15 mm bore match to the existing one.
Supply only fan blade for water cooler blower motor of any type (as per existing sample).
Supply only blower motor 1/ 10HP, single phase, 230 volt match to the existing one.
Supply only blower motor 1/ 35HP, single phase, 230 volt match to the existing one.
Supply only thermostat as per existing sample.
Supply only waste water PVC pipe with clamp suitable to existing size.
Supply only chromium plated water tray basin for water cooler match to the existing size.
Suppy and replacement old u/s 15mm dia PTMT float ball valve for water cooler and desert cooler complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of old u/s PVC connection pipe 15 mm dia 450/ 600 mm long with brass fly nut at both ends for water cooler and desert cooler complete all as specified and as directed by Engr-in-Charge.
M&L for repair to water cooler body by replacing worn out metal sheet, with S/S metal sheet and frame of existing thickness at bottom and side including welding/ soldering where ever applicable, painting with one coat of anti corrosive paint and two coats of synthetic paint complete all as specified and as directed by Engr-in-Charge.
M&L for repair/ maintenance of Air Conditioner of any type with replacement of defective minor spare parts such as connector, burn contol copper cable, copper thimbles, cutting, grinding and welding etc or if any other required minor spares at 258 SU/ 857 SU at Sector-27 and 3 AFSB at Sector-25, Gandhinagar including taking out old u/s Air conditioner with disconnecting electrical/ mechanical connection and transporting to workshop for repairing & testing after repair entire satisfaction of Engineer-in-Charge and transporting back, fixing to its original location complete with making electical connection complete all as specified and as directed. Note:- Defective major components/ spares if required to be replaced shall be measured as supply only under respective items and labour element included in this item for replacement.
Supply only compressor Split/ window type AC 1.5 Ton.
Supply only compressor Split/ window type AC 2.0 Ton.
Supply only running capacitor 36 or 50 + 6 mfd.
Supply only starting contactor for split AC of any capacity as per existing sample.
Supply only starting relays with overload suitable for Split/ window AC as per existing sample.
Supply only thermostate as per existing sample for Split/ window AC.
Supply only air filter as per sample for Split/ window AC of any capacity.
Supply only indoor unit blower motor for Split AC of any capacity as per existing sample.
Supply only outdoor unit blower motor for Split AC of any capacity as per existing sample.
Supply only swing motor for Split AC of any capacity as per existing sample.
Supply only aluminium blower impeller for Split/ window AC as per existing sample.
Supply only suction/ discharge service valve as per sample for Split AC of any type.
Supply only cooling/ condenser coil suitable for split type AC of any type.
Supply only PCB with remote as per existing sample for window/ split type AC.
S&F in replacement old unsv indoor unit of split AC 1.5 Ton with heat exchange coil, filter, evoporator motor with blower, PCB with display, swing motor etc. complete all as specified and as directed by Engr-in-Charge.
Disconnecting & taking out of split AC indoor and out door unit by cutting of copper tube and disconnecting of electric cable & shifting of indoor/ outdoor unit to another or same location with refilling refrigerant gas and fixing & testing after connecting all the parts in position complete all as specified and as directed by Engr-in-Charge.
M&L for factory made MS bracket duly painted suitable for split AC outdoor unit of any type.
M&L for cleaning & washing of window/ split AC any type with air blower, brush, chemical, water etc. incl taking down and refixing in position of AC complete all as specified and as directed.
Supply and replacement of old u/s remote control suitable to existing window/ split type ACs (as per sample) complete all as specified and as directed.
S&F in replacement old unsv outdoor unit of split AC 1.5 Ton with condensor coil, condensor motor with blower, compressor, suction & discharge service valve etc. complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of industrial type sheet metal enclosures with a two pin and earth plug and socket, 250 volts with including 16/ 20 Amp, SP 230 Volts complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of 6 pin, 5/ 16 amp multiple switch socket combination with switch flush type complete all as specified and as directed by Engr-in-Charge.
S&F in replacement switch socket combination, 2 in 1, 3/ 5 pin, 5/ 6 Amps, 240 Volt, flush type complete all as specified and as directed.
S&F in replacement of 10-20 Amp MCB SP complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of 5 Amp plug top complete all as specified and as directed by Engr-in-Charge.
S&F Plug top (male) 16 Amps for sheet metal enclosure (As per sample) complete all as specified and as directed by Engr-in-Charge.
M&L for point wiring with 1.5 Sqmm FRLS PVC insulated unsheathed multistranded single core copper conductor cable in PVC concealed conduit and chases cutting incl MS sheet pressed terminal box (recessed) with 3mm thick laminated hylem top cover incl 1.5 Sqmm PVC insulated copper conductor earth continuity wire for socket outlet point on independent board including taking out old point wiring complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of old u/s point wiring with 2.5 Sqmm FRLS PVC insulated unsheathed multistranded single core copper conductor cable in PVC concealed conduit and chases cutting incl MS sheet pressed terminal box (recessed) with 3mm thick laminated hylem top cover incl 2.5 Sqmm PVC insulated copper conductor earth continuity wire for socket outlet point on independent board complete all as specified and as directed.
S&F in replacement of old u/s sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4.0 Sqmm of voltage rating upto and including 1100 Volts drawn in existing PVC conduit alongwith one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm as earth continuity conductor complete all as specified and as directed.
S&F in replacement of old u/s round PVC insulated stranded copper conductor 3 core 2.5 Sqmm 1100 Volt grade, connected & testing complete all as specified and as directed.
S&F in replacement of old u/s nitrile rubber insulation material for split air conditioner copper tube of any size complete all as specified and as directed by Engineer-in-Charge.
S&F Plywood 4 mm thick, grade BWR, type BB, fixing for window AC/ desert cooler complete all as specified and as directed.
Supply and filling putty in air gap of ACs complete all as specified and as directed.
M&L for repair/ maintenance/ servicing of Refrigerator or Deep freezer of any type with replacement of defective minor spare parts such as connector, burn contol copper cable, copper thimbles, cutting, grinding and welding etc or if any other required minor spares at 258 SU/ 857 SU at Sector-27 and 3 AFSB at Sector-25, Gandhinagar including taking out old u/s Refrigerator or Deep freezer with disconnecting electrical/ mechanical connection and transporting to workshop for repairing & testing after repair entire satisfaction of Engineer-in-Charge and transporting back, fixing to its original location complete with making electical connection complete all as specified and as directed. Note:- Defective major components/ spares if required to be replaced shall be measured as supply only under respective items and labour element included in this item for replacement.
Supply only compressor unit for refrigerator 165 to 250 Ltr capacity of any type.
Supply only compressor unit for refrigerator 260 to 330 Ltr capacity of any type.
Supply only compressor unit for deep freezer 400 to 500 Ltr capacity of any type.
Supply only cooling coil evaporator assembly as per sample for refrigerator of any capacity.
Supply only condensing coil assembly as per sample for refrigerator of any capacity.
Supply only thermostat switch as per sample for Refrigerator or Deep freezer of any capacity.
Supply only starting relay with OLP as per sample for Refrigerator or Deep freezer.
Supply only timer as per sample for double door refrigerator of any capacity.
Supply only biometer as per sample for double door refrigerator of any capacity.
Supply only blower motor with fan as per sample for double door refrigerator or Deep freezer of any capacity.
Supply only freezer cheast door as per sample for any capacity refrigerator.
Supply only transparent vegetable tray as per sample for any capacity refrigerator.
Supply only electronic PCB as per sample for any capacity refrigerator.
M&L for charging refrigerant gas R22 or R410 or R32 in old or new AC compressor and makeup required pressure including brazing and testing complete all as specified and as directed.
M&L for charging refrigerant gas R-134a or R-600a in old or new compressor and makeup required pressure including brazing and testing complete all as specified and as directed.
S&F in replacement of capillary tube (copper) match to the existing size & length including taking down and removal of old unserviceable one complete all as specified and as directed.
S&F in replacement of old u/s filter flare nipple for refrigerator/ deep freezer.
S&F in replacement of old u/s filter flare nipple for water cooler/ Acs.
S&F in replacement old unsv copper pipe ½" as per sample.
S&F in replacement old unsv copper pipe ¼" as per sample.
S&F in replacement old unsv copper pipe 5/8" as per sample.
S&F in replacement old unsv copper pipe 5/16" as per sample for Refrigerator.
Taking out desert cooler of any size and capacity from existing site for repair with replacement of defective minor spare parts such as PVC water distributor, tee, bend, elbow, holding clamp, nut, bolt, washer, connector, burn contol copper cable, copper thimbles etc or if any other required minor spares at 258 SU/ 857 SU at Sector-27 and 3 AFSB at Sector-25, Gandhinagar including transporting to workshop for repairing & testing after repair entire satisfaction of Engineer-in-Charge and transporting back, fixing to its original location complete with making electical connection complete complete all as specified and as directed. Note:- Defective major components/ spares if required to be replaced shall be measured as supply only under respective items and labour element included in this item for replacement.
Supply only desert cooler blower motor 1275 RPM of any capacity as per existing sample operate in three speed, single phase 220 Volt complete all as specified and as directed. Make:- Khaitan/ Bajaj/ Sympony/ Ken star/ CG as approved by GE.
Supply only water lifting submersible pump single phase 165-250 Volts, 18 Watt complete or if any as per existing sample complete all as specified and as directed.
Supply only honycomb pad set (as per sample) complete all as specified and as directed.
Supply only capacitor 4.0 mfd for desert cooler Make:- Havells/ Asian/ Apcos/ Bajaj as approved by GE.
Supply only GI sheet front grill with flexible louvers match to existing size complete all as specified and as directed.
Supply only GI sheet side grill match to existing size complete all as specified and as directed.
Supply only water tank made out 22 gauge GI sheet match to existing size.
Supply only three way speed control switch for desert cooler (as per existing sample) complete all as specified and as directed.
Supply only fan blade for desert cooler (as per existing sample) complete all as specified and as directed.
Supply only piano type switch 5 Amp complete all as specified and as directed.
Supply only three pin plug with PVC flexible cable lead as per sample for desert cooler complete all as specified and as directed.
Supply only PVC flexible pipe 15mm dia as per sample complete all as specified and as directed.
S&F in replacement of wood wool pad set of three (as per sample) complete all as specified and as directed.
M&L for preparation for old painted surface of desert cooler exterior including applying two coats of approved colour by spray gun and applying one coats of bituminious paint on desert cooler water tank complete all as specified and as directed by Engr-in-Charge.
S&F in replacement fabrication frame work for voltage stabilizer, water cooler, window AC, desert cooler made from angle iron, flat iron,square tube, wire mesh, GI sheet etc. quality confirming to Fe-410-W or Gde-E 250 quality A with including drilling holes, cutting & welding nut & bolts etc. complete with locking arrangement, grouting in wall/ floors etc. and make good the disturbed surfaces incl required cement/ bricks etc complete all as specified and as directed by Engr-in-Charge.
M&L for writing SM No/ MES No on refrigerator/ deep freezer/ water cooler/ desert cooler and AC side & back surfaces with paint/ sticker size & colour as per standard Engineering practice complete all as specified and as directed by Engr-in-Charge.
Repair/ replacement of voltage stabilizer of upto 2 KVA of any type including replacement of spare parts such as transistor, PCB, diode, transformer, preset ic, volt meter, ampmeter, indicator lamp, socket outlet and any other parts as required for proper functioning of stabilizer complete along with testing and transportation charges from site to workshop complete all as specified and as directed.
All as per above item No 92 but capacity 3 KVA.
All as per above item No 92 but capacity 4 or 5 KVA.
Disconnecting & taking up or down the existing old solar flat/ tubular collector of any description for cleaning the glass by washing with using soft detergent, cleaning & de-scaling the inside surface of copper fins/ tubes with circulating concentrated de-scaling solution complete deposits/ scale is removed and reassembling the solar system after servicing/ maintenance including nuts, bolts & washers, gaskets etc. fixing & installation in position and testing complete all as specified and as directed.
S&F in replacement of old u/s water heating element of capacity 2.0 or 3.0 KW for solar water heater complete all as specified and as directed. Make:- Hotzone/ Theeta/ Elcon as approved by GE.
S&F in replacement of old u/s thermostat for solar water heater complete all as specified and as directed. Make:- Hotzone/ Theeta/ Elcon as approved by GE.
S&F in replacement of old u/s evacuated tubes twin borosilicate glass collector for solar water heater (length and size as per existing sample) complete all as specified and as directed.
S&F in replacement of old u/s stop valves suitable for 15 mm bore of pipe, fancy type, chromium plated, screwed of both ends complete all as specified and as directed.
S&F in replacement of old u/s 15mm bore GI pipe, medium grade, fixed on floor/ wall with all fittings complete all as specified and as directed.
ALBA AC AND REF SERVICES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .