| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹75.0 CrAccepted-AOC 301 306 PANORAMA COMPLEX R C DUTT ROAD VADODARA VADODARA GUJARAT 390007 | VADODARA | GUJARAT | 390007 | ₹75.0 Cr | 1st | Accepted-AOC 1st Lowest |
| 2 | 2nd₹77.8 CrRejected-Finance | ₹77.8 Cr | 2nd | Rejected-Finance Due to 2nd Lowest |
| 3 | 3rd₹85.8 CrRejected-Finance | ₹85.8 Cr | 3rd | Rejected-Finance Due to 3rd Lowest |
Tender Value
₹71.5 Cr
EMD Value
₹1.4 Cr
Closing Date
7 Apr 2025, 5:00 pmClosed
DGM Transmission Division TPTL Agartala
Office of the DGM Transmission Division TPTL Agartala
As per Bid Document
2024_POWER_56017_1
DGM/TD/AGT/NIeT/24-25/03 Dt. 16.12.2024
Open Tender
Electrical Works
365 days
Tripura
As per Bid Document
5 documents required · 5 mandatory
₹35,000
TSECL Settlement Centralised Account
₹1.4 Cr
Office of the DGM Transmission Division Agartala
7 Jul 2025
18 Dec 2024
9 Apr 2025
18 Dec 2024
7 Apr 2025
6 Jan 2025
19 Dec 2024 - 31 Dec 2024
2 Jan 2025
Amount
SECTION - I. GROUP-A (SUPPLY) Surjamaninagar (TSECL) - LILO Point of Surjamaninagar (ISTS)
HTLS Panther type conductor ( Carbon fiber composit carbon core type)
Hardware Suitable for Composite Carbon Core type HTLS Conductor
Single Suspension Fittings
Single Tension Fittings
Double Suspension Fittings
Double Tension Fittings
Single Suspension Fittings for pilot String
Conductor Accessories for Carbon Core type HTLS Conductor
VIBRATION DAMPER FOR HTLS PANTHER SIZE COUNDUCTOR
MID SPAN COMPRESSION JOINT FOR HTLS PANTHER SIZE COUNDUCTOR
REPAIR SLEEVE FOR HTLS PANTHER SIZE COUNDUCTOR
Preformed armoured rod for suspension location
Tee Connector & Other Accessories
Single Rod Composite (SRC) Insulator
90 KN Composite long rod Insutator for 132KV
120 KN Composite long rod Insutator for 132KV
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
GROUP-B (ERECTION, TESTING & COMMISSIONING)
Survey of Existing Line (Check Survey)
De-stringing of ACSR Conductor & Re-stringing of HTLS Conductor
Destringing of existing 132 kV S/C line and transportation to store
Reconductoring of 132 KV S/C transmission line with 03 Phase HTLS Conductor (without OPGW/ Eartwire) complete with all works including stringing of Conductor, Fitting of Hardwares, Hoisting of Insulators etc.
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
GROUP-C (T & P for HTLS Conductor) ( Ambassa to Kamalpur section)
Sagging bridge/Platform (16 mtr.)
Aluminium Comealong clamp
Sky Roller
PP Rope for sky roller- 12 mm (500 mtr.)
PP Rope for sky roller- 16 mm (500 mtr.)
Pilot Rope (per meter)
Ladder ( 8 mtr.)
Running block for Conductor
SWIVEL-5T
Ground roller 600 mm for tension/manual stringing
Wire mesh pulling grip (Pulling socks)
Drum mounting jack for conductor drum
Hydraulic compression machine with die sets
Pulley single 5 T capacity
Pulley double 5 T capacity
Winch-Motorised 5 T capacity
Hydraulic wire cutter machine
Nylon rollers
Tandem
Chain Pully (Manual) 3 T capacity
Chain Pully (Manual) 5 T capacity
Digital Micro-Ohm Meter Along with Suitable Probes
Puncture Insulator Detection Test Kit
SF6 Gas Dew Point Meter
Automatic 3rd Harmonic Resistance Measurement Kit for Gapless Surge Arrester
Automatic Battery Discharge Kit
Mobile Dry Air Plant (Heatless Type)
Sweep Frequency Response Analyser
SF6 Gas Handling Plant
Transformer Winding Resistance Meter
Thermo Vision Camera for Detection of Hot Spots
Off Line Overhead Transmission Line Fault Locator
Isulation Resistance (IR) tester (portable & Fully Automatic)
GROUP-D (SCRAP MATERIALS )
Cost of existing old ACSR Panther Conductor to be dismantled from line (Owner will not take back old Conductor)
SECTION - II. GROUP-A (SUPPLY) Bodhjungnagar (TSECL) to LILO Point of Surjamaninagar (ISTS)
HTLS Panther type conductor ( Carbon fiber composit carbon core type)
Hardware Suitable for Composite Carbon Core type HTLS Conductor
Single Suspension Fittings
Single Tension Fittings
Double Suspension Fittings
Double Tension Fittings
Single Suspension Fittings for pilot String
Conductor Accessories for Carbon Core type HTLS Conductor
VIBRATION DAMPER FOR HTLS PANTHER SIZE COUNDUCTOR
MID SPAN COMPRESSION JOINT FOR HTLS PANTHER SIZE COUNDUCTOR
REPAIR SLEEVE FOR HTLS PANTHER SIZE COUNDUCTOR
Preformed armoured rod for suspension location
Tee Connector & Other Accessories
Single Rod Composite (SRC) Insulator
90 KN Composite long rod Insutator for 132KV
120 KN Composite long rod Insutator for 132KV
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
GROUP-B (ERECTION, TESTING & COMMISSIONING)
Survey of Existing Line (Check Survey)
De-stringing of ACSR Conductor & Re-stringing of HTLS Conductor
Destringing of existing 132 kV S/C line and transportation to store
Reconductoring of 132 KV S/C transmission line with 03 Phase HTLS Conductor (without OPGW/ Eartwire) complete with all works including stringing of Conductor, Fitting of Hardwares, Hoisting of Insulators etc.
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
GROUP-C (SCRAP MATERIALS )
Cost of existing old ACSR Panther Conductor to be dismantled from line (Owner will not take back old Conductor)
SECTION - III. GROUP-A Surjamaninagar (TSECL) to Bodhjungnagar (TSECL)
HTLS Panther type conductor ( Carbon fiber composit carbon core type)
Hardware Suitable for Composite Carbon Core type HTLS Conductor
Single Suspension Fittings
Single Tension Fittings
Double Suspension Fittings
Double Tension Fittings
Single Suspension Fittings for pilot String
Conductor Accessories for Carbon Core type HTLS Conductor
VIBRATION DAMPER FOR HTLS PANTHER SIZE COUNDUCTOR
MID SPAN COMPRESSION JOINT FOR HTLS PANTHER SIZE COUNDUCTOR
REPAIR SLEEVE FOR HTLS PANTHER SIZE COUNDUCTOR
Preformed armoured rod for suspension location
Tee Connector & Other Accessories
Single Rod Composite (SRC) Insulator
90 KN Composite long rod Insutator for 132KV
120 KN Composite long rod Insutator for 132KV
EARTHING OF TOWERS Supply of earthing of towers
Pipe Type
Fabrication, galvanising & supply of various types of towers & tower parts, tower/leg extensions (complete) excluding stubs and bolts & nuts but including hangers, D-Shackles, pack washers etc - For Normal Towers. MS Steel
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
GROUP-B (ERECTION, TESTING & COMMISSIONING)
Survey of Existing Line (Check Survey)
De-stringing of ACSR Conductor & Re-stringing of HTLS Conductor
Destringing of existing 132 kV S/C line and transportation to store
Reconductoring of 132 KV S/C transmission line with 03 Phase HTLS Conductor (without OPGW/ Eartwire) complete with all works including stringing of Conductor, Fitting of Hardwares, Hoisting of Insulators etc.
INSTALLATION OF EARTHING OF TOWERS
Pipe Type
Erection of various types of Towers, Gantries & Tower Parta, Gantry Parts, Tower Extensions (Complete), Bolts & Nuts, Hangers, D-6hackIes, Step Bolts, Pack Washers etc. including tack welding & supply & application of Zinc Rich Primer & Enamel Paint Normal Towers
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
GROUP-C (SCRAP MATERIALS )
Cost of existing old ACSR Panther Conductor to be dismantled from line (Owner will not take back old Conductor)
SECTION - IV. GROUP-A. Ambassa (TSECL) to LILO Point of P.K. Bari (ISTS) via Manu (TSECL)
HTLS Panther type conductor ( Carbon fiber composit carbon core type)
Hardware Suitable for Composite Carbon Core type HTLS Conductor
Single Suspension Fittings
Single Tension Fittings
Double Suspension Fittings
Double Tension Fittings
Single Suspension Fittings for pilot String
Conductor Accessories for Carbon Core type HTLS Conductor
VIBRATION DAMPER FOR HTLS PANTHER SIZE COUNDUCTOR
MID SPAN COMPRESSION JOINT FOR HTLS PANTHER SIZE COUNDUCTOR
REPAIR SLEEVE FOR HTLS PANTHER SIZE COUNDUCTOR
Preformed armoured rod for suspension location
Tee Connector & Other Accessories
Single Rod Composite (SRC) Insulator
90 KN Composite long rod Insutator for 132KV
120 KN Composite long rod Insutator for 132KV
EARTHING OF TOWERS Supply of earthing of towers
Pipe Type
Fabrication, galvanising & supply of various types of towers & tower parts, tower/leg extensions (complete) excluding stubs and bolts & nuts but including hangers, D-Shackles, pack washers etc - For Normal Towers. MS Steel
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
GROUP-B (ERECTION, TESTING & COMMISSIONING)
Survey of Existing Line (Check Survey)
De-stringing of ACSR Conductor & Re-stringing of HTLS Conductor
Destringing of existing 132 kV S/C line and transportation to store
Reconductoring of 132 KV S/C transmission line with 03 Phase HTLS Conductor (without OPGW/ Eartwire) complete with all works including stringing of Conductor, Fitting of Hardwares, Hoisting of Insulators etc.
INSTALLATION OF EARTHING OF TOWERS
Pipe Type
Erection of various types of Towers, Gantries & Tower Parta, Gantry Parts, Tower Extensions (Complete), Bolts & Nuts, Hangers, D-6hackIes, Step Bolts, Pack Washers etc. including tack welding & supply & application of Zinc Rich Primer & Enamel Paint Normal Towers
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
GROUP-C (SCRAP MATERIALS )
Cost of existing old ACSR Panther Conductor to be dismantled from line (Owner will not take back old Conductor)
SECTION - V. GROUP-A. P.K. Bari (TSECL) to LILO Point of P.K. Bari (ISTS)
HTLS Panther type conductor ( Carbon fiber composit carbon core type)
Hardware Suitable for Composite Carbon Core type HTLS Conductor
Single Suspension Fittings
Single Tension Fittings
Double Suspension Fittings
Double Tension Fittings
Single Suspension Fittings for pilot String
Conductor Accessories for Carbon Core type HTLS Conductor
VIBRATION DAMPER FOR HTLS PANTHER SIZE COUNDUCTOR
MID SPAN COMPRESSION JOINT FOR HTLS PANTHER SIZE COUNDUCTOR
REPAIR SLEEVE FOR HTLS PANTHER SIZE COUNDUCTOR
Preformed armoured rod for suspension location
Tee Connector & Other Accessories
Single Rod Composite (SRC) Insulator
90 KN Composite long rod Insutator for 132KV
120 KN Composite long rod Insutator for 132KV
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
EARTHING OF TOWERS Supply of earthing of towers
Pipe Type
Fabrication, galvanising & supply of various types of towers & tower parts, tower/leg extensions (complete) excluding stubs and bolts & nuts but including hangers, D-Shackles, pack washers etc - For Normal Towers. MS Steel
GROUP-B (ERECTION, TESTING & COMMISSIONING)
Survey of Existing Line (Check Survey)
De-stringing of ACSR Conductor & Re-stringing of HTLS Conductor
Destringing of existing 132 kV S/C line and transportation to store
Reconductoring of 132 KV S/C transmission line with 03 Phase HTLS Conductor (without OPGW/ Eartwire) complete with all works including stringing of Conductor, Fitting of Hardwares, Hoisting of Insulators etc.
INSTALLATION OF EARTHING OF TOWERS
Pipe Type
Erection of various types of Towers, Gantries & Tower Parta, Gantry Parts, Tower Extensions (Complete), Bolts & Nuts, Hangers, D-6hackIes, Step Bolts, Pack Washers etc. including tack welding & supply & application of Zinc Rich Primer & Enamel Paint Normal Towers
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
GROUP-C (T & P for HTLS Conductor) ( Ambassa to Kamalpur section)
Sagging bridge/Platform (16 mtr.)
Aluminium Comealong clamp
Sky Roller
PP Rope for sky roller- 12 mm (500 mtr.)
PP Rope for sky roller- 16 mm (500 mtr.)
Pilot Rope (per meter)
Ladder ( 8 mtr.)
Running block for Conductor
SWIVEL-5T
Ground roller 600 mm for tension/manual stringing
Wire mesh pulling grip (Pulling socks)
Drum mounting jack for conductor drum
Hydraulic compression machine with die sets
Pulley single 5 T capacity
Pulley double 5 T capacity
Winch-Motorised 5 T capacity
Hydraulic wire cutter machine
Nylon rollers
Tandem
Chain Pully (Manual) 3 T capacity
Chain Pully (Manual) 5 T capacity
Digital Micro-Ohm Meter Along with Suitable Probes
Puncture Insulator Detection Test Kit
SF6 Gas Dew Point Meter
Automatic 3rd Harmonic Resistance Measurement Kit for Gapless Surge Arrester
Automatic Battery Discharge Kit
Mobile Dry Air Plant (Heatless Type)
Sweep Frequency Response Analyser
SF6 Gas Handling Plant
Transformer Winding Resistance Meter
Thermo Vision Camera for Detection of Hot Spots
Off Line Overhead Transmission Line Fault Locator
Isulation Resistance (IR) tester (portable & Fully Automatic)
GROUP-D (SCRAP MATERIALS )
Cost of existing old ACSR Panther Conductor to be dismantled from line (Owner will not take back old Conductor)
SECTION - VI. GROUP-A. P.K. Bari (TSECL) to Kumarghat (PGCIL)
HTLS Panther type conductor ( Carbon fiber composit carbon core type)
Hardware Suitable for Composite Carbon Core type HTLS Conductor
Single Suspension Fittings
Single Tension Fittings
Double Suspension Fittings
Double Tension Fittings
Single Suspension Fittings for pilot String
Conductor Accessories for Carbon Core type HTLS Conductor
VIBRATION DAMPER FOR HTLS PANTHER SIZE COUNDUCTOR
MID SPAN COMPRESSION JOINT FOR HTLS PANTHER SIZE COUNDUCTOR
REPAIR SLEEVE FOR HTLS PANTHER SIZE COUNDUCTOR
Preformed armoured rod for suspension location
Tee Connector & Other Accessories
Single Rod Composite (SRC) Insulator
90 KN Composite long rod Insutator for 132KV
120 KN Composite long rod Insutator for 132KV
EARTHING OF TOWERS Supply of earthing of towers
Pipe Type
Fabrication, galvanising & supply of various types of towers & tower parts, tower/leg extensions (complete) excluding stubs and bolts & nuts but including hangers, D-Shackles, pack washers etc - For Normal Towers. MS Steel
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
GROUP-B (ERECTION, TESTING & COMMISSIONING)
Survey of Existing Line (Check Survey)
De-stringing of ACSR Conductor & Re-stringing of HTLS Conductor
Destringing of existing 132 kV S/C line and transportation to store
Reconductoring of 132 KV S/C transmission line with 03 Phase HTLS Conductor (without OPGW/ Eartwire) complete with all works including stringing of Conductor, Fitting of Hardwares, Hoisting of Insulators etc.
INSTALLATION OF EARTHING OF TOWERS
Pipe Type
Erection of various types of Towers, Gantries & Tower Parta, Gantry Parts, Tower Extensions (Complete), Bolts & Nuts, Hangers, D-6hackIes, Step Bolts, Pack Washers etc. including tack welding & supply & application of Zinc Rich Primer & Enamel Paint Normal Towers
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator with one E/S
145 kV,2500 A,31.5 KA,3-phase Double Break Isolator without E/S
145 kV, 1600A, 31.5KA, 1-Phase Current Transformer with 120% extended current rating
GROUP-C (T & P for HTLS Conductor) ( Ambassa to Kamalpur section)
Sagging bridge/Platform (16 mtr.)
Aluminium Comealong clamp
Sky Roller
PP Rope for sky roller- 12 mm (500 mtr.)
PP Rope for sky roller- 16 mm (500 mtr.)
Pilot Rope (per meter)
Ladder ( 8 mtr.)
Running block for Conductor
SWIVEL-5T
Ground roller 600 mm for tension/manual stringing
Wire mesh pulling grip (Pulling socks)
Drum mounting jack for conductor drum
Hydraulic compression machine with die sets
Pulley single 5 T capacity
Pulley double 5 T capacity
Winch-Motorised 5 T capacity
Hydraulic wire cutter machine
Nylon rollers
Tandem
Chain Pully (Manual) 3 T capacity
Chain Pully (Manual) 5 T capacity
Digital Micro-Ohm Meter Along with Suitable Probes
Puncture Insulator Detection Test Kit
SF6 Gas Dew Point Meter
Automatic 3rd Harmonic Resistance Measurement Kit for Gapless Surge Arrester
Automatic Battery Discharge Kit
Mobile Dry Air Plant (Heatless Type)
Sweep Frequency Response Analyser
SF6 Gas Handling Plant
Transformer Winding Resistance Meter
Thermo Vision Camera for Detection of Hot Spots
Tower footing Resistance Meter (High Frequency)
Data Downloading Equipment for numerical relays (Laptop)
Isulation Resistance (IR) tester (portable & Fully Automatic)
GROUP-D (SCRAP MATERIALS )
Cost of existing old ACSR Panther Conductor to be dismantled from line (Owner will not take back old Conductor)
JSK Industries Pvt. Ltd. (BID ID -171385)
Sterlite Power Transmission Limited (BID ID -162628)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid