Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC | L1 | Accepted-AOC BeingL1 | |
| 2 | L2₹4.1 L+₹4,210 (1.05%)Rejected-AOC KANCHANTULLI SOUTH BADHARGHAT AGARTALA WEST TRIPURA PIN 799014 | WEST TRIPURA | TRIPURA | 799014 | L2 | Rejected-AOC BeingL2 |
Tender Value
Refer Docs
EMD Value
₹4,836
Closing Date
31 May 2021, 3:00 pmClosed
Executive Engineer
Executive Engineer, Mechanical Division, PWD
Annual Maintenance and Incidental repair of ACs and Refrigerators installed in the residence of the Ministers and VIPs of Govt of Tripura
2021_CEPWD_18602_1
06 _EE_DNIeT_MCH_DVN_AGT_21_22
Open Tender
Electrical Works
Item Rate
730 days
Ministers and VIPs of Govt of Tripura
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹4,836
Yes
21 Sept 2021
3 May 2021
31 May 2021
3 May 2021
31 May 2021
3 May 2021
Amount
Providing & Fitting fixing of Capacitor-4 µf as per the direction of the Engineer-in-charge.
Providing & Fitting fixing of Capacitor-6 µf as per the direction of the Engineer-in-charge.
Providing & Fitting fixing of Capacitor-36 µf as per the direction of the Engineer-in-charge.
Providing & Fitting fixing of Capacitor-45 µf as per the direction of the Engineer-in-charge.
Providing & Fitting fixing of Capacitor-50 µf as per the direction of the Engineer-in-charge.
Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c fitting, fixing grouting by cement mixer, painting, as per direction of the Engineer-in-Charge.
Providing & Fitting fixing of evaporator coil for indoor unit per the direction of the Engineer-in-charge.
Providing & Fitting fixing of evaporator coil for indoor unit per the direction of the Engineer-in-charge.
Repairing of PCB Circuit as per the direction of the Engineer-in-charge.
Providing & Fitting fixing of new PCB Circuit (same brand with the machine to be repaired ) as per the direction of the Engineer-in-charge.
Repairing of Burnt BLOWER FAN motor of Split AC unit(1.5/2.0 TR) outdoor unit as per direction of the Engineer-in-charge.
Providing & Fitting fixing of Compressor for 1.5 TR Capacity AC Machine as per the direction of the Engineer-in-charge.
Providing & Fitting fixing of Compressor for 2.0 TR Capacity AC machine as per the direction of the Engineer-in-charge.
Providing remote control unit of Split AC unit(1.5/2.0 TR) with necessary circuit as per direction of the Engineer-in-charge.
Providing & Charging of Non CFC Refrigerant to Split AC (1.5TR/2.0 TR)as per the direction of the Engineer-in-charge.
Providing & Fitting fixing of Compressor for refrigerator(190/210/260 Ltr) as per the direction of the Engineer-in-charge.
Providing, fitting fixing of evaporator /Cooling Coil of refrigerator(190/210/260 Ltr) as per the direction of the Engineer-in-charge.
Providing & fitting fixing of Capillary of refrigerator(190/210/260 Ltr) as per the direction of the Engineer-in-charge.
Providing and fitting fixing of relay overload of refrigerators(190/210/260 Ltr) as per the direction of the Engineer-in-charge.
Providing and fitting fixing of thermostats for refrigerators(190/210/260 Ltr) as per the direction of the Engineer-in-charge.
Providing and fitting fixing of copper pipe(suction& discharge) for split AC (5/8”, ¼’’) / suitable Size as per the direction of the Engineer-in-charge.
Providing & fitting fixing of 1” PVC drain Pipe as per the direction of the Engineer-in-charge.
Providing, fitting fixing of inverter compressor of Split AC unit(1.5 TR) with necessary circuit as per direction of the Engineer-in-charge.
Providing, fitting fixing of inverter compressor of Split AC unit(2.0 TR) with necessary circuit as per direction of the Engineer-in-charge.
Standard installation of 1.5 TR/2.00 TR capacity High Wall Split type type Air Conditioner in/c repairing of drilled wall by cement mortar, painting In/c necessary insulation of copper pipes and also providing electrical 3 pin 16 ampTop for connection in socket & necessary scafolding etc. complete as per direction of the Engineer-in-Charge.
Dismantling and re-installation of Split (1.5/2.0 TR) type AC machine as per the direction of the Engineer-in-charge.
Servicing of Split type AC (1.5 TR & 2.0 TR) washing and cleaning of indoor as well as outdoor unit with pressurised water if necessary & by blower as per direction of the Engineer-In-Charge.
Providing & Charging of gas Non CFC Refrigerant to the refrigerator(190/210/260 Ltr) as per the direction of the Engineer-in-charge.
Providing & Fitting fixing of new PCB Circuit for 1.5/2.0 TR inverter AC (same brand with the machine to be repaired ) as per the direction of the Engineer-in-charge.
Providing, fitting fixing of Evaporator FAN motor of Split AC unit(1.5/2.0 TR) indoor unit as per direction of the Engineer-in-charge.
Providing of Evaporator FAN (Scroll type) of Split AC unit(1.5/2.0 TR) indoor unit as per direction of the Engineer-in-charge.
Providing and connecting Electric Control cables between MCB to indoor/outdoor 3C X 2.5 Sq mm Copper Cable
Engagement of skilled AC mechanic with semi skilled helper for repairing of all types of AC machines at Minister's & VIP's Quarter beyond office hour (in/c night time) and service call has to be attend within a hour after receiving the information through phone or by any means as per direction of Engineer in Charge.
S.D Refrigeration
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_18833.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .