Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.4 LAccepted-AOC | ₹12.4 L | 1 | Accepted-AOC Awarded |
| 2 | 2₹12.5 LRejected-AOC | ₹12.5 L | 2 | Rejected-AOC Not Awarded |
| 3 | 3₹12.7 LRejected-AOC | ₹12.7 L | 3 | Rejected-AOC Awarded |
| 4 | 4₹12.7 LRejected-AOC | ₹12.7 L | 4 | Rejected-AOC Awarded |
Tender Value
₹12.8 L
EMD Value
₹13,000
Closing Date
24 Feb 2020, 5:00 pmClosed
S.E., E.T.C., Bareilly
Superintending Engineer Transmission Campus Near L.I.C. Office Rampur Garden, Bareilly
Replacement of 132KV Jack Bus Bars of Single ACSR Zebra Conductors by Twin ACSR Moose Conductors alongwith other associated Works in 132KV side of 160MVA Transformer - I and II Bays at 220KV Sub Station Dohna under ETD-II, Bareilly
2020_UPTCL_431865_1
E-Tender No. 82 / W / ETC(B) / 2019 - 20
Open Tender
Electrical Works
120 days
Bareilly
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
A/c No 10897666087 IFSC SBIN0000615 S.B.I. Bly
₹13,000
18 Sept 2020
6 Feb 2020
25 Feb 2020
6 Feb 2020
24 Feb 2020
6 Feb 2020
6 Feb 2020 - 24 Feb 2020
Amount
Replacement of 132KV Jack Bus Bars of Single ACSR Zebra Conductors by Twin ACSR Moose Conductors alongwith other associated Works in 132KV side of 160MVA Transformer - I & II Bays at 220KV Sub Station Dohna, with all Cost of Men, Materials (as per Technical Specifications & Sample), Misc. Consumables, T&Ps etc. Required for Satisfactory Completion of the Work as per Technical Specifications and Direction of the Supervising Engineer as per Details below : Supply of 5 No. U- Bolted type Single Tension Fitting Assembly with Turn Buckle, suitable for Twin ACSR Moose Conductors & 132KV Bus Bar Disc Insulator String comprising of 10 No. 70 KN Disc Insulators, complete with Hardware Fittings, D-Shackle, Socket Eye, Ball Link, Yoke Plate, Tension Clamp etc., as per Technical Specifications & Sample.
Supply of 5 No. U-Bolted type Single Tension Fitting Assembly without Turn Buckle, suitable for Twin ACSR Moose Conductors & 132KV Bus Bar Disc Insulator String comprising of 10 No. 70 KN Disc Insulators, complete with Hardware Fittings, D-Shackle, Socket Eye, Ball Link, Yoke Plate, Tension Clamp etc., as per Technical Specifications & Sample.
Supply of 2 No. U-Bolted type Single Suspension Fitting Assembly, suitable for Twin ACSR Moose Conductors & 132KV Disc Insulator String comprising of 9 No. 70 KN Disc Insulators, complete with Hardware Fittings, Socket Eye, Ball Hook, Yoke Plate, J-Hook etc., as per Technical Specifications & Sample.
Supply of Spacer, suitable for 132KV Bus Bar of Twin ACSR Moose Conductors with 250 mm Spacing and duly made of LM-6 Aluminium Alloy, complete with 12 mm dia. HDG Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of PG Clamp duly made of LM-6 Aluminium Alloy, suitable for ACSR Moose to ACSR Moose Conductor, complete with 4 No. 16×90 mm size HDG Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of Bi-Metallic Transformer Bushing Clamp duly made of LM-6 Aluminium Alloy alongwith Bi-Metallic Sleeve, suitable for 132KV Bushing of 160MVA 220/132KV Transformer & Twin ACSR Moose Conductors, complete with 4 No. 12 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of 132KV Isolator Bi-Metallic Terminal Connector duly made of LM-6 Aluminium Alloy, suitable for 132KV Isolator & Twin ACSR Moose Conductors, complete with 4 No. 12 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of 132KV C.B. Terminal Connector duly made of LM-6 Aluminium Alloy, suitable for 132KV C.B. & Twin ACSR Moose Conductors, complete with 4 No. 12 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of 132KV C.T. Bi-Metallic Terminal Connector duly made of LM-6 Aluminium Alloy alongwith Bi-Metallic Sleeve / Plate, suitable for 132KV C.T. & Twin ACSR Moose Conductors, complete with 4 No. 12 mm size G.I. Bolts, Nuts & Spring / Plain Washers, as per Technical Specifications & Sample.
Supply of 132KV Post Insulator Clamp duly made of LM-6 Aluminium Alloy, suitable for 132KV Post Insulator & Twin ACSR Moose Conductors, complete with 4 No. 12 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Opening of existing Jumpers of Single ACSR Zebra Conductor between 132KV Jack Bus Bar Conductors to 132KV Bushings of 160MVA Transformer, 132KV Jack Bus Bar to LAs, CTs, T.I., 132KV T.I. to L.I.; 132KV L.I. to C.B., 132KV C.B. to B.I., 132KV B.I. to 132KV Main Bus, 132KV T.I. to 132KV Transfer Bus in 160MVA Transformer - I & II Bays at the Sub Station alongwith Shifting of the Dismantled Conductors, P.G. Clamps, Equipments Terminal Connectors etc. from Switchyard to Stores at the Sub Station. (1 Job for each Jumper)
De-Stringing & Dismantling of Existing 132KV Jack Bus Bar of Single ACSR Zebra Conductors including De-hoisting of Disc Insulator Tension String with associated Tension Fitting and Disc Insulator Suspension String with associated Suspension Fitting from Gantry in 160MVA Transformers - I & II Bays at the Sub Station alongwith Shifting of the Dismantled Conductors, Tension Fittings, Suspension Fittings etc. from Switchyard to Stores at the Sub Station. (1 Job for each Phase of each Section of the 132KV Jack Bus Bar)
Laying & Re-Stringing of 132KV Jack Bus Bar by Twin ACSR Moose Conductors including Hoisting of Disc Insulator Tension String with associated Tension Fitting and Disc Insulator Suspension String with associated Suspension Fitting in 160MVA Transformers - I & II Bays at the Sub Station alongwith Shifting of the Conductors, Tension Fittings, Suspension Fittings, Spacers etc. from Stores at the Sub Station to Switchyard. (1 Job for each Phase of each Section of the 132KV Jack Bus Bar)
Fixing of 250 mm Spacing Spacers between Twin ACSR Moose Conductors of above newly Laid 132KV Jack Bus Bar.
Jumpering with Twin ACSR Moose Conductors between newly Laid 132KV Jack Bus Bars of Twin ACSR Moose Conductors to 132KV Bushing of 160MVA Transformer, 132KV Jack Bus Bar to LAs, CTs, T.I., 132KV T.I. to L.I.; 132KV L.I. to C.B., 132KV C.B. to B.I., 132KV B.I. to 132KV Main Bus, 132KV T.I. to 132KV Transfer Bus in 160MVA Transformers - I & II Bays at the Sub Station alongwith Shifting of the Conductors, P.G. Clamps, Equipments Terminal Connectors etc. from Stores at the Sub Station to Switchyard. (1 Job for each Jumper)
M/s S.S. Refregeration
LASHANI ENTERPRISES
Meena Elect and Engg Works
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid