Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | First₹13.4 LAccepted-AOC | First | Accepted-AOC lowest rate | |
| 2 | Second₹13.6 LRejected-AOC | Second | Rejected-AOC second lowest |
Tender Value
Refer Docs
EMD Value
₹22,500
Closing Date
22 Feb 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer
ASSISTANT ENGINEER LSGD VELLAMUNDA KATTAYADU PO VELLAMUNDA
PUBLIC WELL COSTRUCTION
2021_LSGD_414681_1
AE/T/10/2020-21/LSGD/ 446 PUBLIC WELL CONSTRUCTION
Open Tender
Civil Works - Water Works
Item Rate
90 days
LSGD Vellamunda
PUBLIC WELL COSTRUCTION
6 documents required · 6 mandatory
₹2,975
Yes
₹22,500
Yes
5 Jul 2021
15 Feb 2021
25 Feb 2021
15 Feb 2021
22 Feb 2021
15 Feb 2021
14 days
Amount
MundackalColony, KocharaColony, Chengilerykunnu
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
od1074966/2020_2021 : Sinking well in all classes of soil except hard rock which requires blasting to line and levels and plumb by scooping out from inside and below the stiening complete . (Upto 3.50M dia). First depth up to 3.0 mtr. from GL<br>All kinds of soil
od1074967/2020_2021 : Sinking well in all classes of soil except hard rock which requires blasting to line and levels and plumb by scooping out from inside and below the stiening complete . (Upto 3.50M dia). Second depth up to 1.50 mtr. from GL<br>All kinds of soil
od1074968/2020_2021 : Sinking well in all classes of soil except hard rock which requires blasting to line and levels and plumb by scooping out from inside and below the stiening complete . (Upto 3.50M dia). Third depth up to 1.50 mtr. from GL<br>All kinds of soil
od1074969/2020_2021 : Sinking well in all classes of soil except hard rock which requires blasting to line and levels and plumb by scooping out from inside and below the stiening complete . (Upto 3.50M dia). Fourth depth up to 1.50 mtr. from GL<br>All kinds of soil
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
5.7 : Reinforced cement concrete work in well - steining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
5.9.12 : Centering and shuttering including strutting, etc. and removal of form for:Well steining
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
od1080771/2020_2021 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.350 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(Rate of sheet Reduced in proportion of thickness of sheet)
60.2.2 : Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete
od1074970/2020_2021 : Supplying and spreading graded metal 20mm and 10mm 1:1 ratio as afiltering medium at around the well<br>
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
18.57.2 : Providing and fixing PTMT, push cock of approved quality and colour.15 mm nominal bore, 80 mm long weighing not less than 46 gms
50.18.9.2.2 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia 10 Kgf/cm2
50.18.9.4.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2
50.18.9.5.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2
50.18.9.6.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2
50.18.9.8.2 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2
od1076682/2020_2021 : Supplying and fixing 1.5HP bore well type submersible pump set Kirloskar or equalant make with all fitting, pump house wiring etc...
od1076683/2020_2021 : Supplying and fixing 5.0HP bore well type submersible pump set Kirloskar or equalant make with all fitting, pump house wiring etc...
PWD Contractor
Bidder Name
PWD Contractor
Stephen.P.M
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_588950.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .