| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC 21 B ARJUN NAGAR AMBALA CANTT | ₹1.7 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹1.7 L+₹1,062.77 (0.64%)Rejected-AOC 139 GOBIND NAGAR AMBALA CANTT | ₹1.7 L+₹1,062.77 (0.64%) | L2 | Rejected-AOC 2nd |
Tender Value
₹1.7 L
EMD Value
₹3,380
Closing Date
21 Mar 2026, 3:00 pmClosed
Kailash Chander Kala ravi kumar and virender singh
DIV Ambala
AMtc of EPHS in Sector 34 UE Ambala Cantt Repair of water supply and leakage providing and fixing of special complete in all respect
2026_HBC_508577_1
2026BCBA2D77 61B7 4F2D 987C F0BA236311BE239HSV
Open Tender
Civil Works
Works
30 days
Ambala City
2 documents required · 2 mandatory
₹250
₹3,380
Yes
17 Apr 2026
16 Mar 2026
23 Mar 2026
16 Mar 2026
21 Mar 2026
16 Mar 2026
[1.PM057] PM057. Hire charges for JCB with bucket capacity more than 0.75 cum with fuel and driver
[13.31]Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
[20.10.2]Extra for fixing sluice valves/flap valves socketed or flanged including cartage from stores or nearest Railway Station to site of works 2. 100 mm i/d
[20.10.3]Extra for fixing sluice valves/flap valves socketed or flanged including cartage from stores or nearest Railway Station to site of works 3. 150 mm i/d
[20.15.1]Providing and fixing C.I. Kinetic air valves conforming to and marked with IS: 14845 including carriage, loading, unloading stacking, handling, re-handling etc., drilling, tapping, screwing in valves connections complete in all respects to the satisfaction of Engineer-in- Charge. 1. 80 mm i/d
[20.15.2]Providing and fixing C.I. Kinetic air valves conforming to and marked with IS: 14845 including carriage, loading, unloading stacking, handling, re-handling etc., drilling, tapping, screwing in valves connections complete in all respects to the satisfaction of Engineer-in- Charge. 2. 100 mm i/d
[20.49.1]Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. Size of the main with which connection is to be made. 1. Up to 200 mm internal diametre
[20.59.2]Providing and fixing Cast Iron Detachable Joints class-25 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 2. 100mm i/d CID Joint
[20.59.3]Providing and fixing Cast Iron Detachable Joints class-25 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 3. 150mm i/d CID Joint
[20.59.4]Providing and fixing Cast Iron Detachable Joints class-25 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 4. 200mm i/d CID Joint
[20.63.1]`Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade SandS pipes as per 15:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/W to be measured and paid separately. ` 1. 100 mm i/d
[20.63.2]`Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade SandS pipes as per 15:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/W to be measured and paid separately. ` 2. 150 mm i/d
[20.66.1]Cutting DI pipe and chipping or filling the surface to a uniform finish 1. 100 mm i/d
[20.66.2]Cutting DI pipe and chipping or filling the surface to a uniform finish 2. 150 mm i/d
[20.68.1]Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths Ductile Iron (DI) standard specials plain /flanged/ socketed confirming to IS9523-2000 with rubber ring (EPDM/SBR) joints such as tees, bends, tapers, caps etc. with in trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. 1. Up to 300mm dia
stage.html
html • 0.04 MB
technical_587349.pdf
techsummary_587349.pdf
finance_587349.pdf
BOQ Comparative Chart
xlsx
finsummary_587349.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
BOQ_587349.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .