| 1.00AC spec | ||||
| 1.00 | OD173017/2025-2026:Supply, installation testing and commissioning of wall mounting 3 star 1.5Tr Inverter
split air conditioner copper unit of the following ratings conforming to relevant IS
suitable for operating on 230V, 50Hz single phase AC supply, filled with R-410 A
/R32 refrigerant gas, high energy efficient, RoHS complaint, capable of performing
functions like ling,dehumidifying, air circulating, filtering etc of following capacity
including refrigerant copper piping 3m with sulation,control cable up to 5m, 3 m
drain pipe, condenser stand, microprocessor control with cordless remote control, etc. with comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc (O General/ Blue star/ Daikin/ Carrier/ Samsung or equivalent) | 2 | each | 43,448.33 ₹86,896.66 Lowest |
| 1.00 | OD173016/2025-2026:Supply installation testing and commissioning of 2 TR 3 star rated split Inverter type air- conditioner unit conforming to IS 1391(Part2/92) suitable for operation on 230V+/- 10% 50 Hz single phase AC supply fitted with hermeticaly sealed compressor operating on R22/ono CFC refrigent with ondensing and evapourating unit capable for cooling air circulation and filtering etc.including rerigent copper piping with insulation upto 5 Metre or required length microprocessor control with chordless remote control and comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. (O General/Blue star/Daikin/Carrier/ Samsung or equivalent) | 3 | each | 54,431.47 ₹1,63,294.41 Lowest |
| 1.00 | OD173018/2025-2026:Supply and fixing 4 KVA voltage stabilizer V guard or equivalent for split inverter type AC with input voltage 170 to 270 V and output voltage range of 210 to 230 V with overload protection (cutt off),Initial time delay, High and Low Voltage Cut Off, Micro-controlled operation, High temperature protection, indicators and chord wire etc.as required. | 2 | each | 3,543.36 ₹7,086.72 Lowest |
| 1.00 | OD173020/2025-2026:Supply and fixing 5 KVA voltage stabilizer V guard or equivalent for split inverter type AC with input voltage 170 to 270 V and output voltage range of 210 to 230 V with overload protection (cutt off),Initial time delay, High and Low Voltage Cut Off, Micro-controlled operation, High temperature protection, indicators and chord wire etc.as required. | 3 | each | 3,886.58 ₹11,659.74 Lowest |
| 1.00 | OD204128/2025-2026:Supply and providing frame for the outdoor unit for1TR/ 1.5TR / 2 TR high wall split
AC unit | 5 | each | 1,650.36 ₹8,251.8 Lowest |
| 1.01 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator | 5 | each | 558.86 ₹2,794.3 Lowest |
| 1.01 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) | 5 | each | 310.73 ₹1,553.65 Lowest |
| 1.01 | 90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface | 5 | each | 249.64 ₹1,248.2 Lowest |
| 1.01 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | 5 | each | 205.12 ₹1,025.6 Lowest |
Tender Value
₹3.2 L
EMD Value
₹7,888
Closing Date
20 Sept 2025, 6:55 pmClosed
ASSISTANT EXECUTIVE ENGINEER
Office of the Executive Engineer, LID and EW Division, Malappuram, civil station, Malappuram District Panchayath Building, Malappuram, 676505
Annual Plan-Malappuram District Panchayath Renovation of Nilambur District Hospital installation of Air Conditioners-S0421/25-General Electrical Work(Retender)
2025_LSGD_795931_5
DB1/TN/ELE/AEE/29/25-26
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
MALAPPURAM
Please refer Tender documents.
11 documents required · 11 mandatory
₹826
₹7,888
Yes
28 Nov 2025
12 Sept 2025
22 Sept 2025
12 Sept 2025
20 Sept 2025
12 Sept 2025
Amount
AC spec
OD173017/2025-2026:Supply, installation testing and commissioning of wall mounting 3 star 1.5Tr Inverter split air conditioner copper unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply, filled with R-410 A /R32 refrigerant gas, high energy efficient, RoHS complaint, capable of performing functions like ling,dehumidifying, air circulating, filtering etc of following capacity including refrigerant copper piping 3m with sulation,control cable up to 5m, 3 m drain pipe, condenser stand, microprocessor control with cordless remote control, etc. with comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc (O General/ Blue star/ Daikin/ Carrier/ Samsung or equivalent)
OD173016/2025-2026:Supply installation testing and commissioning of 2 TR 3 star rated split Inverter type air- conditioner unit conforming to IS 1391(Part2/92) suitable for operation on 230V+/- 10% 50 Hz single phase AC supply fitted with hermeticaly sealed compressor operating on R22/ono CFC refrigent with ondensing and evapourating unit capable for cooling air circulation and filtering etc.including rerigent copper piping with insulation upto 5 Metre or required length microprocessor control with chordless remote control and comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. (O General/Blue star/Daikin/Carrier/ Samsung or equivalent)
OD173018/2025-2026:Supply and fixing 4 KVA voltage stabilizer V guard or equivalent for split inverter type AC with input voltage 170 to 270 V and output voltage range of 210 to 230 V with overload protection (cutt off),Initial time delay, High and Low Voltage Cut Off, Micro-controlled operation, High temperature protection, indicators and chord wire etc.as required.
OD173020/2025-2026:Supply and fixing 5 KVA voltage stabilizer V guard or equivalent for split inverter type AC with input voltage 170 to 270 V and output voltage range of 210 to 230 V with overload protection (cutt off),Initial time delay, High and Low Voltage Cut Off, Micro-controlled operation, High temperature protection, indicators and chord wire etc.as required.
OD204128/2025-2026:Supply and providing frame for the outdoor unit for1TR/ 1.5TR / 2 TR high wall split AC unit
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
OD174902/2025-2026:Drain pipe for condensate drain to the nearest drain point with 32mm U PVC pipe insulated using 9mm thick Nitrile Rubber tubing as per Client/Engineers instruction.
OD174903/2025-2026:Supply and providing following size soft drawn Copper pipe for extending pipe between out door and indoor units including insulating pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc. 3/8"(9.52mm) and 5/8"(l5.8mm) 22 gauge
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Bidder Name
JINTO ANTONY
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1317282.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .