GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004
CERTAIN MINOR AND SANCTIONED WORKS UNDER GE NS KOCHI
2023_MES_575868_2
8214/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kochi, Alwaye
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹78,800
Yes
31 Mar 2023
4 Mar 2023
23 Mar 2023
4 Mar 2023
21 Mar 2023
4 Mar 2023
Amount
Material & Labour for concealed point wiring complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLS including PVC conduit ISI marked not less than 20mm dia with concealed sunk in pressed steel terminal modular boxes of required size of thickness 1.2 mm factory made and painted with stove enameled black paint with top cover including 1.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture for One 3 pin/5 pin socket outlet point 5 Amp on independent boardcomplete with all accessories complete all as specified and directed .
Material & Labour for sub main wiring with two runs of 4 Sqmm PVC insulated FRLS multi stranded copper conductor cable including suitable size PVC conduit with one run of 4 Sqmm PVC insulated FRLS cable as earth continuity wire complete all as specified and as directed. Note: Three runs of 4 Sqmm and one run of PVC conduit shall be measured as one length.
Supply and fix switch Socket combination modular, 6A - 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix wall mounted fan with accessories 230V, 450 mm sweep size, Sturdy & heavy duty aluminium blades for high air delivery, Nickel chrome plated guard, Smooth oscillation, 1400 RPM including mounting arrangements complete all as specified and directed.
Supply and fix MCB distribution board SPN 8 way, with 200 Amps rated bus bar having IP 44 protection suitable for SPN MCB as incomer and 6 Nos SP MCB as outgoing, double door complete all as specified & directed. Note: MCBs will be measured and paid separately.
Supply & Fix MCB 20 Amps, 240 Volts, breaking capacity 10 KA, SPN 'C' series complete all as specified and directed.
Supply & Fix MCB 5 to 32 Amps, 240 Volts, breaking capacity 10 KA, Single pole 'C' series complete all as specified and directed.
Material & Labuor for Earthing with GI wire 4mm dia with galvanised MS earth plate of size 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below ground level, earth plate shall be packed on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected to GI earth wire 4mm dia (8 SWG) protected by GI pipe 15mm bore (light grade) and watering pipe 20 mm dia (light grade) of suitable length, with necessary earth work including disposal of surplus soil to a distance not less than 50 metre, PCC pit chamber with RCC cover frame, funnel, wire mesh. The GI earth wire 8 SWG under the earth and on the pole up to a height of 1.5 metre shall also be protected by 15mm dia GI pipe (light grade) & GI pipe to be fixed with poles by the means of 2 Nos flat iron clamp 25 x 3 mm size complete with bolts, nuts and washers etc. all as specified and shown in electrical plate No 3 of SSR Part I - 2009 complete all as specified and directed. Note: - Main earthing lead from earth plate to test point & up to 7.5 Metre to be provided. The cost for the same shall be deemed to be included in the above quoted rate.
Material & Labour for Earthing with copper earth plate of size 600 x 600 x 3.15 mm thick buried directly in ground not less than 2.25 metre below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by copper strip of size 20 x 3 mm thick, soldered and riveted to earth plate, Copper earth strip will be protected by using 40mm bore GI pipe (light grade) earth plate to transformer body, LT feeder pillar box, and neutral of transformer etc complete. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20 mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metre etc complete all as specified and shown in electrical plate No 3 of SSR Part I – 2009 complete all as specified and directed. Note: - Main earthing lead from earth plate to test point up to 7.5 Metre shall be provided. The cost for the same shall be deemed to be included in the above quoted rate.
Supply & Fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required Copper earth strip 20x3 mm with saddles/fasteners/insulators and fixing screws etc. all as specified and directed by Engineer in charge.
Material & Labour in replacement of test terminal block made of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws complete as directed
Material & Labour 40mm bore galvanised steel tubing, Light grade, fixed on the top of the roof with socket/clamps or by welding etc. for fixing single point air termination rod for lightening conductor support as required at site including removing of the old rusted pipe complete all as specified and directed.
Supply & Fix air termination single pointed copper rod 12mm dia 300mm long for lightning protection complete as specified.
Supply & Fix single phase surge protection device type 1 & 2 tested for lighting impulse current 10/350 micro second 50 ka for phase to neutral and 125 ka for neutral to earth, surge protection device tested for nominal discharge current 8/20 micro second 20 ka phase to neutral voltage protection level, <=1.4kv, encapsulated spark technology for line to neutral for type 1 and metal oxide for arrestor for type 2 line to neutral. LED indication in line to neutral pole in type 1 and flag indication in type 2 line to neutral, response time for type 1 is less than 100 nano second and type 2 is less than 25 nano second, DIN Rail mounted complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light,fan,socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants regulators, sockets, light fittings etc removing materials from site and making good disturbed surface of walls,floors,ceiling etc complete all as specified and directed.
Material & Labour for One light point wiring concealed controlled by one switch with PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 Sqmm size drawn through and including stove enameled steel conduit of suitable size and all accessories, fire resistant, ISI Marked including 2 mm thick 60mm depth GI sheet pressed terminal box (recessed) with 3mm thick laminated hylam sheet top cover including PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 Sqmm as earth continuity conductor and making good the disturbed surfaces of walls/floors/ceiling etc all as specified and directed.
All as per item No 16 above but for one three pin socket outlet 15 Amps independent with cable 2.5 sqmm size complete all as specified directed
Supply & Fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified directed.
Supply & Fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed.
Supply & Fix CIMFR certified LED flameproof batten suitable for twin T8 tube of 20Watt including LED lamp 20Watt, recommended for gas/Vapor group of llA & IIB and Zone 1 & 2, IP65 Protected complete all as specified and directed.
Supply and Laying UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 70 sqmm with suitable cable gland complete all as specified and directed.
Ditto All as per Sl Item No 21, but aluminium conductor of size 4 core 6 Sqmm.
Material & Labour for GI tubing medium grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 40mm dia complete all as specified and directed.
Cutting existing road/hardstand of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 150 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Material &Labour for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Metres below ground level) with top edge of earth plate not less than 1.5 Metres below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering funnel with 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point or LT panel etc, and testing on completion, complete all as specified & directed by Engineer-in-Charge.
Supply and fix in repair junction box made of polycarbonate water proof of size 126x228x111mm with IP 67 protection including cable connector and MCB brackets with suitable size clamps fixing for pole/in PCC foundation complete all as specified and directed by Engineer-in-Charge.
Material & Labour for point wiring with 2.5 Sqmm PVC insulated unsheathed multistranded single core copper conductor cable in PVC conduit not less than 25mm including 2mm thick MS sheet pressed terminal box (recessed) with 3mm thick laminated hylam top cover including 2.5 Sqmm PVC insulated copper conductor earth continuity wire for controlled by one switch for 16 A socket outlet complete all specified and directed.
Supply & Fix in switch socket combination 5 pin 16 Amps multipurpose complete all as specified and directed.
Supply & Fix Sheet metal enclosure for DB TPN 6 way double door complete all as specified and directed.
Supply & Fix MCB TPN upto 63 Amps complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth for foundation of pole and laying of underground electric cable in soft/loose soil complete all specified and directed.
Supply and spread River Sand for cushioning and covering of UG cables in trenches complete all specified and directed. (Note : For measurement purpose only punned thickness shall be measured and paid)
Material and labour for common burnt clay building bricks sub-class 'B' designation of size 230X115X75mm complete all as specified and directed
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm complete all specified and directed.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all specified and directed.
Supply and Laying UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 120 sqmm with suitable cable gland including taking down of unserviceable cable complete all as specified and directed.
Ditto All as per Sl Item No 37, but aluminium conductor of size 3.5 core 95 Sqmm.
Ditto All as per Sl Item No 37, but aluminium conductor of size 3.5 core 50 Sqmm.
Ditto All as per Sl Item No 37, but aluminium conductor of size 3.5 core 25 Sqmm.
Ditto All as per Sl Item No 37, but aluminium conductor of size 2 core 10 Sqmm.
Material & Labour for straight through joint 3.5 core 95 to 120 Sqmm with all accessories complete all specified and directed.
Material & Labour for straight through joint 3.5 core 25 to 50 Sqmm with all accessories complete all specified and directed.
Supply and laying un-reinforced precast concrete cable cover class LV type-I flat size 250mm x 150mm x 40mm complete all specified and directed.
Supply, installation, testing and commissioning of water cooler with inbuilt purifier ozone based technology cooler stainless steel body cold, hot and normal water output most superior water purification technology ozonisation, based on microprocessor, controlled electronic system industrial model with dispenser to ensure the precise operation 90 Litre/ Hour dispensing capacity and steel storage tank and connecting up including taking down the existing unserviceable cooler from existing location transporting and depositing to MES store yard complete all as specified and directed.
Supply and Fix Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230 with accuracy + 2.5% and of capacity 4 KVA complete all as specified and directed.
Supply & Fixing of Single pole enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amp, 240 volts 10 KA, C curve and plug to with male ended portion complete all as specified and directed.
Supply & Fix 20mm outer dia CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with all necessary fittings & fixtures complete all as specified and directed.
Supply and Fix 32 mm PVC heavy duty flexible hose complete all as specified and directed.
Supply & Fix MCB SPN 6-32 Amp, C curve, 240 Volt, 10 KA complete all as specified and directed.
Dismantling and taking down split ACs with and including dismantling of three core copper cable, connecting MCB boxes, copper piping etc, complete making good disturbed surfaces as matching to the existing surfaces complete all as specified and directed
Supply, installation, testing and commissioning of split air conditioning unit 1.5 TR capacity (Inverter type) with HD filter, complete with cordless remote control, minimum 5 star labeled, latest energy efficient model, eco friendly refrigerant gas, 4500 Kcal / Hr, 50 Hz, 240 volts, air cooled copper condenser with all accessories varied speed including fixing the outdoor unit with suitable stand as per site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant with nitrile rubber insulation and control cable from indoor to outdoor up to 3 metre as provided by OEM, Power cabling (Maximum 3 metre from Isolator/ Enclosure) to unit, first charging of refrigerant gas, including cordless remote, drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified.
Supply, installation, testing and commissioning of split air conditioning unit 2 TR capacity (Inverter type) with HD filter, complete with cordless remote control, minimum 3 star labeled, latest energy efficient model, eco friendly refrigerant gas, 6000 Kcal / Hr, 50 Hz, 240 volts, air cooled copper condenser with all accessories varied speed including fixing the outdoor unit with suitable stand as per site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant with nitrile rubber insulation and control cable from indoor to outdoor up to 3 metre as provided by OEM, Power cabling (Maximum 3 metre from Isolator/ Enclosure) to unit, first charging of refrigerant gas, including cordless remote, drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified.
Supply and fixing copper refrigerant piping of both sizes for suction line 5/8" and 1/4" for discharge including thermal insulation class "O" nitrile rubber insulation density 45- 55 kg/m³, for suction/ discharge line, beyond standard length provided with original units by the manufacturer. Note: 1) This item shall be measured for the quantity used at site for item No. 53 & 54 for beyond the length provided by OEM, along with unit. 2) One run of both 5/8" & 1/4" pipes along with insulation shall be measured as one length.
Supply & Fix Decorative LED Post Top Lantern 25 watt, 3000K made in die-cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser and IP 65 protection opal diffuser, complete all as specified and directed. Make shall be as per Cat ref No BGCTN 25W LED WW of Bajaj or Equivalent in Crompton/Philips/Luker.
Supply & Fix Decorative Bollard LED Light having IP-66 protection, 1.0 metre long, die cast housing, opal acrylic diffuser inbuilt LED complete with base plate and GI foundation bolts and nuts including earth work and PCC foundation, compete all as specified and directed by Engineer-in-Charge, Make shall be as per Cat ref No BGBOM 1000 15W LED WW of Bajaj or Equivalent in Crompton/Philips/Luker.
Supply & Fix LED Post Top in Spherical shape polycarbonate opal and clear diffuser with IP 65/66 protection including 3 mere GI pole light grade 40mm bore including earth work and PCC foundation, compete all as specified and directed by Engineer-in-Charge. Make shall be as per Cat ref No BLPTSP 25W LED NW of Bajaj or Equivalent in Crompton/Philips/Luker.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
AMRITH ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .