Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER, HENCE ACCEPTED | |
| 2 | L2₹47.3 L+₹1.4 L (3.04%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 3 | L3₹48.1 L+₹2.2 L (4.87%)Rejected-Finance 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L3 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 4 | L4₹49.1 L+₹3.2 L (6.92%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED | |
| 5 | L5₹49.4 L+₹3.5 L (7.54%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER, HENCE REJECTED |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
6 Jan 2025, 6:00 pmClosed
GARRISON ENGINEER
DADWARA KOTA RAJASTHAN 324002
SPL REPAIR TO STREET LIGHT IN SOUTHERN SECTOR FROM HADOTI GATE TO ARJUN GATE AND CERTAIN REVENUE WORK AT MIL STN KOTA
2024_MES_688398_1
8899E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
MIL STN KOTA
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
Yes
GE Kota
₹94,000
Yes
10 Feb 2025
12 Dec 2024
13 Jan 2025
12 Dec 2024
6 Jan 2025
31 Dec 2024
Amount
M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine including insertion of HDPE pipe upto 90 mm dia for protection of LT cable and including taking necessary permission from Railway/ MSEDCL/ any other department complete all as specified and as directed. Note : HDPE pipe shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Dismantling concrete poles/ struts, any size, transporting to store and stacking or for schedule of credit complete all as specified and as directed.
Supply and installation of Decorative pole (CI+MS) (8 mtr long) including Single arm bracket, Pole must have lower section OD 114mm and top section 76mm diametre made out of GI pipe as per IS 1239 having two ornamental decorative staining golden colour made of pressure die casting in aluminium at bottom and middle. The pole shall have window cutting of 300mm x 80mm weather proof flush door & locking arrangement for housing of the pole to accomodate electrical accessories (Bakelite plate and connector) for power supply connection.The window cover is fitted with allen screws to the pole and is to be provided in bottom section of pole. The body of pole shall be machined and polished properly to give it a smooth surface as per IS 2629 and IS 2633. The decorative pole shall be duly pre-treated and painted UV resistant coating in grey colour shade. The pole and the cast iron embellishments should be machined & polished properly to get thesmooth finish.The coating should have a DFT of 80-90 microns.Entire unit shall be given an extensive three stage treatment with PU based primer,Zinc phosphate primer and poly urethane paint of approved colour & prescribed for such surfaces to make it absolutely rust and corrosion proof as well as giving it a pleasing appearance.Base plate outside PCC of size 250mmx250mm with 12 mm thickness having 4 holes of 20mm dia at a distance of 200mm complete with CI base plate inside PCC complete all as specified and as directed. Decorative Arms must have Sturdy design made of 76mm dia GI pipe for pole mounting and 48mm dia GI pile for product installation. Golden knob is provided at the top to enhance the aesthetics of the product. Brackets can be mounted on poles with top dia less than70mm. Bracket must be Hot dip galvanised with minimum average GI coating of 35μm. PU(Polyurethane) Painted with avg. thickness of 80μm in Grey colour (RAL-7024). Single and double arm brackets can be installed on the pole (dia <70mm) using M8 X 15 hex bolt provided with the product. Manufactures should have NABL approved lab. Manufacturer should have both product Pole along with Arm and Street Lights for better aesthetics. Note: Cost of studs, nuts & bolts and connected accessory shall be included in the ratye quoted. PCC shall be measured & paid separately.
Supply and fixing of decorative 90W Street Light, designed with a classic look using new generation technology in LED to enliven your outdoor areas in perfect synchronization with functionality and aesthetics, family of post-top lanterns designed to complement the geometry of the area with heritage touch. Light should have UV protected pure polyester powder coated grey after phosphochromate treatment, polycarbonate cover Injection melded, clear polycarbonate cover with IK09 impact resistance rating. Light must have secondary optics for better light distribution. Product should not more than 90W and Light Output should not less than 11500 lumens with operating temperature of 50 degree and Voltage range 140V to 270V. Average life of product should be 50000 hr, driver Built-in potted electronic LED driver with APFC, (SMPS based constant current supply), lower THD, Open Circuit Protection, over Voltage protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13 complete all as specified and directed.
S & F three core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed.
Supply and fixing connector with aluminium bus bar suitable for 3 phase & Neutral , 4 wire of capacity 32 Amps and MCB 0.5 to 1 amps SPN incl necessary fixing arrangements in pole complete all as specified and directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Supply only high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63 and nominal diameter 63 mm including all fittings and fixtures for insertion into horizontal boring complete all as specified and directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed.
S & F LED flood lights nominal power 120 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700⁰K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LF20-132-060-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F LED bollard lights nominal power 10 watt, pressure die-cast aluminium alloy housing with polyester powder coated, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 800, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 2 kVs, protection grade IP 65, CRI greater than 70, CW available CCT of 5700⁰K, power factor of minimum 0.95, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. Make :- Cat Part No LBLSN-10-CDL of Crompton or LBLDCON010XW of JAQUAR or TURINBLS10WLED857PSYMTOPC of Havells OR techno commercially equivalent makes specified in PS.
Supply and fix PVC/Polycarbonate made junction box of size 200 x 160 x 98 mm having two incoming and one outgoing cable ways along with fixing arrangement complete including 01 No MCB of C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 for streetlight complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Supplying & laying in trenches 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M/S R.K. Builders & Developer (BID ID -3206908)
Pioneer Enterprises (BID ID -3207200)
SINGH ENTERPRISES (BID ID -3207177)
Ganesh Contruction (BID ID -3206936)
ANNAPURNA ENTERPRISES (BID ID -3207555)
TARKESHWAR DASS CONSTRUCTION COMPANY (BID ID -3207520)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .