Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC 189 TEACHEARS COLONY THAKUR PLOT TAJBAG NAGPUR 440024 | NAGPUR | MAHARASHTRA | 440024 | ₹29.4 L | L1 | Accepted-AOC Work Completed |
| 2 | L2₹32.3 L+₹2.9 L (9.94%)Rejected-Finance | ₹32.3 L+₹2.9 L (9.94%) | L2 | Rejected-Finance Not found L1 |
| 3 | L3₹32.6 L+₹3.2 L (10.8%)Rejected-Finance | ₹32.6 L+₹3.2 L (10.8%) | L3 | Rejected-Finance Not found L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Agency has not submitted requisite documents as per NIT criteria. Hence Not eligible for opening of Envelope II ie Price Bid |
| 5 | Rejected-Technical G 4 106 107 1ST FLOOR SECTOR 11 ROHINI NEW DELHI 110085 | NORTH WEST | DELHI | 110085 | - | - | Rejected-Technical Agency has not submitted requisite documents as per NIT criteria. Hence Not eligible for opening of Envelope II ie Price Bid |
| Sl No | Description | Qty | Unit | M K ENTERPRISES L1 | Prakash Refrigeration L3 | VL SERVICES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, testing & Commissioning of 1 Ton Inverter Split Air Conditioner, which meets the all particular of 5 star rated, power supply 230V,50 HZ single phase operated,lesser running current, minimum noise level, 88 segment(white) panel display, flap LCD remote control ,auto air swing(up & down),auto air swing(left right), speed setting, auto restarts,sleep mode,on timer, off timer. Including connection of refrigerant piping, copper cabling, insulation around refrigerant pipe, providing drain line and allied works upto 3 meter or as provided by OEM, including powder coated stand, as per standard Engineering practice, complete etc. as required. | 90 | Job | 28,800 ₹25,92,000 Lowest | 29,500 ₹26,55,000 | 31,500 ₹28,35,000 |
| 2.00 | SITC of Voltage Stablizer, 230V, 50hz, suitable for single phase AC operation, having, Intelligent Time Delay System (for the compressor proper balancing time during frequent power failures). Low & High Voltage Cut-off Protection (to Protect connected equipment from potentially dangerous voltages) Latest IC Technology (to Assures reliable protection), Built In Thermal Overload Protection (to Protects the stabilizer and compressors during high temperature burnout) complete etc. as required. | 90 | Job | 1,800 ₹1,62,000 | 2,855 ₹2,56,950 | 1,250 ₹1,12,500 Lowest |
| 3.00 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in, cement mortar 1:6 (1 cement : 6 coarse sand) | 10 | Cum | 5,000 ₹50,000 | 3,250 ₹32,500 Lowest | 6,500 ₹65,000 |
| 4.00 | Cement plaster in fine sand : 12mm cement plaster of mix 1:6 1:6 (1 cement : 6 fine sand) | 5 | Sqm | 5,000 ₹25,000 | 490 ₹2,450 Lowest | 1,250 ₹6,250 |
| 5.00 | Dismantling steel work in built up area sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc, including dismembering and stacking within 50 meters lead. (For dismatling 69 nos. of air-washer units on roof top) @200kg per unit | 13,800 | Kg | 6 ₹82,800 Lowest | 21 ₹2,89,800 | 12 ₹1,65,600 |
| 6.00 | Hiring of crane to stack the dismantled material in item no. 5 from roof top up to the designated place within premises. | 2 | Days | 15,000 ₹30,000 | 12,000 ₹24,000 Lowest | 25,000 ₹50,000 |
Tender Value
₹35.7 L
EMD Value
₹71,311
Closing Date
14 Jan 2025, 6:00 pmClosed
AGM(E-E)
O/o. Airport Director, ATS Building, 1st Floor, AAI, Birsi Airport, Gondia-441601, Maharashtra.
Supply, installation, testing and commissioning of 1 Ton Split ACs for NIATAM Hostels at AAI Gondia.
2024_AAI_220316_1
AAI/GONDIA/NIATAMAC/CW02
Open Tender
Electrical Works
Works
45 days
AAI
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,180
Yes
₹71,311
Yes
3 Sept 2026
23 Dec 2024
16 Jan 2025
24 Dec 2024
14 Jan 2025
24 Dec 2024
24 Dec 2024 - 3 Jan 2025
Amount
Supply, Installation, testing & Commissioning of 1 Ton Inverter Split Air Conditioner, which meets the all particular of 5 star rated, power supply 230V,50 HZ single phase operated,lesser running current, minimum noise level, 88 segment(white) panel display, flap LCD remote control ,auto air swing(up & down),auto air swing(left right), speed setting, auto restarts,sleep mode,on timer, off timer. Including connection of refrigerant piping, copper cabling, insulation around refrigerant pipe, providing drain line and allied works upto 3 meter or as provided by OEM, including powder coated stand, as per standard Engineering practice, complete etc. as required.
SITC of Voltage Stablizer, 230V, 50hz, suitable for single phase AC operation, having, Intelligent Time Delay System (for the compressor proper balancing time during frequent power failures). Low & High Voltage Cut-off Protection (to Protect connected equipment from potentially dangerous voltages) Latest IC Technology (to Assures reliable protection), Built In Thermal Overload Protection (to Protects the stabilizer and compressors during high temperature burnout) complete etc. as required.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in, cement mortar 1:6 (1 cement : 6 coarse sand)
Cement plaster in fine sand : 12mm cement plaster of mix 1:6 1:6 (1 cement : 6 fine sand)
Dismantling steel work in built up area sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc, including dismembering and stacking within 50 meters lead. (For dismatling 69 nos. of air-washer units on roof top) @200kg per unit
Hiring of crane to stack the dismantled material in item no. 5 from roof top up to the designated place within premises.
VL SERVICES (BID ID -795461)
Prakash Refrigeration (BID ID -808592)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .