Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | ₹28.6 L Quoted ₹30.0 L | L1 | Accepted-AOC lowest quoted bidder. |
| 2 | L2₹31.9 L+₹1.9 L (6.25%)Rejected-Finance SRIPUR BICHWA VILLAGE MAJRA FARM KHATIMA UDHAM SINGH NAGAR UTTARAKHAND 262308 | KHATIMA | UDHAM SINGH NAGAR | UTTARAKHAND | 262308 | ₹31.9 L+₹1.9 L (6.25%) | L2 | Rejected-Finance Higher quoted bidder. |
| 3 | L3₹32.3 L+₹2.3 L (7.79%)Rejected-Finance 22 JANKALYAN SOCIETY NAVJIVAN AJWA ROAD BARODA 390 019 | BARODA | VADODARA | GUJARAT | 390019 | ₹32.3 L+₹2.3 L (7.79%) | L3 | Rejected-Finance Higher quoted bidder. |
| 4 | L4₹32.9 L+₹2.9 L (9.63%)Rejected-Finance SAI VILLA C 65 EKTA NAGAR BAREILLY UTTAR PRADESH 243 122 | BAREILLY | UTTAR PRADESH | 243122 | ₹32.9 L+₹2.9 L (9.63%) | L4 | Rejected-Finance Higher quoted bidder. |
| 5 | L5₹34.5 L+₹4.5 L (14.9%)Rejected-Finance | ₹34.5 L+₹4.5 L (14.9%) | L5 | Rejected-Finance Higher quoted bidder. |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
9 Jun 2022, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
SPECIAL REPAIR TO CERTAIN OTM BLDGS AND REPAIR / REPLACEMENT OF LT PANNEL SLUICE VALVE CHAMBER WATER LEVEL INDICATOR AVIATION LIGHT EARTHING AND CONNECTED WORKS OF MILITARY STATION BANBASA UNDER GE PITHORAGARH
2022_MES_517859_2
8449/BAN/E8
Open Tender
Miscellaneous Works
Item Rate
240 days
GE (MES) Pithoragarh
Class D, Category a(i)
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹80,000
Yes
3 Aug 2022
19 May 2022
11 Jun 2022
19 May 2022
9 Jun 2022
26 May 2022
Amount
DESCRIPTION OF ITEMS
Dismantling of plain or corrugated steel sheeting any gauge/thickness in roof covering ridge etc, complete all as specified and directed.
S & F Pre-painted Trapezoidal profile galvalume aluminium zinc coating steel sheet 0.50mm thick (base metal thickness) of any colour having tensile strength of 550 Mpa minimum yield strength conforming to IS - 513 (1994) coated with hot dip alloy of 55% aluminium + 43.50%Zinc +1.50% silicon and finished with resin coat ( of thickness not less than 35 micron) on both surface @150gm/sqm of coating (total both surfaces) of approved colour as in roof covering/cladding, fixed with self tapping screws (make hilty/fissers), neoprene and epdm washers class 3 of AS-3566(5.5-14X5 for crest and 5.5-14X25 for valley fixed) with 150mm end lap and one corrogation side lap whereever required penetrations and lap in sheet shall be sealed by using proper sealant profile/HDPE fillers shall be provided whereever required to close voids between sheets and fastners etc. as in roof covering/ cladding in straight or curved surface in any height complete all as specified and directed. Note : The colour of sheet for bldg shall be approved by GE.
S & F of pre-painted galvalume aluminium zinc coating GI base plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridge of roof covering / cladding to wall, fixed with self tapping screws/L-type or J-type or cranked hook bolts complete all as specified and directed.
Dismantling of timber scantlings 40 Sqcm or over in section in any position and in any situation complete all as specified & directed.
S & F of second class hard wood timber scantling clean sawn framed and fixed in any position and direction complete all as specified and directed.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates conforming to Gde Fe-410 W complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
S & F of suspended false ceiling system of grid/section size 600x600mm comprising of GI powder coated main 39x24x0.8mm thick (thickness comprising of GI/0.40+PPGS/0.3), cross TEE 29X24X0.8mm thick and wall angle 22.2x22.2x0.65mm thick duly suspend with 6 mm dia GI wire hangers fixed with steel dash fasteners or from purlin of the roof with clip including 4mm thick E- Board tiles for insulation and acoustic purpose of size 600x600mm to be placed in the grid system complete all as speceified and directed.
Demolition of brick work /stone work built in cement mortar complete all as specified and as directed.
M & L for brick work built in CM 1:6 with sub class old size bricks straight or curved on plan exceeding 6 m mean radius all as specified and directed.
Roughening surface of old concrete floor by picking, sweeping, clean and washing down with water to remove dust etc all as specified and directed.
M & L for machine Cut Kota stone slab flooring 20-25mm thick over and including 15 mm thick screed bed in cement mortar 1:6 laid and bedded jointed cement slurry mixed with pigment to match to shade of the slab incuding grinding, mirror polishing complete all as specified and directed.
M & L machine Cut Kota stone slab 20-25mm thick as in dado, riser of steps, skirting, and including 10 mm thick rendering as backing coat of kota stone CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match to shade of the slab incuding cutting grinding mirror polishing complete all as specified and directed.
Demolition of cement concrete unreinforced in Ground floor & paving n.exc 15cm thickness and removal of debris from site complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
M & L for hard core of broken stone aggregate of guage not exc 63 mm deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M & L for sand cushioning under floors including watering as required complete all as specified and directed.
M & L for rubber moulded precast concrete colour interlocking paver block of 60 mm thickness of M-35 grade conforming to IS - 15658-2006 with grey cement and pigment complete all as specified and directed.
M & L for 75mm thick cement concrete type C1 (1:3:6) using 20mm graded aggregate as in path finished surface even and rough to receive topping layer all as specified and directed.
S & F rubber moulded coloured chequered cement concrete tiles 20 cm x 20 cm x 20 mm thick over and including 15mm thick screed in CM 1:6 set and jointed in neat cement slurry and pointed in grey cement slurry with pigment complete all as specified and directed.
M & L for cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in coping, benching, cills, seismic and other similar bands and the like including weathering slightly rounded or chamfered angles and throating including necessary form work as required complete all as specified & directed.
Taking down cement plaster of any description in any position incl raking out joints making for key, scrubbing down with water etc and removal of debris from site all as specified and directed.
M & L for rendering in CM 1:4 on walls 15mm thick on fair faces of brick work finished the surface even and smooth with out using extra cement complete all as specified and directed.
M & L for rendering 15mm thick on other than fair faces in CM 1:6 finished the surface even and and smooth with out using extra cement complte all as specified.
M & L for preparation of new wall surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M & L for preparation of new wall surfaces and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for complete removal of existing treatment on walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of new wood and wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down chowkats or frames with shutter(without taking off shutter from the frame) area not exc 1.5 sqm and making the surface of brick wall good plastering, around the opening complete all as specified and directed.
Taking down chowkats of any description without taking of shutter from the frame exceeding 1.5 sqm but not exc. 4.0 sqm each and making the surface of brick wall good plastering, around the opening complete all as specified and directed.
Taking down shutters of any description area not exceeding 1 sqm and removing from site all as specified and directed.
S & F for framed work as in doors or gates of angle or other section Fe-410 Gde 250-A with gusset plates, rails braces, etc. complete drilled for fixing of steel sheeting or other covering. Doors etc shall be prepared for hanging or sliding with and including either hooks or hinges or steel hanging door fittings complete all as specified and directed.
M & L II class hard wood plain solid straight chowkats and frame wrought, framed rebated on the solid put together with glue, pinned at joints and fixed in position complete all as specified and directed.
S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles conforming to Fe 410-O 0r Fe 310-O complete all as specified and directed.
M & L for Plain Cement Concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in bed blocks for hold fast, coping, benching and similar work etc complete all as specified and directed.
S & F of 35 mm thick factory made flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M & L for 30mm thick 2nd class hard wood glazed shutter divided into square with plain,chamfered or rounded mitered and rebated sash bar any numbers, fitted with cut and mitred beads for securing glass etc and fitted to chowkat all as specified and directed.
M & L for 35mm thick 2nd class hard wood factory made wire gauged shutter edged of frame plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified and fitted to chowkat complete all as specified and directed.
S & F mild steel Butt hinges of medium weight and fixed 100mm all as specified and directed
S & F 150mm long ISI marked mild steel pressed handle, oval type, stove enamelled black complete all as specified and directed.
S & F 200mm long ISI marked mild steel barrel tower bolts, stove enamelled black with bright bolts and fixed complete all as specified and directed.
S & F 300mm long ISI marked mild steel sliding door bolts, bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S & F 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified
S & F 100mm long ISI marked mild steel barrel tower bolts, stove enamelled black with bright bolts and fixed complete all as specified and directed.
S & F 125mm long ISI marked mild steel pressed handle, oval type, stove enamelled black complete all as specified and directed.
S & F mild steel Butt hinges of medium weight and fixed 75mm all as specified and directed
S & F small fitting such as brackets, lach and hinge block shaped door and window stops and like including necessory labaours articles not exc 200 cu cm of Ist Class hardwood each all as specified and directed.
S & F sheet glass of 3mm thick ordinary quality and glazing with oil putty in square n exc 0.5sqm in each pane complete all as specified and directed.
Hacking out old broken glass (any thickness size quality and description) for wooden frame fixed with wooden beads or from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
S & F of Stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and direceted.
S & F in repair of Stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and direceted.
S & F in repair harrison/curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site complete all as specified and directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of complete all as specified and as directed.
M & L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLSH multi stranded conductor cable in and including Concealed PVC conduit of size 20/25mm ISI marked inclusive of tees,bend,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :-
(a) One light point / fan point / exhaust fancontrolled by one, one way switch 5 Amps
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the independent board.
(e) One bell point controlled by one, bell switch 5 Amps.
Description all as per item No 60 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site.
S & F for switch bell push piano type, 5 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site.
S & F switch piano flush button single pole one way 15 Amps flush type complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin, 5 Amp and 15 Amp flush type universal complete all as specified and directed.
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S & F for stepped type electronic fan regulator flushType, 120 W complete all as specified and directed at site.
S & F for lamp holder , PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed.
S & F for Bell Ding dong type suitable for operation on 230 volt 50 HZ AC supply complete all as specified and directed.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc and one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit. Cutting and chasing and making good to distrubed surface shall be deemed to be inclusive in quoted unit rate.
S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB triple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Labour only for refixing the celing fan/ Exhaust fan obtained from item No 59 above with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including over hauling of the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing LED lights fitting 1x18/20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
Taking down existing old existing unserviceable LT UG/ service cable of any description and size complete all as specified and directed. Note: Earthwork shall be measured and paid seprately under respective items.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 4 core x 25 Sqmm including laying, testing and commissioning complete all as specified and directed.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 2 core x 16 Sqmm including laying, testing and commissioning complete all as specified and directed.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 2 core x 10 Sqmm including laying, testing and commissioning complete all as specified and directed.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 3.5 core x 70 Sqmm including laying, testing and commissioning complete all as specified and directed.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 4 core x 10 Sqmm including laying, testing and commissioning complete all as specified and directed
Material and Labour for replacement of earthing complete with galvanized steel earth plate electrode 600 X 600 X 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 2009 part – I connected to earthing test point including earth continuity conductor and loop earthing etc. as required 4 mm dia galvanized iron or steel wire including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thck in RCC 1:2:4 type B1 duly reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and GI protection pipe light grade 15 mm dia beyond 7.5 mtr from electrode to earth terminal point /main switch board and 20mm bore GI watering pipe medium grade etc complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m in depth for foundations of poles/stay/struts etc, trenches for laying of cables and the like not exc 10 Sqm on plan and getting out in soft/loose soil all as specified and directed.
Removing excavated material (soil) at a distance n.exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm all as specified and directed.
M & L for sand cushioning with dry and clean sand over and under the under ground cable in trenches , ducts for cable protection incliding levellling and consodilation complete all as specified and directed by EIC.
M&L for brick protection cover of UG cable by using old size sub class 'B''common burnt clay building bricks, laid dry and flat abutting each other with width equal to length of the brick and gap between adjacent brick n exc 10 mm complete all as specified and directed.
Taking down of existing LT Panel cubical type by opening Nut bolt and screw and removing from room for deposting in store or contractor as schedule of credit complete all as specified and directed.
Supply installation,testing and commissioning in replacement in door type cubicle LT Pannel board suitable for 3 phase 4 wire 415 V, 50Hz, factory fabricated having mordern fabrication process powder coated having thickness not less than 100 microns provided with suitable rubber gasket to make it dust/ vermin proof OUTER SHELL: The outer shell be made out of 2.00mm thick CRCA and MS angle section 50x50x6 mm frame, factory fabricated with front and back openable, double door system (back side only) lockable/ openable by keys , louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands The dimenssion of the shell should be adequated to accommodated inner shell described below giving minimum 75mm space all around and shall be fabricated in such a way that the complete inner shell along with its control gears /accessories could be taken outside without disturbing outer shell. The outer shell shall be mounted on a zinc metal-coated stand having Zinc coating not less than 100 microns. Provision of threateded earthing stud at bottom and lifting lungs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54. Contd../-
INNER SHELL: Inner shell shal be made out of 2.0 mm thick CRCA sheet duily compartmentalized for each control gear. Front and back openable single door system lockable/ openable by keys from both sides having louvers and air vent gasket for natural flow of air. Gasket shall be used to make the inner shell completlely vermin proof and to accomodate incommer/ outgoing MCCBs and TPN Alluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shirnkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of the TPN bus bar. The cubicle shall incomer MCCB as well as outgoings shall have aluminium TPN extension links of currrent carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link shall not be less than 300 mm long supported on suitable size 'F' class insulators. The degree of protection for inner shell be IP-42 & carry the following items. Contd.../-
S&F in repair post top lantern light for 1 x 18 Watt LED lamp complete with all accessories including lamp complete all as specified and directed.
M & L for 40mm dia bore galvanized iron tubing, light grade, ISI Marked, for protection of cable fixed to pole / wall or laid in floors/road crossing ducts with all necessary fittings like clamps, bolts, nuts and washers etc complete all as specified and directed.
Supply and fix in repair energy conservation LED Flood light luminaries of 100 W watts including necessary mounting clamps with nuts & bolts & connection with sutable size of cable all as specified and directed.
M&L for replacement of earthing with galvanized steel earth plate of size 600 x 600 x 6 mm thick burried directly into ground (earth pit) not less than 2.25 m deep below ground level, top edge of earth plate not less than 1.5m below ground level, connected to galvanized mild steel strip 32 x 6mm (7.5m long) by means of rivets at one end and the other end connected to equipments body and neutral panel board, including GI pipe light grade of 40mm nominal bore for protection of Earth strip and watering pipe medium grade of 20mm nominal bore fitted with 0.63 mm thick GI sheet funnel with wire mesh etc complete including charcoal and salt , necessary mild steel clamps, nuts, bolts etc, earth work and excavation in any type of soil, making good to floor with PCC (1:2:4) type B-1, earth pit and precast RCC cover 65mm thick duly reinforced with 6mm dia MS round bars @ 100mm C/C both ways with lifting handle of 10mm dia MS bar, earth test point & making good to floor, complete all as specified and directed.
S & F in replacement Air termination single pointed aluminium rod 12 mm dia and 300 mm long complete as directed by Engr -in-charge.
S & F in replacement Test point terminal block made of gun metal or phosphorus bronze size 75 x75x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw complete as directed by Engr -in-charge.
S& F Aluminium strip 25x 3.00 mm with saddles and fixing screws etc for roof conductor and down conductor above ground from earthing to the lighting conductor as directed by Engr-in-charge.
S & F in replacement twin LED aviation light , hard red colour dome 2x20watt, weather proof IP-65 yellow painted complete including connetion from DB to fitting as directed.
Supply and installaion with testing complete of digital water level indicator device operating on single phase supply , direct display in 150 mm size digit system in meter/centimeter of water level of overhead tank ensuring alarm while water fall or rise at predetermined limit . One minute auto off alarm. The entire unit mujst operate through a compact electronic circuit which must ensure reliable operation at 230 V +/- 5% with reliable in digit display & alarm at low & high level of over head tank . The circuit must be housed in MS /CRC sheet box with nylon moulded connection strips. The level system must resistance transducer which unaffected by corrosion and other contactes availble in water. The unit must be controlled by micro switch (should be sensor system) The whole unit must electrically controlled and the upper level and lower level indicator must be highly senstive Micro Swith. The required copper cableof 0.5 Sq mm , 3 core size for OH tank and dismantling of old unserviceable water level shall be deemed to be inclusive in quoted unit rate.
M & L for maintaining the existing Sluice valve chamber of size 1mtr x 1mtr x 1mtr by scrapping the broken plaster and broken brick wall of chamber and making good the whole chamber by replastering and making wall of chamber by using cement Mortar,Bricks including cleaning of unwanted broken things of plaster and brick pieces or as directed by Engr -in-charge.
M & L cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape and size as directed or indicated and inclusive of one prime coat, one under coat and one finishing coat of paint including dismantling of old unserviceable cross arms complete all as specified and directed.
M & L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in mass concrete or similar work complete all as specified & directed.
M & L for surface excavation n.exc 15 cm deep and taking out the root of vegetable growth including cutting of bushes and level the whole excavated surface complete all as specified & directed.
Pushkar Dutt Bhatt
aditya construction
NORTH INDIA PEST CONTROL
Shri Siddhi Vinayak Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .