Loading…
Loading…
Tender Value
₹16.9 L
EMD Value
₹17,000
Closing Date
30 Jun 2026, 6:00 pm5d left
Similar tender results from the same govt authority in the past 3 years.
Executive Engineer’s office, Valsad (R&B) Division,
Repairing & Renovation of Second & Third Floor of Gujarat Bhavan Juhu At Andheri Mumbai (Flooring, False Ceiling, Plaster, Toilet Repairing, Door Windows & Miscellaneous Work)
316870
10 Of 2026-27
Open
Civil - All
Valsad
8 documents required · 8 mandatory
₹900
Executive Engineer, Valsad (R&B)Division, Valsad
₹17,000
23 Jun 2026
23 Jun 2026
23 Jun 2026
30 Jun 2026
23 Jun 2026
Name of Work :-
Repairing & Renovation of Second & Third Floor of Gujarat Bhavan Juhu At Andheri Mumbai (Flooring, False
Ceiling, Plaster, Toilet Repairing, Door Windows & Miscellaneous Work)
Bill of Quantities
(A) Percentage Rate Tender (Up to INR 50 Cr. )
Memorandum showing items of work to be carried out
Ite Quantity Unit Estimated Total Amount
Ite Quantity Unit Estimated Total Amount
No. Item of work In figure estimated
Rs. Ps. quantities
1 Removing cement tiles,or marble or polished shahabad floor or dado 158.00 Sqmt 45.45
without bed concrete including stacking the materials as directed with all
leads, lifts etc. complete
2 Removing rich mix cement concrete including stacking the spoils as 3.00 Cumt 939.30
directed with all leads, lifts etc, complete.
3 Removing doors and windows with frames and stacking the materials as 15.00 Nos. 157.56
directed with all leads, lifts etc. complete.
4 Removing W.C.Pans, Wash Basin, Urinals including disconnecting the 10.00 Nos. 209.07
sanitary and water supply connections, removing and breaking flooring
and bed con-crete around pan removing the same carefully and stacking
the service able material as adn where directed including throwing the
unserviceable materiasls out side etc.carefully and throwing out the
refusal outside etc. complete.
5 Water proofing Treatment to new Toilet/bathroom by using Polymeric 23.00 Sqmt 1547.32
Cementitious Membrane as approved by Engineer incharge,followed by
112mm thick brick bat coba covered with 20mm mortar finish.If there are
cracks on the bare slab,open the crack in V Groove and fill it with ready to
use repair polymer modified mortar based on special cements, aldehyde
based polymers with thixo tropy modifying agents.If there are lots of
honey combs and identified bad patches of concrete the same should be
grouted as per the instructions of site incharge.(The grouting shall be paid
separately).Clean the entire surface thoroughly and over this prepared
surface,apply three coats of polymeric Cementitious water proofing
coating having an on-toxic, 2-(methoxy carbonyl)-1-propene-Butyl-2
propenoate(MPBP) based polymeric waterproofing solution as approved
by Engineer in charge.Provide and lay112mm average thicknes of brick
bat coba in cement mortar 1:5 over 12mm thick CM1:3 bedding with one
pouch of 330 grams of thoroughblend of special cements,aldehyde based
polymers, shrinkage compensating agents as approved by Engineer in
charge per 50 Kg bag of cement and finishing with 20mm thick cement
plaster in cement mortar 1:3 by mixing one 330 grams pouch of above
admixture per 50 Kg bag of cement, including all lead, lifts and laid to
proper slope to drain off water entirely preparing bell mouth including
watta,beveled or champhered portion at the junction of wall and work up
to a height of 300mm or as directed and including finishing the top layer
of waterproofing treatement with false marking of 30cm x 30cm or as
directed, curing and covering the whole treatment.MPBPPolymeric
Waterproofing Coating for Concrete and Masonry should have following
minimum properties:1) Elongation%(ASTMD412-2016):@100%2) Tensile
Strength N/mm2(ASTMD4122016):3.33)Specific Gravity:1.02±0.024)Total
Solids(ASTMD1644-2012):43.98 5) Hardness Shore A (ASTM D2240-2015):
6 Providing and laying vitrified stone effect finish tiles having size 590 to 23.00 Sqmt 1786.69
605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirming to IS.
15622-2006 (Group Bla) of approved make, shade and pattern for
flooring in required position laid on a bed of 1:4 cement mortar including
required position laid on a bed of 1:4 cement mortar including neat
cement float, filling joints, curing and cleaning etc. complete
7 Providing and laying vitrified stone effect finish tiles having size 590 to 97.00 Sqmt 1862.44
605 mm x 590 to 605 or 1200 mm of 8 to 10 mm thickness and
confirming to IS. 15622-2006 (Group Bla) of approved make, shade and
pattern for dado and skirting in required position fixed in 1:4 cement
mortar including required position laid on a bed of 1:4
cement mortarincluding neat cement float, filling joints, curign and
cleaning etc. complete.
8 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with 25.00 Rmt. 268.66
necessary fittings, remaking good the demolished portion etc. complete.
Including removing existing pipe line if necessary and conveying and
stacking the same in PWD chowky or as directed etc. complete
9 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with 25.00 Rmt. 378.75
necessary fittings, remaking good the demolished portion etc. complete.
Including removing existing pipe line if necessary and conveying and
stacking the same in PWD chowky or as directed etc. complete.
10 Providing and fixing on walls /ceiling/ floor 40 mm dia. uPVC pipe with 30.00 Rmt. 525.20
necessary fittings, remaking good the demolished portion etc. complete.
Including removing existing pipe line if necessary and conveying and
stacking the same in PWD chowky or as directed etc. complete.
11 Providing and fixing on walls/ ceiling/ floor 50 mm dia. uPVC pipe with 30.00 Rmt. 729.22
necessary fittings, remaking good the demolished portion etc. complete.
12 Providing and fixing H.D.P container one piece moulded water tank made 2000.00 Ltr. 11.11
out of low density polythyler and built corrugation including of delivery
up to destination hoisting and fixing of accessories such as inlet, outlet
overflow of all tanks capacity above 1000 to 20,000 litres
13 Providing and fixing 40 mm. dia Ball cock medium type with PVC float 2.00 Nos 1222.10
including sockets and necessary fittings and tested as per municipal
requirements etc. complete.
14 Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain 15.00 Rmt. 513.08
Upvc pipes or of equivalent make, manufacture as per EN 13476 or
equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc,
jointing with rubber lubricant including necessary excavation, trench
refilling with selective excavated materialetc. complete.
15 Providing laying (to level or slopes) and jointing reinforced concrete Light 20.00 Rmt. 648.42
duty non-pressure pipes I.S. class NP2 of the following internal diameter
with collars and butt ends prepared for collar joints including testing of
joints complete.(D) 300mm
16 Providing , laying and fixing ,jointing Eco- drain 110 mm SN 8 Nu- Drain 30.00 Rmt. 330.27
Upvc pipes or of equivalent make, manufacture as per EN 13476 or
equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc,
jointing with rubber lubricant including necessary excavation, trench
refilling with selective excavated material etc. complete
17 Providing and fixing 15 cm rigid PVC Nahani trap including 10.00 Nos 576.71
PVC grating ,bend,connectingpiece of UPVC pipe up to the outside
face of wall , making
the good damaged surface and testing etc. complete ( Prior approval of
sample and brand by Ex. Engr. is necessary before use)
18 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass 10.00 Nos. 677.71
including necessary socket union nut complete.
19 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass 5.00 Nos 677.71
including necessary socket union nut complete
20 Providing and fixing C.P. pillar cock long neck with aerator of 5.00 Nos 1641.25
approed make including necessary sockets/union nut etc. complete.
21 Providing and fixing white Opal series European type wall-hung, of size 2.00 Nos 23663.29
400 mm x 370 mm x 575mm with approved make flush valve including
soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend
inlet pipe all fittings, cutting & making good walls, floors etc as directed
by Engineer in charge.( Make shall conf orm to manufacturer's Green
product and shall got approved from the Engineer In Charge.)
22 Providing and fixing C.P.Flush cock with wall flange 25mm with plain knob 5.00 Nos 1568.53
jaquar make continental (Cat.No. FLR 6081)
23 Providing and fixing plastic seat and cover for wash down water closer 10.00 Nos 434.30
with C.P. brass hinges and rubber buffers. (B) Plastic seal and cover.
24 Providing and fixing Jet spray heavy duty with S.S. Braided hose 60 cm 10.00 Nos 423.19
long with wall hook and other accessories etc. completed
25 Providing and fixing oval type under counter wash hand basin of 16 inch x 5.00 Nos 8886.99
22 inch size and of special colour shade having telephonic black /
coloured granite of 180 mm thick stone black kadappa framework
including chromium plated coupling bottle - Trap using CERA company or
equivalent oval typa wash basin model no 3448 as per detailed drawing
or as directed by engg incharge etc complete. (Counter size 1.20 m x
26 Providing and fixing 450mm x 550mm size superior type Belgium mirror 5.00 Nos 869.61
with 16mm dia. nickel plated towel rod etc. complete.
27 Providing and fixing white glazed urinal with Pressmatic auto closing 1.00 Nos 10494.91
valve having flow rate up to 4.0 Litr/Minute of Jaquar/Cera/Hindware
/Perryware or equivalent make with P.V.C. waste pipe with fitting
arrangement etc.complete as directed by Engineer in charge.( Make shall
conform to manufacturer's Green product and shall got approved from
the Engineer In Charge.)
28 Providing and fixing machine cut mirror polished 18 mm to 20 mm thick 0.80 Sqmt 4059.19
telephone black granite / Amba White / Cat bary brown / RBI red / Ocean
Brown granite stone partition with full moulding the edges etc. complete
. Both side polish
29 Providing and laying (two level or slopes) and jointing with stiff mixture of 20.00 Rmt. 172.71
Cement Mortar in proportion 1:1, Salt glazed stone ware pipes of pipes
150mm laying lime concrete 1:5:10 (1-Lime putty :5-Fine samd : 10-
Graded Stone aggregates 40mm nominal size) bedding for stoneware
pipes of following internal diameters with necessary formwork and curing
complete.(B) 150mm dia
30 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in 1.00 Nos 1616.00
cement concrete 1:4:8 outside the building including cast iron grating in
the sink, connecting glazed stoneware pipe, brick masonry chamber with
cast iron lid and cast iron grating for the gully trap.
31 Providing and constructing Brick Masonry Inspection Chamber 60cm 2.00 Nos 9251.60
x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4
cement concrete channels half round G.S.W. pipes, Brick Masonry,
plastering from inside and with frame fixed in cement concrete with
R.C.C. Cover medium duty 140Kilogramwith frame etc complete.
32 Providing and constructing Brick Masonry Inspection Chamber 90cm x 2.00 Nos 10884.77
45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement
concrete channels half round G.S.W.pipes, Brick Masonry, plastering from
inside and with frame fixed in cement concrete with R.C.C. Cover medium
duty 140Kilogramwith frame etc complete.
33 Removing the existing cement plaster of any thickness without causing 552.50 Sqmt 52.52
dust nuisance and stacking the debris upto a distance of 50 metres or
spreading in the compound and cleaning the site etc. complete.
34 Providing internal cement plaster 20mm thick in Single coats in cement 185.00 Sqmt 385.82
mortar 1:4 without neeru finish, to concrete, brick surface, in all
positions including scaffolding and curing etc.complete.
35 Providing internal cement plaster 12mm thick in single coat in cement 164.50 Sqmt 280.78
mortar 1:4 without neeru finish to concrete or brick surfaces, in all
positions including scaffolding and curing etc. complete.
36 Providing sand faced plaster externally in cement mortar using approved 203.00 Sqmt 645.39
screened sand, in all positions including base coat of 15 mm thick in
cement mortar 1:4 using waterproofing compound at 1Kilogramper
cement bag curing the same for not less than 2 days and keeping the
surface of the base coat rough to receive the sand faced treatment
6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking
out grains and curing for fourteen days scaffolding etc.complete.
37 Providing and applying two coats of flat oil paint of approved colour to 223.00 Sqmt 85.85
the old structural steel work and iron work previously painted in
building including scaffolding, if necessary, cleaning and preparing the
surface (excluding primer coat) etc. complete.
38 Removing, Repairing and Refixing Old existing wooden door shutter 36.00 No 2064.44
including repairing the shutter/frame using Randha machine and
replacing old fixture and fastening with new SS 304 grade fixtures like
Hinges, 1 Stoppers, 1 Aldrop , 2 Handle & 1 lock etc. and as directed by
engineer in charge etc comp.
39 Removing, Repairing and Refixing existing Alluminium window frame with 58.00 No 580.75
glass of all size shutter/frame, replacing all old Mosquite Net fixtures with
new locks, screws etc. including repairing the shutter/frame with Rates
includes all labour charges for removing, repairing & refixing the window,
all materials, transport cost, taxes etc.and as directed by engineer in
charge etc complete.
40 Removing, Repairing and Refixing existing Alluminium fix ventilation 11.00 No 348.45
frame with glass of all size shutter/frame, replacing all old fixtures with
new locks, screws etc. including repairing the shutter/frame with Rates
includes all labour charges for removing, repairing & refixing the
Ventilation, all materials, transport cost, taxes etc.and as directed by
engineer in charge etc complete.
41 Providing antitermite treatment to the sides of flooring of the existing 474.00 Sqmt 26.26
building as per I.S. 6313 (Part-III) by punching holes 6mm dia. drilled at a
distance of 30cm. centre to centre and injecting one percent of
chlorodane emulsion concentrate at the rate of 50 ml per hole and
sealing by filling putty etc. complete covering 2 years guarantee on bond
42 Providing and fixing in position (as per 1868 / 1982) Aluminium 9.50 Sqmt 5017.68
sliding window of three tracks with rectangular pipe 95 x 38.10 x
mm at weight 0.637 Kilogram/One Running Metre. with window frame
bottom track section 92 x 31.75 x 1.30 mm at weight
Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x
1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should
be of bearing bottom 40 x 18 x 1.25 mm at weight
Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at
weight 0.469 Kilogram/Running metre. and handle and top section
x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per
detailed drawings and as directed by Engineerincharge with all
necessary Aluminium sections fixtures and fastenings such as roller
bearing in nylon casting and self locking catch fitted in vertical section of
shutter including 5 mm thick plain glass and aluminium mosquito net
shutter with stainless steel jail with all required screws and nuts etc,
complete. With powder coating without box
43 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding 1.60 Sqmt 4912.64
window of two tracks with rectangular pipe having overall dimension
?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre.
and window frame bottom track section 61.85 x 31.75 x 1.20 mm at
weight 0.695 Kilogram/One Running Metre. Top and side track section
61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre.
The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight
0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x
mm at weight 0.469 Kilogram/One Running Metre. And handle section
x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top
section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As
per detailed drawings and as directed by Engineer in charge with all
necessary Aluminium sections fixtures and fastenings such as roller
bearing in nylon casting and self locking catch fitted in vertical section of
shutter including 5 mm thick plain glass with all required screws and nuts
etc, complete. With powder coating without box
44 Providing and fixing in position powder coated aluminium louvered 3.00 Sqmt 3501.67
windows / ventilator of various sizes with powder coating as per
detailed drawing and specifications including aluminium frames 80 x
38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of
approved quality etc. complete.
45 Providing and fixing solid core flush door shutter in single leaf 32 mm 23.00 Sqmt 3109.79
thick decorative type of exterior grade as per detailed drawings approved
face veneers 3 mm thick on both faces or as directed, all necessary beads,
mouldings and lipping, wrought iron hold fasts, chromium plated fixtures
and fastenings, with brass mortise lock, chromium plated handles on
both sides, and finishing with French Polish etc. complete.
46 Providing sills of required material 20mm to 25mm thick, on a bed of 97.00 Sqmt 3924.86
cement mortar 1:4 including cement float, filling joints with neat cement
slurry, curing, moulding edges, polishing,cleaning complete. b) Black
47 Providing and fixing mild steel grill work for windows, ventilators etc. 20 11.00 Sqmt 2117.97
Kilogram/ One Square Metre as per drawing including fixtures, necessary
welding and painting with one coats of anticorrosive paint and two coats
of oil painting complete.
48 Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter 45.00 Rmt 574.69
and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992
including proper rainwater receiving recess with P.V.C. plug, bend,
necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall
using approved wooden cleats projecting 25mm to 40mm from face of
wall a fixing with clips of approved quality and One Number ,filing the
joint using rubber gasket with solvent cement and properly resting the
shoe of pipes on C.C. or masonry blocks, including necessary scaffolding
and maintenance for 3 yrs for any leakages or dislocations of pipes. All
the P.V.C. fittings and additional 2 piece socket clips shall be got
approved from engineer in charge etc. complete.
49 Pro. And fixing single layer water proof gypsum board 12.5 mm thick 186.50 Sqmt 686.90
sections using water proof board of size 1220 mm x 1830 mm x 8.0 mm
suspended by GI suspender channel of size 25 mm x 3 mm with
intermediate channel og size 18 mm x 40 mm x 0.8 mm at 1220 mm
center to center ceiling section of size 40 mm x 35 mm x 0.55 mm at
mm c/c and perimeter channel A of size 20 mm x 27 mm x 30 mm x
mm at edges & drops incl.paper tap sand sofit cleat, anchor fastener,
scoch bolt connecting cleat,joining compound top coat on ceiling
incl.making necy.opening for light fitting,diffuser etc. comp. as per detail
drawing as directed
In Words Sixteen Lakh Ninety Three Thousand One Hundred Fifty Eight Rupees And Zero Paisa Only.
I/We am /are willing to carry out the work at…………% above/below percent (should be written in figures and words) at the
estimated rates mentioned above amount of my/your tender works out as under.
*Estimated Amount *Estimated Amount
put to Tender Rs. 1693158.00 put to Tender Rs.
Deduction …………….. % below………………… Add ………… % above Rs. …………….
1 The Credit Value of Dismentalled Materials of Amount Rs.16706.00 (In Words Sixteen Thousand Seven Hundred Six Rupees
And Zero Paisa Only.) shall be recovered from the 1st Running Bill of the Contractor.
2 The Contractor shall be exhibit board as per government circular No.BDG/3277/1657 N dated 26/01/1997 S (M.GUJ) with
detailed specification and details of work and amount Involved at site without any payment as directed by Engineer-In-
3 All work shall be carried out as per public work department hand book and other specifications of Division or as directed.
4 All columns in the Schedule should be filled in ink & the total of the entries in the last column should be struck by Contractor
under his sign.
5 Rates quoted include clearance of site (Prior commencement of work and its close) in all respects and hold good for work
under all condition, site, moisture/ weather etc.
6 The Boards stating the detailed specification & detailes of Work shal be provided by the contractor as per Government
Resolution T.No.1890-240- Dtd.18/11/1990 and directed by contractor at his own cost immediately on recommanding the
7 Testing of Material Shall be done as per the statement attached with specification,The material IS Tested in GERI by
Executive Engineer Surat and Bill for the testing charges shall be paid by Executive Engineer,1% of the Amount put to
8 1% of the Construction Cost Shall be deducted from the bill Amount of the contract as per the Buildig and other
Construction works walfare cess at 1996(Labour and Employment Department Letter No CWA-2004-1831-M(3)Dated
9/12/2005 notification Of Labour & Employment department dt.03/01/2005 & Labou & Employment Department Letter no
9 In Case of RCC items Where there is a change in Grade of Mix or Change as per Actual Mix design the cost of difference of
Cement Difference shall be deducted from the rate of original item at the rate of star rate mentioned in the tender.
10 Contractor are advised to visit site before loading tender rate.
11 Necessary wiring point and drainage point are installed at Site however any modification in electrical installation and
drainage & water supply connection and minor correction to perform experienced in Lab shall be done by contractor at his
12 The Rates are inclusive of all the taxes (Excluding GST),Transport Charges,Octroi duty and storage Charges up to date.
13 The materials Covered for wiring should be got approved from the Engineer Incharge of the work.
14 GST and Income tax TDS will be deducted at a source while making payments of bills.
15 GST will be paid extra as per Govt. amendment.
16 The Materials on the work shall have to be used and carried out as specified in technical note.
I/We hereby Declare that I/we have Visited the site and fully Exquisite myself/ourselves with the local situation regarding
(A) materials,Labour and other factors pertaininfg to work before submitting tender.
I/We hereby Declare that I/we have carefully Studied the condition of Contracts,Detailed Specification and other tender
Document of this work and agree to execute the same accordingly.
Deputy Executive Engineer
Valsad (R&B) Sub-Division
Signature of Bidder
Executive Engineer
Valsad (R&B) Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQ.pdf
Building Booklet.pdf
GR 1.pdf
GR.pdf
NIIT.pdf
SBD.pdf
Specification.pdf
Download all tender documents and submit your bid