| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.6 L+₹73,225 (2.54%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹30.7 L+₹1.8 L (6.38%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹30.8 L+₹1.9 L (6.59%)Rejected-Finance MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹31.1 L+₹2.3 L (7.81%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/S Barua Enterprise L5 | DRISTEE ASSOCIATES L2 | M/S S.K. Sharma L1 | D G Corporation L4 | M/S RHINOTECH BUILDERS L3 | M/S Bharat Construction Co. L6 |
|---|---|---|---|---|---|---|---|---|---|
| 0.00Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender. | |||||||||
| 1.00 | M&L for precast RCC (1:2:4) type B1 (using 20 mm graded stone aggregates) for cover slab of manhole/ soak pit etc set in cement mortar 1:6 including formwork complete all as specified and as directed. | 4 | Cum | 9,000 ₹36,000 | 7,900 ₹31,600 | 7,500 ₹30,000 Lowest | 8,000 ₹32,000 | 8,500 ₹34,000 | 9,200 ₹36,800 |
| 2.00 | Supply and fix PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall 110 mm bore fixed with pipe clamps over walls including dismantling and breaking up drain pipes complete all as specified and as directed. | 250 | RM | 300 ₹75,000 | 260 ₹65,000 | 250 ₹62,500 | 240 ₹60,000 Lowest | 275 ₹68,750 | 290 ₹72,500 |
| 3.00 | Supply and fix PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall 75 mm bore fixed with pipe clamps over walls including dismantling and breaking up drain pipes complete all as specified and as directed. | 300 | RM | 200 ₹60,000 | 175 ₹52,500 | 150 ₹45,000 Lowest | 165 ₹49,500 | 150 ₹45,000 Lowest | 180 ₹54,000 |
| 4.00 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches 150 mm bore including dismantling and breaking up drain pipes complete in all respect as specified and directed. | 300 | RM | 700 ₹2,10,000 | 750 ₹2,25,000 | 800 ₹2,40,000 | 675 ₹2,02,500 | 650 ₹1,95,000 Lowest | 725 ₹2,17,500 |
| 5.00 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches 110 mm bore including dismantling and breaking up drain pipes complete in all respect as specified and directed. | 210 | RM | 300 ₹63,000 | 200 ₹42,000 Lowest | 290 ₹60,900 | 265 ₹55,650 | 250 ₹52,500 | 310 ₹65,100 |
| 6.00 | Excavation in trenches n exc 1.5m wide and n.exc 1.5 m depth for sewage line and manholes, drain etc and getting out in soft/ loose soil complete all as specified and as directed. | 45 | Cum | 300 ₹13,500 | 280 ₹12,600 | 280 ₹12,600 | 275 ₹12,375 | 250 ₹11,250 Lowest | 285 ₹12,825 |
| 7.00 | M&L for plain cement concerete 1:4:8 type D2 (using 40 mm graded stone aggregates as in foundation filling and mass concerete including dismantling of existing surface complete all as specified and directed. | 12 | Cum | 6,500 ₹78,000 | 7,000 ₹84,000 | 6,200 ₹74,400 | 6,250 ₹75,000 | 6,000 ₹72,000 Lowest | 6,600 ₹79,200 |
| 8.00 | M&L for brick work with sub class B bricks, straight or curved on plan exc 6 m mean radius built in CM 1:4 including dismantling of existing surface complete all as specified and directed. | 10 | Cum | 8,400 ₹84,000 | 7,900 ₹79,000 | 8,600 ₹86,000 | 8,500 ₹85,000 | 7,500 ₹75,000 Lowest | 8,000 ₹80,000 |
| 9.00 | M & L for half brick work with sub-class "B" old size bricks of class designation 75, straight or curved on plan built in CM (1:4) including dismantling of existing surface complete all as specified and directed. | 100 | Sqm | 700 ₹70,000 | 600 ₹60,000 Lowest | 680 ₹68,000 | 670 ₹67,000 | 650 ₹65,000 | 725 ₹72,500 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
23 Dec 2025, 6:00 pmClosed
Durg Abhiyanta (Sena), Garrison Engineer (N), Mili
Durg Abhiyanta (Sena), Garrison Engineer (N), Military Engineer Service, PIN 901217 C/o 99 APO
REPAIR AND CLEANING OF MANHOLES, SEWAGE PIPES, SEPTIC TANK, STROM DRAINS AT NAA UNDER GE (N) TEZPUR
2025_MES_742533_1
GE(N)/TEZ/2025-2026/8203
Open Tender
Civil Works
Item Rate
180 days
NAA UNDER GE (N) TEZPUR
AS PER NIT
2 documents required · 2 mandatory
₹500
Garrison Engineer (North)
₹60,000
Yes
13 Feb 2026
2 Dec 2025
24 Dec 2025
2 Dec 2025
23 Dec 2025
16 Dec 2025
2 Dec 2025 - 16 Dec 2025
Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Supply and fix PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall 110 mm bore fixed with pipe clamps over walls including dismantling and breaking up drain pipes complete all as specified and as directed.
Supply and fix PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall 75 mm bore fixed with pipe clamps over walls including dismantling and breaking up drain pipes complete all as specified and as directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches 110 mm bore including dismantling and breaking up drain pipes complete in all respect as specified and directed.
g dismantling of existing surface complete all as specified and directed.
M&L for brick work with sub class B bricks, straight or curved on plan exc 6 m mean radius built in CM 1:4 including dismantling of existing surface complete all as specified and directed.
M & L for half brick work with sub-class "B" old size bricks of class designation 75, straight or curved on plan built in CM (1:4) including dismantling of existing surface complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40 mm graded stone aggregates) for concrete bed to drain pipes including packing under and haunching against side of pipes 100 mm bore after they are laid down, jointed and tested complete all as specified and as directed.
Supply and fix PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall 50 mm bore fixed with pipe clamps over walls including dismantling and breaking up drain pipes complete all as specified and as directed.
Preparaing new undecorated plastered or unplastered surface of wall and apply two coats of white wash complete in all respect as specified and directed.
Supply and fix PVC (SWR) bend of any radius, 110 mm bore with access door complete all as specified and as directed.
Supply and fix PVC (SWR) bend of any radius, 75 mm bore with access door complete all as specified and as directed.
Removing excavated material n.exc 50 m and depositing where directed at level not exc 1.5 m above the starting point complete all as specified and as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using Fe-410W (Grade E-250 quality "A") including necessary welding complete complete all as specified and directed.
M&L for preparation of plastered or unplastered old decorated surfaces of walls, by smole soot, moulds, moss and efflorescence salts and trading oil and greasy spots by scraping , washing with water all as specified, filling cracks/ hole by applying wall care putty (multipurpose mixer shall be used for uniform & proper mixing of putty) and applying one coat of cement base paint white or coloured by auto roller complete in all respect as specified and directed as per manufactures instruction.
M&L for preparation of plastered or unplastered old decorated surfaces of walls, by smole soot, moulds, moss and efflorescence salts and trading oil and greasy spots , washing with water all as specified, filling cracks/ hole by applying wall care putty and applying one coat of weather coat white or coloured complete in all respect as specified and directed.
Supplied and fixed Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete in all respect as specified and directed.
Supply and fix mild steel TMT bar 8 mm dia and over, cut to length, bent to shape as required including cranking bending or hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
Opening of blokage from Manholes Grease trap, Nahni trap, WC, Floor trap, etc including washing/cleaning with pressure pump,upto 1st manhole complete all as specified and as directed. Note:-Opening of blockage up to 7 days interval in one pit in the same place is deemed to be included in the quoted rate and after 7 days of cleaning if bolcked in the same pit shall be measured separately)
Cleaning of sewage line of any diameter by roding of any dia and of any description including manholes by mannually or other means to clear the sludge/ blockage inside the sewage line and manholes and will be flushing with water to drain out sludge etc inside the sewage line from manholes to ease the flow of sewage including removing the sludge and re-fixing the manhole cover complete all as specified and as directed. Note: Minimum two safaiwala alongwith two helpers with tools and plant will be engaged by the contractor per day irrespective of one complaint and complaint will be attended and completed within same day. opening of blockage upto 30 (Thirty) days interval the same place is deemed to be included in the quoted rate and after 30 (thirty) days of cleaning if blocked in the same pit shall be measured separately. complaint slip Book shall be provided by contractor without any extra cost.
Preparaing old
Providing and laying skid/non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick screed bed in cement mortar (CM) 1:6, complete in all respect as specified and directed.
M & L for Broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete in all respect as specified and directed
S & F for 55-60mm thick coloured, glazed pre coated interlocking or without interlocking paver block of any shape and size confirming to IS 15658/1237 with upto date amendments, M-35 Grade with grey cement with pigment laid over fine river bed sand complete in all respect as specified and directed.(Note:- River bed sand shall be measured and paid separately). Sample as approved by GE.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_831491.xls
BOQ • 2.21 MB
Tender8203.pdf
Tender Documents • 1.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .