Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹20.7 L+₹4.2 L (25.2%)Rejected-AOC SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L2 | Rejected-AOC Other Than Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE Chandigarh
GE Chandigarh N Area Pin-160003
REPAIR AND MAINT OF CI/DI/GI AND REPLACEMENT OF OLD CORRODED WATER SUPPLY PIPE LINES, SLUICE VALVE, VALVE PIT OF PUMPING, RISING AND SUPPLY MAIN ETC. AT N AREA AND HALLOMAJRA UNDER GE CHANDIGARH
2024_MES_670545_1
GE/CHD-46/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Chandigarh
Class D category a(ii) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹60,000
Yes
7 Dec 2024
2 Sept 2024
30 Sept 2024
2 Sept 2024
28 Sept 2024
16 Sept 2024
2 Sept 2024 - 7 Sept 2024
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 25 mm bore SDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified.
Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 40 mm bore SDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified.
Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 50 mm bore SDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified.
Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 90 mm bore SDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified.
Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 110 mm bore SDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified.
M&L DI pipe 200 mm (certifugally cast) class 'K-7' (ISI Mark) in any length with spigot and socket ends complete including rubber ring joint (Tyton joint) as per IS- 1536-2001 jointed and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified .
M&L DI pipe 150 mm (certifugally cast) class 'K-7' (ISI Mark) in any length with spigot and socket ends complete including rubber ring joint (Tyton joint) as per I.S- 1536-2001 jointed and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified .
M&L DI pipe 100 mm (certifugally cast) class 'K-7' (ISI Mark) in any length with spigot and socket ends complete including rubber ring joint (Tyton joint)as per IS- 1536-2001 jointed and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified .
M&L DI pipe 80 mm (certifugally cast) class 'K-7' (ISI Mark) in any length with spigot and socket ends complete including rubber ring joint (Tyton joint)as per IS-1536-2001 jointed and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified .
Supply and fixing of CI/DI fittings of size up 150 mm bends ( any radius and angle ) Tapers any type,( straight, bend , increasing,decreasing or double socket etc)Tee pieces single branch. `Y` junction , double branch cross ( all socket or socket and spigot/ flanged as required at site) collars, caps and plugs etc.,complete all as specified.
Rubber gasket joint for 100 mm dia CI flanged pipe complete all as specified
Rubber gasket joint for 150 mm dia CI flanged pipe complete all as specified
Rubber gasket joint for 200 mm dia CI flanged pipe complete all as specified
Supply and fix Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & rubber insertion packing etc for 200 mm bore pipe and fixed, in repairs, complete all as specified.
Supply and fix Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & rubber insertion packing etc for 150 mm bore pipe and fixed, IN REPAIRS, complete all as specified.
Supply and fix Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & 02 Nos rubber insertion packing etc for 100 mm bore pipeand fixed, IN REPAIRS, complete all as specified.
Supply and fix Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & 02 Nos rubber insertion packing etc for 80 mm bore pipe and fixed, IN REPAIRS, complete all as specified.
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm dia, in repairs , complete all as specified.
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 40mm dia, in repairs , complete all as specified.
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 25mm dia, in repairs , complete all as specified.
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 20mm dia, in repairs , complete all as specified.
S&F Cast iron Non return valve of 150 mm dia with provn of two end spoigot and socket suitable for rubber tyton joint and one end flanged fixed with removable MS plate incl ,rubber gas kit,nut,bolt ,washers,and making suitable fixing arrangement to DI 150 MM dia pipe etc complete all as specified . Note : Fitting will be measured and paid separetly, if any, required
S&F Cast iron Non return valve of 100 mm dia with provn of two end spoigot and socket suitable for rubber tyton joint and one end flanged fixed with removable MS plate incl ,rubber gas kit,nut,bolt ,washers,and making suitable fixing arrangement to DI 100 MM dia pipe etc complete all as specified . Note : Fitting will be measured and paid separetly, if any, required.
S&F 100 mm bore cast iron Air release valve with two air outlets complete with fixing arrangement, as in repair complete all as specified and as directed by Engineer-in-Charge.
Arresting of water leakage from existing pipe line in position from DI/CI/GI pipe of size 150 mm to 300 bore ,including excavation through Men/Mechanical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint/CI fitting, nut and bolts,washers and refilling etc complete all as specified . Note:- (i) Excavation up to 1x1x6 Mtr will be deemed to be included in quoted rate. (ii) , DI / CI fitting and pipe length) will be measured and paid saperately under appropriate item of sch 'A' herein. (iii) Cost of new pig lead/lead wool required for repair of leakages is deemed to be included in the quoted rates.
Arresting of water leakage from existing pipe line in position from DI/CI/GI pipe of size 80 mm to 100mm bore ,including excavation through Men/Mechnical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint/CI fitting, nut and bolts,washers and refilling etc complete all as specified . Note:- (i) Excavation up to 1x1x6 Mtr will be deemed to be included in quoted rate. (ii) , DI / CI fitting and pipe length) will be measured and paid saperately under appropriate item of sch 'A' herein. (iii) Cost of new pig lead/lead wool required for repair of leakages is deemed to be included in the quoted rates.
Arresting of water leakage from existing pipe line in position from DI/CI/GI pipe of size 200mm to 300 bore ,including excavation through Men/Mechnical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint/CI fitting, nut and bolts,washers and refilling etc complete all as specified . Note:- (i) Excavation up to 1x1x6 Mtr will be deemed to be included in quoted rate. (ii) Jointing material and pipe length will be measured and paid saperately under approriate item of sch 'A' herein.
Arresting of water leakage from existing pipe line in position from GI pipe of size 40mm to 50mm bore ,including excavation through Men/Mechnical power ,cutting threading,welding as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified . Note:- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rate. More excavation will be measured and paid saperately. (ii) Pipe length will be measured and paid saperately.
Arresting of water leakage from existing pipe line in position from GI pipe of size 15mm to 25mm bore ,including excavation through Men/Mechnical power ,cutting threading,welding as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified. Note:- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rate. More excavation will be measured and paid saperately. (ii) Pipe length will be measured and paid saperately.
Locating blockage in existing distribution pipeline 80mm dia any type in position by excavation work manualy in any type of soil upto 750x500mm upto max 2Mtr length at various location ( Maximum up to 3 location ) incuding necessary cutting/threading/welding work & provision of required size of fittings such as union/socket 1no ,replacement of damaged pipeline,returning filling and removal of surplus soil complete all as specified . Note :- (i) Pipe length will be measured and paid saperately under approriate item of sch 'A' (ii) Contractor shall restore supply system within in 8Hrs.
Locating blockage in existing distribution pipeline 40/50mm dia any type in position by excavation work manualy in any type of soil upto 750x500mm upto max 2Mtr length at various location ( Maximum up to 3 location )incuding necessary cutting/threading/welding work & provision of required size of fittings such as union/socket 1no ,replacement of damaged pipeline,returning filling and removal of surplus soil complete all as specified . Note :- (i) Pipe length will be measured and paid saperately under approriate item of sch 'A' (ii)Contractor shall restore supply system within in 8Hrs.
S&F Run lead joint for 150 mm pipe complete all as specified .
S&F Run lead joint for 200 mm pipe complete all as specified .
S&F Run lead joint for 100 mm pipe complete all as specified .
S&F Run lead joint for 80 mm pipe complete all as specified .
Construction of valve pit chamber of size 120 x120 x120 cm with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thick with locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamel black paint over a coat of red oxide primer to steel surfaces including necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified
Construction of valve pit chamber of size 90 x90 x90 cm with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thick with locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamel black paint over a coat of red oxide primer to steel surfaces including necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified
S&F Rotational moulded polye- thylene water storage tanks of capacity 2000 Ltrs (cylindrical vertical with closed top) 3 layered, hoisted and fixed in position complete including 25mm float valve specified in SSR Part I
S&F Ball brass valves 25 mm dia , high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed →
Cutting of existing cast iron pipe of 150 mm bore for insertion of new tees & branch line of any bore in position including welding complete and all as specified
Cutting of existing cast iron pipe of 100 mm bore for insertion of new tees & branch line of any bore in position including welding complete and all as specified
S&F Tubes 20 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
S&F Tubes 25 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
S&F Tubes 40 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
S&F Tubes 50 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
Cutting and threading existing 15 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) .complete all as directed by the Engineer- in-Charge.
Cutting and threading existing 20 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured)complete all as directed by the Engineer- in-Charge.
Cutting existing 25 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured).complete all as directed by the Engineer- in-Charge.
Cutting existing 40mm to 50 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) complete all as directed by the Engineer- in-Charge.
M/s Friends Engineering Works (BID ID -3118935)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .