| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC 37 MOHAN VATIIKA ACHIEVERS HOME PUBLIC SCHOOL WALI GALI JAGJEETPUR KANKHAL HARIDWAR | HARIDWAR | HARIDWAR | UTTARAKHAND | ₹1.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.8 Cr+₹4.5 L (2.58%)Rejected-AOC OM VIHAR COLONY DELHI ROAD ROORKEE | ₹1.8 Cr+₹4.5 L (2.58%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical HARIDWAR | - | - | Rejected-Technical not qualified in PQR |
Tender Value
₹1.8 Cr
EMD Value
₹3.5 L
Closing Date
19 Jul 2024, 5:00 pmClosed
Superintending Engineer
EDC, Chakrata, Dehradun
REPLACEMENT OF EXISTING RABBIT/WEASEL CONDUCTOR BY AAAC AL-59, 99 SQ. MM COVERED CONDUCTOR OF 11 KV TOWN FEEDER-II, EMANATING FROM 33/11 KV SUB-STATION HERBERTPUR UNDER EDSD, HERBERTPUR UNDER EDD, VIKASNAGAR
2024_UPCL4_73261_1
07/EDCC/2024-25
Open Tender
Electrical Works
Turn-key
120 days
Herbertpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,800
Executive Engineer, EDD, Vikasnagar
₹3.5 L
4 Oct 2024
6 Jul 2024
20 Jul 2024
6 Jul 2024
19 Jul 2024
6 Jul 2024
Amount
Material
Supply of Holding Clamp for SP 33/55 with Nut & Bolts (As Per RESSPO Specification)
Supply of 11 KV AAAC AL 59 Equivlent to 99 sqmm Covered Conductor Equivalent to 300 Amp.
Supply of MVCC accessories as per EN-50397-2 as below
11 KV 90 KN Tension Clamp with Bail and IPC
11 KV Suspension Ties/ Cable Ties on every Pin insulator
11 KV IPC for CC to CC Connection in every Section Pole
11 KV IPC for CC to Bare Connection at both end and tapping
11 KV Mid Span Jointing Kit at every 500 mt. Cable Drum
IPC with Aluminium Bail for earthing 1 No.
Labour
Cartage of following Poles from Store Centre to Nearest Road Site with Loading/Unloading at both points & proper staking (Loading, Unloading & Carriage per pole) (0-20 Km.)
ST Pole SP 33
ST pole SP-55
Cartage of Other Material by Vehicle from Store Centre to Nearest Road Site with Loading/Unloading at both points (0-20 Km.)
Head Load Cartage of following Poles from Road Site to Construction Site (Rates are per Pole/Km, including Loading/Unloading at both points) (0-1 Km.)
ST Pole SP 55
ST Pole SP 33
Head Load Cartage of Small Material by Vehicle from Store Centre to Nearest Road Site including Loading & Unloading at both points (0-1 Km.)
Excavation of Earth for Pole Pit of Size 0.9x0.6x1/6 of Full Length of Pole for Erection of Pole in all type of Soil including Proper Dressing of Sides and Ramming of Bottom including getting out the Excavated Soil and Disposal of Surplus Excavated Soil as directed, Complete Work
Grouting of Pole in Size 0.45x0.45x1/9 of the support in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand) Block including Cost of Cement, Sand and Stone Ballast Back Filling of Soil and Boulders in Pit and Ramming and Proper Alignment, Leveling as per RESSPO Construction Manual
Erection of following Single Support Pole in Proper Level and Alignment alongwith Fixing of all Accessories
STP SP 55
Erection of following Single Support Pole in Proper Level and Alignment alongwith Fixing of all Accessories
STP SP 33
Muffing of Poles Size 0.45cmx0.60cm radious with CC 1:3:6 (1 cement : 3 coarsend : 6 graded stone 10mm nominal size) Block Size 45 cm Height from Ground Level including cost of Cement, Sand & Stone etc.
Proper Alignment of Tilted and Damage Pole
T/F Connection and Jumpering of Covered Conductor
Jumpering and Connection of Section Pole
Painting of Poles with Angle & Channel and all Steel Part by One Coat of Red Oxide Primer and Two Coats of Aluminium Paint and Two Strip of Fluorescent Alternate Red and white Paint 30 Cm. Wide upto 1.5 Mtrs. from Ground Level
Fabrication of M.S. Channel & Angle
Removing of Old Dog Conductor with Opening of Existing, Jumpering and Making of Bundle with Carriage from Pit Site to JE Store including Loading/Unloading, Complete Work (Rabbit/Wesal Conductor)
Laying, Spreading, Stringing and Sagging of 11 KV Line in 3 Phase of the following Wire as Phase Wire including Proper Sagging with Binding and Jumpering as per user Manual and Sagging Chart (inclusive of cartage and head load Cartage at work site). Rollers of the appropriate diameter and quantity have to be provided for installation. The roller shall have a smooth clean surface, no sharp edges and shall rotate easily to prevent the covering from damage any abrasive contact with soil or stone is not permitted, abrasive contact of the covering with branches or similar shall be avoided. Covered conductor shall be pulled by using appropriate pulling devices ensuring that the pulling force is distributed to the conductor recommendation given in EN-50397-3 should be followed for storage transport and installation of covered conductor.
Looping & Chooping of Tree Branches of Route Clearance
Fixing of MVCC accessories
11 KV 90 KN Tension Clamp with Bail and IPC
11 KV Suspension Ties/Cable Ties on every Pin Insulator
11 KV IPC for CC to CC Connection in every Section Pole
11 KV IPC for CC to Bare Connection at both end and tapping
11 KV Mid Span Jointing Kit at every 500 mt. Cable Drum
IPC with Aluminium Bail for Earthing 1 No.
Carriage of Rabbit/Wesal Conductor Scarp Site to JE Store
RAVI CONSTRUCTION CO
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .