| 1 | L1₹22.6 LAccepted-AOC D NO 39 12 27 1 3 MURALI NAGAR VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | ₹22.6 L | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹29.5 LRejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹29.5 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹31.9 LRejected-Finance MIG 330 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | ₹31.9 L | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹32.4 LRejected-Finance D NO 9 9 47 66 DOCTORS COLONY SIVAJIPALEM VISAKHA 530 017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | ₹32.4 L | L4 | Rejected-Finance Not being L1 |
| 5 | Rejected-Technical DOOR NO 2 31 23 SECTOR 7 SBI COLONY MVP VISAKHAPATNAM 530 017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | - | - | Rejected-Technical NOT ENLISTED IN THE CATEGORY c(i). RENEWAL DETAILS NOT FOUND |
| Sl No | Description | Qty | Unit | suresh electricals L2 | UNITY PROJEKTZ L1 | SRIVALLI ENGINEERS L4 | M/s.DSRK CONSTRUCTIONS L3 |
|---|---|---|---|---|---|---|---|
| 1.00M&L for disconnecting electical/ mechanical connections and de-coupling Motor from pump/compressor, taking down the defective Induction Motor of any make / model shifted to work shop for dismantling motor, remove burnt out winding from stator and rewinding the stator with same gauge super enamelled copper conductor with necessary insulation materials, varnishing backing re-assembling motor including replacement of both end bearings complete after complete the job motor shifted to site and reinstalled at its original position including allignment with pump/compressor with electrical connections and testing for best performance complete all as specified and directed of the following capacities :- | |||||||
| 1.01 | Motor up to 5 HP | 15 | Each Job | 11,000 ₹1.6 L | 7,200 ₹1.1 L | 9,000 ₹1.4 L | 10,000 ₹1.5 L |
| 1.02 | Motor upto 10 HP | 12 | Each Job | 14,500 ₹1.7 L | 8,100 ₹97,200 | 13,000 ₹1.6 L | 13,000 ₹1.6 L |
| 1.03 | Motor upto 15 HP | 9 | Each Job | 16,500 ₹1.5 L | 9,000 ₹81,000 | 17,000 ₹1.5 L | 15,500 ₹1.4 L |
| 1.04 | Motor upto 20 HP | 6 | Each Job | 18,500 ₹1.1 L | 12,000 ₹72,000 | 19,000 ₹1.1 L | 18,500 ₹1.1 L |
| 1.05 | Motor upto 30 HP | 2 | Each Job | 26,000 ₹52,000 | 15,000 ₹30,000 | 29,000 ₹58,000 | 23,500 ₹47,000 |
| 2.00M&L for Repair and reconditioning of monoblock pump/ centrifugal pump connection after disconnecting and degutting the pump from foundation and transporting to the work shop. Pump should be dismantled completely and inspection shall be carried out. After complete inspection of the pump any machining jobs shall be carried out. Mechanical seals, gland packing, o-rings and other consumbles will be renewed major over hauling of the pump shall be carried out and boxed back test bed trails will be carried out at work shop at 1.5 times the working pressure. Pumps shall be transported back to INS Kalinga and regutting to be done and pump shifted to site and reinstalled at its original position including allignment with pump/ motor with electrical connections and testing for best performance complete all as specified and directed of the following capacities :- | |||||||
| 2.01 | Pump up to 5 HP | 12 | Each Job | 6,800 ₹81,600 | 7,200 ₹86,400 | 5,000 ₹60,000 | 7,000 ₹84,000 |
| 2.02 | Pump upto 10 HP | 10 | Each Job | 11,000 ₹1.1 L | 8,100 ₹81,000 | 9,000 ₹90,000 | 12,000 ₹1.2 L |
| 2.03 | Pump upto 15 HP | 6 | Each Job | 13,500 ₹81,000 | 12,000 ₹72,000 | 12,000 ₹72,000 | 15,000 ₹90,000 |
Updated dates
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
30 Dec 2025, 6:00 pmClosed
CWE NO 2 VISAKHAPATNAM
CWE NO 2 VISAKHAPATNAM, HQ CE N COMPLEX, RAILWAY STATION ROAD, VISAKHAPATNAM - 530004
MAINTENANCE TO VARIOUS CAPACITY OF CENTRAL TYPE AC PLANTS OF VARIOUS MAKE AND REPAIRS TO ASSOCIATED MOTORS, PUMP SETS AND OTHER CONNECTED WORKS AT NAVAL STATION BHEEMUNIPATNAM UNDER CWE NO 2 VISAKHAPATNAM
2025_MES_742547_1
82754
Open Tender
Machineries/ Mechanical Engg Items
180 days
GE P NAVY KALINGA
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (P) (N) KALINGA
₹88,000
Yes
15 May 2026
2 Dec 2025
6 Jan 2026
2 Dec 2025
30 Dec 2025
16 Dec 2025
2 Dec 2025 - 16 Dec 2025
M&L for disconnecting electical/ mechanical connections and de-coupling Motor from pump/compressor, taking down the defective Induction Motor of any make / model shifted to work shop for dismantling motor, remove burnt out winding from stator and rewinding the stator with same gauge super enamelled copper conductor with necessary insulation materials, varnishing backing re-assembling motor including replacement of both end bearings complete after complete the job motor shifted to site and reinstalled at its original position including allignment with pump/compressor with electrical connections and testing for best performance complete all as specified and directed of the following capacities :-
Motor up to 5 HP
Motor upto 10 HP
Motor upto 15 HP
Motor upto 20 HP
Motor upto 30 HP
M&L for Repair and reconditioning of monoblock pump/ centrifugal pump connection after disconnecting and degutting the pump from foundation and transporting to the work shop. Pump should be dismantled completely and inspection shall be carried out. After complete inspection of the pump any machining jobs shall be carried out. Mechanical seals, gland packing, o-rings and other consumbles will be renewed major over hauling of the pump shall be carried out and boxed back test bed trails will be carried out at work shop at 1.5 times the working pressure. Pumps shall be transported back to INS Kalinga and regutting to be done and pump shifted to site and reinstalled at its original position including allignment with pump/ motor with electrical connections and testing for best performance complete all as specified and directed of the following capacities :-
Pump up to 5 HP
Pump upto 10 HP
Pump upto 15 HP
Pump upto 20 HP
M&L for carrying out the complete leak rectification of the direct expansion system of following capacity central AC plants consisting of compressors, condensers, liquid & suction and discharge lines, and evaporator coil/ chiller and pressure control valves & lines and gauge board with Nitrogen gas, locating the leaks and rectifying the leaks and flushing the complete system and pressure testing & holding the pressure for 24 Hours complete all as specified and directed.
30 TR capacity Chiller system
50 TR capacity Chiller system
S&F in repairs DOL starter suitable for 5HP to 10 HP motor complete over load relay ,single phasing preventer under volt release etc. all as per existing complete all as specified and directed.
Ball bearing 6204
Ball bearing 6205
Ball bearing 6206
Ball bearing 6207
Ball bearing 6208
Ball bearing 6209
Ball bearing 6210
Ball bearing 6211
Ball bearing 6312
Ball bearing 6313
Supply only Digital step controller display complete set for hot water genertaor 80 KW (Model: RC-80, Make: Rapid cool) complete all as specified and directed.
Supply only Controle Module card with relay complete set for hot water genertaor 30 KW (Model: RC-30, Make: Rapid cool) complete all as specified and directed.
Supply only immersion type water heater assembly of capacity 25 KW suitable for Emrald make hot water generator complete all as per existing model and make complete all as specified and directed.
Supply only immersion type water heater assembly of capacity 15KW suitable for Emrald make hot water generator complete all as per existing model and make complete all as specified and directed.
Supply only Thermostat (30 to 110) ANCO DX-110 suitable for Rapid cool Make hot water generator complete all as per existing model and make complete all as specified and directed.
Supply only Limit Switch suitable for Rapid cool Make hot water generator complete all as per existing model and make complete all as specified and directed.
Supply only Water Thermostat suitable for Rapid cool Make hot water generator complete all as per existing model and make complete all as specified and directed.
Supply only Air Release Valve suitable for Rapid cool Make hot water generator complete all as per existing model and make complete all as specified and directed.
Supply only Rubber Gasket suitable for Rapid cool Make hot water generator complete all as per existing model and make complete all as specified and directed.
M&L for complete rectification testing overhauling of Hot water generator (Make: Rapid cool or any other make ) replacing the damaged spare parts to running condition replacement unserviceable parts digital step controller display ,relay ,heater assembly ,contactors, checking of serviceable and operational condation of hot water generator , complete all as manufacturees instruction all as specified and directed. Note : (i) The rate quoted shall be deemed to included for labour, T&P,MS nuts,bolts, painting etc . (ii) Supply only spare parts will be measured and paid seperately against respective item and the unit rate quoted shall deemed to included the cost of labour for fixing the spares .
S&F in repairs Digital ammeter 3 phase, 5 amps, class 1, AC supply as fixed for existing panel complete all as specified and directed.
Dismantling/taking down the old damaged /corroded part of the fondation of motor and pumps renewed foundation of motor and pump incl MS support channel, hard standing painted in existing colour and proper alignment of motor, pump complete all as specified and directed.
2''x6''x2'' size.
2''x12''x2'' size .
Notes: (i) In case of delay in the rectification of any defects is more than 24 hours for minor defects and more than 72 hours for major defects, the GE may at his absolute discretion to impose on the contractor to pay to the department a penalty of Rs 5,000/- for minor defects and Rs 10,000/- for major defects towards inconvenience caused to the users. The decision of the GE as to whether a particular defect occured is minor or major will be the final and binding. The above penalty shall be in addition to the provision made in condition 50 of IAFW-2249.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
TENDER.pdf
Tender Documents • 0.88 MB
BOQ_831506.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid