Executive Engineer ED Baramulla
Executive Engineer ED Baramulla
Procurement and installation of street lights at salamabad Uri Under CSR Sector 2023-24
2024_PDD_244707_1
EDB/125
Open Tender
Electrical Works
Turn-key
45 days
Procurement and installation of street lights at s
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,009
Yes
Executive Engineer ED Baramulla
₹28,860
Yes
25 Apr 2024
10 Feb 2024
11 Mar 2024
10 Feb 2024
9 Mar 2024
12 Feb 2024
10 Feb 2024 - 12 Feb 2024
Amount
Supply,Carraige upto site, Installation, testing and Commissioning of 11/0.433kV, 25kVA 3-Phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Alminium wound and with LV Cable Box having detachable Alminium Gland plate with LV Bimetallic terminal connection suitable for vertical take off cable.
Supply,Carraige upto site, Installation, testing and Commissioning of 15kVA AVR (Alminium Wound) Three Phase complete job along with all accessories
Supply,Carraige upto site, Installation, testing and Commissioning of 120Watt LED Luminaries of IP67 protection
Supply,Carraige upto site, Installation, testing and Commissioning of Surge protector for the 120Watt LED type lighting fixture complete
Supply, Carriage up to site, laying ,stringing, tensioning , binding of ACSR Conductor, (30mm2 ACSR Conductor)
Supply,Carraige upto site, Erection, testing and commissioning of Steel Tubular Pole, 9 Mtr. Long Pole(ST-410 SP33) with planting depth of 1/6 th of the height of the pole, (9 mtr. Long )
Supply, Carriage up to site, Erection, testing and commissioning of Steel Tubular Pole, 8 Mtr. Long Pole(SP15) with planting depth of 1/6 the of the height of the pole, (8 mtr. Long )
Supply,Carraige upto site, Installation, testing and Commissioning of G.I Channel / Angle / Flat of sizes including Clamps
Supply,Carraige upto site, Installation, testing and Commissioning of 11KV Polymeric composite pin insulators 12kV, 5kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm
Supply,Carraige upto site, Installation, testing and Commissioning of 11KV G.O, AB switch 3-phase, 3pole,200Amp, vertical type
Supply,Carraige upto site, Installation, testing and Commissioning of 11kV Horn Gap Fuse Set 3 Phase 200A
Supply,Carraige upto site, Installation, testing and Commissioning of 11kV Gapless surge arrestor, 9 kV, 10kA, LA with polymer housing station type
Supply,Carraige upto site, Installation, testing and Commissioning of LT Distribution Box for 25kVA DTR with 400Amp MCCB 3P 16kA for incomer & 25Amp MCCB 3P 16KA/10kA 1No. Each (=2No.) for outgoing circuit.
Supply,Carraige upto site, Installation, testing and Commissioning of 35sqmm Single core cable 1.1kV Grade XLPE insulated Stranded conductor FRLS type
Supply,Carraige upto site, Installation, testing and Commissioning of Earthing complete by GI pipe 40mm 3mtr long through GI strip 25X3mm
Supply,Carraige upto site, Installation, testing and Commissioning of Pre fabricated galvanized single way top bracket (1000mm long with 48.3 OD GI pipe) to be fitted on top of octagonal pole for holding the lightining
Supply,Carraige upto site, Installation, testing and Commissioning of DK thermoplastic cable junction / Termination T boxes 8"X10" of class IP55/IP65 fitted with two 2-5Amp MCB strip, 4Way terminal block/connectors including copper lugs, clamps, nut&bolts, washers etc. (Hansel or equivalent make) or poles with two way type bracket to be fitted properly inside the door opened gear box provided on the bottom side of the pole.
Supply,Carraige upto site, Installation, testing and Commissioning of 3X1.5sqmm PVC insulated multistrand flexible copper wire for service connection from connection plate to the LED Luminary individual circuit including loop & earthing laid properly
Supply,Carraige upto site, Installation, testing and Commissioning of HDPE pipe 50mm OD and inner dia 38mm including trench excavation in hard soil (0.3X0.45X1000m) for laying of 25/16sqmm Al. Armoured cable. The job further includes refilling back the same and removal of surplus excavated material to an appropriate place.
Supply,Carraige upto site, Installation, testing and Commissioning of LT 25sqmm 4core Alminium XLPE Armoured cable to be carried through conduit/pipe U/G or A/G only in case of site constrains excluding cost of pipe & trench excavation. The cable shall include end termination lugs with its crimping / taping.
Supply,Carraige upto site, Installation, testing and Commissioning of LT 16sqmm 2core Alminium XLPE Armoured cable to be carried through conduit/pipe U/G or A/G only in case of site constrains excluding cost of pipe & trench excavation. The cable shall include end termination lugs with its crimping / taping.
Supply,Carraige upto site, Installation, testing and Commissioning of Dust/Rain/Snow proof canopy type mini outdoor LT feeder panel of size 450X300mm with front door opening duly powered colour coated with inbuilt 2No TPN 16-32Amp legs grouted in the cement concrete of termination of mainb 25sqmm cable and outgoing 25/16sqmm cable circuits.
Supply,Carraige upto site, Installation, testing and Commissioning of Sundry items like Aluminium lugs, Jumpers, Binding tapes etc.
Supply,Carraige upto site, Installation, testing and Commissioning of Galvanised Nuts & Bolts
Supply,Carraige upto site, Installation, testing and Commissioning of Earthing of Sub Station --Excavation of earth pit dia 650mm & depth 3000mm, installation of earthing pipe pf 40mm nominal bore & 4mm wall thickness & length 2.5mtr long as per IS 1239. GI strip for neutral earthing of size 25mmX3mm for connection of transformer body, GO set & lightening arrestors as per IS 2629/85, GI nut & bolts refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.
Supply,Carraige upto site, Installation, testing and Commissioning of Cement bottoming 1:2:4 as per standards 0.5cum / pole
Supply,Carraige upto site, Installation, testing and Commissioning of Cement bottoming 1:2:4 as per standards 0.45cum / pole
Providing & Painting of Poles with one coat of Red Oxide and two coats of aluminium paint and along with pole marking.
Supply,Carraige upto site, Installation, testing and Commissioning of Danger Plate with clamps
Supply,Carraige upto site, Installation, testing and Commissioning of Anti climbing device with clamps
Supply,Carraige upto site, Installation, testing and Commissioning of 3Phase,4Wire Prodigy meter Suitable for 25kVA S/S
M/S SUZAIN ENTERPRISES
CHALKOO ENGINEERING WORKS
M/S ZARGAR ENGINEERING WORKS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .