Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹376.9 CrAccepted-AOC GODREJ WATERSIDE TOWER NO 1 OFFICE 803 8TH FLOOR PLOT NO 5 BLOCK DP SECTOR V SALT LAKE CITY KOLKATA 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | ₹376.9 Cr | L1 | Accepted-AOC Accepted L1 Bidder. |
| 2 | L2₹403.4 CrRejected-Finance | ₹403.4 Cr | L2 | Rejected-Finance Other than L1 Bidder. |
| 3 | L3₹419.9 CrRejected-Finance NCC HOUSE MADHAPUR HYDERABAD 500081 TELANGANA INDIA TELEPHONE 040 23268730 | ₹419.9 Cr | L3 | Rejected-Finance Other than L1 Bidder. |
| 4 | Rejected-Technical B 22 2ND FLOOR HIMALAYA HOUSE 23 K G MARG CANNAUGHT PLACE NEW DELHI 110 001 | NEW DELHI | DELHI | 110001 | - | - | Rejected-Technical Please refer LIST OF TECHNICALLY QUALIFIED AGENCY |
Tender Value
Refer Docs
EMD Value
₹10 L
Closing Date
30 Sept 2019, 3:00 pmClosed
Superintending Engineerand Project DirectorProject
Office of the Superintending Engineer and Project DirectorProject Implementation Unit - I,P.W. (Roads) Directorate 3No. Commissariat RoadHastingsKolkata-700022
Construction of Circuit Bench of Calcutta High Court at Jalpaiguri. (2nd Call)
2019_WBPWD_242288_1
WBPWD/PW(R)/SEPD/PIU-I/NIT NO-69 OF 2019-2020
Open Tender
CIVIL AND ELECTRICAL WORKS
540 days
JALPAIGURI
Please refer Tender documents.
8 documents required · 8 mandatory
₹10 L
Yes
Project Implementation Unit - I, P.W.(Roads) Direc
19 Feb 2021
5 Sept 2019
3 Oct 2019
5 Sept 2019
30 Sept 2019
17 Sept 2019
12 Sept 2019
Amount
SECTION (A) : MAIN BUILDING Providing Bored Cast-in-situ M-25 Grade R.C.C. pile in position as per specifications in all kinds of soil including cost of boring using drilling mud to stabilize the bore and flushing the bore of excess mud with freshly prepared drilling fluid by using pumps prior to placing concrete by tremie pipe in one continuous operation and including the cost of all materials and labour for placing of concrete and also including the cost of mobilization and hire charges of all equipment necessary for boring, welding of reinforcement cage as necessary and lowering of reinforcement cage, preparation and placing of concrete, including the cost of concrete but excluding the cost of reinforcement and labour for bending binding etc. complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Work to be executed as per IS: 2911 (Part II Sec 2). Using hydraulic piling rig. Pile diameter - 500 mm.
SECTION (A) : MAIN BUILDING Providing Bored Cast-in-situ M-25 Grade R.C.C. pile in position as per specifications in all kinds of soil including cost of boring using drilling mud to stabilize the bore and flushing the bore of excess mud with freshly prepared drilling fluid by using pumps prior to placing concrete by tremie pipe in one continuous operation and including the cost of all materials and labour for placing of concrete and also including the cost of mobilization and hire charges of all equipment necessary for boring, welding of reinforcement cage as necessary and lowering of reinforcement cage, preparation and placing of concrete, including the cost of concrete but excluding the cost of reinforcement and labour for bending binding etc. complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Work to be executed as per IS: 2911 (Part II Sec 2). Using hydraulic piling rig. Pile diameter - 750 mm.
Providing MS casing pipe around RCC cast-in-situ bored piles of different diameters in position including cost of all materials, fabrication, handling etc. complete as per direction of Engineer-in- Charge.
Integrity testing of Pile using Low Strain / Sonic Integrity Test / Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerized equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer incharge. North Zone
Performing Vertical load test on single Pile in accordance with IS:2911(Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design load including preparation of the head of piles with concrete of required strength for receiving the jacks with all ancillary arrangements for setting up gauges, construction of suitable platforms, keeping the loads and dismantling and removing all arrangement etc. complete as per IS specification and direction of Engineer-in-charge. Testing load between 100 T and 150 T.
Performing High Strain Dynamic Pile Load testing by using Pile Driving Analyzer as per IRC: 78-2014 standard procedure with a hammer of suitable weight (1-2% of the test load or 5-7% of the dead load on the pile or suitable energy as decided by Engineer-in charge). The rate is inclusive of construction of suitable platform, fixing of strain sensor & accelerometer, charges for hammer hoisting arrangement & removing etc. The rate is also inclusive of cost & carriage of all materials, completion of field test, CAPWAP analysis & submission of test results along with reports as perb) For Test load 101 to 300 MT For North Bengal
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
in fifth floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel/Mild Steel. SAIL/ TATA/RINL For works in foundation, basement and upto roof of ground floor/upto 4 m in ground floor
In first floor
In second floor
in third floor
in fourth floor
in fifth floor
Batch Mixed concrete of M 30 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 320 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
In first floor
In second floor
in third floor
in fourth floor
in fifth floor
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, as per relevant IS codes. Pakur Variety. IN GROUND FLOOR
First floor
Second floor
Third floor
Fourth Floor
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i) Shuttering without staging in foundation.
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. In ground floor
In first floor
in second floor
in third floor
in fourth floor
in fifth floor
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation.
Filling in foundation or plinth by Find sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity )
Brick work with 1st class bricks in cement mortar (1:6). In foundation and plinth
In superstructure Ground Floor:
1st floor
2nd floor
3rd floor
4th floor
5th floor
String course up to 75 mm projection and upto 150 mm depth 15 mm thick plasterd (1:4) (including stripping off old surface where necessary) complete. (Cement 6.6Kg/Mtr.) In all floors
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) In ground floor.
First floor
Second floor
Third floor
Fourth Floor
Extra for using approved H.B netting in every third layer in 125 mm thick brick work (1:3) in any floor.
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx).
Band Moulding (horizontal or vertical) rectangular section made with cement plaster (1:4) complete. Projection 25 mm Depth or width (75 mm to 100 mm) (Cement 1.25 kg/mtr.) in ground floor
in first floor
Second floor
Third floor
Fourth Floor
fifth floor
Projection 40 mm Depth or width (125 mm to 150 mm) (Cement 2.6 kg/mtr.) In ground floor
in first floor
Second floor
Third floor
Fourth Floor
fifth floor
Multiple-band moulding (horizontal or vertical) made with 15mm cement plaster (1:4) complete :(i) Projection 25 mm (b) Depth or width (75 mm to 100 mm) (Cement 2.50 kg/mtr.) in ground floor
first floor
Second floor
Third floor
Fourth Floor
fifth floor
Projection 40 mm Depth or width (125 mm to 150 mm) (Cement 3.5 kg/mtr.) In ground floor
first floor
Second floor
Third floor
Fourth Floor
fifth floor
Band moulding (horizontal or vertical) of rectangular section made with 15 mm thick cement plaster (1:4) on brick projection or concrete projection (excluding the cost of such brick or concrete projection). Projection 75 mm Depth or width (75 mm to 150 mm) (Cement 2.46Kg/Mtr.) in ground floor
first floor
Second floor
Third floor
Fourth Floor
fifth floor
Projection above (75 mm. and upto 150 mm) Depth or width (75 mm to 150 mm) (Cement 3.3Kg/Mtr.) In ground floor
first floor
Second floor
Third floor
Fourth Floor
fifth floor
Expansion joint in floor roof etc. formed with V strips made of 22.5 cm wide strips of 24 gauge aluminium sheets with anchor arm projecting on each side (and end turned ) embedded in adjacent cement concrete, including shaping and finishing the edges on either side of the joint (including the cost of bituminous filler if any) complete as per direction.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:6 cement mortar. 20 mm thick plaster In Ground Floor
first floor
Second floor
Third floor
Fourth Floor
fifth floor
With 1:4 cement mortar. 10 mm thick plaster In Ground Floor
first floor
Second floor
Third floor
Fourth Floor
fifth floor
With 1:6 cement mortar 15 mm thick plaster In Ground Floor
first floor
Second floor
Third floor
Fourth Floor
fifth floor
Labour for Chipping of concrete surface before taking up Plastering work.
Extra for fluted, corrugated or ribbed plaster (over rate of corresponding rate of plaster). (In 1:3 Cement:Sand)
Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse)
Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Agency]
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand (1.5mm thick).
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand. (1.5 mm thick) In Ground Floor
first floor
Second floor
Third floor
Fourth Floor
fifth floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coats. Solvent based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) Luxury Quality
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coats in ground floor
First floor
Second floor
Third floor
Fourth Floor
fifth floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Super Protective 100% Acrylic Emulsion. In ground floor
First floor
Second floor
Third floor
Fourth Floor
fifth floor
Partition with soft insulation board (of 12mm thick) as per relevant IS Code and Drawing & design fitted and fixed complete (excluding the supporting framework but including necessary teak wood battens of size 40 mm & 25 mm). In Ground Floor Ordinary Teak
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. 32 mm thick in ground floor
First floor
Second floor
Third floor
Fourth Floor
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. 66mm x 90mm
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings as per design & drawing approved by the E-I-C. 50mm thick shutters with 25mm thick panel of size 30 to 45 cm 1st class best Indian teak. in ground floor
First floor
Second floor
Third floor
Fourth Floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Siliguri. in ground floor
First floor
Second floor
Third floor
Fourth Floor
Supplying bubble free float glass of approved make and brand conforming to IS: 2835- 1987; Clear, toughened glass conforming to IS: 2553-1992 (part-II) 6mm thick
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs. Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. In ground floor
First floor
Second floor
Third floor
Fourth Floor
fifth floor
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. in ground floor
First floor
Second floor
Third floor
Fourth Floor
fifth floor
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering.
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On timber or plastered surface : With super gloss (hi-gloss) - Two coat (with any shade except white)
On steel or other metal surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) 40mm X 6m m, 250mm Length
Providing and fixing exterior quality Aluminium Composite panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer in-charge. (Mode of payment is on finished surface area of ACP) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating)
Oxidised Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 75mm. X 60mm. X 3.15mm
100mm. X 75mm. X 3.5mm
Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. 300mm long.
Anodised Aluminium barrel /tower /socket bolt of approved quality fitted and fixed complete 150mm long x 10mm dia bolt.
225mm long x 12mm dia bolt.
Godrej Hydraulic door closer fitted and fixed complete. Heavy type
Supplying 6 levers 'Godrej' Crystal Satine Mortice Lock with keys including fitting & fixing complete.
Door stopper.(Brass)
Anodised aluminium grip handle with base plate of approved quality fitted and fixed complete. With base plate. 165 mm grip x 12 mm dia x 42 mm plate x3.2 mm thick.
300mm grip x 20mm dia rod x 50mm plate x 3.2mm thick.
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Wall With Polymerised Adhesive and Epoxy grout pointing including spacer - 2 mm ( When Tiles are laid over existing hard ready surface. Area of each tile above 0.09 Sq.m [using adhesive 4.5 mm thick] Coloured decorative In ground floor
First floor
Second floor
Third floor
Fourth Floor
Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. (Excluding cost of glass/ panel board) 10-12 Micron thickness Annodizing film. Natural white. For unsupported length of vertical member upto 1.50m. height of both ends of vertical member restrained but panel with in 0.90 sqm.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. vi) 6mm thick coloured / tinted / smoke glass.
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineerin- Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) Size not Iess than 800mmX 800 mm X 10.2 mm thick In first floor
Second floor
Third floor
Fourth Floor
M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete) In ground floor
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointedwith white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. [White cement and Pigment to be supplied by the Agency] With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana Area of each slab/tile exceeding 1.00 sq.m In ground floor
First floor
Second floor
Third floor
Fourth Floor
Providing and fixing machine cut, mirror polished, Italian Marble stone (Imported quality, such as Perlato, Bottichino, Crema, Antique Beige, Dark Emperadore, Red Verona, Black Marquino etc.) flooring laid in required pattern in linear portion of the building all complete as per architectual drawings with Italian Marble stone slab laid over 20 mm (average) thick base of cement morter 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry mixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. White with veins 18 mm thick Italian Marble stone slab In first floor
Second floor
Third floor
Fourth Floor
More white with less veins 18 mm thick Italian Marble stone slab In first floor
Supplying, fitting, fixing marble slab/tiles, 15 mm. to 18 mm. thick in dado / wall in 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks applying white cement slurry @ 4.4 kg/ sq.m at the back side of marble & pointing in cement mortar (1:2) (1 cement, 2 marble dust) with admixture of pigment matching the stone shades including polishing all complete as per direction of the Engineer incharge including cost of materials, labours, scaffolding, staging, curing complete. [White cement, Pigment to be supplied by the Agency] With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur Pink / Udaypur green / Black Bhalsana Area of each tile exceeding 0.3sq.m. but not exceeding 0.6 sq.m. In ground floor
First floor
Second floor
Third floor
Fourth Floor
Supplying fitting and fixing 15 to 18 mm thick Marble slab/Tile in riser of step or skirting (upto 300 mm ht) over 15mm (avg) thick base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/ Sq.m at back side of marble and jointed with white cement slurry @ 2.2 kg/ Sq.m with necessary pigments including grinding and Granite Polishing. [White cement and Pigment to be supplied by the Agency] With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana Area of each tile exceeding 0.3sq.m. but not exceeding 0.6 sq.m. In ground floor
First floor
Second floor
Third floor
Fourth Floor
Extra cost of labour for Marble Stone Floor in treads of Steps.
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in Floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and Pointing @2.0 kg/Sq.m In ground floor
in first floor
Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrange- ment to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour,scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4kg/Sq.m and for jointing @1.8 kg/Sq.m] In ground floor
in first floor
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable Area of each granite slab 0.60 to 1.00 sqm In ground floor
First floor
Second floor
Third floor
Fourth Floor
fifth floor
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. Area of each Granite slab above 1.00 sqm In ground floor
First floor
Second floor
Third floor
Fourth Floor
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. UPVC Pipes: 110 mm. Dia.
UPVC Fittings: Bend 87.5 degree 110 mm. Dia.
Shoe 110 mm. Dia.
Pre-Constructional Anti-termite measures: (c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) For Exposed Work PVC Pipes 15 mm dia.
20 mm dia.
25 mm dia.
32 mm dia
40 mm dia.
50 mm dia.
100 mm dia.
150 mm dia.
For Concealed Work (Dia) 15mm dia.
20mm dia.
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) 50 mm dia.
150 mm dia.
Supplying, fitting and fixing shower of approved brand and make. Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand).
Chromium plated Hand shower with Flexible Tube & fittings(Equivalent to Code No. Hsh-1937 & (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar).
Chromium plated double coat Hook(Equivalent to Code No. 35761 & Model - KUBIX of Jaquar or similar)
hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook (Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 100 mm dia.
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 100 mm dia.
50 mm dia.
40 mm dia.
25 mm dia.
20 mm dia.
Supplying, fitting and fixing bib cock or stop cock. Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Chromium plated Concealed Stop Cock (Equivalent to Code No. 514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Chromium plated Bib Cock (angular shape with wall flange) (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar brand).
Chromium plated Bib Cock with wall flange (Equivalent to Code No. 5047 & Model - Florentine of Jaquar or similar brand)
Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
Chromium plated concealed Stop Cock heavy duty (Equivalent to Code No. 5083 & Model - Florentine of Jaquar or similar brand).
Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm. 25 mm dia.
C.I. sluice valve with flanged ends drilled to as per I.S. 1358/62 and having all cast iron components as per I.S. 780/71 solid forged bronze inside screw spindle having ultimate tensile strength not less than 4.72 MT per sq. cm. Spindle nut valve and seat faces of hard wear resisting, manufactured from best quality gunmetal conforming to I.S. 780/71, painted black all over with asphalt base paint tested to 21 kg (hydraulic pressure) per sq. cm., valve opening to anticlockwise direction, fitted and fixed complete. 150 mm dia.
Sluice valve chamber with C.I. heavy cover with locking arrangement, (weight not less than 25 kg) (size of chamber 450 mm X 600 mm inside upto 900 mm depth) 250 mm thick cement brick walls (6:1), 150 mm thick cement concrete (6:3:1) bed with stone chips, 20 mm thick cement plaster (6:1) for inside wall and 15 mm thick cement plaster (4:1) for outer walls including rounding corners.
Supplying, fitting and fixing C.I. tail pieces in pair conforming to I.S. specifications. 100 mm
Supplying, fitting and fixing cast iron spun pipe conforming to I.S. 1536/1976 with all necessary specials including cutting trenches in any soil or through masonry, concrete etc., if necessary,and mending good all damages including jointing pipes with Tyton joints as per manufacturer's specifications and filling up the trenches all complete but excluding the cost of masonry or concrete work, if required. Class A : 150 mm nominal dia.
Supply, Fitting & Fixing 3 layer PP-R (Poly-propylene Random Copolymer) U.V STABILISED and anti-microbial fusion welded pipes conforming to IS:15801-2008.for hot & cold water supply including necessary fittings and joining materials as required complete as per direction of Engineer-in-charge. (Payment will be made on the centre line measurement of the total pipe line including all specials. No seperate payment will be made for accessories, specials etc.) For Concealed Work SDR 7.4/PN-16 Pipes 25 mm ( outer dia.)
Supply, Fitting & Fixing of PVC Bottle waste tap. 40 mm
Supply, Fitting & Fixing of Polythene flange. 50 mm dia.
Supplying, fitting and fixing 10 litre porcelain low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internnal PVC fittings. Burgandy, Emerald green coloured.
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing concealed cistern of approved make with flash plate Cute/Loop/Shell/ Nova (Code No. concealo-H (80mm Body sap code 508179 of Hindware or equivalent). Matt/Gloss
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2000 litre capacity
Labour for hoisting plastic water storage tank. Above 1500 litre upto 5000 litre capacity. At the roof of 5th Floor.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size. Coloured Basin. Burgandy, Emeral Green coloured
630 mm X 450 mm size. Coloured Basin. Burgandy, Emeral Green coloured
Supplying, fitting and fixing pedestal of approved make for wash basin. Coloured pedestal Burgandy, Emeral Green coloured
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. 600 mm long
Supplying, fitting and fixing complete Bottle waste trap (Heavy Quality). Chromium plated Bottle trap 32 mm with 190 mm long connecting pipe and wall flange (Equivalent to Code No. 545 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand).
Supplying, fitting and fixing pillar cock of approved make. CP Pillar Cock Super Deluxe with Aerator - 15 mm. (Equivalent to Code No. 508 & Model No. Tropical / Sumthing Special of ESSCO or similar brand).
CP Pillar Cock - 15 mm. (Code No. 5011 & Model - FLORENTINE of JAQUAR or equivalent). Code No. 508 & Model No. Tropical / Sumthing Special of ESSCO or similar brand)
CP Centre hole Basin mixture with regular spout without popup waste system with 450 mm long braided hoses. (Equivalent to Code No. 5167(B) & Model - FLORENTINE of JAQUAR or similar brand).
CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand).
CP Pillar Cock with 200 mm extended Lever Handle (Equivalent to Code No. 5031 & Model - FLORENTINE of JAQUAR or similar brand)
Supplying, fitting and fixing C.P. Wall Flange
Supplying, fitting and fixing dome shaped C.P. waste grating for urinals. 50 mm
Supplying, fitting & fixing chrome plated brass battery based infrared sensor oprated pillar cock , having foam flow technology. (Model: Pillar Sensor Faucet of Hindware or similar brand). 15 mm normal bore
Supplying, fitting and fixing street pattern hydrant 65 mm with guaranteed spindles and C.I.cover complete.
Supplying, fitting and fixing C.I. cover for street pattern hydrant.
Supplying, fitting & fixing Cast iron soil pipe only conforming to I.S. 3989 / 1970 and I.S. 1729/1964 with bobbins, nails etc. including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (Measurement will be made along the center line of the total pipe line in fitted condition including specials,payment for specials & Painting will however be paid seperately).(a) With valamoid joints including sealing with sand cement morter (4:1) upto quarter depth. 150 mm dia. (internal)
100 mm dia. (internal)
75 mm dia. (internal)
Supplying, fitting & fixing Cast iron single branch equal with door conforming to I.S. 1729/1970 including joining and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). With valamoid joints including sealing with sand cement morter (4:1) upto quarter depth. 150 mm dia.
100 mm dia.
75 mm dia.
Supplying, fitting & fixing Cast iron double branch equal with door conforming to I.S. 1729/1970 including jointing and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). With valamoid joints including sealing with sand cement morter (4:1) 150 mm dia.
100 mm dia.
75 mm dia.
Supplying, fitting & fixing H.C.I. bend with door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). With valamoid joints including sealing with sand cement morter (4:1) 150 mm dia.
100 mm dia.
75 mm dia.
Supplying, fitting & fixing H.C.I. bend without door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). With valamoid joints including sealing with sand cement morter (4:1) 150 mm dia.
100 mm dia.
75 mm dia.
Supplying, fitting & fixing H.C.I. offset conforming to I.S.S. including jointing complete with or without ear (75 mm projection) and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). With valamoid joints including sealing with sand cement morter (4:1 150 mm dia.
100 mm dia.
75 mm dia.
H.C.I. bell mouth plain trap supplied, fitted and fixed with valamoid joint complete 100 mm dia and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately.
Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). With valamoid joints including sealing with sand cement morter (4:1) 100 mm dia.
75 mm dia.
Supplying, fitting and fixing cast iron extension pipes for using in Traps only (connector) conforming to I.S.3989/1970 and 1729/1964 including lead caulked joints complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). 100 mm X 450 mm
100 mm X 600 mm
Extension 50 mm one way 100 mm X 375 mm
Extension 50 mm two way 100 mm X 375 mm
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. Coloured E.W.C. Burgandy, Emeral Green coloured With 'P' trap
Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. Coloured Anglo India W.C. Burgandy, Emeral Green coloured With 'P' trap (with vent)
Suppling, fitting and fixing Wall mounted water closet of white glazed vitreous chinaware of approved make and brand in position complete with necessary nut and boalts (Equivalent to Code No. 20061 or 92065 & Model Studio or Rubbic of Hidware or equivalent.) Coloured Wall mounted W.C. Burgandy, Emeral Green coloured
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. Coloured Urinal Burgandy, Emeral Green coloured 635 mm X 395 mm X 420 mm
Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). Coloured Squating plate Burgandy, Emeral Green coloured 450 mm X 350 mm
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete E.W.C. Bestolite (solid type) white
Anglo Indian Plastic (hallow type) white
Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets. Plain edge sink with overflow 610 mm X 450 mm X 250 mm Roman brown, Fern green, Misty lilac, Orange, Sienna gold, Silver grey, Sepia, Alpine, Cornil sorvinto blue
Supplying, fitting and fixing Drain boards for sinks with brackets in position. Porcelain fluted drain board of approved make 530 mm X 450 mm
Supplying, fitting & fixing Aluminium domical grating. 150 mm
Supplying, fitting & fixing Cast Iron Fresh air inlet valve 100 mm and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (connector) conforming to I.S.3989/1970 and 1729/1964 including lead caulked joints complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately).
Supplying, fitting and fixing 18 mm thick marble partition slab with chawk doongri marbel square cut, both sides polished with two front corners rounded and edges polished.
Supplying, fitting and fixing glass shelf with aluminium guard rails. Ordinary type with 5.5 mm sheet glass 600 mm X 125 mm
Supplying, fitting and fixing liquid soap container. Cromium plated.
Supplying, fitting and fixing soap holder PTMT(Prayag or equivalent)
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm.
Supplying, fitting and fixing towel rail with two brackets. C.P. over brass 25 mm dia. and 750 mm long
Supplying, fitting and fixing porcelain toilet paper holder of approved make with wooden spindle as necessary. Recess roll type size 150 mm X 150 mm
Supplying, fitting and fixing porcelain soap tray of approved make. Recessed soap tray of size 150 mm X 150 mm
Supplying, fitting and fixing bathroom shelf of approved make of size 580 mm X 150 mm (porcelain). Burgandy, Emerald green
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Bazree (N.B Variety) SAIL/TATA/RINL
Extra for each additional depth of 150 mm or part thereof beyond initial 600mm depth.
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only).(iii) 1050 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 225 mm dia. of approved makeii) With Bazree (N.B Varity) SAIL/TATA/RINL.
Construction of septic tank of different capacities as per approved drawing of PWD SOR with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For 30 users With Bazree (N.B Varity) SAIL/TATA/RINL.
For 50 users With Bazree (N.B Varity) SAIL/TATA/RINL
For 100 users With Bazree (N.B Varity) SAIL/TATA/RINL
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well ncluding shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. JSW/JSPL/SHYAM/BMASL/SRMB/ECECTROSTEEL/SSL.
Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.
Cement washing including cleaning and smoothening surface thoroughly (cement to be used @15 kg./100 sq.m. of surface for one coat and @25 kg./100 sq.m of surface for two coats): External surface (Ground floor) One coat
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. Two coats. In 1st floor
SECTION (B) : CHIEF JUSTICE BUNGALOW Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS- 6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work) With carried earth arranged by the contractor within a radius of 3 km. but not exceeding 5km including cost of carried earth.
Anti-termite treatment to the junction of wood work and masonry walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight including spraying at the points of contact with the adjoining masonry by drilling 6m. dia holes at a downward angle of about 45 degree at the junction of woodwork and masonry and squirting chemical emulsion into these holes at the rate of half litre per hole. The entire work is to be carried out as per specification of Code I.S.-6313 (Part-III)-1981. The shutters are to be sprayed with emulsion. on both sides. All wooden fixtures like almirahs, racks etc. are also to be throughly sprayed with chemical emulsion. (Payment will be made on the basis of outside measurements of doors and windows)
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
In superstructure, ground floor
1st floor
2nd floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
1st floor
2nd floor
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
1st floor
2nd floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel SAIL/ TATA/RINL For works in foundation, basement and upto roof of ground floor/upto 4 m
1st floor
2nd floor
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i) Shuttering without staging in foundation.
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. In ground floor
1st floor
2nd floor
Providing and fixing machine cut, mirror polished, Italian Marble stone (Imported quality, such as Perlato, Bottichino, Crema, Antique Beige, Dark Emperadore, Red Verona, Black Marquino etc.) in dado/wall laid in required pattern in linear portion of the building all complete as per architectural drawings with Italian Marble stone slab laid over 15 mm (average) thick base of cement morter 1 : 2 (1 cement : 2 coarse sand) including making suitable arrangements to hold the stones properly by brass / copper hooks applying white cement slurry @ 4.4 kg/sq.m the back site of marble and pointing with cement morter (1:2)(1 Cement : 2 Marble dust) admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge including cost of materials, labours, scaffolding, staging, curing complete. [White cement, Pigment to be supplied by the Agency]. More White with less veins. 20 mm thick Italian Marble stone slab Ground floor
1st floor
Supplying fitting and fixing Italian Marble slab/Tile in skirting (upto 300 mm ht) over 15mm (avg) thick base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/ Sq.m at back side of marble and jointed with white cement slurry @ 2.2 kg/ Sq.m with necessary pigments including grinding and Granite Polishing. [White cement and Pigment to be supplied by the Agency] White with veins 20 mm thick Italian Marble stone slab Ground Floor
1st floor
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge.(White cement, synthetic adhesive and grout material to be supplied by the contra conc With Polymerised Adhesive [6 mm thick] & epoxy grouting materials for filling joints including spacer-2 mm [Applied directly over finished artificial stone floor/ mosaic etc.] Deep Colour & White Ground Floor
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (size not Iess than 800mmX 800 mm X 10.2 mm thick) ln Ground FIoor:
1st floor-
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. Area of each Granite slab above 1.00 Square meter. Ground floor
1st floor-
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Marble Stone.
Supplying, fitting and fixing 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200 mm X 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density > 850 kg/m3 substrate core over a rasin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture (< 8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer 'T' profile etc. wherever required and preparation of base including all other incidental works as per direction & satisfaction of Engineer in charge. Cost of Laminate Floor Accessories only (Skirting ,End edge, T- moulding,Reducer) shall have to be added separately, wherever required. ln Ground FIoor :Category: Normal Footfall; Class- 23;Abrasion resistance:-AC3 Thk on Swelling:- < 18% ;Impact resistance:- IC 1
P.V.C- False Ceiling : Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat 19mmx3mm as necessary,the entire frame will be ainted with red oxide. PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entire framework will not be visible from below P.V.C Section will be fixed with the frame with the help of self tapping steel screws including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineerin- Charge .
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. 60 mm thick interlocking designer concrete paver block M- 35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) Coloured Decorative
Plain and finished timber planks in partition, shelves etc. fitted and fixed complete as per design (butt joints) in ground floor. (iv) 32mm thick planks Sishu / Champ / Badam / Gamar / Bhola / Mogra / Hallak
Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] Ground floor 19mm
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor Glossy/Matt/Suede excluding surface texture or metallic lustre. Thickness of laminate 1.5mm
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:4 cement mortar 20 mm thick plaster Ground floor
1st floor
2nd floor
10 mm thick plaster (1:4) Ground floor
1st floor
2nd floor
15 mm thick plaster (1:6) Ground floor
1st floor
2nd floor
Extra for fluted, corrugated or ribbed plaster (over rate of corresponding rate of plaster). (In 1:3 Cement:Sand)
Rendering the Surface of walls and ceiling with White Cement base wall putty of approved make & brand.(1.5 mm thick)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coats In Ground Floor:
1st floor
2nd floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Premium 100% Acrylic Emulsion (Two Coat) In Ground floor
1st floor
2nd floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coat Solvent based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) (Two coats) Luxury Quality
Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete (excluding the cost of bolts, paints, but including the cost of nails, screws etc.) (The quantum should be corrected upto three decimals) (i) Sal : Siliguri. In Ground floor
French polishing to wood work including preparing surface (ordinary gloss) On new wood work
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. 32 mm thick In ground floor.
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. 66mm x 90mm
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-incharge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Siliguri In ground floor
1st floor
2nd floor
Supplying 4 lever mortice lock or any approved make and brand as per direction of the Engineer- in -Charge. 150 mm.
Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.
Supplying Aluminium casted body hydraulic door closer as per I.S.I.
Godrej Hydraulic door closer fitted and fixed complete. Heavy type
Supplying 125 mm. Dia acrylic handle for aluminium door as per approved make & brand. Colour
Supplying heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge.
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) 40mm X 6mm, 250mm Length
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: 75 x 63 x 3.2mm.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 225mm long x 10mm dia. bolt.
Anodised aluminium grip handle with base plate of approved quality fitted and fixed complete. With base plate. 165mm grip x 12mm dia rod x 42mm plate x 3.2mm thick.
Supplying anodised aluminium catch hook with eye fitted and fixed to shutter and chowkat complete of best quality: 225mm long.
Metallic magic eye of approved quality fitted and fixed complete.
Supplying, Aluminium Grill with F channel frame of approved make and brand having ultimate tensile strength of 19 Kg/Sq.m. and modulus of elasticity 7000 kg/ sq.m., with 15 micron anodised fitted & fixed with necessary screws etc. complete as per direction of Engineer-in-charge. Grill made with 10 mm wide and 5.2 mm thick aluminium sheet having expansion width of 66.00 mm and weight not less than 3.26 Kg/Sq.m. In Ground floor
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor.
Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. In Ground floor
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of erpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete) In ground floor
Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approvedmake and brand as per direction of Engineer-in-Charge. In Ground Floor Both side decorative lamination Interior Grade 12 mm
Supplying , fitting and fixing Godrej ultra vertibold brass rim lock.
Wood work in upper rails of railing, hand rail of staircase, balcony etc. as per design & drawing approved by Engineer-in-Charge includig necessary bend, moulding fitted and fixed complete (for purpose of payment section will be measured in the square). 1st class best Indian teak. Ground floor-
1st floor
Supplying, fitting & fixing Step edging made of anodised Aluminium Alloy Extrusion (weight @ 0.494 Kg per Mtr.) Conforming to IS: 732-1983 and IS: 1285-1975, fixed to the steps by strainless steel screws driven by electric drill as per specification & direction of Engineer-in-charge.
Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design (each panel consisting of a single plank without joint and with ordinary glass of 7.4kg. Per sq.m./3mm thick) fitted with putty bed and teak wood beads and nails including fitting and fixing shutters in position but excluding the cost of glass , putty , teak bead, nails, hinges etc. and other fittings. 50 mm thick shutters with 25 mm thick panel. 1st class best Indian teak. in ground floor.
1st floor
2nd floor
Glazed shutters of doors, windows, fan light, clerestory windows etc. as per design (with ordinary glass of 7.4kg./sq.m. 3mm. Thick) fitted with putty bed and teak wood bead and nails including fitting and fixing shutter in position but excluding the cost of hinges and other fittings. cost of glass, putty, wooded beads etc.will be paid separately. 50 mm thick shutters 1st class best Indian teak. In ground floor.
1st floor
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. vi) 6mm thick coloured / tinted / smoke glass.
Providing and fixing of factory made uPVC Sliding window (White Colour) complete, (U value=1.9-1.3 W/m 2 K, flame resistant, self extinguishing, lead free) comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (±0.2 mm) duly reinforced with G.I. section 1.6 mm (±0.2 mm), wherever required. All corners of frame and sash will be fusion welded. After placing 5 mm Clear Annealed glass in the sash, uPVC glazing bead, interlock, EPDM gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window frame will be fixed to the wall with 100mm long and 8mm dia. Fasteners and after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per as per approved drawing & direction of Engineer-In-Charge. (Note: Profile manufacturer & Window Manufacturer must be one & same, Only manufacturer Waranty is aceptable) 3 Track 3 Sash window frame of size 122 x 54 mm & Sash of size 64 x 47 mm both having wall thickness of 2.3 ± 0.2 mm
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 10 mm thick coloured / tinted / smoke glass.
Labour charge for fabrication and installation of structural Glazing/Curtain Wall made from annodized extruded allooy aluminium sections for the following units:- Structural Glazing made of extruded and annodized alloy aluminium sections, fabrications including cutting to proper shape and size, drilling including cost of brackets, fastener bolt, mullion bolt, nuts & washers, maskin tape, double side adhesieve crosslink foam (used for guard of glazed silicon on sub-frame), tissue paper foam (used as filler between sub-frame and under backing of weather silicon), screws and other necessary hardwares, fixing of glass as per drawing, specification and direction of Engineer-in-Charge. (The rate includes hire charges of all tools and plants, including all incidental charges, adhesieve, joiners such as screw,cleate angle,etc. but excluded the cost of extruded aluminium sections, glass, glazed silicon, weather silicon etc.) In ground floor.
Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white (unit wt of to Top & side frame @1.366 kg/m ; top rail @ 1.296 kg/m; bottom rail @ 1.974 kg/m; lock rail @ 1.590 kg/m; door vertical @ 1.412 kg/m; glazing clip @ 0.167 kg/m. )
Supplying, fitting & fixing 1.5mm thick Trapezoidal profile corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer-in-charge including materials, labour, taxes and all other incidental charges (Payment to be made on area of finished work). In Roof
Supplying, fitting and fixing Godrej Multi Lock or equivallent .
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Bazree (N.B Varity). SAIL/TATA/RINL.
Construction of septic tank of different capacities as per approved drawing of PWD SOR with 1st class brick work in cement mortar (1:4) including two560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4:1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For 20 users SAIL/TATA/RINL. With Bazree(N.B Varity)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. SAIL/TATA/RINL.
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. For Concealed Work (i) CPVC Pipes Class-1, SDR-11 15 mm
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes 50 mm
Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). 100 mm
Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No. S10221114-P Trap (CRUSE SET) of CERA or equivalent.)
Supplying, fitting and fixing shower of approved brand and make. Chromium plated Rose shower with revolving joint and 150 mm longshower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand).
Chromium plated Hand shower with Flexible Tube & fittings (Equivalent to Code No. Hsh-1937 & (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar).).
Supplying, fitting and fixing bib cock or stop cock. Supplying, fitting and fixing of Chromium plated Turn type single lever concealed Diverter with lever, tip ton knob and flange of approved brand and make. Concealed Part:- (Model Code No. F4010105 of CERA or equivalent)
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 630 mm X 450 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 UPVC fittings 125/110 S Trap with W.C. Ring 75 mm
UPVC pipes Single Socketed 3 Meter Length 110 mm
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 25 mm dia
Supplying, fitting and fixing concealed cistern of approved make with flash plate Cute/Loop/Shell/Nova (Code No. concealo-H(80mm Body sap code 508179 of Hindware or equivalent). Matt/Gloss
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2000 litre capacity
Labour for hoisting plastic water storage tank. Above 1500 litre upto 5000 litre capacity. Extra for each additional story. At the roof of 1st floor from ground level
Supplying, fitting and fixing of Fire clay Kitchen Sink with overflow conforming to IS: 771 with waste fittings and C.I. Brackets.(White Colour) 750 mm X 450 m X 250 mm
Supplying, fitting and fixing towel rail with two brackets. C.P. over brass 25 mm dia. and 600 mm long
Supplying, fitting and fixing porcelain toilet paper holder of approved make with wooden spindle as necessary. Recess roll type size 150 mm X 150 mm
Supplying, fitting and fixing bathroom shelf of approved make of size 580 mm X 150 mm (porcelain).
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting & fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineerin- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge. [At Ground Floor] Mural aligned/ CAD Design Type
SECTION (C) : JUSTICE BUNGALOW Pre-construction Anti-termite measures Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS- 6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km including cost of carried earth.
Anti-termite treatment to the junction of wood work and masonry walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight including spraying at the points of contact with the adjoining masonry by drilling 6m. dia holes at a downward angle of about 45 degree at the junction of woodwork and masonry and squirting chemical emulsion into these holes at the rate of half litre per hole. The entire work is to be carried out as per specification of Code I.S.-6313 (Part-III)-1981. The shutters are to be sprayed with emulsion. on both sides. All wooden fixtures like almirahs, racks etc. are also to be throughly sprayed with chemical emulsion. (Payment will be made on the basis of outside measurements of doors and windows)
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety Ground floor
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
In superstructure, ground floor
1st floor
2nd floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
1st floor
2nd floor
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
1st floor
2nd floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel SAIL/ TATA/RINL For works in foundation, basement and upto roof of ground floor/upto 4 m
1st floor
2nd floor
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i) Shuttering without staging in foundation.
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. In ground floor
1st floor
2nd floor
Providing and fixing machine cut, mirror polished, Italian Marble stone (Imported quality, such as Perlato, Bottichino, Crema, Antique Beige, Dark Emperadore, Red Verona, Black Marquino etc.) in dado/wall laid in required pattern in linear portion of the building all complete as per architectural drawings with Italian Marble stone slab laid over 15 mm (average) thick base of cement morter 1 : 2 (1 cement : 2 coarse sand) including making suitable arrangements to hold the stones properly by brass / copper hooks applying white cement slurry @ 4.4 kg/sq.m the back site of marble and pointing with cement morter (1:2)(1 Cement : 2 Marble dust) admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge including cost of materials, labours, scaffolding, staging, curing complete. [White cement, Pigment to be supplied by the Agency]. [This work should not be executed without specific permission of Superintending Engineer] More White with less veins. 20 mm thick Italian Marble stone slab Ground floor
1st floor
Supplying fitting and fixing Italian Marble slab/Tile in skirting (upto 300 mm ht) over 15mm (avg) thick base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/ Sq.m at back side of marble and jointed with white cement slurry @ 2.2 kg/ Sq.m with necessary pigments including grinding and Granite Polishing. [White cement and Pigment to be supplied by the Agency] [This work should not be executed without specific permission of Superintending Engineer] White with veins 20 mm thick Italian Marble stone slab Ground Floor
1st floor
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge.(White cement, synthetic adhesive and grout material to be supplied by the contra conc With Polymerised Adhesive [6 mm thick] & epoxy grouting materials for filling joints including spacer-2 mm [Applied directly over finished artificial stone floor/ mosaic etc.] Deep Colour & White
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) ln Ground FIoor: (size not Iess than 800mmX 800 mm X 10.2 mm thick)
1st floor-
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. Area of each Granite slab above 1.00 Square meter. Ground floor
1st floor-
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Marble Stone.
Supplying, fitting and fixing 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200 mm X 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density > 850 kg/m3 substrate core over a rasin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture (< 8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer 'T' profile etc. wherever required and preparation of base including all other incidental works as per direction & satisfaction of Engineer in charge. Cost of Laminate Floor Accessories only (Skirting ,End edge, T- moulding,Reducer) shall have to be added separately, wherever required. (This work should not be executed without specific permission of Superintending Engineer). ln Ground FIoor :Category: Normal Footfall; Class- 23;Abrasion resistance:-AC3 Thk on Swelling:- < 18% ;Impact resistance:- IC 1
P.V.C- False Ceiling : Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat 19mmx3mm as necessary,the entire frame will be ainted with red oxide. PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entire framework will not be visible from below P.V.C Section will be fixed with the frame with the help of self tapping steel screws including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineerin- Charge .
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. 60 mm thick interlocking designer concrete paver block M- 35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) Coloured Decorative
Plain and finished timber planks in partition, shelves etc. fitted and fixed complete as per design (butt joints) in ground floor. 32mm thick planks Sishu / Champ / Badam / Gamar / Bhola / Mogra / Hallak
Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] Ground floor 19mm
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor Glossy/Matt/Suede excluding surface texture or metallic lustre. Thickness of laminate 1.5mm
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:4 cement mortar 20 mm thick plaster Ground floor
1st floor
2nd floor
10 mm thick plaster (1:4) Ground floor
1st floor
2nd floor
15 mm thick plaster (1:6) Ground floor
1st floor
2nd floor
Rendering the Surface of walls and ceiling with White Cement base wall putty of approved make & brand.(1.5 mm thick)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coats In Ground Floor:
1st floor
2nd floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Premium 100% Acrylic Emulsion (Two Coat) In Ground floor
1st floor
2nd floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coat Solvent based interior grade Acrylic Primer (In Ground Floor)
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) (Two coats) Luxury Quality
Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete (excluding the cost of bolts, paints, but including the cost of nails, screws etc.) (The quantum should be corrected upto three decimals) (i) Sal : Siliguri. In Ground floor
French polishing to wood work including preparing surface (ordinary gloss) On new wood work
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. 32 mm thick In ground floor.
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. 66mm x 90mm
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-incharge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Siliguri In ground floor
1st floor
2nd floor
Supplying 4 lever mortice lock or any approved make and brand as per direction of the Engineer- in -Charge. 150 mm.
Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.
Supplying Aluminium casted body hydraulic door closer as per I.S.I.
Godrej Hydraulic door closer fitted and fixed complete. Heavy type
Supplying 125 mm. Dia acrylic handle for aluminium door as per approved make & brand. Colour
Supplying heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge.
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) 40mm X 6mm, 250mm Length
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: 75 x 63 x 3.2mm.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 225mm long x 10mm dia. bolt.
Anodised aluminium grip handle with base plate of approved quality fitted and fixed complete. With base plate. 165mm grip x 12mm dia rod x 42mm plate x 3.2mm thick.
Supplying anodised aluminium catch hook with eye fitted and fixed to shutter and chowkat complete of best quality: 225mm long.
Metallic magic eye of approved quality fitted and fixed complete.
Supplying, Aluminium Grill with F channel frame of approved make and brand having ultimate tensile strength of 19 Kg/Sq.m. and modulus of elasticity 7000 kg/ sq.m., with 15 micron anodised fitted & fixed with necessary screws etc. complete as per direction of Engineer-in-charge. Grill made with 10 mm wide and 5.2 mm thick aluminium sheet having expansion width of 66.00 mm and weight not less than 3.26 Kg/Sq.m.
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor.
Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. In Ground floor
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of erpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete) In ground floor
Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approvedmake and brand as per direction of Engineer-in-Charge. In Ground Floor Both side decorative lamination Interior Grade 12 mm
Supplying , fitting and fixing Godrej ultra vertibold brass rim lock.
Wood work in upper rails of railing, hand rail of staircase, balcony etc. as per design & drawing approved by Engineer-in-Charge includig necessary bend, moulding fitted and fixed complete (for purpose of payment section will be measured in the square). 1st class best Indian teak. Ground floor-
1st floor
Supplying, fitting & fixing Step edging made of anodised Aluminium Alloy Extrusion (weight @ 0.494 Kg per Mtr.) Conforming to IS: 732-1983 and IS: 1285-1975, fixed to the steps by strainless steel screws driven by electric drill as per specification & direction of Engineer-in-charge.
Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design (each panel consisting of a single plank without joint and with ordinary glass of 7.4kg. Per sq.m./3mm thick) fitted with putty bed and teak wood beads and nails including fitting and fixing shutters in position but excluding the cost of glass , putty , teak bead, nails, hinges etc. and other fittings. 50 mm thick shutters with 25 mm thick panel. 1st class best Indian teak. in ground floor.
1st floor
2nd floor
Glazed shutters of doors, windows, fan light, clerestory windows etc. as per design (with ordinary glass of 7.4kg./sq.m. 3mm. Thick) fitted with putty bed and teak wood bead and nails including fitting and fixing shutter in position but excluding the cost of hinges and other fittings. cost of glass, putty, wooded beads etc.will be paid separately. 50 mm thick shutters 1st class best Indian teak. In ground floor.
1st floor
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. vi) 6mm thick coloured / tinted / smoke glass.
Providing and fixing of factory made uPVC Sliding window (White Colour) complete, (U value=1.9-1.3 W/m 2 K, flame resistant, self extinguishing, lead free) comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (±0.2 mm) duly reinforced with G.I. section 1.6 mm (±0.2 mm), wherever required. All corners of frame and sash will be fusion welded. After placing 5 mm Clear Annealed glass in the sash, uPVC glazing bead, interlock, EPDM gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window frame will be fixed to the wall with 100mm long and 8mm dia. Fasteners and after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per as per approved drawing & direction of Engineer-In-Charge. (Note: Profile manufacturer & Window Manufacturer must be one & same, Only manufacturer Waranty is aceptable) 3 Track 3 Sash window frame of size 122 x 54 mm & Sash of size 64 x 47 mm both having wall thickness of 2.3 ± 0.2 mm
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 10 mm thick coloured / tinted / smoke glass.
Labour charge for fabrication and installation of structural Glazing/Curtain Wall made from annodized extruded allooy aluminium sections for the following units:- Structural Glazing made of extruded and annodized alloy aluminium sections, fabrications including cutting to proper shape and size, drilling including cost of brackets, fastener bolt, mullion bolt, nuts & washers, maskin tape, double side adhesieve crosslink foam (used for guard of glazed silicon on sub-frame), tissue paper foam (used as filler between sub-frame and under backing of weather silicon), screws and other necessary hardwares, fixing of glass as per drawing, specification and direction of Engineer-in-Charge. (The rate includes hire charges of all tools and plants, including all incidental charges, adhesieve, joiners such as screw,cleate angle,etc. but excluded the cost of extruded aluminium sections, glass, glazed silicon, weather silicon etc.)
Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white
Supplying, fitting & fixing 1.5mm thick Trapezoidal profile corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer-in-charge including materials, labour, taxes and all other incidental charges (Payment to be made on area of finished work). In Roof
Supplying, fitting and fixing Godrej Multi Lock or equivallent .
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Bazree (N.B Varity). SAIL/TATA/RINL.
Construction of septic tank of different capacities as per approved drawing of PWD SOR with 1st class brick work in cement mortar (1:4) including two560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4:1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For 20 users SAIL/TATA/RINL. With Bazree(N.B Varity)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. SAIL/TATA/RINL.
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. For Concealed Work CPVC pipes class-I, SDR-11 15 mm
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes 50 mm
Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). 110 mm
Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No. S10221114-P Trap (CRUSE SET) of CERA or equivalent.)
Supplying, fitting and fixing shower of approved brand and make. Chromium plated Rose shower with revolving joint and 150 mm longshower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand).
Chromium plated Hand shower with Flexible Tube & fittings (Equivalent to Code No. Hsh-1937 & (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar).).
Supplying, fitting and fixing bib cock or stop cock. Supplying, fitting and fixing of Chromium plated Turn type single lever concealed Diverter with lever, tip ton knob and flange of approved brand and make. Concealed Part:- (Model Code No. F4010105 of CERA or equivalent)
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 630 mm X 450 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 UPVS fitting 125/110 S Trap with W.C. Ring 75 mm
UPVC pipes Single Socketed 3 Meter Length 110 mm
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).
Supplying, fitting and fixing concealed cistern of approved make with flash plate Cute/Loop/Shell/Nova (Code No. concealo-H(80mm Body sap code 508179 of Hindware or equivalent). Matt/Gloss
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2000 litre capacity
Labour for hoisting plastic water storage tank. Above 1500 litre upto 5000 litre capacity. Extra for each additional story At the roof of 1st floor from ground floor
Supplying, fitting and fixing of Fire clay Kitchen Sink with overflow conforming to IS: 771 with waste fittings and C.I. Brackets.(White Colour) 750 mm X 450 m X 250 mm
Supplying, fitting and fixing towel rail with two brackets. C.P. over brass 25 mm dia. and 600 mm long
Supplying, fitting and fixing porcelain toilet paper holder of approved make with wooden spindle as necessary. Recess roll type size 150 mm X 150 mm
Supplying, fitting and fixing bathroom shelf of approved make of size 580 mm X 150 mm (porcelain).
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting & fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineerin- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge. [At Ground Floor] Mural aligned/ CAD Design Type
SECTION (D) : TYPE-III QTR. Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation.
Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, as per relevant IS codes. Pakur Variety In ground floor
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel/ Mild Steel SAIL/ TATA/RINL For works in foundation and upto roof of ground floor/upto 4 m
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
Hire and labour charges for shuttering with centering and without staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works . Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work In ground floor)
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. In ground floor
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
In superstructure, Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's pecification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
In First Floor
In Second Floor
In Third Floor
Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stoneslab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture ofpigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-chargeincluding cost of materials, labour, scaffolding, staging,curing complete. In ground floor
In First Floor
In Second Floor
In Third Floor
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone.
Supplying, fitting & fixing best quality digital printed Ceramic tiles in coloured decorative on walls and floors to match with the existing work & 4 nos. key stones (10mm) fixed with adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge. In ground floor
In First Floor
In Second Floor
In Third Floor
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In Ground Floor Area of each Granite slab above 1.00 Square meter.
In First Floor
In Second Floor
In Third Floor
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges omplete as per direction of Engineerin- Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick)
In First Floor
In Second Floor
In Third Floor
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as perdirection of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana Area of each Slab/tile exceeding 0.3 sq.m. but not exceeding 0.6 sq.m.
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). In Ground floor Sal : Siliguri.
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings as per design & drawing approved by the E-I-C. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) 40mm thick shutters with 19mm thick panel of size 30 to 45 cm Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
35 mm thick factory made Solid panel PVC Door shutter made out of single piece extruded solid PVC profiles, 5 mm (± 0.2mm) thick, having styles & rails (except lock rail) of size 95 mm x 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitred cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5mm thick solid PVC Lock rail of size 115 mm x 35 mm x 35 mm, out of which 95 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 8 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in-charge. Factory made Single piece extruded PVC laker coated tapered profile door shutter of both side laminated wood grains decorative Finish
Supplying, fitting & fixing factory made foam PVC (density shall not be less than 600 kg/cum) door frame (finished weight of 2.73 kg/mtr.) of size 100mm X 45mm made off with 5mm thick extruded foam PVC sheet, mitre cut at junction of horizontal and vertical member and joined them by heat welding. Entire door frame profiles to be reinforced with steel primer coated 19 SWG 40mm X 20mm M.S. tube. An additional 5mm thick PVC sheet with desired colour/shade to be provided at the exposed surface and three nos 5mm thick PVC sheet to be provided as gap insert. The door frame to be fixed with wall by using 8mm dia. and 100mm long strainless steel screws and PVC fasteners. A minimum of 4 nos. screws to be provided for each vertical member & 2 nos. for horizontal member all complete as per direction of Engineer-in-Charge. Pre-laminated Colour
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. 40mm X 6mm, 200mm Length
Oxidised Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (viii) 100mm. X 75mm. X 3.50mm.
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixedg. 300mm x 19mm dia. bolt.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:( 300mm long x 10mm dia. bolt.
Door stopper.(Brass)
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: With continuous plate base (Hexagonal/ Round rod) 150 mm grip x 12 mm dia rod.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar 20 mm thick plaster
With 1:4 cement mortar 20 mm thick plaster, In First Floor
With 1:4 cement mortar 20 mm thick plaster, In Second Floor
With 1:4 cement mortar 20 mm thick plaster, In Third Floor
With 1:4 cement mortar 20 mm thick plaster, In Fourth Floor
With 1:4 cement mortar 15 mm thick plaster In Ground Floor
With 1:4 cement mortar 15 mm thick plaster, In First Floor
With 1:4 cement mortar 15 mm thick plaster In Second Floor
With 1:4 cement mortar 15 mm thick plaster In Third Floor
With 1:4 cement mortar 15 mm thick plaster In Fourth Floor
With 1:4 cement mortar 10 mm thick plaster, In Ground Floor
With 1:4 cement mortar 10 mm thick plaster, In First Floor
With 1:4 cement mortar 10 mm thick plaster In Second Floor
With 1:4 cement mortar 10 mm thick plaster, In Third Floor
With 1:4 cement mortar 10 mm thick plaster, In Fourth Floor
Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Agency]
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)(a) One Coat Water based interior grade Acrylic Primer
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick), Ground Floor
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One Coat In Ground Floor:
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
Protective and Decorative Textured exterior high class matt finish paint of approved quality,composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Two Coat In Ground floor
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; clear, toughened glass conforming to IS: 2553-1992 (part-II) 8 mm thick
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. in ground floor.
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Priming one coat on timber or plasteredsurface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On timber or plastered surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
On steel or other metal surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
Supplying, fitting & fixing UPVC pipes AType and fittings conforming to IS:13592- 1992 with all ecessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing aterails (Spun Yarn, Valamoid/ Bitumen/ M-Seal etc) complete. UPVC Pipes: 160 mm. Dia.
UPVC Fittings: Plain Tee 160mm Dia
UPVC Fittings: Bend 87.5 degree 160 mm. Dia.
UPVC Fittings: Shoe 160 mm. Dia.
Supplying& laying 20 mm designer chequered tiles of any shade and of approved quality as per IS: 1237: 1980 laid in patterns as directed in pavement, footpath including necessary underlay 25 mm thick average cement mortar (1:3) complete in all respect with all labour and materials [using cement slurry @ 4.4 kg/Sq.m at back side of tiles. Cement of mortar & slurry will be supplied by the Department. Border concrete if necessary to be paid separately].
Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse)
Supplying, fitting and fixing Fan Hook for ceiling with 1 metre long 16mm. dia rod complete including mending damages. Payment for damage and repair to be made separately.
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2000 ltr. Capacity
Labour for hoisting plastic water storage tank. Above 1500 litre and upto 5000 litre capacity. At the roof of 3rd floor from Ground level
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conformingto IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. For Exposed Work (i) CPVC Pipes Class-1, SDR-11 Dia 20 mm
SDR-11 , Dia 25 mm
SDR-11 , Dia 50 mm
For Concealed Work CPVC Pipes Class-1,SDR-11, 20 mm
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 50 mm dia
25 mm dia
20 mm dia
Supplying, fitting and fixing bib cock or stop cock. pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm. - 15 mm
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets Sink only 630 mm X 550 mm X 180 mm
Supplying, fitting and fixing pedestal of approved make for wash basin.WHITE
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. 450 mm long
Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc With "P" trap - White
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). Anglo Indian Plastic (hallow type) white
Supplying, fitting & fixing Cast Iron Fresh air inlet valve 100 mm and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (connector) conforming to I.S.3989/1970 and 1729/1964 including lead caulked joints complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately).
Supplying, fitting and fixing liquid soap container. Cromium plated.
Fibre glass
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting and fixing towel rail with two brackets. C.P. over brass 25 mm dia. And 600 mm long
Supplying, fitting and fixing shower of approved brand and make. Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing glass shelf with aluminium guard rails. Ordinary type with 5.5 mm sheet glass 600 mm X 125 mm
Supplying, fitting and fixing C.I. round grating. 150 mm
H.C.I. bell mouth plain trap supplied, fitted and fixed with valamoid joint complete 100 mm dia and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) Single Socketed 3 Meter Length 75 mm
Plain Tee 75 mm
Door Tee 75 mm
Bend 87.5º 75 mm
Coupler 75 mm
Cross Tee 75 mm
Vent Cowl 75 mm
Pipeclip 75 mm
Reducer 110 X 75 mm 75 mm
Door Bend (T.S.) 75 mm
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. Above ground 75 mm
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Bazree (N. B. varity) & using of SAIL / TATA / RINL
Construction of septic tank of different capacities as per approved drawing of PWD SOR with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For 50 users SAIL/TATA/RINL
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well ncluding shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. With Bazree (N. B. varity) & using of SAIL / TATA / RINL
SECTION (E) : TYPE-IV QTR. Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work. With earth obtained from excavation of foundation.
Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Filling in foundation or plinth by SIVER SAND in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur variety IN GROUND FLOOR
IN FIRST FLOOR
IN SECOND FLOOR
IN THIRD FLOOR
IN FORTH FLOOR
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
IN FIRST FLOOR
IN SECOND FLOOR
IN THIRD FLOOR
IN FORTH FLOOR
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation, basement and upto roof of gr. floor/upto 4m Tor Steel / Mild Steel. SAIL / TATA / RINL GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FORTH FLOOR
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. IN GROUND FLOOR including Foundation
IN FIRST FLOOR
IN SECOND FLOOR
IN THIRD FLOOR
IN FORTH FLOOR
25 mm to 30 mm shuttering without staging in foundation.
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
In superstructure, GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FORTH FLOOR
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) In GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FORTH FLOOR
75 mm. thick brick work with 1st class bricks set in cement, sand mortar (1:4) in ground floor including H.B. netting in every alternate layers. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. 3 mm thick topping. (High polishing grinding on this item is not permitted with ordinary cement). 35 mm thck (As per drawing) / Using Grey cement GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FORTH FLOOR
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. F l o o r With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. Area of each tile upto 0.09 Sq.m Coloured decorative GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. Area of each tile above 0.09 Sq.m / Coloured decorative GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in Charge. (b) Slab Thickness above 25 mm and upto 37.5 mm in Ground Floor.
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). SAL: SILIGURI GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FORTH FLOOR
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] @ Rs. 1,896.00/m2. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FORTH FLOOR
Two point nose steel handle including fitting and fixing. (150mm)
steel peg stay 300 mm long including fitting and fixing.
M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FORTH FLOOR
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings as per design & drawing approved by the E-I-C. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be mad) 35mm thick shutters with 19mm thick panel of size 30to 45 Cm. Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FORTH FLOOR
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. 32 mm thick In ground floor
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. 66mm x 70mm
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. 40mm X 6mm, 250mm Length
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 75mm. X 3.50mm.
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixedg. 300mm x 16mm dia. bolt.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated. 200mm long x 10mm dia. bolt.
300mm long x 10mm dia. bolt.
Door stopper (Anodised aluminium)
Supplying fitting and fixing door made with IRC febric mesh of 75mm x 50mmx4.5mmx2.7mm on 50mm x 50mm x 6mm angle iron frames all round and one 37.5mm x 6mm M.S. flat bar over the netting all round welded to angle iron frame and providing locking arrangements if necessary and with two coats of synthetic enamel paint(Other than Hi-gloss) fitted and fixed with clamps or haskal doomney etc. complete including flat stiffeners on every 1.0
Anodised aliminium D-type handle of approved quality manu- factured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete. With continuous plate base (Hexagonal / Round rod) 125 mm grip x 10 mm dia rod.
Labour for Chipping of concrete surface before taking up Plastering work. Area same as Shuttering area
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/ staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortarb) 20mm thick plaster GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
With 1:4 cement mortar 15 mm thick plaster(External surface) GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
10 mm thick plaster GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC One Coat GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Two Coat Premium 100% Acrylic Emulsion GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats Internal surface (All floors) Two coats (on new works only).
Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On timber or plastered surface : Two coats (with any shade except white)
On steel or other metal surface : Two coats (with any shade except white)
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Supplying best Indian sheet glass panes set in putty (as per I.S specification) and fitted and fixed with teak wood beads and nails complete. (In all floors for internal wall & upto 6 m height for external wall) 3 mm thick (weighing 7.4 kg/Sq.m)
Supplying, fitting & fixing UPVC pipes A-Type and fittings conforming to IS:13592- 1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/ Bitumen/ M-Seal etc) complete. UPVC Pipes: 160 mm. Dia.
UPVC Fittings: Plain Tee 160 mm. Dia.
Bend 87.5 degree 160 mm. Dia.
Shoe 160 mm. Dia.
Supplying& laying 20 mm designer chequered tiles of any shade and of approved quality as per IS: 1237: 1980 laid in patterns as directed in pavement, footpath including necessary underlay 25 mm thick average cement mortar (1:3) complete in all respect with all labour and materials [using cement slurry @ 4.4 kg/Sq.m at back side of tiles. Cement of mortar & slurry will be supplied by the Agency. Border concrete if necessary to be paid separately].
Providing waterproofing treatment over concrete roof surface (old or new) by the application of two coats of slurry prepared with latex of approved brand, water and cement in the proportion of (LP.W. Cement - 1:4:6) by volume, with brush in a time gap of minimum 4(four) hours to 14(fourteen) hours between the two layers, laying 20mm thick and sand and cement consolidated plaster (1:4) admixed with Plastocrete Super of approved brand 0.2% by weight of cement, laying flat 1st class Brick Bats / Bricks over the mortar keeping a gap of 10-20 mm between two bats, filling the vertical joints with the aforesaid mortar, providing a second layer of 20 mm thick sand and cement plaster (1:4) admixed with Plastocrete Super as above over the brick layer, the top surface of the treatment should be chequered to provide the antistrip property. By Bricks (cement 25.66 kg/ Sq.m)
Supplying, fitting and fixing Fan Hook for ceiling with 1 metre long 16mm. dia rod complete including mending damages. Payment for damage and repair to be made separately.
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2000 litre capacity
Labour for hoisting plastic water storage tank. Above 1500 litre and upto 5000 litre capacity. At the roof of 3rd floor from G.L.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. For Exposed Work CPVC Pipes Class-I,SDR-11 20 mm dia.
50 mm dia.
For Concealed Work CPVC Pipes Class-I,SDR-11 20 mm dia
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 50 mm dia
20 mm dia
Supplying, fitting and fixing bib cock or stop cock. pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm. - 15 mm
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. Sink only 630 mm X 550 mm X 180 mm
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia 450 long.
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. With "P" trap - White
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). E.W.C. Bestolite (solid type) white
Supplying, fitting & fixing Cast Iron Fresh air inlet valve 100 mm and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (connector) conforming to I.S.3989/1970 and 1729/1964 including lead caulked joints complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately).
Supplying, fitting and fixing liquid soap container. Cromium plated.
Supplying, fitting and fixing soap holder. Fibre glass
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting and fixing towel rail with two brackets.(a) C.P Overbrass C.P. over brass 25 mm dia. And 600 mm long
Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing glass shelf with aluminium guard rails. Ordinary type with 5.5 mm sheet glass 600 mm X 125 mm
Supplying, fitting and fixing C.I. round grating. 150 mm
H.C.I. bell mouth plain trap supplied, fitted and fixed with valamoid joint complete 100 mm dia and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately
Supply of UPVC pipes Type) & fittings conforming to IS-13592-1992 Single Socketed 3 Meter Length 75 mm
Plain Tee (a) 75 mm
Door Tee (a) 75 mm
Bend 87.5º (a) 75 mm
Coupler (a) 75 mm
Cross Tee (a) 75 mm
Vent Cowl (a) 75 mm
Pipe Clip (a) 75 mm
Reducer 110 X 75 mm (a) 75 mm
Door Bend (T.S.) (a) 75 mm
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. Above ground 75 mm
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Bazree (N.B Varity). SAIL/TATA/RINL.
Construction of septic tank of different capacities as per approved drawing of PWD SOR with 1st class brick work in cement mortar (1:4) including two560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4:1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For 50 users SAIL/TATA/RINL. With Bazree(N.B Varity)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. SAIL/TATA/RINL.
SECTION (F) : AUDITORIUM Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplying and laying Polythene Sheet (150gm/sq.m.) over damp proof course or below flooring or roof terracing or in foundation trenches.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety Ground floor
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
1st floor
2nd floor
3rd floor
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i) Shuttering without staging in foundation.
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. In ground floor
1st floor
2nd floor
3 rd floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel/Mild Steel SAIL/ TATA/RINL For works in foundation, basement and upto roof of ground floor/upto 4 m
1st floor
2nd floor
3 rd floor
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Anti-termite treatment to the junction of wood work and masonry walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight including spraying at the points of contact with the adjoining masonry by drilling 6m. dia holes at a downward angle of about 45 degree at the junction of woodwork and masonry and squirting chemical emulsion into these holes at the rate of half litre per hole. The entire work is to be carried out as per specification of Code I.S.-6313 (Part-III)-1981. The shutters are to be sprayed with emulsion. on both sides. All wooden fixtures like almirahs, racks etc. are also to be throughly sprayed with chemical emulsion. (Payment will be made on the basis of outside measurements of doors and windows)
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
1st floor
2nd floor
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
In superstructure, ground floor
1st floor
2nd floor
3 rd floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:4 cement mortar 20 mm thick plaster Ground floor
1st floor
2nd floor
3 rd floor
10 mm thick plaster (1:4) Ground floor
1st floor
2nd floor
15 mm thick plaster (1:4) Ground floor
1st floor
2nd floor
3 rd floor
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Siliguri In ground floor
1st floor
2nd floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) 40mm X 6mm, 200mm Length
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark 100mm. X 50mm. X 1.25mm
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. 250mm x 19mm dia. bolt.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 200mm long x 10mm dia. bolt.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: With continuous plate base (Hexagonal/ Round rod) 125 mm grip x 10 mm dia rod.
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings as per design & drawing approved by the E-I-C. 50 mm thick shutters with 25 mm thick panel of size 30 to 45 cm 1st class best Indian teak. in ground floor.
Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.
Godrej Hydraulic door closer fitted and fixed complete. Medium type
Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formal dehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: 35mm thick shutters (single leaf)
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. in ground floor.
Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. Span beyond 20 Mtr and up to 30 Mtr
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. For Structural Works in Roof Trusses etc. using joists, channels and angles of specified section weighing less than 22.5 kg/ m
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement 25 mm. thick In ground floor.
1 st floor-
Dressed wood work in post , plate , battens . etc. fitted & fixed complete (excluding the cost of bolts only, but including the cost of nails, screws etc.) (The quantum should be corrected upto three decimals) Sal : Siliguri. In ground floor
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). In Roof With 0.5 mm thick sheet
Aluminium sheet ridging fitted with self tapping screws, EPDM washers etc complete.(Minimum 225mm end lapping). 300 mm lapping each way With 0.71 mm sheet
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns,wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m]Area of each Granite slab above 1.00 Square meter. Ground floor
3 rd floor
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) ln Ground FIoor:(size not Iess than 800mmX 800 mm X 10.2 mm thick)
1st floor
2nd floor
Supplying, fitting & fixing best quality digital printed Ceramic tiles in coloured decorative on walls and floors to match with the existing work & 4 nos. key stones (10mm) fixed with adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge. Ground floor
1st floor
2nd floor
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] With Chawk Doongri Area of each Slab/tile exceeding 0.60 sq.m but not exceeding 1.00 sq.m. Ground floor
1st floor
2nd floor
Rough dressed timber planks fitted and fixed with nut bolts excluding framework complete : 50mm thick planks Sal Loca In ground floor
Supplying & laying of approved brand of scratch proof, semi flexible P.V.C. blended homogeneous marble Vinyle flooring in tiles conforming to IS:3461, fixing with synthetic acrylic adhesive after preparing the floor, levelling & smothaning when necessary with suitable putty, as per the design & instruction of the Engineer-in-charge. 2 mm thick
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr.
Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white
Supplying, Aluminium Grill with F channel frame of approved make and brand having ultimate tensile strength of 19 Kg/Sq.m. and modulus of elasticity 7000 kg/ sq.m., with 15 micron anodised fitted & fixed with necessary screws etc. complete as per direction of Engineer-in-charge.
Supplying, Fitting & fixing different factory made Metal Craft Sheet (excluding cost of metal crafting) incluing cost of powder coating (for M.S, Aluminium plate) & finished metal sheet with all fitting accessories complete in all respect as per diection of Engineer-in-Charge Aluminium Plate 2.0mm thick
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; clear, toughened glass conforming to IS: 2553-1992 (part-II) 8mm thick
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One Coat Ground floor
1 st floor
2 nd floor
3 rd floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Super Protective 100% Acrylic Emulsion. Ground floor
1 st floor
2 nd floor
3 rd floor
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Priming one coat on Steel or other Metal surface with synthetic oil bound primer of approved quality including smootheing surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On timber or plastered surface: With super gloss (hi-gloss) - Two coats (with any shade except white)
On steel or other metal surface: With super gloss (hi-gloss) - Two coats (with any shade except white)
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. 66mm x 90mm
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. 32 mm thick In ground floor.
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) 3 mm thick (weighing 7.4 kg/Sq.m)
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183, density 48 kg/m3, 50m mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh for top most ceiling of building.
Supplying and fitting in all places of wall panelling to all heights and fixing on pre- framed existing frame work grid with glass wool of 50mm thick having density of 48 Kg per cum. to be inserted into the pre - fabricated slot covered the glass wool by marking cloths treated with Naptha @ 0.07 Ltr.per Sq.m. of cloths. Finally 12.5mm thick gypsum Fulton board having size 595mmX595mm fitted & fixed into the pre-fabricated grid and covered the all perifirial gaps of fulton board by self additive fibre tape with necessary filler if required, complete in all respect as per direction of the Engineer-in-charge.
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC value > 0.65 should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. Acoustic False Ceiling (with 15mm thick OW Acoustic Board and E-Grid U- 1520) In Ground floor
Supplying fitting & fixing frames for Fire resistant door shutters made of 1st class Malaysian Hardwood (densified to 810 kg/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141 of section 120 mm X 70 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type intumescent strip of size 10 mmx 4 mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete as per direction of Engineer -inCharge including a protective coat of painting at the contact surfaces of the frame excluding cost of concrete,Iron butt hinges and M.S clamp at Ground Floor. [Note : Specific permission of the Superintending Engineer is required for execution of this item] In Ground floor
Supplying & fitting of 65mm thick asbestos free - fire, heat and smoke resistant composite Accoustic Door Shutter complying with fire performance- FD120 as per IS:3614 (part -II)-comprising of 2x 8 mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood,densified to 810kg/cum ) frame work of 100 mm x32 mm with 32mm thick infill of ceramic fiber (density 128Kgs/cum), vermaculite mix faced with 6 mm Fire retardant High Density fire board, internally lipped with hardwood beading, and pasted in Hydraulic Press under 25 MPa, spray coated with 2 coats of in-tumescent paint of minimum 200 micron, and with 1 row of Brush- Type intumescent strip of size 10mmx 4mm affixed on peripheral slit on all edges of shutter except bottom for fire and smoke sealing and placement of 3 mm thick rubber membrane, at the inside face, sandwiched between calcium silicate board & high density fire retardant board , without any external lipping including fitting ,fixing shutters in position but excluding the cost of hinges & other fittings as per direction of Engineer -in -charge complete in all respect in Ground Floor. [Note : Specific permission of the Superintending Engineer is required for execution of this item.] In Ground floor
Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors, of size EN-4 for leaf width upto 950/ 1100mm weighing maximum 60/ 80 kgs, CE certified, marked & conforming to EN 1154-2003 of approved quality of reputed brand, complete as per direction & satisfaction of Engineer-in-Charge. For leaf width upto 950mm
Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN -1154, of approved quality of reputed brand as per direction of Eingineer-in-Charge fitted and fixed complete including all incidental charges.
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 40 mm dia
25 mm dia
Supplying, fitting and fixing street pattern hydrant 65 mm with guaranteed spindles and C.I.cover complete.
Supplying, fitting and fixing bib cock or stop cock. Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Chromium plated Bib Cock with wall flange (Equivalent to Code No. 5047 & Model - Florentine of Jaquar or similar brand).
Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes 15 mm
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. 750 mm long
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No. S10221114-P Trap (CRUSE SET) of CERA or equivalent.)
Supplying, fitting and fixing 10 litre white glazed vitreous chinaware of approve low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internal fittings. (Model Code No. S1060106 of CERA or equivalent.) White
Supplying, fitting and fixing Stainless steel Wall Mounted Hinged hand rail (750X100 mm) covered by Nylon surface with contour finish (for better grip) with two brackets. (Model Code No.B2210108 of CERA or equivalent.)
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. With 'P' trap
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing). SIZE 580 mm X 440 mm
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. SIZE 635 mm X 395 mm X 420 mm
Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). SIZE 450 mm X 350 mm
Supplying, fitting and fixing liquid soap container. Cromium plated.
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting and fixing towel rail with two brackets. C.P. over brass 25 mm dia. and 750 mm long
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 Single Socketed 3 Meter Length / 110 mm
Plain Tee / 110 mm Falling
Door Tee / 110 mm
Bend 87.5 / 110 mm
Door Bend / 110 mm
Vent Cowl / 110 mm
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. E.W.C./Bestolite (solid type) white
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2000 litre capacity
Labour for hoisting plastic water storage tank. Above 1500 litre upto 5000 litre capacity. Upto 1st story from G.L.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Bazree (N.B. Variety) (SAIL/TATA/RINL)
Construction of septic tank of different capacities as per approved drawing of PWD SOR with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Upto 50 users:-With Bazree (N.B. Variety) (SAIL/TATA/RINL)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. SAIL/TATA/RINL
Supplying, fitting and fixing shower of approved brand and make. Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.
Supplying & laying interlocking designer paver block of any shade and of approved quality as per IS: 1237-1980 laid in pattern as directed in pavement, footpath, driveway, etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Coloured Decorative/ 60 mm thick block (over 150 mm medium sand bed including cost of sand but excluding cost of earthwork in excavation or dismantling of existing hard surface if necessary) Coloured Decorative
SECTION (G) : JUDGES CLUB WITH SWIMMING POOL Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as irected. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Depth of excavation exceeding 1,500 mm but not exceeding 3000 mm
Single Brick Flat Soling of picked jhama bricks including ramming and ressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
In First Floor
In Second Floor
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i) Shuttering without staging in foundation.
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. In ground floor
In First Floor
In Second Floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor/upto 4 m For works in foundation, basement and upto roof of ground floor/upto 4 m. SAIL/TATA/RINL
In First Floor
In Second Floor
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation
Earth work in filling in foundation trenches or plinth with good(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Pre-Constructional Anti-termite measures: Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
In First Floor
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
In superstructure, ground floor
first floor
second floor
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip coarse, scaffolding / staging where necessary. With 1:4 cement mortar,20 mm thick plaster, Ground Floor
First Floor
Second Floor
With 1:4 cement mortar,10 mm thick plaster, Ground Floor
First Floor
With 1:4 cement mortar,15mm thick plaster, Ground Floor
First Floor
Second Floor
Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Local. Ground Floor
In First Floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) 40mm X 6mm, 200mm Length
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 50mm. X 1.25mm.
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed . 250mm x 19mm dia. bolt.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated. 200mm long x 10mm dia. bolt.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed. 125 mm grip x 10 mm dia rod.
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings as per design & drawing approved by the E-I-C. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) 50mm thick shutters with 25mm thick panel of size 30 to 45 cm 1st class best Indian teak.
Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete.
Godrej Hydraulic door closer fitted and fixed complete. Medium type
Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: 35 mm thick shutters (single leaf)
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. in ground floor.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] Area of each Granite slab above 1.00 Square meter. in ground floor.
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. ln Ground FIoor:(size not Iess than 800mmX 800 mm X 10.2 mm thick)
In First Floor
Supplying, fitting & fixing best quality digital printed Ceramic tiles in coloured decorative on walls and floors to match with the existing work & 4 nos. key stones (10mm) fixed with adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge. Ground Floor
In First Floor
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] With Chawk Doongri/Area of each Slab/tile exceeding 0.60 sq.m but not exceeding 1.00 sq.m.
In First Floor
Supplying, Aluminium Grill with F channel frame of approved make and brand having ultimate tensile strength of 19 Kg/Sq.m. and modulus of elasticity 7000 kg/ sq.m., with 15 micron anodised fitted & fixed with necessary screws etc. complete as per direction of Engineer-in-charge.
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating)
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; clear, toughened glass conforming to IS: 2553-1992 (part-II) 8 mm
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One coat in ground floor.
First Floor
Second Floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Super Protective 100% Acrylic Emulsion. Ground Floor
In First Floor
In Second Floor
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Priming one coat on Steel or other Metal surface with synthetic oil bound primer of approved quality including smootheing surfaces by sand papering etc.
Painting with best quality Synthetic Enamel Paint of approved make and brand including smootheing surfaces by sand papering etc. including using of approved putty etc. on the surface, if necessary: On timber or plastered surface: With super gloss (hi-gloss)Two coats (with any shade except white)
On steel or other metal surface: With super gloss (hi-gloss) Two coats (with any shade except white)
Supplying, fitting and fixing fibre reinforced polymer (FRP) composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. 66mm x 90mm
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. 32 mm thick in ground floor.
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) 3 mm thick (weighing 7.4 kg/Sq.m)
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).40 mm dia
25 mm dia
Supplying, fitting and fixing bib cock or stop cock. Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Chromium plated Bib Cock with wall flange (Equivalent to Code No. 5047 & Model - Florentine of Jaquar or similar brand).
Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes 15 mm
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. 750 mm long
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No. S10221114-P Trap (CRUSE SET) of CERA or equivalent.)
Supplying, fitting and fixing 10 litre white glazed vitreous chinaware of approve low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internal fittings. (Model Code No. S1060106 of CERA or equivalent.)
Supplying, fitting and fixing Stainless steel Wall Mounted Hinged hand rail (750X100 mm) covered by Nylon surface with contour finish (for better grip) with two brackets.(Model Code No.B2210108 of CERA or equivalent.)
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing).580 mm X 440 mm
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.635 mm X 395 mm X 420 mm
Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). 450 mm X 350 mm
Supplying, fitting and fixing liquid soap container. Cromium plated.
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame ofany colour, frame size 550 mm X 400 mm
Supplying, fitting and fixing towel rail with two brackets. C.P. over brass 25 mm dia. and 750 mm long
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 Single Socketed 3 Meter Length 110 mm
Plain Tee, 110 mm
Door Tee, 110 mm
Bend 87.5, 110 mm
Door Bend, (T.S.), 110 mm
Vent Cowl, 110 mm
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. E.W.C. Bestolite (solid type) white
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2000 litre capacity
Labour for hoisting plastic water storage tank. Above 1500 litre upto 5000 litre capacity. Upto 1st story from G.L.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Bazree (N.B Variety) (SAIL/TATA/RINL)
Construction of septic tank of different capacities as per approved drawing of PWD SOR with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For 50 users With Bazree (N.B Varity) (SAIL/TATA/RINL)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. SAIL/TATA/RINL
Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. Sink with drain board 1050 mm X 450 mm X 180 mm
Supplying, fitting and fixing shower of approved brand and make. Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge.
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. 60 mm thick interlocking designer concrete paver block M- 35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) Coloured Decorative
Supplying, fitting and fixing yard gully with approved H.C.I. grating complete. 225 mm X 150 mm with 230 mm gratings
SECTION (H) : COMPOUND ROAD Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specifications Clause 201 for Rural Roads of MORD. By Manual Means In area of non-thorny jungle
Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary. Depth above 300 mm & upto 450 mm.
Depth above 450 mm & upto 600 mm.
Granular Sub-base with Graded Material (Table:- 400-1) A. Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). Grading – I With pakur variety
Wet Mix Macadam Base Course Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including screening of aggregates and granular materials, premixing the material with water at OMC in Wet Mix Plant, carriage of mixed material by tipper to site, laying in uniform layers with Paver in Sub- base / Base course on well prepared surface and compacting with Vibratory Roller to achieve the desired density, including supply of all materials, machinery, fuel and lubricants, including incidental costs for lighting, guarding, barricading, making earthen bundh to protect the edges including cost of quality control complete as per Clause 406 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). With Pakur variety
Bituminous Macadam using Hot Mix Plant (HMP) Providing and laying bituminous macadam with Hot Mix Plant using approved crushed aggregates of specified grading as per Table 500.7 premixed with bituminous binder, transported to site laid over a previously prepared surface at specified laying temperature with paver finisher to the required grade, level and alignment and rolled with suitable power roller for break down, inter-mediate and finished rolling as per specification to achieve the desired -compaction including cost and carriage of stone materials and bitumen, hire charges of machinery and equipment, cost of fuel and lubricants and wages of operational staff, quality control complete as per Clause 504 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). B. For Grading 2 (19 mm nominal size, 50-75 mm thick.) With pakur variety
Mastic Asphalt Providing and laying Mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-29 using approved coarse aggregate, fine aggregate, filler material and bitumen, prepared by using Mastic cooker including cost and carriage of all ingredients, cost of heating aggregates and binder, mixing in specified proportions conforming to approved Job Mix Formula and laid to required level and slope after cleaning the surface, compacting, sealing the construction joints and surface finishing conforming to specifications including providing antiskid surface with bitumen pre-coated fine-grained hard stone chipping of 13.2 mm nominal size at the rate of 0.005 cum per 10 sqm and at an approximate spacing of 10 cm center to center in both directions, pressed into surface when the temperature of surfaces not less than 100°C, protruding 1 mm to 4 mm over mastic surface, including the hire charges of all tools and plants and machinery, pay of operators, cost of fuel and lubricants and all other incidental charges and quality control all complete as per Clause 516 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). 25 mm thickness With pakur variety stone materials
Prime Coat Providing and applying primer coat with Cationic Bitumen Emulsion of approved grade conforming to IS: 8887-1978 and requisite quantity on prepared surface of granular base including cleaning of road surface and spraying primer using Mechanical means including cost and carriage of bitumen emulsion and all other incidental costs of work complete as per Clause 502 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). For WBM / WMM Surface: (with primer @ 0.85 kg/sqm)
Tack Coat Providing and applying tack coat with Cationic Bitumen Emulsion of approved grade conforming to IS: 8887-1978 on the prepared surface cleaned with Hydraulic broom, moistening the surface including cost and carriage of emulsion, hire charges of machinery and labour, cost of fuel and lubricants all complete as per Clause 503 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). On Granular surfaces treated with primer (Using Bitumen emulsion at the rate of 0.275 kg per sqm.)
Construction of Embankment with Material Deposited from Roadway Cutting.Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 for Rural Roads of MORD including carriage of material for a distance of 1 km.
Turfing with Sods Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the Engineer including preparation of ground, fetching of sods and watering as per Clause 307 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. 60 mm thick interlocking designer concrete paver block M- 35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) Coloured Decorative
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge. [Note: Subgrade CBR shouldnot be less than 5] Colour Decorative
100 mm thick interlocking designer concrete paver block M-50 grade for hightraffic zone, bus terminus, industrial complex, mandi houses etc. as per IS: 15658- 2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge. [Note: Subgrade CBR shouldnot be less than 5] Colour Decorative
Cast in Situ Cement Concrete M20 Kerb Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (The rate is inclusive of cost of all materials, labour, hire and usage charges of machinery and all incidental charges in this connection.) Using Concrete Mixer
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
R.C. Guard post Supplying fitting and fixing R.C. guard post 1.37m long with C.C. 1:2:4 with graded stone chips of 13.2mm down casting , curing complete including cost of providing 4nos.of 12mm dia. rod of length 1.54m as main reinforcement and 6 nos. of round shaped 8mm dia rods used as binders; the placing of the first binder should be at 75mm below the top finished surface and the other 5 nos of binders should be placed at 245mm c/c ; the guard post is of octagonal section with inscribed circle of dia 24cm at the base tapering to corresponding dimensions of 16cm at the top including two coats of painting with best quality synthetic enamel paint of approved make and grade to form 6 nos. horizontal alternate bands in white/tannery yellow and black to 90 cm length standing up above ground after mending good damages if any during striking off shuttering,making hole in ground of 47cm depth and 30cm. minimum dia, fixing the guard posts in the same holes and repacking the earth properly so as to keep the guard posts standing properly erect in correct position true to line and length including carriage of R. C. Guard Post with due care to the site includingloading into the truck and unloading at site complete in all respect. With Pakur variety stone chips
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). 90 cm equilateral triangle
60 cm equilateral triangle
60 cm circular
Direction and Place Identification Signs upto 0.9 sqm Size Board. Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision)..
Direction and Place Identification Signs with size more than 0.9 sqm size Board. Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision)..
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause 803 of Specifications
Supplying & fixing of Raised Pavement Markers / Road Studs / Cats Eye made of polycarbonate moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face which shall support a load of 13635 kg tested in accordance to ASTM D 4280 Type H and complying to clause no 804 of MoRT&H's specification for Road &Bridge Works (Fifth Rev.). Marker height shall not be less than 10 mm and shall not exceed 20 mm, width shall not exceed 130mm and with minimum reflective area of 13 sq.cm. on each side and slope to the base shall be 35 ± 5 degree. Fixing will be without nails but by using epoxy resin based adhesive as per manufacturer's recommendation including site clearance etc. and complete as directed by the Engineer in Charge .The contractor will have to provide a test certificate from a reputable national/international laboratory conforming the above specifications.
SECTION (I) : CROSS DRAINAGE WORK Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification,including setting out, removing, spreading orstacking of spoils within a lead of 150 m. as directed and including trimming the sides of the trenches,leveling, dressing and ramming the bottom, andbackfilling with approved material complete as per direction of the Engineer-in-Charge . In all sorts of soil excluding marshy soil & rocks (soft or hard) by manual means. upto 3 m depth Without pumping out water and shoring
Plain / Reinforced Cement Concrete in Open foundation with or without reinforcements, in any part of foundation of bridges / culverts with graded stone chips of appropriate nominal sizes, including screening and cleaning of coarse aggregates, fine aggregate (sand) conforming to proper grading zone, both of approved quality and cement, as necessary, cost of curing with water, including cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge, cost for quality control, sampling, testing etc. including cost of formwork but excluding reinforcement complete as per drawing and technical specifications. RCC Grade M20 Using concrete mixer With pakur variety stone chips
E PCC Grade M30 With pakur variety stone chips
Hire and labour charges for Shuttering with or without staging upto 4.0 m height using approved stout props with wooden planks/ply wood/steel sheet plate with required bracing for any kind of plain or reinforced concrete works in all sorts of minor structure including culvert, box culvert, crossdrain etc. The rate is inclusive of fitting, fixing and striking out after completion of work as per specification and direction. Where staging is not required.
Where staging is required.
Supplying, fitting and placing un-coated HYSD bar reinforcement in Bridge Foundation including initial straightening, straightening of coils bars, removal of loose rust (if any), cutting to requisite length bending, binding with annealed wire not less than 1 mm in size and conforming to IS 280 at every intersection hooked and bent to correct shape and placed on forms etc. including cost of black annealed wire and cost of loading, unloading, carriage of all steel materials complete as per drawing and technical specifications and direction of Engineer-in-charge. SAIL/TATA/RINL
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety
Supplying, spreading and compacting Sand to required thickness, in layers not exceeding 150 mm to proper gradient and camber, inundating each layer by water and packing and ramming layer by layer to achieve desired compaction, including lighting, guarding, barricading and making adequate earthen bundh where necessary, curing with water as per direction, mending cracks and depressions by ramming wherever necessary. Using medium sand
Providing weep holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.
Construction of precast RCC railing (to be used in culvert) of M30 Grade, aggregate size not exceeding 12 rnm. true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 rnrn. leaving adequate space between vertical post for expansion, complete as per MoRT&H standard drawing no SD/202 and technical specifications.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 10 mm thick plaster With 1:4 cement mortar
Painting the vertical end faces of posts, wheel guards or railing or parapet with alternate bands of different colours as directed by the Engineer-in-charge with approved synthetic enamel paint. Two Coats
SECTION (J) : BOUNDARY WALL AND LAND DEVELOPMENT Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. In ground floor including roof.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.. Pakur Variety
Supplying and laying Polythene Sheet (150gm/sq.m.) over damp proof course or below flooring or roof terracing or in foundation trenches.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel SAIL/ TATA/RINL For works in foundation, basement and upto roof of ground floor/upto 4 m
Brick work with 1st class bricks in cement mortar (1:4) In superstructure, ground floor
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i) Shuttering without staging in foundation.
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. In ground floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:4 cement mortar 20 mm thick plaster Ground floor
15 mm thick plaster (1:4) Ground floor
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per anumfacturer's specification. One coat on new surface.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One Coat In Ground Floor:
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Premium 100% Acrylic Emulsion In Ground floor (Two Coat)
Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.
SECTION (K) : MAIN ENTRY GATE Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety
Supplying and laying Polythene Sheet (150gm/sq.m.) over damp proof course or below flooring or roof terracing or in foundation trenches.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 30 Grade Pakur Variety Ground floor
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i) Shuttering without staging in foundation.
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. In ground floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel SAIL/ TATA/RINL For works in foundation, basement and upto roof of ground floor/upto 4 m
Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth
In superstructure, ground floor
1st floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in 1st floor.
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3)[with graded stone aggregates 10mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coats of polymer based paint, (1st coat after 4-5 days of concrete laying 2nd coat just before brick masonary work) as directed (cost of water proofing compound & polymer based paint to be paid separately)[chequeing not required over complete or painted surface].
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:6 cement mortar 20 mm thick plaster Ground floor
15 mm thick plaster (1:6) Ground floor
1st floor
10 mm thick plaster (1:4) Ground floor
1st floor
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs Grill weighing above 16 Kg./sq.mtr and above in ground floor.
M.S. works in framed gratings of window etc.made of round or square bars and frame work or M.S. flats (with the bars securely fixed to the flat bar frame) with or without intermediate flat bar stiffener and fixed with necessary screws etc. complete, as directed. in ground floor.
Supplying, Aluminium Grill with F channel frame of approved make and brand having ultimate tensile strength of 19 Kg/Sq.m. and modulus of elasticity 7000 kg/ sq.m., with 15 micron anodised fitted & fixed with necessary screws etc. complete as per direction of Engineer-in-charge.
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. Area of each tile above 0.09 Sq.m Coloured decorative
Supplying fitting and fixing in position 8 mm. to 12 mm. thick Dholpur slab in wall, dado making suitable arrangement to hold the stone properly with approved polymerised adhesives (6 mm thick) as per ISI specification including pointing with cement mortar (1:2) (1 cement: 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of Engineer-in-charge including cost of all materials, labour, scaffolding, staging, curing complete [using white cement for pointing @ 2.4 kg/Sq.m]. In ground floor
Supplying, fitting, fixing marble slab/tiles, 15 mm. to 18 mm. thick in dado / wall in 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks applying white cement slurry @ 4.4 kg/ sq.m at the back side of marble & pointing in cement mortar (1:2) (1 cement, 2 marble dust) with admixture of pigment matching the stone shades including polishing all complete as per direction of the Engineer-in-charge including cost of materials, labours, scaffolding, staging, curing complete. [White cement, Pigment to be supplied by the Agency] With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana. Area of each slab/tile exceeding 0.6 sq.m but not exceeding 1 sq.m.
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white 3 track window
Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; clear, toughened glass conforming to IS: 2553-1992 (part-II) 6mm thick
8mm thick
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. 250mm x 16mm dia bolt.
Supplying, fitting fixing Godrej type hydraulic (oil check) floor door spring, heavy duty double action with brass shoe, brass top centre aluminium top cover etc. complete set as per direction of Engineer-in-charge. 125mm long.
Supplying 4 lever mortice lock or any approved make and brand as per direction of the Engineer- in -Charge. 150 mm.
Supplying 125 mm. Dia acrylic handle for aluminium door as per approved make & brand. Colour
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One Coat In Ground Floor:
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Premium 100% Acrylic Emulsion In Ground floor (Two Coat)
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface :: With other than hi-gloss of approved quality Two coats (with any shade except white)
SECTION (L) : SUB STATION 11KV Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1500 mm
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4 m Tor steel/Mild Steel SAIL/TATA/RINL
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i) Shuttering without staging in foundation.
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. In ground floor
Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth
In superstructure, ground floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C) of P.W.D. SoR for building works
Pre-Constructional Anti-termite measures: (a) Anti termite treatment to bottom surface ( in case of masonry foundation and basements) and the sides (upto a height of 300 mm. from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 6.2.1. of code IS- 6313 (part -II) 1981. (Mode of measurment will be the plan area of foundation treated.)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar 20 mm thick plaster
With 1:4 cement mortar 15 mm thick plaster In ground floor
With 1:4 cement mortar 10 mm thick plaster In ground floor
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] In ground floor
Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] In ground floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. Area of each tile above 0.09 Sq.m Other than Coloured decorative including white In ground floor
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana Area of each Slab/tile exceeding 0.3 sq.m. but not exceeding 0.6 sq.m. In ground floor
M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. In ground floor.
Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete.
PVC Door Shutter-30 mm thick: Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59 mm x30 mm section with 2.0 mm (+/-0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to each other by self tapping screws and 1 solid polymeric or M.S. galvanised tubular 'L' shaped bracket 100mm x 200mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 120 mm x30mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle, reinforced by solid polymer bar of 200 mm long at both ends and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mmx25 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials,labour, and hire of tools and plants and appliancesi/c carriage of all materials taxes and all other incidental charges complete. In ground floor
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs. Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. In ground floor
Supplying fitting and fixing steel rolling grills link type, shutter with 18 B.G .of approved type steel to the section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. In ground floor
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm)
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick). In ground floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One Coat Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (Two coats) Luxury Quality
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: One Coat
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) Premium 100% Acrylic Emulsion
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. on the surface, if necessary : On steel or other metal surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn,Valamoid/Bitumen/M-Seal etc) complete. UPVC Pipes: 110 mm. Dia.
UPVC Fittings: Bend 87.5 degree 110 mm. Dia.
Shoe 110 mm. Dia.
Supplying, fitting and fixing shower of approved brand and make. Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 25 mm dia
Supplying, fitting and fixing bib cock or stop cock. Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
Chromium plated Concealed Stop Cock (Equivalent to Code No.514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Polythene Bib Cock / Stop Cock (HD) with metal inlet (EMCO / ATLAS or equivalent) 15 mm
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. mplete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. For Exposed Work CPVC Pipes Class-1, SDR-11 25 mm
For Concealed Work CPVC Pipes Class-1,SDR-11 15 mm
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2000 litre capacity
Labour for hoisting plastic water storage tank. Above 1500 litre upto 5000 litre capacity. At the roof of ground floor
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. 600 mm long
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps. 900 mm long
Supplying, fitting & fixing Cast iron soil pipe only conforming to I.S. 3989/ 2009 and I.S. 1729/2002 with bobbins, nails etc. including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (Measurement will be made along the center line of the total pipe line in fitted condition including specials,payment for specials & Painting will however be paid seperately). With valamoid joints including sealing with sand cement morter (4:1) upto quarter depth. 100 mm dia. (internal)
Supplying, fitting & fixing H.C.I. bend with door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). With valamoid joints including sealing the top with cement mortar (4:1) 100 mm dia.
Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). 100 mm dia.
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. With 'S' trap
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. Polythene Flush Pipe
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting and fixing bathroom shelf of approved make of size 580 mm x 150 mm (porcelain).
Supplying, fitting and fixing towel rail with two brackets. C.P. over brass 25 mm dia. and 600 mm long
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 Single Socketed 3 Meter Length 75 mm
Single Socketed 3 Meter Length 110 mm
Fittings Door Tee 75 mm
Fittings Door Tee 110 mm
Door Bend (T.S.) 75 mm
Door Bend (T.S.) 110 mm
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials. Above ground 75 mm dia.
Under ground 110 mm dia.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Bazree (N.B Variety) (SAIL/TATA/RINL)
Construction of septic tank of different capacities as per approved drawing of PWD SOR with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. For 30 users With Bazree (N.B Varity) (SAIL/TATA/RINL)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL)
SECTION (M) : SUB STATION 33KV Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety Ground Floor
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
1st. Floor
2nd. Floor
3rd. Floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel/Mild Steel (SAIL/TATA/RINL) For works in foundation and upto roof of ground floor/upto 4 m
1st. Floor
2nd. Floor
3rd. Floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Ground floor
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth
In superstructure, ground floor
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in 1ST. FLOOR
SECOND FLOOR
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).
(c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS- 6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary[Excluding cost of chipping over concrete surface] With 1:4 cement mortar 20 mm thick plaster Ground Floor
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
With 1:4 cement mortar 15 mm thick plaster GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
With 1:4 cement mortar 10 mm thick plaster GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] Ground Floor
FIRST FLOOR
SECOND FLOOR
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. Area of each tile above 0.09 Sq.m Other than Coloured decorative including white FIRST FLOOR
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana Area of each Slab/tile exceeding 0.3 sq.m. but not exceeding 0.6 sq.m. FIRST FLOOR
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Siliguri. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings 32 mm thick shutters (single leaf In ground floor.
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. 66mm x 90mm
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. 32 mm thick In1st. floor
SECOND FLOOR
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.
FIRST FLOOR
SECOND FLOOR
Supplying fitting and fixing steel rolling grills link type, shutter with 18 B.G .of approved type steel to the section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2 track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One Coat Water based interior grade Acrylic Primer GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : In all Floor (Two coats) Luxury Quality
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC In Ground Floor: One Coat
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two Coat) Premium 100% Acrylic Emulsion In Ground floor
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On timber or plastered surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
On steel or other metal surface : Two coats (with any shade except white)
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. UPVC Pipes: 110 mm. Dia.
UPVC Fittings: Bend 87.5 degree 110 mm. Dia.
Shoe 110 mm. Dia.
Supplying, fitting and fixing cast iron heavy type spiral staircase of approved design with 50 mm.dia. Stem and C.I. Steps 150 mm as per design 900 mm. high C.I, railing including necessary M.S. tie of suitable section embedded to wall with cement concrete (1:2:4) including cost of intermediate C.I. platform secured with necessary tie to stem and wall with cement concrete (1:2:4) including fixing the stem in ground with cement concrete (1:3:6) complete in all respect with all labour and materials. With 1200 mm.dia. well
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 50mm. X 1.25mm
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) 40mm X 6mm, 200mm Length
Iron socket bolt of approved quality fitted and fixed complete. 225mm long x 10mm dia bolt.
Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. 250mm long.
Door stopper.(Brass)
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: With continuous plate base (Hexagonal/ Round rod) 150 mm grip x 10 mm dia rod.
Supplying, fitting and fixing shower of approved brand and make. Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 25 mm dia
Supplying, fitting and fixing bib cock or stop cock. Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
Chromium plated Concealed Stop Cock (Equivalent to Code No. 514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Polythene Bib Cock / Stop Cock (HD) with metal inlet (EMCO / ATLAS or equivalent) 15 mm
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. For Exposed Work CPVC Pipes Class-1, SDR-11 25mm
For Concealed Work CPVC Pipes Class-1,SDR-11 15 mm
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2000 litre capacity
Labour for hoisting plastic water storage tank. Above 1500 litre upto 5000 litre capacity. At the roof of 3rd floor from Ground floor.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. 600 mm long
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. 900 mm long
Supplying, fitting & fixing Cast iron soil pipe only conforming to I.S. 3989/ 2009 and I.S. 1729/2002 with bobbins, nails etc. including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (Measurement will be made along the center line of the total pipe line in fitted condition including specials,payment for specials & Painting will however be paid seperately). With valamoid joints including sealing with sand cement morter (4:1) upto quarter depth. 100 mm dia. (internal)
Supplying, fitting & fixing H.C.I. bend with door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). With valamoid joints including sealing the top with cement mortar (4:1) 100 mm dia.
Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). 100 mm dia.
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. With 'S' trap
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. Polythene Flush Pipe
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting and fixing bathroom shelf of approved make of size 580 mm X 150 mm (porcelain).
Supplying, fitting and fixing towel rail with two brackets. C.P. over brass 25 mm dia. and 600 mm long
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 Single Socketed 3 Meter Length 75 mm
Fittings Door Tee 75 mm
Door Bend (T.S.) 75 mm
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials. Above ground 75 mm dia.
110 mm dia.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. with Bazree (N.B Variety) (SAIL/TATA/RINL)
Construction of septic tank of different capacities as per approved drawing of PWD SOR with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code For 30 users With Bazree (N.B Varity) (SAIL/TATA/RINL)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL)
SECTION (N) : ELECTRICAL & ELECTRO- MECHANICAL WORKS PART (E-1) : SITC OF MAIN SUB-STATION VCB PANEL & TRANSFORMERS Supply & Delivery of Indoor-type, floor mounted,metal clad, single tier, fully compartmentalized,free standing, 11 kV VCB Panel with 3 Nos VCBs (1 Incomer + 2 Outgoing), totally enclosed and fully interlocked , horizontal drawout, horizontal / vertical isolation type breaker as per IS 13188, as ammended upto date and as per detail specification attached ( uploaded in the specification section) , suitable for use on 11 KV, 3 Phase,50 Hz AC supply to energise Two nos 1600 KVA Oil Type Transformers. [ Make : ABB / Siemens / CGL].
Installation & commissioning of the above 11 kV VCB Panel with P.T & all the accessories, incl. carriage, by placing in position, assembling, lining up, levelling and checking all instruments, relays, correctly set according to requirement.
Supply & delivery of Oil type Indoor type Corrugated Tank design 1600 KVA 11kV/433V, 3 phase, 50 Hz, Dyn11, KNAN type Sealed type Copper wound Transformer with all accessories i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) as per detailed specification attached.
Installation & commissioning of 11 KV/ 415 volt, two 1600 KVA Oil type distribution transformer incl. carriage to the substation building within a lead of 30mtr by placing in position and fixing after leveling fitting all components, connecting, checking & set of all instrument, relays according to requirement as instructed by the EIC incl. S&F base channels etc.
SITC of floor mounted Indoor type extensible cubical MV switchboard,fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel,front and back openable, hinged, single shuttered, with incoming ACBs & Outgoing MCBS and all accessories as per size, design & drawing to be approved by EIC and conforming to IS with latest modification and as per detail specification attached (uploaded in the specification section) [LT MAIN PANEL IN THE SUBSTATION]
Making testing arrangement and submitting the test report for high voltage testing of specified voltage incl. checking & testing of all HT / LT equipments by authorized firm of Directorate of Electricity & commissioning the installation after obtaining the Approval of Directorate of Electricity.The scope shall be also included the necessary approval from Authority also.
Supply & fixing 75x45 mm "C" channel having length of 2 mtr. each channel incl. nuts, bolts and washer etc.
APFC PANEL Supply & delivery, Installation, Testing & Commissioning of AUTOMATIC POWER FACTOR CORRECTION PANEL (must be designed for 1600 KVA) and conforming to IS with latest modification to be integrated with LT Panel at HT Substation Building. The APFC panel is to be designed by bidder.
HT/ LT CABLING IN SUBSTATION Supplying of 11KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable conforming to IS 7098, of earthed system of following size.[ From Supplier HT Gear to Consumer HT Gear and to Transformer]. [Make : Nicco / Gloster/Polycab/Havells/Crystal] 3 Core x 240 Sq.mm
Making heatshrinkable joints indoor type to the ends of the following XLPE HT cable at the transformer end as well as at the VCB ends supplying with necy. jointing kits (Raychem), sockets, sleeves, anti-corrossive paste, wires, solders, jointing compounds, rubber sheets etc. incl. supplying of necy. tools & tackeles for crimping the end sockets, soldering irons & making of glands at the both end of the cable as per directions of EIC. 3 Core x 240 Sq.mm
Laying of 1 No. 11KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable confirming to IS 7098, of earthed system of following size in the existing Masonary Open Duct as required. 3 core 240 sqmm 11KV XLPE HT cable
Supply & fixing of sheet steel bus-trunking of approx. overall dimension of 700 mm (width) & 300 mm (height) fabricated from 16 SWG sheet steel and MS frame made of 40 x 40 x 6 mm angle with detachable front cover & equipped with 4 nos copper bar of size (2 x 75mm x 12 mm) or equivalent for 3-Phases & neutral duly mounted on insulated chair with heat shrink colour sleeves. The bus-trunking will be suspended from the ceiling with necy. mouting rod / angle etc. as required. The bus-trunking will be duly powder coated paint. [ From secondary terminal of 2 nos. 1600 KVA transformer to 2 nos 2500A ACB of LT panel board ]
S&F copper braded link for Transformer bushing (Secondary) to Bus duct and Busduct to Incomer ACB of LT panel as per direction of EIC.
Supply & Drawing 1.1 KV Grade 10 Core 1.5 sq.mm PVC Armoured Copper Cable from Transformer WT relay to VCB WT relay for Power & Control Supply as per direction of EIC.
EARTHING S & laying 300 sq. mm. single core multistrand PVC insulated flexible Cu wire in suitable size of PVC flexible pipe (reinforced) from nutral earth busbar to transformer point as required (for Transformer /Generator neutral earthing) including Socketing both sides by Cu Socket.
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level as per detail specification attached ( uploaded in the specification section) [ FOR TRANSFORMER NEUTRAL AND DG SET EARTHING ]
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Supply & fixing earth busbar of galvanized (Hot dip) MS flat 65 mm x 8 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Insulating the 65 x 8 mm M.S. flat incl. S&F black heat shrink PVC sleeves etc. The PVC tube sleeve to be inserted on the GI flat and heat shrinked by heating apparatus by skilled technician carefully without damaging the PVC sleeve as per direction of the EIC (for transformer neutral earth bus bar).
Providing and fixing 50 mm X 6 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
S & F special type earth electrode clamp made of GI flat with nuts, bolts,, washer etc. suitable for 80 mm dia GI pipe earth.
SAFETY EQUIPMENT Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscription in signal red colour on front side as required. High Voltage - size 250mm x 200mm
Medium Voltage - size 200mm x 150mm
Providing and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 15222-2002 and cylinders fully charged of following capacity(4.5 Kg ) [Make - Fire Shield/ Ceasefire]
Supply and fixing of foam fire extinguishers conforming to IS 4989-2006, Portable type 9 lit capacity hanged on wall with bracket complete as required. [Make - Fire Shield/ Ceasefire]
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (approx. Front area 1.20 sq.mt.)
Providing of set of 4 nos. 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame with bracket and suitable base of appropriate size & capacity I/c filling sand etc.
Providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 13115-1991.
Supply and fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as reqd. (approximate front area 1.20 sq.metre).
Providing of rubber mat 2 mtrs Length x 1 m. wide and 12mm thick to withstand 15 KV dielectric strength as per IS 15652-2006.
Providing of rubber mat 2 mtrs Length x 1 m. wide and 6mm thick to with stand 3.3 KV dielectric strength as per IS 15652-2006.
S/F of 860 mm wide and 8 mm thick M.S checker plate including painting for covering the trench.
LT CABLE FROM SUBSTATION TO BUILDING Supplying of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade conforming to IS 7098 of following size in the existing Masonary Open Duct. [ From TR & DG set to main panel]. [Make : Nicco / Gloster / Polycab / Havells / Crystal] a) 4Core x 400 sq.mm
b) 4Core x 300 sq.mm
c) 4Core x 240 sq.mm
d) 4Core x 185 sq.mm
e) 4Core x 150 sq.mm
f) 4Core x 120 sq.mm
g) 4Core x 95 sq.mm
h) 4Core x 70 sq.mm
i) 4Core x 50 sq.mm
j) 4Core x 25 sq.mm
Laying of cable through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand [4/F3] a) 4Core x 400 sq.mm
b) 4Core x 300 sq.mm
c) 4Core x 240 sq.mm
d) 4Core x 185 sq.mm
e) 4Core x 150 sq.mm
f) 4Core x 120 sq.mm
g) 4Core x 95 sq.mm
h) 4Core x 70 sq.mm
i) 4Core x 50 sq.mm
j) 4Core x 25 sq.mm
Laying of one cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [1/F2] a) Up to 35 Sqmm
b) above 35 sqmm and upto 185 sqmm
c) above 185 sqmm
Laying of two cables in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed [2/F2] a) Up to 35 Sqmm
b) above 35 sqmm and upto 185 sqmm
c) above 185 sqmm
Laying of three cables in an underground trench in single tier formation (horizontal) the trench size : 915 mm x 760 mm average depth with brick protection on the top of each cable with 8 nos. bricks per Mtr. and 4 nos. bricks per mtr. as separator between the cables including filling the space between the bricks and cables and also the trench with shifted soil, levelling up and restoring surface duly rammed [3/F2] a) Up to 35 Sqmm
b) above 35 sqmm and upto 185 sqmm
c) above 185 sqmm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish [5/F3] a) Up to 35 Sqmm at an average depth of 75 mm
b) above 35 sqmm and upto 95 sqmm at an average depth of 100 mm
c) above 95 sqmm at an average depth of 100 mm
Supplying and making end termination with Brass compression gland and aluminium lugs for the following sizes of PVC insulated and PVC sheathed aluminium conductor cable of 1.1 KV Grade as required a) 4Core x 400 sq.mm
b) 4Core x 300 sq.mm
c) 4Core x 240 sq.mm
d) 4Core x 185 sq.mm
e) 4Core x 150 sq.mm
f) 4Core x 120 sq.mm
g) 4Core x 95 sq.mm
h) 4Core x 70 sq.mm
i) 4Core x 50 sq.mm
j) 4Core x 25 sq.mm
SITC of DG SET Supply , delivery at site on foundation , Testing & commissioning of one no. 1500 KVA , 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, separate AMF panel with in built By Pass, Base frame, Fuel tank, Battery, CPCB-II approved Engine & Acoustic Enclosure (As per details specifications)
Supply , delivery at site on foundation , Testing & commissioning of one no. 1010 KVA , 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, separate AMF panel with in built By Pass, Base frame, Fuel tank, Battery, CPCB-II approved Engine & Acoustic Enclosure (As per details specifications)
INSTALLATION of DG S &F MS angle iron structure made of (80x80x6) mm/(50x50x6) mm MS angle to support 300/250 mm dia MS pipe &Fuel tank support for DG sets incl. painting as per per GS.
Supply & fixing of exhaust gas piping of suitable dia welded black 300 mm dia MS class B pipe incl. all necessary bend, tee, sockets, plug, supports and clamps anti-vibration mounting insulation of exhaust system with 50 mm thick mineral wool covered with wire mesh and aluminium cladding ( from DG sets to top of the building plus 3mtr or as per CPCB)and as per direction of EIC.
Supply & fixing of exhaust gas piping of suitable dia welded black 250 mm dia MS class B pipe incl. all necessary bend, tee, sockets, plug, supports and clamps anti-vibration mounting insulation of exhaust system with 50 mm thick mineral wool covered with wire mesh and aluminium cladding ( from DG sets to top of the building plus 3mtr or as per CPCB) and as per direction of EIC.
Painting the 300/250 mm dia MS black pipe by Aluminium paint of two coat over the RO primer (approved make)
S&F rain protection canopy for exhaust pipe
Hire charges for scaffolding by bamboo required rope of square type arrangement for smooth working & carriage of MS black pipe by vertical run & dismantling at the end of work.
S &D of HSD for testing & immediate run of DG set incl. carrying charge
Supply and laying of 10core 2.5sqmm copper Armoured control cable,after cutting floor/pavent/wall/and making holes incl. Embedding the cable at an average depth as 75mm and mending good the damages to original finish incl. Removing the rubbish
Supply and laying of 2core 6sqmm copper Armoured control cable, after cutting floor/pavent/wall/and making holes incl. Embedding the cable at an average depth as 75mm and mending good the damages to original finish incl. Removing the rubbish
Supply & Laying of single core 240 Sqmm Copper Aurmoured cable, (Havells/ Gloster/ Polycab/RRKable/Crystal) after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as 100mm and mending good the damages to original finish incl. removing the rubbish.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of XLPE/PVC armoured cable as below. Single core 240 Sqmm Armoured cable
10 core 2.5Sqmm Armoured cable
2 core 6Sqmm Armoured cable
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying dowells make sockets, tapes. Single core 240 Sqmm copper wire by dowels make heavy duty long barrel Copper socket.
10 core 2.5Sqmm Armoured cable
2 core 6Sqmm Armoured cable
DISTRIBUTION WIRING of SUB STATION Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 6 Way
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+8 Way[ Legrand ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 32 A DP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 SP
Distn. wiring in 3X22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Finolex/ Polycab/ Havells/ RR Kabel] in 19 mm bore, 3 mm thick polythen pipe with all accessories embedded in wall to light / fan / call bell points as per GS with following average run [ As per approved list of Material ] 10 Mtr
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Finolex/ Polycab/ Havells/ RR Kabel] in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point as per GS.[ As per approved list of Material ] On Board
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.[ As per approved list of Material] 19 mm dia 3 mm thick
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Finolex/ Polycab/ Havells/ RR Kabel] of the following sizes in the prelaid polythene pipe as per GS.[ As per approved list of Material ] 2x(2.5 sqmm)+1x(1.5 sqmm)[ for 16 A Power plug, Computer Board ] [ 1(s) / E-9 ]
2x (6 sqmm) + 1x (4 sqmm) [ For 32 A Outlet ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc including supplying sockets, tapes. [ 9 / F 5 ] 2x(2.5 sqmm)+1x(1.5 sqmm)
2x (6 sqmm) + 1x (4 sqmm)
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS 150 x 100 x 65
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch on sheet metal switch board embedded in wall as per GS.
Supply & Fixing 240 V, 20A Piano key type switch on sheet metal switch board embedded in wall as per GS incl. S&F of Box top cover etc.
Supply & Fixing Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switch board as per GS.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification as per GS.
Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves) a. 1200 mm Sweep ( Crompton Standard Hi Speed/ Orient High Speed )
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC Heavy Duty) [ NS ] 12"( 300mm ) Speed 920 RPM
Fixing only exhaust fan after making holes in wall as per GS (12")
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS (12")
Supply & Fixing Timer for controlling of exhaust fan fixed on wall in MS Box with top cover (L&T Micon225/equivalent Legrand).
Supply & Fixing of LED light fittings (Make Philips/Crompton) a) 1x 18W TMC 501 TLED with 1 no 18W Master LED Lamp (Make Philips/Crompton)
b) 15W LED bulb (Philips/Crompton)
PART (E-2) : E.I WORK OF COURT BUILDING DISTRIBUTION WIRING Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch ([ As per approved list of Material ]) as per GS 10 Mtr.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire [ As per approved list of Material ] partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch [ As per approved list of Material ] 10 Mtr.
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with Modular type plug socket & switch as per GS.[ As per approved list of Material ] On Board
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.[ As per approved list of Material] 13 mm dia 3 mm thick
19 mm dia 3 mm thick
25mm dia 3 mm thick
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS.[ As per approved list of Material ] 3x(1.5 sqmm) [ for 6 A seperate plug ]
2x(2.5 sqmm)+1x(1.5 sqmm)[ for 16 A Power plug, Computer Board ]
2x(4 sqmm)+1x (2.5 sqmm)[ For RAC ]
2x (6 sqmm) + 1x (4 sqmm) [ For 32 A Outlet ]
2x(10 sqmm)+1x(6 sqmm) [ For 40 A Outlet ]
4x(10 sqmm)+2x(6 sqmm) [ For 3P, 40 A Outlet ]
4x(16 sqmm)+2x(10 sqmm) [ For 3P, 63 A Outlet ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc including supplying sockets, tapes. 3x(1.5 sqmm)
2x(2.5 sqmm)+1x(1.5 sqmm)
2x(4 sqmm)+1x (2.5 sqmm)
2x (6 sqmm) + 1x (4 sqmm)
2x(10 sqmm)+1x(6 sqmm)
4x(10 sqmm)+2x(6 sqmm)
4x(16 sqmm)+2x( 10 sqmm)
Supplying and fixing polythene pipe (3mm thick) complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire as per GS.[ As per approved list of Material ] 13mm dia.
19mm dia.
25mm dia.
32mm dia.
40mm dia.
50mm dia.
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS. 100 x 100 x 65
Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc as per GS. 20x10mm Size
25x10mm Size
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. [ For Fire Detection ] 20 mm Size
25 mm Size
BDB, PDB, VTPN ETC. Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+10 Way [Simens ]
2+12 Way[ Legrand ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 4 Way
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS( Make - Legrand ) 4 Way ( Up to 160 A )
6 Way ( Up to 160 A )
8 Way ( Up to 160 A )
12Way( Up to 160 A )
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 4 Way
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 32 A DP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 SP
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand ]. 63A FP
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as per GS [ Make L& T ]. 160A
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall as per GS.( Make -Simens ). 32A
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal enclosure with IP-42/43 as per GS. 4 Way
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB vertical enclosure with IP-42/43 as per GS. 4/6 /8 /12Way
SUPPLY & LAYING OF CABLES Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/ Finolex/Crystal/ Polycab] 4 Core50 Sq. Mm
4 Core70 Sq. Mm
4 Core95 Sq. Mm
4 Core120 Sq. Mm
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes. Up to 95 Sq. Mm
Above 95 Sq. Mm
Laying of cable above 35 and upto 185sqmm in underground trench as per GS for the following numbers of Cables. 1 No Cable
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4Core 95 Sq. Mm
4Core 120 Sq. Mm
PLUGS & SOCKETS Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket with 6A Modular type switch as per GS.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switch, without plug top as per GS
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch, 16A Modular switch type MCB as per GS
FIXING OF LIGHT FITTINGS Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch, 16A Modular switch type MCB as per GS.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit as per GS
Fixing only recess type LED luminaire round/square in false ceiling by making housing in false ceiling and necy. connection by S&F of 2 x1.5mm² PVC insulated Cu. Wire as per direction of EIC.
Fixing only surface type LED luminaire in ceiling with bullet, nut, bolt etc. and necy. connection by S&F of 2 x1.5mm² PVC insulated Cu. Wire as per direction of EIC.
SUPPLY OF LIGHT FITTINGS Supply of Industrial type fittings Supply of Single LED T8 T/L fittings [Philips TMC 501 P 1xT-LED 22W P3241) incl. 1x MAS LEDtube 1200mm 18W865 T8 I (PC Body)/ Equivalent product of Crompton/Wipro having similar specification in all respect].
Supply of Twin LED T8 T/L fittings [Philips TMC 501 P 2xT-LED 22W P3242) incl. 2x MAS LEDtube 1200mm 18W865 T8 I(PC Body) Equivalent product of Crompton/Wipro having similar specification in all respect].
Supply of recess mounted 2' x 2' LED luminaries. Supply of Twin LED T8 T/L fittings [Philips TMC 501 P 2xT-LED 22W P3242) incl. 2x MAS LEDtube 1200mm 18W865 T8 I(PC Body) Equivalent product of Crompton/Wipro having similar specification in all respect].
Philips Model RC 380B LED 36S-4000/6500 G4 L60W60 PSU OC/ Equivalent product of Crompton/ Wipro/ Jaquar having similar specification in all respect
Philips Model RC 240B LED 33S-6500 PSU OD/ Equivalent product of Crompton/ Wipro / Jaquar having similar specification in all respect. Supply of surface mounted 2' x 2' LED luminaries.
Jaquar Model Sauver LSVR01S036SC/ Equivalent product of Crompton/ Wipro/ Philips having similar specification in all respect. Supply of recess mounted square LED luminaries.
Philips Model Ultima Square DN097B LED10S 6500 PSU WH/ Equivalent product of Crompton/ Wipro / Jaquar having similar specification in all respect. Supply of recess mounted round LED luminaries.
Philips Model Ultima DN092B LED10S 6500 PSU WH/ Equivalent product of Crompton/ Wipro / Jaquar having similar specification in all respect. Supply of surface mounted square LED luminaries.
Jaquar Model Neve Surface LNVE02S0125C/ Equivalent product of Crompton/ Wipro/ Philips having similar specification in all respect. Supply of surface mounted round LED luminaries.
Jaquar Model Neve Surface LNVE02R0125C/ Equivalent product of Crompton/ Wipro/ Philips having similar specification in all respect. Supply of Cob Down Light
Jaquar Model Estus Swivel (tiltable) LETS25R012XC/ Equivalent product of Crompton/ Wipro/ Philips having similar specification in all respect.
FIXING OF FANS Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA as per GS
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board as per GS
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Extra for supplying additional wire for down rod & painting the rod as per GS
Drilling hole on fan motor and downrod incl. S&F split pin as per GS
Engraving the deptt. number with 10 mm lettering on the body as per GS
Extra for additional one letter incl. hifen, stroke and stop as per GS
Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS
Extra painting for additional one letter of the engraved number as per GS
Fixing only exhaust fan after making holes in wall as per GS (9")
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS. (9")
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS. (12")
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers as per GS
SUPPLY OF FANS Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves ) 1200 mm Sweep ( Aura Metallic )
1400 mm Sweep ( Aura Metallic )
Supply of Heavy Duty Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) 9" ( 230mm ) Speed 1370 RPM
12"( 300mm ) Speed 920 RPM
Supply of Wall Mounting Cabin Fan complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves ) 12"( 300mm ) [WMWind Flow ( HI-Speed) ]
16"( 400mm ) [WMWind Flow ( HI-Speed) ]
18"( 450mm ) [WM Cressida ]
MISCELENEOUS Supplying & Fixing 240 V AC/DC superior type Multitune (min 10 nos. tune) Call Bell (Anchor) on HW board as per GS
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS
EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming as per GS. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) as per GS
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm as per GS
Extra for treatment of soil by using salt & charcoal or coke for plate electrode as per GS
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS. 4SWG
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS
LT PANEL SITC of LT,Cubicle Type,Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz,as per size, design & drawing to be approved by EIC.The panel board will be fabricated by CPRI approved panel maker as per detail specification(Uploaded in the Specification Section). [LT PANEL FOR LIGHT FAN AT BLOCK A & F AND BLOCK C & D]
SITC of LT,Cubicle Type,Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz,as per size, design & drawing to be approved by EIC.The panel board will be fabricated by CPRI approved panel maker as per detail specification(Uploaded in the Specification Section). [LT PANEL FOR LIGHT FAN AT BLOCK B & E]
SITC of LT,Cubicle Type,Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz,as per size, design & drawing to be approved by EIC.The panel board will be fabricated by CPRI approved panel maker as per detail specification(Uploaded in the Specification Section). [LT PANEL FOR LIFT & AHU at BLOCK A & F]
SITC of LT,Cubicle Type,Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz,as per size, design & drawing to be approved by EIC.The panel board will be fabricated by CPRI approved panel maker as per detail specification(Uploaded in the Specification Section). [LT PANEL FOR LIFT & AHU at BLOCK C & D]
SITC of LT,Cubicle Type,Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz,as per size, design & drawing to be approved by EIC.The panel board will be fabricated by CPRI approved panel maker as per detail specification(Uploaded in the Specification Section). [LT PANEL FOR LIFT at BLOCK B & E]
SITC of LT,Cubicle Type,Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz,as per size, design & drawing to be approved by EIC.The panel board will be fabricated by CPRI approved panel maker as per detail specification(Uploaded in the Specification Section). [LT PANEL FOR AHU at BLOCK B & E]
PART (E-3) : Electrical Installation of Auditorium DISTRIBUTION WIRING Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) as per GS 8 Mtr.
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with Modular type plug socket & switch as per GS. On Board
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. 19 mm dia 3 mm thick
25 mm dia 3 mm thick
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. 3 x (1.5 sqmm) [for separate 6A PP]
2x(2.5 sqmm)+1x(1.5 sqmm) [For separate 16A & Computer point]
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin / ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 3 x (1.5 sqmm)
2x(2.5 sqmm)+1x(1.5 sqmm)
2x (6 sqmm) + 1x (4 sqmm)
BDB, PDB, VTPN ETC. Supplying and fixing 415V TPN with fuse on L&N Sheet steel Main Switches on angle iron frame on wall. 60/63 A ( Make- Siemens)
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.( Make - Legrand ) 4 way Enclosure (607913)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+12 Way[ Legrand ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 4Way
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 40 A DP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 SP
40 A TP MCB
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. 63 A FP
SUPPLY & LAYING OF CABLE Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size. [ Make Nicco / Fort Gloster/Polycab/Havells] 4 Core 35 Sq. mm [ Main switch to VTPNDB]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish including removing the rubbish. From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below including finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. 4 Core 35 Sq. mm
PLUGS & SOCKETS Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket with 6A Modular type switch as per GS ( For seperate plug)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switch, without plug to as per GS (For power plug)
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch, 16A Modular switch type MCB as per GS (For computer board)
Supply & Fixing 25 A Modular type Socket on 2 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board as per GS (For air-conditioning & Gyser)
FIXING OF LIGHT FITTINGS Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS.
Fixing only lamp
Fixing only 2'x2' LED fittings on False ceiling after cutting the false ceiling incl. necessary fixing materils as required and mending goods the damages to original finish.
Fixing only bulk head ceiling fitting on wall /ceiling by screws etc.
Fixing only 312mmx312 mm LED fittings complete with all accessories directly on wall/ceiling by screws etc.
Fixing only Square LED fittings on False ceiling after cutting the false ceiling incl. necessary fixing materils as required and mending goods the damages to original finish.
SUPPLY OF LIGHT FITTINGS Supply of 4 Ft. 40 Watt single/twin florescent light fitting for indoor application,complete with all accessories & Lamps having following Model / Cat No.( Make -Philips) BN108C LED 40S PSU CDL WH
Supply of 10 W LED Lamp
Supply of LED Light Fittings for indoor application,complete with all accessories including lamps having catalogue and model as specified below.[NS ] (a) Cirrus Mini Pro (Philips Make, Cat.No. SM200C LED16S 6500 PSU OD WH)
(b) Full Glow Fully diffused Recessed mounted LED Fittings ( Philips Make, Cat. NO.RC380B LED36S-4000 G4 L60 W60 PSD OD)
(c) Full Glow Fully diffused Recessed mounted LED Fittings ( Philips Make, Cat. NO.RC380B LED36S-6500 G4 L60 W60 PSU OD)
(d) Endura LED Bulkhead (Make-Philips, Cat. No. WT202W LED6S NW PSU S2 PC)
(e) 22 watt Square LED Panel light (Make-Philips, Model No. 59109)
FIXING OF FANS Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA as per GS
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board as per GS.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS.
Extra for supplying additional wire for down rod & painting the rod as per GS.
Fixing only exhaust fan after making holes in wall as per GS.
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS.
SUPPLY OF FANS Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves ) [ NS ] 1400 mm Sweep ( Aura Metallic )
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) [ NS ] 9"( 230mm )Speed 1370 RPM
EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming as per GS. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS.
Connecting the equipments to earth busbar including S & F 4 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
LT PNNEL SITC of LT,Cubicle Type,Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz,as per size, design & drawing to be approved by EIC.The panel board will be fabricated by CPRI approved panel maker as per detail specification [LT PANEL for AUDITORIUM]
PART (E-4) : Electrical Installation of SWIMMING POOL DISTRIBUTION WIRING Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) as per GS 8 Mtr.
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with Modular type plug socket & switch as per GS. On Board
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. 19 mm dia 3 mm thick
25 mm dia 3 mm thick
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. 3 x (1.5 sqmm) [for separate 6A PP]
2x(2.5 sqmm)+1x(1.5 sqmm) [For separate 16A & Computer point]
2x(4 sqmm)+1x(2.5 sqmm) [ For 2 Tr. AC Machine]
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin / ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 3 x (1.5 sqmm)
2x(2.5 sqmm)+1x(1.5 sqmm)
2x(4 sqmm)+1x (2.5 sqmm)
2x (6 sqmm) + 1x (4 sqmm)
4x16 sqmm + 2x10 sqmm
BDB, PDB, VTPN ETC. Supplying and fixing 415V TPN with fuse on L&N Sheet steel Main Switches on angle iron frame on wall. 60/63 A ( Make- Siemens)
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.( Make - Legrand ) 4 way Enclosure (607913)
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 4Way
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+12 Way[ Legrand ]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 2 Way
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 40 A DP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 SP
40 A TP MCB
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. 63 A FP
SUPPLY & LAYING OF CABLE Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size. [ Make Nicco / Fort Gloster/Polycab/Havells] 4 Core 35 Sq. mm [ Main switch to VTPNDB]
2 Core 6 Sq. mm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish including removing the rubbish. From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Laying of one No. cable upto 35 sqmm in underground trench 460mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below including finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. 4 Core 35 Sq. mm
2 Core 6 Sq. mm
PLUGS & SOCKETS Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket with 6A Modular type switch as per GS ( For seperate plug)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switch, without plug to as per GS (For power plug)
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch, 16A Modular switch type MCB as per GS (For computer board)
Supply & Fixing 25 A Modular type Socket on 2 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board as per GS (For air-conditioning )
Supply & Fixing 240 V 16 A Modular type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required.
FIXING OF LIGHT FITTINGS Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS.
Fixing only lamp
Fixing only 2'x2' LED fittings on False ceiling after cutting the false ceiling incl. necessary fixing materils as required and mending goods the damages to original finish.
Fixing only 312mmx312 mm LED fittings complete with all accessories directly on wall/ceiling by screws etc.
Fixing of City cube Bollard with suitable size of muffing (as per direction of EIC) incl. necessary fixing materials.
SUPPLY OF LIGHT FITTINGS Supply of 4 Ft. 40 Watt single/twin florescent light fitting for indoor application,complete with all accessories & Lamps having following Model / Cat No.( Make -Philips) LED Tube Cat. No. BN108C LED 40S PSU CDL WH
Supply of 10 W LED Lamp
Supply of LED Light Fittings for indoor application,complete with all accessories including lamps having catalogue and model as specified below.[NS ] (a) Cirrus Mini Pro (Philips Make, Cat.No. SM200C LED16S 6500 PSU OD WH)
(b) Full Glow Fully diffused Recessed mounted LED Fittings ( Philips Make, Cat. NO.RC380B LED36S-4000 G4 L60 W60 PSD OD)
Supply of City cube Bollard D (Make-Philips, Cat. No. BCP400 LED09 CW PSU GR S1)
FIXING OF FANS Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA as per GS
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board as per GS.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS.
Extra for supplying additional wire for down rod & painting the rod as per GS.
Fixing only exhaust fan after making holes in wall as per GS.
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS.
SUPPLY OF FANS Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves ) [ NS ] 1400 mm Sweep ( Aura Metallic )
900 mm Sweep ( Aura Metallic )
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) [ NS ] 9"( 230mm )Speed 1370 RPM
12"( 300 mm ) Speed 1420 RPM
EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming as per GS. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS.
Connecting the equipments to earth busbar including S & F 4 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
Air Conditioning Machines Supply & Delivery of Hi-wall Split Air Conditioner of actual capacity 2 TR as detail specification.
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including S&F of necessary fixing arrangement for indoor and outdoor unit, duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. (i) Supply & Fixing of extra refrigerant pipe with insulation foam insulation (as requisite dia) [each mtr Refrigerent pipe will include cost of 1 metre liquid pipe line and 1 mtr gas pipe line of required dia].
Do----Do----Do (ii) 3 core 2.5 sq mm PVC insulated FRLS grade copper cable (make : Finolex/ Havells/Polycab)
Supply & Fixing of PVC drain pipe (make approved by EIC)
S&F MS platform with railling for maintenance of the outdoor units of AC machine fabricated from MS angle/flat etc including painting and as directed by EIC for above machines [design and drwaing to be approved by EIC before fabrication]
Supply & fixing of OLP 30 with current display, overload protection, timedelay between consicutive start AC machines starter on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F Modular board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
MISCELENEOUS Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 40 mm dia.
Supplying & Fixing GI Modular Switch Board of the followingsizes complete with top cover plate flushed in wall for housingthe board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 4 Module
PART (E-5) : LIGHTNING ARRESTER S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar (4:2:1)
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works. Length upto 0.5 Mtr.
Length above 0.5 Mtr.
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint.
Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint.
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run.
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works.
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work.
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
PART (E-6) : Electrical Installation of CHIEF JUISTICE BUNGLOW DISTRIBUTION WIRING Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) as per GS 8 Mtr.
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with Modular type plug socket & switch as per GS. On Board
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. 13 mm dia 3 mm thick
19 mm dia 3 mm thick
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. 3 x (1.5 sqmm)
2x(2.5 sqmm)+1x(1.5 sqmm)
2x(4 sqmm)+1x(2.5 sqmm)
2x(6 sqmm)+1x(4 sqmm)
2x (10 sqmm) + 1x (6 sqmm)
Finishing of the PVC insulated wire ends by socketting with pin / ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 3 x (1.5 sqmm)
2x(2.5 sqmm)+1x(1.5 sqmm)
2x(4 sqmm)+1x (2.5 sqmm)
2x (6 sqmm) + 1x (4 sqmm)
2x (10 sqmm) + 1x (6 sqmm)
BDB, PDB, VTPN ETC. Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+16 Way[ Legrand ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 4Way
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Up to 160A) [Make-Legrand] 4 way
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 40 A DP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 SP
32 A TP MCB
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Make-Legrand). 80A
PLUGS & SOCKETS Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket with 6A Modular type switch as per GS ( For seperate plug)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switch, without plug to as per GS (For power plug)
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch, 16A Modular switch type MCB as per GS (For computer board)
Supply & Fixing 25 A Modular type Socket on 2 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board as per GS (For air-conditioning )
FIXING OF LIGHT FITTINGS Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS.
Fixing only LED Bracket / Mirror light fitting complete ith all accessories Directly on wall/ceiling as per GS. [NS] [ 16 No x 15 units]
SUPPLY OF LIGHT FITTINGS Supply of 4 Ft. 40 Watt single/twin florescent light fitting for indoor application,complete with all accessories & Lamps having following Model / Cat No.( Make -Philips) TMC 501P 1XT-LED 20W P3242) incl. 1xMAS LED TUBE 1200mm 18 W 865 T8I 2100lm (PC body)
Supply of LED Light Fittings for indoor application,complete with all accessories including lamps having catalogue and model as specified below.[NS ] Wall Light fittings with 1 No 6 Watt CDL LED Lamp ( 550 Lumen ) [ Philips Home Decor Cat No. 80926/67(QWG 307)]
Mirror Light fittings with 1 No 2.7 Watt LED Candle Lamp (230 Lumen ) [ Philips Home Decor Cat No. 32044/11 ]
FIXING OF FANS Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA as per GS
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board as per GS.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS.
Extra for supplying additional wire for down rod & painting the rod as per GS.
Fixing only exhaust fan after making holes in wall as per GS.
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS.
SUPPLY OF FANS Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves ) [ NS ] 1400 mm Sweep ( Aura Metallic )
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) [ NS ] 9"( 230mm )Speed 1370 RPM
EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming as per GS. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS.
Connecting the equipments to earth busbar including S & F 4 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
Air Conditioning Machines Supply & Delivery of Hi-wall Split Air Conditioner of actual capacity 1 TR as detail specification.
Supply & Delivery of Hi-wall Split Air Conditioner of actual capacity 1.5 TR as detail specification.
Supply & Delivery of Hi-wall Split Air Conditioner of actual capacity 2 TR as detail specification.
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including S&F of necessary fixing arrangement for indoor and outdoor unit, duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. (i) Supply & Fixing of extra refrigerant pipe with insulation foam insulation (as requisite dia) [each mtr Refrigerent pipe will include cost of 1 metre liquid pipe line and 1 mtr gas pipe line of required dia].
Do----Do----Do (ii) 3 core 2.5 sq mm PVC insulated FRLS grade copper cable (make : Finolex/ Havells/Polycab)
Supply & Fixing of PVC drain pipe (make approved by EIC)
S&F MS platform with railling for maintenance of the outdoor units of AC machine fabricated from MS angle/flat etc including painting and as directed by EIC for above machines [design and drwaing to be approved by EIC before fabrication]
Supply & fixing of OLP 30 with current display, overload protection, timedelay between consicutive start AC machines starter on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F Modular board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
MISCELENEOUS Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS
Supply & Installation 15 Lt. capacity Gyser (Make-Reycold/AO Smith )
PART (E-7) : Electrical Installation of JUISTICE BUNGLOW DISTRIBUTION WIRING Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) as per GS 8 Mtr. [86 points x 15 units]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with Modular type plug socket & switch as per GS. On Board [14 points x 15 units]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. 13 mm dia 3 mm thick [450 mtr x 15 units]
19 mm dia 3 mm thick [260 mtr x 15 units]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. 3 x (1.5 sqmm) [210mtr. X 15units]
2x(2.5 sqmm)+1x(1.5 sqmm) [240 mtr. X 15units]
2x(4 sqmm)+1x(2.5 sqmm) [240 mtr. X 15units]
2x(6 sqmm)+1x(4 sqmm)
2x (10 sqmm) + 1x (6 sqmm) [100 mtr x 15 units]
Finishing of the PVC insulated wire ends by socketting with pin / ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 3 x (1.5 sqmm) [360 set X 15units]
2x(2.5 sqmm)+1x(1.5 sqmm) [480 setX 15units]
2x(4 sqmm)+1x (2.5 sqmm) [16 set X 15units]
2x (6 sqmm) + 1x (4 sqmm)
2x (10 sqmm) + 1x (6 sqmm) [12 set X 15units]
BDB, PDB, VTPN ETC. Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+16 Way [Legrand] [2 set x 15 units]
2+4 Way [2 set x 15 units]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 4Way [2set x 15 units]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 40 A DP [2 No x 15 units]
40 A FP [2 No x 15 units]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Up to 160A) [Make-Legrand] 4 way Enclosure (607913)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 SP [60 No x 15 units]
32 A TP MCB
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Make-Legrand). 80A
PLUGS & SOCKETS Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket with 6A Modular type switch as per GS ( For seperate plug) [14 No x 15 units]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switch, without plug to as per GS (For power plug) [12 No x 15 units]
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch, 16A Modular switch type MCB as per GS (For computer board) [2 No x 15 units]
Supply & Fixing 25 A Modular type Socket on 2 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board as per GS (For air-conditioning & Gyser) [16 No x 15 units]
FIXING OF LIGHT FITTINGS Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS. [20 No x 15 units]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS. [18 No x 15 units]
Fixing only LED Bracket / Mirror light fitting complete ith all accessories Directly on wall/ceiling as per GS. [NS] [16 No x 15 units]
SUPPLY OF LIGHT FITTINGS Supply of 4 Ft. 40 Watt single/twin florescent light fitting for indoor application,complete with all accessories & Lamps having following Model / Cat No.( Make -Philips) TMC 501P 1XT-LED 20W P3242) incl. 1xMAS LED TUBE 1200mm 18 W 865 T8I 2100lm (PC body) [18 No x 15 units]
Supply of LED Light Fittings for indoor application,complete with all accessories including lamps having catalogue and model as specified below.[NS ] Wall Light fittings with 1 No 6 Watt CDL LED Lamp ( 550 Lumen ) [ Philips Home Decor Cat No. 80926/67(QWG 307)] [10 No x 15 units]
Mirror Light fittings with 1 No 2.7 Watt LED Candle Lamp (230 Lumen ) [ Philips Home Decor Cat No. 32044/11 ] [6 No x 15 units]
FIXING OF FANS Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA as per GS. [20 No x 15 units]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board as per GS. [20 No x 15 units]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS. [20 No x 15 units]
Extra for supplying additional wire for down rod & painting the rod as per GS. [20 No x 15 units]
Fixing only exhaust fan after making holes in wall as per GS. [8 No x 15 units]
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS. [8 No x 15 units]
SUPPLY OF FANS Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves ) [ NS ] 1400 mm Sweep ( Aura Metallic ) [20 No x 15 units]
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) [ NS ] 9"( 230mm )Speed 1370 RPM [8 No x 15 units]
EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming as per GS. For Soft Soil [10 Cum x 15 units]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS. [2 Set x 15 units]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS. [0.5 Mtr. x 15 units]
Connecting the equipments to earth busbar including S & F 4 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. [5 Mtr. x 15 units]
Air Conditioning Machines Supply & Delivery of Hi-wall Split Air Conditioner of actual capacity 1 TR as detail specification.
Supply & Delivery of Hi-wall Split Air Conditioner of actual capacity 1.5 TR as detail specification.
Supply & Delivery of Hi-wall Split Air Conditioner of actual capacity 2 TR as detail specification.
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including S&F of necessary fixing arrangement for indoor and outdoor unit, duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. (i) Supply & Fixing of extra refrigerant pipe with insulation foam insulation (as requisite dia) [each mtr Refrigerent pipe will include cost of 1 metre liquid pipe line and 1 mtr gas pipe line of required dia].
Do----Do----Do (ii) 3 core 2.5 sq mm PVC insulated FRLS grade copper cable (make : Finolex/ Havells/Polycab)
Supply & Fixing of PVC drain pipe (make approved by EIC)
S&F MS platform with railling for maintenance of the outdoor units of AC machine fabricated from MS angle/flat etc including painting and as directed by EIC for above machines [design and drwaing to be approved by EIC before fabrication]
Supply & fixing of OLP 30 with current display, overload protection, timedelay between consicutive start AC machines starter on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F Modular board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
MISCELENEOUS Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS. [2 No x 15 units]
Supply & Installation 15 Lt. capacity Gyser (Make-Reycold/AO Smith )
PART (E-8) : TYPE III QTR ( 4 Units ) DISTRIBUTION WIRING Distn. wiring in 3X22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe with all accessories embedded in wall to light/fan/call bell points as per GS with following average run. 7 Mtr [ 136 points x 4 units ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point as per GS. On Board[ 32 points x 4 units ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. 13 mm dia 3 mm thick [480 mtr x 4 units]
19 mm dia 3 mm thick [ 6 (a)/ E- 3 ] [150 mtr x 4 units]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. 3 x (1.5 sqmm) [ 240 mtr. X 4units]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 240 mtr. X 4units]
2x (6 sqmm) + 1x (4 sqmm) [ 150 mtr. X 4 units]
Finishing of the PVC insulated wire ends by socketting with pin / ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 3 x (1.5 sqmm) [ 32 No. X 4 units]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 32 No X 4units]
2x (6 sqmm) + 1x (4 sqmm) [ 32 No X 4units]
BDB,PDB,VTPN ETC Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.[ Legrand ] 2+4 Way [1 set x 4 units ]
2+10 Way [ 8 set x 4 units ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 4Way [1 set x 4 units ]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Up to 160A) [Make-Legrand] 4 way Enclosure
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 32 A DP [ 8 No x 4 units ]
63 A FP [1 No x 4 units ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 [ 96 No x 4 units ]
32 A TP MCB
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Make-Legrand) (a) 80A
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall [ Make - Havells] [1 / D-1] 15/16A [1 No x 4 units]
30/32A [ 16 No x 4 units]
PLUGS & SOCKETS Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch on sheet metal switch board embedded in wall as per GS(For seperate plug) [ 16 No x 4 units]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch on sheet metal switch board embedded in wall as per GS(For power plug) [ 16 No x 4 units]
FIXING OF LIGHT FITTINGS Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS. . ][ 24 No x 4 units]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS ][ 48 No x 4 units]
SUPPLY OF LIGHT FITTINGS Supply of 4 Ft. 40 Watt single/twin florescent light fitting for indoor application,complete with all accessories & Lamps having following Model / Cat No.( Make -Philips). (a) TMC 501P 1XT-LED 20W P3242) incl. 1xMAS LED TUBE 1200mm 18 W 865 T8I 2100lm (PC body)
FIXING OF FANS Fixing only exhaust fan after making holes in wall as per GS (9") [ 8 No x 4 units]
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS (9") [ 8 No x 4 units]
SUPPLY OF FANS Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) 9"( 230mm ) Speed 1370 RPM[ NS ][ 8 No x 4 units]
MISCELENEOUS Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS [ 8 No x 4 units]
EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming as per GS For Soft Soil [ 5 cuMtr x 4 units]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2 set x 4 units]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [0.5 Mtr x 4units]
Connecting the equipments to earth busbar including S & F 4 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages [ 10 Mtr x 4 units]
PART (E-9) : TYPE IV QTR. (5 Units ) DISTRIBUTION WIRING Distn. wiring in 3X22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe with all accessories embedded in wall to light/fan/call bell points as per GS with following average run. 7 Mtr [ 234 points x 5 units ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point as per GS. On Board [ 48 points x 5 units ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. 13 mm dia 3 mm thick [960 mtr x 5 units]
19 mm dia 3 mm thick [280 mtr x 5 units]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. 3 x (1.5 sqmm) [ 480 mtr. X 5units]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 480 mtr. X 5units]
2x (6 sqmm) + 1x (4 sqmm) [ 280 mtr. X 5units]
Finishing of the PVC insulated wire ends by socketting with pin / ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 3 x (1.5 sqmm) [ 64 No. X 5units]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 64 No X 5units]
2x (6 sqmm) + 1x (4 sqmm) [ 64 No X 5units]
BDB,PDB,VTPN ETC Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.[ Legrand ] 2+4 Way [1 set x 5 units ]
2+10 Way [16 set x 5 units ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 8Way [2 set x 5 units ]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Up to 160A) [Make-Legrand] 4 way Enclosure
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 32 A DP [16 No x 5 units ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Make-Legrand) (a) 125A
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 [208 No x 5 units ]
63 A TP MCB [ 2x 5 Units ]
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall [ Make - Havells] [1 / D-1] 15/16A [1 No x 5 units]
30/32A [32 No x 5 units]
PLUGS & SOCKETS Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch on sheet metal switch board embedded in wall as per GS(For seperate plug) [ 32 No x 5 units]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch on sheet metal switch board embedded in wall as per GS(For power plug) [ 32 No x 5 units]
FIXING OF LIGHT FITTINGS Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS. . [ 48 No x 5 units]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS [ 96 No x 5 units]
SUPPLY OF LIGHT FITTINGS Supply of 4 Ft. 40 Watt single/twin florescent light fitting for indoor application,complete with all accessories & Lamps having following Model / Cat No.( Make -Philips). (a)TMC 501P 1XT-LED 20W P3242) incl. 1xMAS LED TUBE 1200mm 18 W 865 T8I 2100lm (PC body) [ 48 No x 5 units]
FIXING OF FANS Fixing only exhaust fan after making holes in wall as per GS (9") [ 16 No x 5 units]
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS (9") [ 16 No x 5 units]
SUPPLY OF FANS Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) 9"( 230mm ) Speed 1370 RPM[ NS ][ 16 No x 5 units]
MISCELENEOUS Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS [ 20 [ 16 No x 5 units]
EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming as per GS For Soft Soil [10 cuMtr x 5units]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS 2 set x 5 units]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [0.5 Mtr x 5units]
Connecting the equipments to earth busbar including S & F 4 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages [ 20 Mtr x 5units]
PART (E-10) : COMPOUND LIGHTING SYSTEM SITC of Double door outdoor type Distribution Feeder Pillar box conforming to Indian Standard IS : 5039-1969 with latest amendments,suitable for use on 3 phase 4 wire, 400/440 Volts 50 Cycles A.C. as per detailed specification
Supply & Delivery of Hot Dip Galvanised (as per IS:2629 / IS 2633 / IS 4759 and with its latest amendment ) Octagonal Pole made of HT steel ( sheet thickness -3mm ) conforming to grade as per detailed specification
Errection of the following Octagonal pole by designing and Casting RCC ( M 20 ) foundation of suitable size as per detailed specification.
SITC of single dip galvanized steel overhang bracket ( Swan Neck Type ) at the top of the pole having 1 M length complete with all fixing arrangements as required including painting Single Arm
Double Arm
Tripple Arm
Four Arm
SITC of road lighting luminaire ( IP 65 ) with peanut lens and high power LED and to ensure uniform distribution, higher spacing between poles and maintenance free system and s suitable for use with 230Volt 50Hz AC supply etc as required. ( Make - Philips Model No. BRP410 LED 110/equivalent product of Crompton/Wipro in all respect )
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size.[ Make Nicco / Gloster/Havells/ Polycab/Crystal] 4 Core10 Sq. mm
4 Core16 Sq. mm
Laying of one No. cable in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Laying of one No. cable through PVC/Alkathene /GI pipe as per direction of the EIC.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 Core10 Sq. mm
4 Core16 Sq. mm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc.and making connection to switch, BDB and BBC etc. 4 Core10 Sq. mm
4 Core16 Sq. mm
S & L of 1.1 KV grade 3 X 1.5 Sq mm FR single core multi stranded copper wire for connection from loop box to fittings through 13 mm dia polythene pipe.
Finishing of the PVC insulated wire(3 X 1.5sqmm) ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
S & F of medium gauge G.I pipe (ISI medium) having the following diameter [50 mm Diameter] for protection of cable with necessary fitting and jointing materials as required.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as below (ISI medium G.I pipe)
PART (E-11) : SUB STATION of RESIDENTIAL PORTION SITC OF 11KV VCB PANEL & TRANSFORMERS Supply & Delivery Indoor-type, floor mounted,metal clad, single tier, fully compartmentalized,free standing, 11 kV VCB Panel with 3 Nos VCBs (1 Incomer + 2 Outgoing), totally enclosed and fully interlocked , horizontal drawout, horizontal / vertical isolation type breaker as per IS 13188, as ammended upto date and as per detail specification attached ( uploaded in the specification section) , suitable for use on 11 KV, 3 Phase,50 Hz AC supply to energise Two nos 500 KVA Oil Type Transformers. [ Make : ABB / Siemens / CGL].
Installation & commissioning of the above 11 kV VCB Panel with P.T & all the accessories, incl. carriage, by placing in position, assembling, lining up, levelling and checking all instruments, relays, correctly set according to requirement.
Supply & Delivery of Oil Type indoor type corrugated tank design 500 KVA,11KV/433V , 3 Phase,50Hz, Dyn11, KNAN type sealed type copper wound Transformer with all accessories I/C first filling of filtered dehydrated K-Class natural ester oil bio transol as per IS 16659 as per detailed specification attached.
Installation & commissioning of 11 KV/ 415 volt, two 500 KVA distribution transformer incl. carriage to the substation building within a lead of 30mtr by placing in position and fixing after leveling fitting all components, connecting, checking & set of all instrument, relays according to requirement as instructed by the EIC incl. S&F base channels etc.
SITC of floor mounted Indoor type extensible cubical MV switchboard,fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel,front and back openable, hinged, single shuttered, with incoming ACBs & Outgoing MCBS and all accessories as per size, design & drawing to be approved by EIC and conforming to IS with latest modification and as per detail specification attached ( uploaded in the specification section)[LT MAIN PANEL IN THE SUBSTATION of Residential portion]
Making testing arrangement and submitting the test report for high voltage testing of specified voltage incl. checking & testing of all HT / LT equipments by authorized firm of Directorate of Electricity & commissioning the installation after obtaining the Approval of Directorate of Electricity.The scope shall be also included the necessary approval from Authority also.
Supply & fixing 75x45 mm "C" channel having length of 2 mtr. each channel incl. nuts, bolts and washer etc.
AUTOMATIC POWER FACTOR CORRECTION PANEL Supply & delivery, Installation, Testing & Commissioning of AUTOMATIC POWER FACTOR CORRECTION PANEL ( must be designed for 1600 KVA) and conforming to IS with latest modification to be integrated with LT Panel at HT Substation Building. The APFC Pannel is to be desgned by the bidder. HT/ LT CABLING IN SUBSTATION Supplying of 11KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable conforming to IS 7098, of earthed system of following size.[ From Supplier HT Gear to Consumer HT Gear and to Transformer]. [ Make : Nicco / Gloster/Polycab/Havells/Crystal ] 3 Core x 240 Sq.mm
Making heatshrinkable joints indoor type to the ends of the following XLPE HT cable at the transformer end as well as at the VCB ends supplying with necy. jointing kits, sockets, sleeves, anti-corrossive paste, wires, solders, jointing compounds, rubber sheets etc. incl. supplying of necy. tools & tackeles for crimping the end sockets, soldering irons & making of glands at the both end of the cable as per directions of EIC a) 3 Core x 240 Sq.mm
Laying of 1 No. 11KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable confirming to IS 7098, of earthed system of following size in the existing Masonary Open Duct as required. a) 3 core 240 sqmm 11KV XLPE HT cable
Supplying of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade conforming to IS 7098 of following size in the existing Masonary Open Duct. [ From TR & DG set to main panel].[ Make : Nicco / Gloster/Polycab / Havells ] a) 4Core x 400 sq.mm
b) 4Core x 300 sq.mm
Laying of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing Masonary Open Duct a) 4Core x 400 sq.mm
b) 4Core x 300 sq.mm
Supplying and making end termination with Brass compression gland and aluminium lugs for the following sizes of PVC insulated and PVC sheathed aluminium conductor cable of 1.1 KV Grade as required a) 4 Core x 400 sq.mm.
b) 4Core x 300 sq.mm
Supply & Drawing 1.1 KV Grade 7 Core 1.5 sq.mm PVC Armoured Copper Cable from Transformer WT relay to VCB WT relay for Power & Control Supply as per direction of EIC
EARTHING S& laying 240 sq. mm. single core multistrand PVC insulated flexible Cu wire in suitable size of PVC flexible pipe (reinforced) from nutral earth busbar to transformer point as required (for Transformer /Generator neutral earthing) including Socketing both sides by Cu Socket.
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level as per detail specification attached ( uploaded in the specification section) [ FOR TRANSFORMER NEUTRAL AND DG SET EARTHING ]
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Supply & fixing earth busbar of galvanized (Hot dip) MS flat 65 mm x 8 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Insulating the 65 x 8 mm M.S. flat incl. S&F black heat shrink PVC sleeves etc. The PVC tube sleeve to be inserted on the GI flat and heat shrinked by heating apparatus by skilled technician carefully without damaging the PVC sleeve as per direction of the EIC (for transformer neutral earth bus bar).
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
S & F special type earth electrode clamp made of GI flat with nuts, bolts,, washer etc. suitable for 80 mm dia GI pipe earth.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 80mm dia
SAFETY EQUIPMENT Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscription in signal red colour on front side as required. a) High Voltage - size 250mm x 200mm
b) Medium Voltage - size 200mm x 150mm
Providing and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 15222-2002 and cylinders fully charged of following capacity(4.5 Kg ) [Make - Fire Shield/ Ceasefire]
Supply and fixing of foam fire extinguishers conforming to IS 4989-2006, Portable type 9 lit capacity hanged on wall with bracket complete as required. [Make - Fire Shield/ Ceasefire]
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (approx. Front area 1.20 sq.mt.)
Providing of set of 4 nos. 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame with bracket and suitable base of appropriate size & capacity I/c filling sand etc.
Providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 13115-1991.
Supply and fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as reqd. (approximate front area 1.20 sq.metre).
Providing of rubber mat 2 mtrs Length x 1 m. wide and 12mm thick to withstand 15 KV dielectric strength as per IS 15652-2006.
Providing of rubber mat 2 mtrs Length x 1 m. wide and 6mm thick to with stand 3.3 KV dielectric strength as per IS 15652-2006.
S/F of 860 mm wide and 8 mm thick M.S checker plate including painting for covering the trench.
LT CABLING FROM SUBSTATION Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size. [ Make Nicco / Fort Gloster/Polycab/Havells] 4Core 25 Sq. mm [ MAIN LT PANEL TO SUBSTATION TPNDB]
Supplying of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade conforming to IS 7098 of following size in the existing Masonary Open Duct. [ From main panel to Load].[ Make : Nicco / Gloster/ Polycab/Havells/Crystal ] a) 4Core x 400 sq.mm
b) 4Core x 240 sq.mm
c) 4Core x 185 sq.mm
d) 4Core x 95 sq.mm
d) 4Core x 35 sq.mm [ from feeder piller to Chief Justice Bunglow & Justice Bunglow & Type 3 Qtr.]
Laying of cable as below, in UG Tranch as per GS a) 4Core x 400 sq.mm
b) 4Core x 240 sq.mm
c) 4Core x 185 sq.mm
d) 4Core x 95 sq.mm
d) 4Core x 35 sq.mm [ from feeder piller to Chief Justice Bunglow & Justice Bunglow & Type 3 Qtr.]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish including removing the rubbish. From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below including finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. a) 4Core 35 Sq. mm
b) 4Core x 400 sq.mm
c) 4Core x 240 sq.mm
d) 4Core x 185 sq.mm
e) 4Core x 95 sq.mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 50mm dia
Design, Manufacture, testing, supply, installation and commissioning of Double door outdoor type Distribution Feeder Pillar box conforming to Indian Standard IS : 5039-1969 with latest amendments,suitable for use on 3 phase 4 wire, 400/440 Volts 50 Cycles A.C. Supply and shall be suitable for short circuit fault of 31 MVA at 415 Volts, fabricated as per size, design & drawing to be approved by EIC. The Enclosure shall provide Degree of protection IP -54 in accordance with IS : 2147 -1962 with its latest ammendmentThe feeder pillar box will be fabricated by CPRI approved fabricator as per detail specification attached ( uploaded in the specification section).
SITC of DG SET Supply of DG Set Supply , delivery at site on foundation , testing & commissioning of 500KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, separate AMF panel, with inbuilt bypass base frame fuel tank , CPCB-II approved Engine & Acoustic Enclosure (As per details specification)
INSTALLATION of DG S &F MS angle iron structure made of (80x80x6) mm/(50x50x6) mm MS angle to support 250 mm dia MS pipe &Fuel tank support for 500KVA DG set incl. painting as per per GS.
Supply & fixing of exhaust gas piping of suitable dia welded black 250 mm dia MS class B pipe incl. all necessary bend, tee, sockets, plug, supports and clamps anti-vibration mounting insulation of exhaust system with 50 mm thick mineral wool covered with wire mesh and aluminium cladding ( from DG sets to top of the building plus 3mtr or as per CPCB) for 500 KVA DG set as per direction of EIC.
Painting the 250 mm dia MS black pipe by Aluminium paint of two coat over the RO primer (approved make)
S&F rain protection canopy for 250 mm exhaust pipe
Hire charges for scaffolding by bamboo required rope of square type arrangement for smooth working & carriage of MS black pipe by vertical run & dismantling at the end of work.
S &D of HSD for testing & immediate run of DG set incl. carrying charge
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Extra for providing masonry enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement mortar (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supply and laying of 10core 2.5sqmm copper Armoured control cable,after cutting floor/pavent/wall/and making holes incl. Embedding the cable at an average depth as 75mm and mending good the damages to original finish incl. Removing the rubbish
Supply and laying of 2core 6sqmm copper Armoured control cable, after cutting floor/pavent/wall/and making holes incl. Embedding the cable at an average depth as 75mm and mending good the damages to original finish incl. Removing the rubbish
Supply & Laying of single core 240 Sqmm Copper Aurmoured cable, (Havells/ Gloster/ Polycab/RRKable/Crystal) after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as 100mm and mending good the damages to original finish incl. removing the rubbish.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of XLPE/PVC armoured cable as below. Single core 240 Sqmm Armoured cable
10 core 2.5Sqmm Armoured cable
2 core 6Sqmm Armoured cable
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying dowells make sockets, tapes. Single core 240 Sqmm copper wire by dowels make heavy duty long barrel Copper socket.
10 core 2.5Sqmm Armoured cable
2 core 6Sqmm Armoured cable
S&F 2 Kg capacity ABC type Gas pressure (DCP) fire extinguisher on wall by suitable size of iron bracket (Make - Fire Shield)
S&F 9 ltr. Capacity round fire bucket with iron hook and duly filled up by sand.
DISTRIBUTION WIRING Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 6Way
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+8 Way[ Legrand ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 32 A DP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 SP
Distn. wiring in 3X22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Finolex/ Polycab/ Havells/ RR Kabel] in 19 mm bore, 3 mm thick polythen pipe with all accessories embedded in wall to light / fan / call bell points as per GS with following average run [ As per approved list of Material ] 10 Mtr
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Finolex/ Polycab/ Havells/ RR Kabel] in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point as per GS.[ As per approved list of Material ] On Board
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.[ As per approved list of Material ] 19 mm dia 3 mm thick
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Finolex/ Polycab/ Havells/ RR Kabel] of the following sizes in the prelaid polythene pipe as per GS.[ As per approved list of Material ] 2x(2.5 sqmm)+1x(1.5 sqmm)[ for 16 A Power plug, Computer Board ] [ 1(s) / E-9 ]
2x (6 sqmm) + 1x (4 sqmm) [ For 32 A Outlet ] [ 1 (y) / E- 9 ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc including supplying sockets, tapes. [ 9 / F 5 ] 2x(2.5 sqmm)+1x(1.5 sqmm)
2x (6 sqmm) + 1x (4 sqmm)
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS 150 x 100 x 65
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch on sheet metal switch board embedded in wall as per GS
Supply & Fixing 240 V, 20A Piano key type switch on sheet metal switch board embedded in wall as per GS incl. S&F of Box top cover etc.
Supply & Fixing Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switch board as per GS
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification as per GS.
Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves) a. 1200 mm Sweep ( Crompton Standard Hi Speed/ Orient High Speed )
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC Heavy Duty) [ NS ] 12"( 300mm ) Speed 920 RPM
Fixing only exhaust fan after making holes in wall as per GS (12")
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS (12")
Supply & Fixing Timer for controlling of exhaust fan fixed on wall in MS Box with top cover (L&T Micon225/equivalent Legrand).
Supply & Fixing of LED light fittings (Make Philips/Crompton) a) 1x 18W TMC 501 TLED with 1 no 18W Master LED Lamp (Make Philips/Crompton)
b) 15W LED bulb (Philips/Crompton)
PART (E-12) : SITC of LIFT SITC of Automatic Lift (as per manufacturer design & as per detailed specification conforming to IS ) and putting into operation after final testing in the existing lift shaft complete with all accessories and repairing the damage wall / floor if any etc to complete as reqd. (Details specification is given in Specification Sheet) 6 Passenger (408 Kg) passenger lift , Gear less, MRL, for G+1 , Landing - 2, Travel approx 6.6m, Shaft Dimension : 1525mm x 1600mm
10 Passenger (680 Kg) passenger lift , Gear less, MRL, for G+1 , Landing - 2, Travel approx 8.1m (for Auditorium), Shaft Dimension : 1900mm x 2100mm
10 Passenger (680 Kg) passenger lift , Gear less, MRL, for G+4 , Landing - 5, Travel approx 21m, Shaft Dimension : 1900mm x 2100mm
13 Passenger (884 Kg) passenger lift , Gear less, MRL, for G+4 , Landing - 5, Travel approx 21m, Shaft Dimension : 1900mm x 2500mm
16 Passenger (1088 Kg) passenger lift , Gear less, MRL, for G+4 , Landing - 5, Travel approx 21m, Shaft Dimension : 2500mm x 2100mm
15 Passenger ( 1020 Kg) Stretcher lift , Gear less, MRL, for G+4 , Landing - 5, Travel approx 21m, Shaft Dimension : 1800mm x 3000mm
PART (E-13) : SITC of HVAC IN THE COURT BUILDING Supply, Positioning, Starting, Testing & Commsioning of AHRI / Eurovent certified Water Cooled Screw Chiller package of actual capacity 300TR +/- 5% and suitable for HFC 134A refrigerant as per detailed specification. ( 3 Working + 1 Standby)
SITC of Chilled Water Line valves & accessories as below and as per detailed specification. 200 mm Dia CI Body Butterfly Valves(PN-16 Rated)
150 mm Dia CI Body Butterfly Valves(PN-16 Rated)
200 mm Dia CI Body Balancing Valves(PN-16 Rated)
150 mm Dia CI Body Balancing Valves(PN-16 Rated)
200 mm Dia Flexible Bellows
150 mm Dia Flexible Bellows
4" Dial type Bourdon pressure gauge with isolating valves
V Groove thermometer refiled with blue color murcury.
Water flow switch for chilled & condenser water conn.
150 mm Dia CI Body SS Plate Check Valves
150 mm Dia Y strainer with SS screen
4" Dial type Bourdon pressure gauge with isolating valves
150 mm Dia Flexible Bellows
SITC of Condenser Water Pumps Set as per detailed Specification ( 3 W + 1 S )
SITC of valves & accessories as below and as per detailed specification for condenser piptng. 200 mm Dia CI Body Butterfly Valves(PN-16 Rated)
200 mm Dia CI Body SS Plate Check Valves
200 mm Dia Y strainer with SS screen
4" Dial type Bourdon pressure gauge with isolating valves
200 mm Dia Flexible Bellows
SITC of Primary Chilled Water Pumps Set as per detailed specification.( 3 W + 1 S )
SITC of Secondary Chilled Water Pumps Set as per detailed specification (3W+1S)
SITC of Variable Speed Pumping System for Secondary Chilled Water Pumps as per detailed specification.
SITC OF FRP Induced Draft Cooling Toweras per detailed specification for 300TR Chiller ( 3 W + 1 S )
SITC of valves & accessories as below and as per detailed specification for Cooling tower. 300 mm Dia CI Body Butterfly Valves(PN-16 Rated)
200 mm Dia CI Body Butterfly Valves(PN-16 Rated)
100 mm Dia CI Body Butterfly Valves(PN-16 Rated)
65 mm Dia Butterfly valve CI Body Butterfly Valves(PN-16 Rated)
300 mm Dia Pot strainer
SITC of Pressurised Expansion Tank (Chilled Water) as per detailed specification
SITC of Air Handling Unit as per detailed specification having the following CFM. Ceiling Suspended AHU (6RD Coil), 7600 CFM, 40 mm static pressure.(17TR)
Ceiling Suspended AHU (6RD Coil), 7000 CFM, 40 mm static pressure.(16TR)
Ceiling Suspended AHU (6RD Coil), 6500 CFM, 40 mm static pressure.(15TR)
Ceiling Suspended AHU (6RD Coil), 5800 CFM, 40 mm static pressure.(13TR)
Ceiling Suspended AHU (6RD Coil), 5500 CFM, 40 mm static pressure.(12TR)
Ceiling Suspended AHU (6RD Coil), 4800 CFM, 40 mm static pressure.(11TR)
Ceiling Suspended AHU (6RD Coil), 4000 CFM, 40 mm static pressure.(10TR)
Ceiling Suspended AHU (6RD Coil), 3600 CFM, 40 mm static pressure.(8 TR)
Ceiling Suspended AHU (6RD Coil), 3200 CFM, 40 mm static pressure.(7 TR)
Ceiling Suspended AHU (6RD Coil), 2700 CFM, 40 mm static pressure.(6 TR)
Ceiling Suspended AHU (6RD Coil), 2200 CFM, 40 mm static pressure.(5 TR)
Ceiling Suspended AHU (6RD Coil), 1600 CFM, 40 mm static pressure.(4 TR)
SITC of Valve & Accessories for the above AHU as per detaiied specification and as below. 50 NB CI Body Butterfly Valves(PN-16 Rated)
40 NB Ball Valve
40 NB Manual Pressure Independent Control Valve
32 NB Manual Pressure Independent Control Valve
32 NB Manual Pressure Independent Control Valve
50 NB Y Strainer
40 NB Y Strainer
Pressure & Temperature test points
Auto Air Vent 10 mm
Supply, installation, testing and commissioning of Hi Wall Units along with Chilled Water Valve package consisting of Ball valve with and without strainer, 2 way control valve and all other accessories required shall be part of scope. MS to Copper connectors required to connect from the main CHW MS pipeline before connecting to unit. Dgital wireless remote shall be part of scope. 3 TR
SITC of Hiwall DX-split AC along with all other accessories. 2 TR
SITC of Treated Fresh AirUnit as per detailed specification having the following CFM Ceiling Suspended TFA (8RD Coil), 3300 CFM, 40 mm static pressure.(22 TR)
Ceiling Suspended TFA (8RD Coil), 2700 CFM, 40 mm static pressure.(18 TR)
Ceiling Suspended TFA (8RD Coil), 2600 CFM, 40 mm static pressure.(17 TR)
Ceiling Suspended TFA (8RD Coil), 2300 CFM, 40 mm static pressure.(15 TR)
Ceiling Suspended TFA (8RD Coil), 2100 CFM, 40 mm static pressure.(14 TR)
Ceiling Suspended TFA (8RD Coil), 2300 CFM, 40 mm static pressure.(15 TR)
Ceiling Suspended TFA (8RD Coil), 1500 CFM, 40 mm static pressure.(11 TR)
Ceiling Suspended TFA (8RD Coil), 1000 CFM, 40 mm static pressure.(6.5 TR)
Ceiling Suspended TFA (8RD Coil), 1400 CFM, 40 mm static pressure.(9 TR)
SITC of Valve & Accessories for the above TFA as per detaiied specification and as below. 65 NB CI Body Butterfly Valves(PN-16 Rated)
50 NB CI Body Butterfly Valves(PN-16 Rated)
50 NB Manual Pressure Independent Control Valve
40 NB Manual Pressure Independent Control Valve
32 NB Manual Pressure Independent Control Valve
32 NB Manual Pressure Independent Control Valve
65 NB Y Strainer
50 NB Y Strainer
40 NB Y Strainer
Pressure & Temperature test points
Auto Air Vent 10 mm
Supplying, installing, testing and commissioning of direct driven PROPELLER FANS for exhaust air of Toilets in court building. 1000 CFM
SITC of ERW pipe for chilled water circuit as per detailed specification of following sizes and quantities: 250 MM NB (6.35 mm thick)
SITC of ERW pipe for chilled water circuit as per detailed specification of following sizes and quantities outside the building burried in ground. 250 mm dia
SITC of pipe for condenser water circuit as per detailed specification of following sizes and quantities: 300 MM NB (7 mm thick)
200 MM NB (6.35 mm thick)
SITC of pipe for condensate drain as per detailed specification of following sizes. 25 mm NB
SITC of GI B class pipe for cooling tower make up water connection. 65 mm NB
SITC of Valves for Risers & floor tap off as below and as per detailed specification. Butterfly Valves CI Body Butterfly Valves(PN-16 Rated). 250 MM NB
Balancing Valves CI Body Butterfly Valves(PN-16 Rated) 150 MM NB
SITC & Designing of supply air duct along with the accessories as per detailed specification of following gauges. 24 SWG thick
22 SWG thick
20 SWG Thick
SITC of supply air diffusers with accessories as per detailed specification.
SITC of return air diffusers with accessories as per detailed specification.
SITC of supply air grills with accessories as per detailed specification.
SITC of return air grills with accessories as per detailed specification.
SITC of Motorized Fire & smoke damper with actuator and panel asper detailed specification. Fire Damper
Actuator with Panel
SITC of opposed blade GI Duct Damper with accessories as per detailed specification
SITC of fresh air louver with accessories as per detailed specification
SITC of duct Acoustic Insulation with accessories as per detailed specification.
SITC of duct thermal Insulation with accessories as per detailed specification. 19 mm thick
SITC of thermal Insulation on chilled water pipe with accessories as per detailed specification of following sizes. 250 MM NB (50 mm Thcik)
150 MM NB (44 mm thick)
125 MM NB (44 mm thick)
100 MM NB (44 mm thick)
80 MM NB (44 mm thick)
65 MM NB (38 mm thick)
50 MM NB (38 mm thick)
40 MM NB (38 mm thick)
32 MM NB (38 mm thick)
25 MM NB (38 mm thick)
SITC of LT Cubicle type Starter Panel as per detailed specification for the following AHU. Ceiling Suspended AHU (6RD Coil), 7600 CFM, 40 mm static pressure.(17TR)
Ceiling Suspended AHU (6RD Coil), 7000 CFM, 40 mm static pressure.(16TR)
Ceiling Suspended AHU (6RD Coil), 6500 CFM, 40 mm static pressure.(15TR)
Ceiling Suspended AHU (6RD Coil), 5800 CFM, 40 mm static pressure.(13TR)
Ceiling Suspended AHU (6RD Coil), 5500 CFM, 40 mm static pressure.(12TR)
Ceiling Suspended AHU (6RD Coil), 4800 CFM, 40 mm static pressure.(11TR)
Ceiling Suspended AHU (6RD Coil), 4000 CFM, 40 mm static pressure.(10TR)
Ceiling Suspended AHU (6RD Coil), 3600 CFM, 40 mm static pressure.(8 TR)
Ceiling Suspended AHU (6RD Coil), 3200 CFM, 40 mm static pressure.(7 TR)
Ceiling Suspended AHU (6RD Coil), 2700 CFM, 40 mm static pressure.(6 TR)
Ceiling Suspended AHU (6RD Coil), 2200 CFM, 40 mm static pressure.(5 TR)
Ceiling Suspended AHU (6RD Coil), 1600 CFM, 40 mm static pressure.(4 TR)
SITC of LT Cubicle type Starter Panel as per detailed specification for the following Treated Fresh Air Unit. Ceiling Suspended TFA (8RD Coil), 3300 CFM, 40 mm static pressure.(22 TR)
Ceiling Suspended TFA (8RD Coil), 2700 CFM, 40 mm static pressure.(18 TR)
Ceiling Suspended TFA (8RD Coil), 2600 CFM, 40 mm static pressure.(17 TR)
Ceiling Suspended TFA (8RD Coil), 2300 CFM, 40 mm static pressure.(15 TR)
Ceiling Suspended TFA (8RD Coil), 2100 CFM, 40 mm static pressure.(14 TR)
Ceiling Suspended TFA (8RD Coil), 2300 CFM, 40 mm static pressure.(15 TR)
Ceiling Suspended TFA (8RD Coil), 1500 CFM, 40 mm static pressure.(11 TR)
Ceiling Suspended TFA (8RD Coil), 1000 CFM, 40 mm static pressure.(6.5 TR)
Ceiling Suspended TFA (8RD Coil), 1400 CFM, 40 mm static pressure.(9 TR)
Supply, laying and termination of 1.1 KV Gr. PVC/XLPE insulated, PVC- Sheathed, Aluminium Conductor armoured cables as per IS:1554. Control Cables shall be multi-core PVC -insulated PVC sheathed Copper conductor. 4 Core 2X240 sqmm XLPE A/Al Cable
4 Core 50 Sqm XLPE A/Al Cable
3 Core 25 sqmm XLPE A/AI Cable
3 Core 10 sqmm XLPE A/AI Cable
3 Core 4 sqmm XLPE A/AI Cable
3 Core 1.5 sqmm Cu Control Cable.
2 Core 1.5 sqmm Cu Control Cable.
SITC of GI perporated cable tray of requisite specification as per IS of following sizes. 400 MM width (1.6 mm thick)
300 MM width (1.6 mm thick)
200 Mm Width (1.6 mm thick)
100 MM width (1.6 mm thick)
SITC of Earthing the installation as per IS with the following size GI Flat & Wire. 40 X 6 GI FLAT TAPE
25 X 3 GI FLAT TAPE
8 SWG GI WIRE
PART (E-14) : SITC of HVAC IN THE AUDITORIUM Supply, installation, testing and commissioning of Air Cooled water Chilling unit of 30 TR actual capacity as per detailed specification. (2 Working + 1 Standby)
SITC of Chilled Water Line valves & accessories as per detailed specification for the following items. 80 mm Dia Butterfly Valves
80 mm Dia Balancing Valves
80 mm Dia Flexible Bellows
4" Dial type Bourdon pressure gauge with isolating valves
V Groove thermometer refiled with blue color murcury.
Water flow switch for chilled water conn.
80 mm Dia Check Valves
80 mm Dia Y strainer with SS screen
65 NB Manual Pressure Independent Balancing Valve
Auto Air Vent 10 mm
SITC of chilled water centrifugal pump sets for chilled water recirculation as per detailed specification. (2W+1S)
SITC of chilled water Expansion Tank as per detailed specification .
SITC of AHU as per detailed specification y of following capacities. Floor Mounted AHU (6RD Coil), 9000 CFM, 80 mm static pressure.(30TR)
SITC of Hiwall DX-split AC along with all other accessories. 2 TR
Supplying, installing, testing and commissioning of direct driven PROPELLER FANS for exhaust air of Toilets in Auditorium 550 CFM
SITC of pipe for chilled water circuit as per detailed specification of following sizes and quantities: 100 MM NB
SITC of chilled water piping Outside the building burried in ground as per detailed specification of following size. 100 mm dia.
SITC of condensate drain pipe as per detailed specification of following size. 25 mm NB
SITC of supply air duct along with necessary accessories as per detailed specification of following gauges. 24 SWG thick
22 SWG thick
SITC supply air eye ball diffusers as per detailed specification. 315 mm dia.
SITC of supply air grilles as per detailed specification
SITC of return air grilles as per detailed specification.
SITC of Fire & smoke damper with actuator and pane as per detailed specification. Fire Damper
Actuator with Panel
SITC of Opposed blade GI Duct Damper complete with other accessories as per detailed specification .
SITC of fresh air louver as per detailed specification.
SITC of Duct Acoustic Insulation as per detailed specification ( 15 mm thick )
SITC of Duct Thermal Insulation as per detailed specification. 19 mm thick
SITC of of thermer insulation on chilled water pipe as per detailed specification of following size. 100 MM NB (44 mm thick)
80 MM NB (44 mm thick)
SITC of LT Cubicle type Starter Panel as per detailed specification for the following AHU. Floor Mounted AHU (6RD Coil), 9000 CFM, 80 mm static pressure.(30TR)
Supply, laying and termination of 1.1 KV Gr. PVC/XLPE insulated, PVC- Sheathed, Aluminium Conductor armoured cables as per IS:1554. Control Cables shall be multi-core PVC -insulated PVC sheathed Copper conductor. a) 3.5 Core 95 sqmm XLPE A/Al Cable
c) 3 Core 4 sqmm XLPE A/AI Cable
f) 2 Core 1.5 sqmm Cu Control Cable.
SITC of GI perporated cable tray of requisite specification as per IS of following sizes. 200 MM width
100 MM width
SITC of Earthing the installation as per IS with the following size GI Flat & Wire. 25 X 3 GI FLAT TAPE
8 SWG GI WIRE
PART (E-15) : FIRE DETECTION SYSTEM Supply, Installation,Testing & Commisioning of Microprocessor based Intelligent, addressable 24 Loops fire alarm control panel having expandable features ( VDS / UL / FM / ULC approved ) fully networkable with each loop capable of taking minimum 120 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type.The panel shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards.
The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emargency condition, with integral battery charger complete as required. The panel shall have extra loop card to serve as stand by in case of burntout or malfunctioning of any operating loop cards. The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system and BMS( RS 485 )The system must be preloaded with licenced software.( Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls ).
SITC of Repeater Panel ( VDS / UL / FM / ULC approved )which will act as an add-on device for remote display of FACP status information of the FDA operating front related to the detectors and decetors zones.Event messages are displayed via LED collective indicators and on the 2-Line LCD display with the associated detecors zone number and a programmable additional text. Each message is signalled via the built-in buzzer. The buzzer can be acknowledged by pressing a button. Upto 31 LCD indicator panel can be operated on as RS 485 bus. (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls ).
Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved ) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost).(Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls )
Supplying, installation, testing and commissioning of Addressable Heat Detector (Fixed temperature cum rate of rise) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost)...(Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Contros )
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo/ Morley / System Sensor / Johnson Controls ).
Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls ).
Supply, Installation, Testing & Commissioning of Addressable transponder/ Monitor Modules ( VDS / UL / FM / ULC approved ) for monitoring flow switches/Fire exit doors / AHU / Lift etc complete as required. ( Approved Make: (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls ).
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc.( Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls ).
Supplying, installation, testing and commissioning of conventional addressable Beam detector with mounting base alongwith input module( VDS / UL / FM / ULC approved) ( Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo/ Morley / System Sensor / Johnson Controls ).
Supply, Installation, Testing & Commissioning of Addressable Relay Modules (VDS / UL & FM approved) for switching / integration of Lift / AHU etc complete as required.
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make.Finolex / Havells/Polycab ) within the 20 mm NB PVC rigid conduit pipe incl. S &F 20 mm dia PVC rigid conduit pipe (Make: Precisson-Medium) on the surface of the wall.
NOTE : 1. The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation. TESTS:1.The system shall be tested and commissioned by a qualified competent,trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done.
PART (E-16) : SITC of STAGE LIGHTING & P.A SYSTEM AT AUDITORIUM Stage Light:- Supply, fitting and fixing of 1000 watt Plano convex spot light with 150 mm dia lens, 1000 watts Bi-pin halogen lamp CP - 70, Spherical anodized finish reflector including lamp, holder, C-clamp for hanging light fittings in all complete. Make : Canara Lights/ Modern Stage Services/ DTS/ Sholite.
Supply, fitting and fixing of 1000 W PAR light fittings made of CRC sheet metal with matt black colour paint finish with 1000Watts 240V sealed wide beam lamp, barndoor arrangements including lamp, holder, C-clamp for hanging light fittings in all complete. Make :Canara Lights/ Modern Stage Services/ DTS/ Sholite.
Supply, fitting and fixing of 1000 W PAR light fittings made of CRC sheet metal with matt black colour paint finish with 1000Watts 240V sealed narrow beam lamp, barndoor arrangements including lamp, holder, C-clamp for hanging light fittings in all complete. Make :Canara Lights/ Modern Stage Services/ DTS/ Sholite.
Supply, fitting and fixing of 1000 watt halogen acting area light with 4 left barndoor including including 1000 watts halogen lamp, holder, reflector & C-clamp for hanging light fittings in all complete. Make : Canara Lights/ Modern Stage Services/ DTS/ Sholite.
Supply, fitting and fixing of LED PAR: 54 x 3W (12R +18G + 12B + 12W), 15º/30º/45º/60º LED PAR of IP65 rating, having life of 30,000 Hrs & deliver 4200 Lumens. The fixture should have capability to work on standby mode, via DMX 512 or integrated sound – 2 light program including fixing accessories such as jack and installation clamp/ bracket. Make : Sholite/Modern Stage Services/Canara Light/ DTS
Supply, fitting and fixing of 750 / 575W Profile Spot Light fittings made of CRC sheet metal including including 220v HPL 750W / 575W G9.5 Base lamp, holder, Color Temperature: 3200k, Optional Degree: 19°/26°/36°/50°, reflector & C-clamp for hanging light fittings in all complete. Make : Canara Lights / Modern Stage Services / DTS / Sholite.
Supply, fitting and fixing of cool light fittings consisting of 4 x 65 watts PL including dimmable blast, reflector, holder & C-clamp for hanging light fittings in all complete. Make : Sholite / Modern Stage Services / Canara Light / DTS
Supply, fitting and fixing of 1000 W Fresnel halogen spot fittings made of CRC sheet metal with 150mm dia fresnel lens and spherical aluminium anodized finish reflector, including 1000 watts Bi-pin halogen CP-70 lamp, holder, C-clamp for hanging light fittings in all complete. Make :Canara Lights/ Modern Stage Services/ DTS/ Sholite.
Supply, fitting and fixing of 500W Cyclorama halogenflood light fittings made of CRC sheet metal with matt black colour paint finish including 500 W halogen tube lamp, holder, reflector and C-clamp for hanging light fittings in all complete. Make: Canara Lights/ Modern Stage Services/ DTS/ Sholite.
Supply, fitting and fixing of Moving Head of 230W Beam with Input Voltage: AC110/220V, 50/60Hz, Lamp:7R 230W, Power: 350W, Life Time: 2200 hours, Color Temperature: 8000K, DMX Channel: 16CH, Pan: 540° (16bit), Tilt: 270° (16bit), Color Wheel: 14 colors + open, Gobo Wheel: 17 gobos + open, Effect Wheel: 8 facet rotating prism + frose + shake, Strobe: 0.5-9f/s, roandom or pulse flash, speed adjustable, strobe macro function, Dimmer: 0%-100% mechanical, Beam angle: 0% - 4% mechanical. Make : Canara Lights/ Modern Stage Services/ DTS/ Sholite/ PR Lights.
Supply, Installation of stage light operating console of 24/48 channel with a features of playback, patching 512DMX channels, VGA monitor port, LCD display, 24/48 channels control, 48 submasters etc. similar to model Jester. Make: Zero -88/ MA Lighting/ SGM
Supply of 24 KW 6 channel Electronic dimmer pack 19" rack mounted, each channel of 4 KW with DMX input via 5 pin XLR IN with MCB protection. Make :Modern Stage Services/ Canara Lights/ Sholite.
DMX Controller for 40 units with a maximum of 36 channels each. Internal libraries, 40 chases - Programs - Presets - Psychos. It can be mounted in a standard 19" rack (5 units), but can also be used as a desk-top unit, thanks to the shape of its frame. DMX in/out connector, SMPTE socket for changing memories in sync, independent regulation of scene and preset cross fade times. Audio input and built-in microphone for music sync functions. MIDI in/thru/out connector. Data and memories can be downloaded to a PC. Jack socket for pedal for stepping up/down through memories. Universal AL4 switching power supply included. Make: Zero -88/ MA Lighting/ SGM
Supply, installation of splitter with a facility of one input and 8 out put with a features to adding with other splitter compatible with DMX signal. Make :Canara Lights/ Modern Stage Services/ DTS/ Sholite.
Supply, installation of 72 way patch panel made MS with powder coated paint finish, desk type/ wall mounting 15A jack/top system with M.C.B. protection etc. for the each way of the total stage light system. (custom built).
Supply installation of Stage light dip box consisting of 2 nos, 15 A Socket with hinge cover.
Supply installation of stage light socket box of GI with top cover consisting of 15 Amp power socket and plug top.
Supply and laying of 14/0.2mm 2 C screened DMX signal cable cu flexible wire through PVC pipe/ cable tray.
Wiring by supply and laying of 3 core PVC sheted 2.5 sq.m. cu flexible wire through PVC pipe/ cable tray from light point to patch panel (Wire - Polycab / Finolex / Hevells. PVC Pipe - Pestoplust / Oriplust with ISI-M).
Supplying,fitting & fixing of Light Bar with motorized mechanism consisting of 1.5 HP 3 phase motor with gear box limit switches and push bottom control etc.including vertical moving arrangement 1 way,2 way,3 way,4 way,5 way pulleys properly fixed from grid structures with help of 6 mm dia. Steel wire rope complete in all respect for light bar with dual GI pipe of medium gauge with dia of 50 mm and 35 mm with cable tray complete in all respect as per direction of Engineer - in -change.
MS suspended grid structure providing and fixing 'C' channels of 100 x 50 x 6mm . 6 Nos placed from stage front to stage back wall and walk way by 50 x 50 x 6 angle and 600mm width including structural frame for hanging all stage craft mechanism.Size of stage srea approx 130 Sqm.
Supply & fixing of MS constructed Ladder for hanging the light between the wings and follow light with provision for housing of 2/3 Nos. light fittings with height and angular movement. complete in all respect as per direction of Engineer - in -charge.
Supply & fixing of MS constructed Ladder for FOH with provision for housing of 3 Nos. light fittings with angular movement. complete in all respect as per direction of Engineer - in -charge.
Supply installation and commissioning of VTPN DB consisting of incomer 160 A MCCB and outgoing 40A TP MCB 4 Nos.
Spare lamp for maintenance: Lamp for Plano Convex
Lamp for PAR
Lamp for Fresnel
Lamp for profile
Lamp for Cyclorama halogen
Lamp for cool light
Lamp for acting area halogen
Filter paper for various lightning effect.
Supply and placement of table and Chair made of 19 mm and 12 mm ply with 1.5mm laminated finish as per approved design of EIC. [ One set comprised of 2 nos. table of size 900 mm x 1200 mm and 4 nos. chair of size 450 mm x 450 mm all made of sal wood frame work and top made with 19 mm and 12 mm thick ply respectively with 1.5 mm laminated finish including polishing complete in all respect as per instruction of Engineer-in-Charge.]
Testing & commissioning of the complete system as per satisfiction of EIC.
Main Speaker System Supply & delivery of Left Line Array with following specification :- Powered Line Array speaker with LF transducer 12 inch or higher, HF transducer 1.75” or higher, Maximum peak SPL 131 dB or higher, rated continuous power (RMS) of on-board amplifier 800W or higher. Rigging system to be inluded. Approved Make: QSC / Clair Brothers / Meyer / d&b.
Supply & delivery of Right Line Array with following specification :- Powered Line Array speaker with LF transducer 12 inch or higher, HF transducer 1.75” or higher, Maximum peak SPL 131 dB or higher, rated continuous power (RMS) of on-board amplifier 800W or higher. Rigging system to be inluded Approved Make: QSC / Clair Brothers / Meyer / d&b
Supply & delivery of Subwoofer with following specification :- Powered sub-woofer speaker with LF transducer 18 inch or higher, Maximum peak SPL 135 dB, rated continuous power (RMS) of on-board amplifier 1000W or higher and compatible to JBL also. Approved Make: QSC / Clair Brothers / Meyer / d&b
Supply & delivery of DSP with following specification :-16 analog microphone / line inputs, 8 analog line outputs, 16 channels of AEC, 16 X 16 GPIO, Single POTS telephone interface and 4 VoIP soft phone instances. 128 X 128 Network i / o Channels, Dual LAN Ports Approved Make: QSC / ClearOne / BiAmp
Stage Front Fill Speaker System Supply & delivery of Front Fill Speaker with following specification :- 800W or higher active, portable loudspeaker system; 8-inch woofer; 1.75-inch compression driver; 105 degree conical waveguide; Tilt-Direct™ dual angle pole socket, DSP, for use as main or stage monitor speaker Approved Make: QSC / Clair Brothers / Meyer / d&b
Delay Fill Speaker System Supply & delivery of Delay Fill Speaker with following specification :- 800W or higher active, portable loudspeaker system; 10-inch woofer; 1.75-inch compression driver; 90 degree conical waveguide; Tilt-Direct™ dual angle pole socket, DSP, for use as main or stage monitor speaker Approved Make: QSC / Clair Brothers / Meyer / d&b
On Stage Monitors Supply & delivery of Stage Monitors with following specification :- Powered stage monitor speaker with LF transducer 12 inch or higher, HF transducer 1.75” or higher, Maximum peak SPL 131 dB or higher, rated continuous power of on-board amplifier 800W or higher Approved Make: QSC / Clair Brothers / Meyer / d&b
Control Room Monitoring Supply & delivery of Control Room Speakers with following specification :- 2-way, 6.5 Inch Surface Mount, Weather Resistant, Foreground/Background Loudspeaker with with 70V/100V transformer with 8 Ω Bypass includes Mounting Hardware Approved Make: QSC / Clair Brothers / Meyer / d&b
Supply & delivery of Amplifier for Control Room Speakers with following specification :- 1/2 RU, 2 channels Enegry Star Amnplifier/ Stereo Operation 200 Watss at 8 Ohms and 8 Ohm. Bridge Ooperation 400 Watts at 8 Ohms and 4 Ohms and 350 Watts At 70/100 Volts / 100 - 240 VAC Operation Approved Make: QSC / Lab Gruppen / Powersoft
Speaker Mounting Hardware Supply & delivery of Array Frame :- Array Frame for Line Array Speakers Approved Make: QSC / Clair Brothers / Meyer / d&b / JBL
Supply & delivery of Yoke for Front Fill :- Yoke Mount for Front Fill Speakers Approved Make: Customised as per requirement
Supply & delivery of Yoke for Delay Fill :- Yoke Mount for Delay Fill Speakers Approved Make: Customised as per requirement
Mixing Console & Sources Supply & delivery of Digital Mixing Console with the follwoing Specification :- Digital Audio Mixer with 24 mic/line inputs, 6 line inputs, 2 Stereo USB, 14 auxillary outputs, 32 x 32 tracks direct to hard disk or DAW recording or higher Approved Make: QSC / Midas / Allen & Heath
Supply & delivery of CD/DVD Player :- CD / DVD Player Approved Make: Sony / Samsung / LG
Microphone System Supply & delivery of Wireless Handheld Microphone with following specification :- Reciever - Receiver principle - double superheterodyne, Diversity principle - antenna switching diversity via internal antennas, Sensitivity (at peak deviation) - < 3 μV at 52 dB(A)rms S/N, AF frequency response - 50 to 16,000 Hz (–3 dB), Max. AF output voltage (at peak deviation, 1 kHz AF) - 1/4" (6.3 mm) jack socket (unbalanced): +6 dBu XLR socket (balanced): +12 dBu, Audio adjustment range - 45 dB, adjustable in 5-dB steps Transmitter - RF output power - 10 mW, AF frequency response - 80 to 16,000 Hz, Microphone type - dynamic, Pick-up pattern - cardioid, Adjustment range of transmitter sensitivity - 0 to –30 dB, adjustable in 10-dB steps Approved Make: Sennheiser / Audiotechnica / Beyerdynamic
Supply & delivery of Wireless Lapel Microphone with following specification :- Reciever - Receiver principle - double superheterodyne, Diversity principle - antenna switching diversity via internal antennas, Sensitivity (at peak deviation) - < 3 μV at 52 dB(A)rms S/N, AF frequency response - 50 to 16,000 Hz (–3 dB), Max. AF output voltage (at peak deviation, 1 kHz AF) - 1/4" (6.3 mm) jack socket (unbalanced): +6 dBu XLR socket (balanced): +12 dBu, Audio adjustment range - 45 dB, adjustable in 5-dB steps Transmitter - RF output power - 10 mW, AF frequency response - 50 to 16,000 Hz (Line) 80 to 16,000 Hz (Mic), Adjustment range of transmitter sensitivity - 0 to –30 dB, adjustable in 10-dB steps Microphones - Transducer principle - condenser, pre-polarized, Sensitivity - 20 mV/Pa, Pick-up pattern - omni-directional, Max. SPL - 130 dB Approved Make: Sennheiser / Audiotechnica / Beyerdynamic
Supply & delivery of Wireless Headworn Microphone with following specification :- Reciever - Receiver principle - double superheterodyne, Diversity principle - antenna switching diversity via internal antennas, Sensitivity (at peak deviation) - < 3 μV at 52 dB(A)rms S/N, AF frequency response - 50 to 16,000 Hz (–3 dB), Max. AF output voltage (at peak deviation, 1 kHz AF) - 1/4" (6.3 mm) jack socket (unbalanced): +6 dBu XLR socket (balanced): +12 dBu, Audio adjustment range - 45 dB, adjustable in 5-dB steps Transmitter - RF output power - 10 mW, AF frequency response - 50 to 16,000 Hz (Line) 80 to 16,000 Hz (Mic), Adjustment range of transmitter sensitivity - 0 to –30 dB, adjustable in 10-dB steps Microphones - Transducer principle - condenser, pre-polarized, Sensitivity - 1.6 mV/Pa, Pick-up pattern - cardioid, Max. SPL - 150 dB Approved Make: Sennheiser / Audiotechnica / Beyerdynamic
Supply & delivery of Vocal Corded Handheld Microphone with following specification :- Transducer principle (Microphone): dynamic, Pick-up pattern: super-cardioid, Frequency response (microphone): 40 –16,000 Hz, Sensitivity (free field, no load at 1 kHz): 1.8 mV/Pa Min. terminating impedance: 1000, Connector: XLR-3, Approved Make: Sennheiser / Audiotechnica / Beyerdynamic
Supply & delivery of Instrument Corded Microphone with following specification :- Transducer principle: pre-polarized condenser microphone, Pick-up pattern: cardioid Frequency response: 20.....20,000 Hz, Sensitivity (free field, no load at 1 kHz): 7 mV/Pa Nominal impedance: 100 Ω, Min. terminating impedance: 1000 Ω, Equivalent noise level: 19 dB(A), Preattenuation: 0, −10, −20 dB, Bass filter: linear, roll-off 130 Hz, 6 dB/oct., cut-off 85 Hz, 18 dB/oct., Max. sound pressure level (active): 137, 147, 157 dB, Phantom powering: 48 V/2.2 mA, Connector: XLR-3 Approved Make: Sennheiser / Audiotechnica / Beyerdynamic
Supply & delivery of Gooseneck Microphone with following specification :- Transducer principle - pre-polarised condenser microphone, Acoustics - cardioid, Frequency response - 50 Hz - 20 kHz, Nominal impedance - < 100 Ω, Maximum sound pressure level - 130 dB SPL, Equivalent noise level - 26 dB (A), Phantom powering - P12 - P48 V, Current consumption microphone - 3 mA, Connectivity - XLR 3M Approved Make: Sennheiser / Audiotechnica / Beyerdynamic
Supply & delivery of Gooseneck Microphone Stand:- Gooseneck Microphone Desk Stand Make: Sennheiser / Audiotechnica / Beyerdynamic
Cabling & Installation 15U Equipment Rack Make: Comrack / Valrack / President
Interconnects, connectors (1 Lot) Make: Neutrik / Amphenol / Swisscraft
Chain Pulley Arrangement for hanging Line Arrays
Stage box 16/4 Make: Hawk / Sommer / Link
Snake 20 Core with necessary connectors (33 Mtrs Length) Make: Hawk / Sommer / Eurocable
Speaker cable - Twinaxial 2 x 2.5 sq. mm, each roll is 100m for surround speakers Make: Krystal / Sommer / Eurocable
Microphone cable 100Meters for inputs, KLA12-BK & KLA181 Make: Krystal / Sommer / Eurocable
Microphone Stand - Big Make: Hawk / Ultimate / Ahuja / JBL
Microphone Stand - Small Make: Hawk / Ultimate / Ahuja / JBL
Installation & Programming Charges as per satisfiction of EIC.
PART (E-17) : SITC OF SOLAR POWER SITC of roof top type grid Connected Solar Photovoltaic power plant including five (5) years Warranty and five (5) years Comprehensive Maintenance on turnkey Basis, as per detailed Specification furnished .(PV Cell should be manufactured in India. Undertaking should be uploaded in technical bid and Certificate must be submitted during supply of PV Modules) (Without Battery). Allocation of Space -Main building roof top [Make for SPV Module :- Vikram Solar/ Waaree/ TATA Solar/ Sova Power/ Emmvee Photovoltics ]
PART (E-18) : SITC OF BUILDING MANAGEMENT SYSTEM SITC Building Management System (BMS) as per following requirement. It consists of BMS Workstation with minimum PC configuration Intel Core i7,1TB HDD, 4 GB RAM, 12X DVD drive, 17 " LCD colour monitor and Colour laser printer of A4 size. Network Management Tool - shall be compatible with Microsoft Windows 10Professional and a complete set of integrated LONWORKS network/ BACnet management tools for working with LONWORKS/ BACnet networks. Graphical Programming Software - A set of tools for the development of the DDC control logic, point management, global properties such as alarm, trend and scheduling.
The IBMS framework shall utilize JAVA based automation products and services with built-in Internet connectivity to a broad range of distribution partners in the building automation, energy services, power/utility, and industrial sectors. The Framework shall bring together the computerization of control applications under the umbrella of single integrated system architecture. System Interface Controller hardware features with Ethernet Port -10 / 100 Mbps, RS-485 port, LONWORKS Interface Port – 78KB TP/FT-10 Flash memory for long term data backup Calendar functions,Scheduling, Trending,Alarm monitoring and routing,Time synchronization, Integration of LONWORKS controller data,Integration of BACnet MS/TP and BACnet IP controller. BMS should have to be provided for controlling and monitoring the following networks: Chiller,AHU , Fire Pumps,Fire Panel, Water Pumps, STP, Monitoring of H.T panel, Main L.T Panel and D.G Set, Lift,CCTV etc.
N.B. :- a.THE NUMBER BESIDE OR BELOW THE EACH ITEM SPECIFY THE RESPECTIVE ITEM NO & PAGE NO OF PWD SCHEDULE OF RATES FOR ELECTRICAL WORK (APRIL,2014). SO, [ 2/C-1 ] NEANS ITEM NO 2 OF PAGE NO C-1. b. Details specification is given seperately for some items. Rate should be quoted accordingly. c. Make list is given seperately - materials must be be procured as per make list or make given with items. d. Rate should be quoted inclusive of all the Taxes & Duties.
SECTION (O) : I.T. WORKS Supply & Laying of Hot Dip Galvanized Steel MS-1079 (O) perforated cable Tray as per IS 4759,629,2633 (300 mmx 25 mm x 1.6 mm) with all OEM Equal T/Horizontal Bend/Crossovers/reduces/Coupler plates and ceiling suspension/wall support system as may be required at site. Make: Elcon/Mk/Legrand/SIEMENS/L&T/Havells
Supply & Laying of Hot Dip Galvanized Steel MS-1079 (O) perforated Cable Tray As per IS 4759,2629,2633.[200mmx25mmx1.6mm] with all OEM T/Horizontal Bend/Crossovers/Reducers/Coupler Plates and ceiling suspension/wall support system as may be required. Make: Elcon/Mk/Legrand/SIEMENS/L&T/Havells
Supply & laying of 75 mmX 25 mm 18 SWG Alluminium raceway with required GI junction boxes including stainless steel top cover with suitable cable-exit secured with rubber gasket and all accessories with floor/wall cutting and restore with sundey materials.(250 mtr for court building, 500 mtr for auditorium) Make:Elcon/MK/Legrand/SIEMENS/L&T/Precision /Presto Plast/Supreme/Oriplast.
Cutting channel of 31 mmx31mm 18 SWG size on masonry wall incl.S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire incl.mending good damages to building works, 19 mm dia 3 mm thick polythene pipe without continuity wire.
Supply & Laying of 19 mm Dia HDPE Pipe (ISI marked) with all accessories as required for the entire system with all OEM accessories as per the site requirement. Make: Supreme/Oriplast Quality: ISI
Supply & fixing of 8''X8''X2.2'' Stainless Steel Box with Steel Top Cover. Make: MK/Legrand/SIEMENS/L&T/Havells
Supply & Fixing of 6''X6''X2.2'' Stainless Steel Box with Steel Top Cover. Make: Mk/Legrand/SIEMENS/L7T/Havells
Two module GI back for I/O port and Telephone outlet (GI box only)
AC Room, Pump Room, Generator Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. Pakur Variety
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
1st floor
2nd floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4 m Tor steel/Mild Steel
1st floor
2nd floor
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i) Shuttering without staging in foundation.
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. In ground floor
1st floor
2nd floor
Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth
In superstructure, ground floor
In superstructure, First floor
In superstructure, Second floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
First Floor
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).
Pre-Constructional Anti-termite measures: (a) Anti termite treatment to bottom surface ( in case of masonry foundation and basements) and the sides (upto a height of 300 mm. from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 6.2.1. of code IS- 6313 (part -II) 1981. (Mode of measurment will be the plan area of foundation treated.)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (a) 20 mm thick plaster
(ii) With 1:4 cement mortar (b) 15 mm thick plaster
(ii) With 1:4 cement mortar (c) 10 mm thick plaster
(ii) With 1:4 cement mortar (b) 20 mm thick plaster First floor
(ii) With 1:4 cement mortar (b) 15 mm thick plaster First Floor
(ii) With 1:4 cement mortar (c) 10 mm thick plaster First Floor
(ii) With 1:4 cement mortar (b) 20 mm thick plaster Second floor
(ii) With 1:4 cement mortar (b) 15 mm thick plaster Second Floor
(ii) With 1:4 cement mortar (c) 10 mm thick plaster Second Floor
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (ii) Other than Coloured decorative including white
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] (a) With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana (ii) Area of each Slab/tile exceeding 0.3 sq.m. but not exceeding 0.6 sq.m.
M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. In ground floor.
Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete.
PVC Door Shutter-30 mm thick: Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59 mm x30 mm section with 2.0 mm (+/-0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to each other by self tapping screws and 1 solid polymeric or M.S. galvanised tubular 'L' shaped bracket 100mm x 200mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 120 mm x30mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle, reinforced by solid polymer bar of 200 mm long at both ends and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mmx25 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials,labour, and hire of tools and plants and appliancesi/c carriage of all materials taxes and all other incidental charges complete.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
(b) Supplying fitting and fixing steel rolling grills link type, shutter with 18 B.G .of approved type steel to the section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm)
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) ii) Luxury Quality
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) One Coat
First Floor
Second Floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion
First Floor
Second Floor
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn,Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.
B) UPVC Fittings: c) Bend 87.5 degree (ii) 110 mm. Dia.
d) Shoe (ii) 110 mm. Dia.
Supplying, fitting and fixing shower of approved brand and make. (f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (vii) 25 mm dia
Supplying, fitting and fixing bib cock or stop cock. (a) (ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
(b)(ii) Chromium plated Concealed Stop Cock (Equivalent to Code No.514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(f) (i) Polythene Bib Cock / Stop Cock (HD) with metal inlet (EMCO / ATLAS or equivalent) 15 mm
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. mplete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 25 mm
(a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 40 mm
(b) For Concealed Work (i) CPVC Pipes Class-1,SDR-11 15 mm
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity
Labour for hoisting plastic water storage tank. (ii) Above 1500 litre upto 5000 litre capacity.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iii) 600 mm long
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps. (iii) 900 mm long
Supplying, fitting & fixing Cast iron soil pipe only conforming to I.S. 3989/ 2009 and I.S. 1729/2002 with bobbins, nails etc. including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (Measurement will be made along the center line of the total pipe line in fitted condition including specials,payment for specials & Painting will however be paid seperately). (a) With valamoid joints including sealing with sand cement morter (4:1) upto quarter depth. (ii) 100 mm dia. (internal)
Supplying, fitting & fixing H.C.I. bend with door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (a) With valamoid joints including sealing the top with cement mortar (4:1) (ii) 100 mm dia.
Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (i) 100 mm dia.
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (b) With 'S' trap
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pipe
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting and fixing bathroom shelf of approved make of size 580 mm X 150 mm (porcelain).
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (ii) 25 mm dia. and 600 mm long
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (a) 75 mm
(A) (i) Single Socketed 3 Meter Length (b) 110 mm
(B) Fittings (iii) Door Tee (a) 75 mm
(B) Fittings (iii) Door Tee (b) 110 mm
xi) Door Bend (T.S.) (a) 75 mm
xi) Door Bend (T.S.) (b) 110 mm
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground (i) 75 mm dia.
(B) Under ground (ii) 110 mm dia.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. ii) With Bazree (N.B Variety) (SAIL/TATA/RINL)
Elevated water reservoir & under ground reservoir Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work
Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge). 6 Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge). (a) Depth upto 1.5 m
(b) For additional depth beyond 1.5 m. and upto 3.00 m
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Foundation & upto 4.00 meter From Ground Level
b) Beyond 4.00 meter & upto 8.00 meter from G.L
c) Beyond 8.00 meter & upto 12.0 meter from G.L
d) Beyond 12.00 meter & upto 16.0 meter from G.L
e) Beyond 16.00 meter & upto 20.0 meter from G.L
f) Beyond 20.00 meter & upto 24.0 meter from G.L
g) Beyond 24.00 meter & upto 28.0 meter from G.L
Batch Mixed concrete of M 30 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant nder controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a latform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 320 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
Beyond 28.00 meter from G.L
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (i) Tor Steel / Mild Steel. I. SAIL / TATA / RINL (a) For works in foundation, basement and upto roof of ground floor/upto 4 m
b) Beyond 4.00 meter & upto 8.00 meter from G.L
c) Beyond 8.00 meter & upto 12.0 meter from G.L
d) Beyond 12.00 meter & upto 16.0 meter from G.L
e) Beyond 16.00 meter & upto 20.0 meter from G.L
f) Beyond 20.0 meter & upto 24.0 meter from G.L
g) Beyond 24.00 meter & upto 28.0 meter from G.L
h) Beyond 28.00 meter from G.L
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i) Shuttering without staging in foundation.
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m
b) Beyond 4.00 meter & upto 8.00 meter from G.L
c) Beyond 8.00 meter & upto 12.0 meter from G.L
d) Beyond 12.00 meter & upto 16.0 meter from G.L
e) Beyond 16.00 meter & upto 20.0 meter from G.L
f) Beyond 20.0 meter & upto 24.0 meter from G.L
g) Beyond 24.00 meter & upto 28.0 meter from G.L
(a) Hire and labour charges for shuttering for concrete work in overhead R.C. Reservoir on separate R.C. frame including fitting,fixing andstriking offafter compeltionofworkincluding staging upto 4 m using ply board or steel shuttering.
(b) Extra for Staging beyond 4 m [mode of measurement: Area of unsupported horizontal projection (where staging beyond 4 m is practically unavoidable) x mean height of staging] above initial 4 m.
(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/ staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (c) 10 mm thick plaster b)1:4 cement sand mortar
b) Beyond 4.00 meter & upto 8.00 meter from G.L
c) Beyond 8.00 meter & upto 12.0 meter from G.L
d) Beyond 12.00 meter & upto 16.0 meter from G.L
e) Beyond 16.00 meter & upto 20.0 meter from G.L
f) Beyond 20.0 meter & upto 24.0 meter from G.L
g) Beyond 24.00 meter & upto 28.0 meter from G.L
h) Beyond 28.00 meter from G.L
Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) One Coat
b) Beyond 4.00 meter & upto 8.00 meter from G.L
c) Beyond 8.00 meter & upto 12.0 meter from G.L
d) Beyond 12.00 meter & upto 16.0 meter from G.L
e) Beyond 16.00 meter & upto 20.0 meter from G.L
f) Beyond 20.0 meter & upto 24.0 meter from G.L
g) Beyond 24.00 meter & upto 28.0 meter from G.L
h) Beyond 28.00 meter from G.L
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) a) Normal Acrylic Emulsion
b) Beyond 4.00 meter & upto 8.00 meter from G.L
c) Beyond 8.00 meter & upto 12.0 meter from G.L
d) Beyond 12.00 meter & upto 16.0 meter from G.L
e) Beyond 16.00 meter & upto 20.0 meter from G.L
f) Beyond 20.0 meter & upto 24.0 meter from G.L
g) Beyond 24.00 meter & upto 28.0 meter from G.L
h) Beyond 28.00 meter from G.L
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr a) upto 4.00 meter From Ground Level
b) Beyond 4.00 meter & upto 8.00 meter from G.L
c) Beyond 8.00 meter & upto 12.0 meter from G.L
d) Beyond 12.00 meter & upto 16.0 meter from G.L
e) Beyond 16.00 meter & upto 20.0 meter from G.L
f) Beyond 20.0 meter & upto 24.0 meter from G.L
g) Beyond 24.00 meter & upto 28.0 meter from G.L
h) Beyond 28.00 meter from G.L
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m a)Beyond 28.00 meter from G.L
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Supplying, fitting and fixing in position FRP/GRP/COMPOSITE UV stabilizer Manhole Cover with high abrasion surface of 7mm top thickness with density of 2KG/m³ - approved make with rim of approved make (Heavy type) (iv) 5 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of size Frame: 600 mm (24")
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately (ii) 80 mm dia. medium
Cleaning and disinfecting above 2000 litre Water Tank including masonry reservoir.
Supply installation of lighting solid conductor rod of phosphorous bronze size ( 2 mtrs. X 12 mm dia. )on top dome of the R.C.C.overhead reservoir,laying lightning conductor of 8 mm. dia. galvanised iron wire runs from the roof upto G.L. along the shell wall and column fitted with necessary rust proof clamps,laying 10mm. dia. galvanised conductor wire from G.L. to bottom of the earthing main pipe fitted and fixed through 12 mm. dia. best quality P.V.C. pipe and connecting with the main earthing G.I. pipe of 50 mm. dia. class (c) heavy type of 3.50 M. length to be used as earthing electrode driven down to at least 3.50 m. below G.L. and filling up with charcoal, making necessary arrangements for testing the same as per I.E.E. rule.
Preparing an in-built sign board on outer surface of tank shell wall by render a board of size 1.7 m X 1.0 m after plastering the tank surface with (2:1) cement morter 20 mm thick bold by (2:1) cement morter with ornamental english lettering with letters and figures up to 200 mm long 12 mm width and 20 mm raised, painting the board and lettering with two coats of ready mixed paint over a coat of priming of different shades and types as appropriate including making necessary staging scaffolding all complete as per direction of the E.I.C
Supply at site/local store C.I.D.F. pipe and specials as per relevant I.S. specification with latest amendments including cost of loading, carrying, unloading, stacking properly and sales tax & all other charges etc. complete as per direction of E.I.C. (Mode of measurement will be on book weight).
Supply at site/local store C.I.D.F.Sluice Valve ( P.N-1.6) conforming to I.S. 780/1984 & IS 14846/2000 with latest amendments including cost of loading, carrying, unloading, stacking properly and sales tax & all other charges etc. complete as per direction of E.I.C. ( Ref:-W/Order No. 1355/SWSD Dt. 02.11.17 of EE/SWSD) (a) 250 mm dia.
(b) 150 mm dia.
(c) 100 mm dia.
Making flange joints in the pipe line (C.I./D.I.) with the supply of nuts & bolts with washer (nuts & bolts, washer should be TATA/GKW make) rubber insertion 6 kg../m.sq. ⅛ gauge and other materials required (all standered type and I.S.I. approved quality) etc. all complee including making joints holes, shuttering, planking dewatering the trenches and supply of all materials and labour charges all complete as per diretion of E.I.C. i ) 80 mm. dia.
(ii)100 mm dia.
(iii)150 mm dia
(iv) 250 mm dia.
Construction of sluice valve chember as per departmental drawing no.32/NBC/DC/PHE/79/97 with brickwork in cement morter (4:1)on 15 cm of C.C.(6:3:1)with supply of approved quality C.I.surface box embedded into 150mm thick R.C.C.removal slab in (4:2:1) incl.fitting fixing overhauling the valve if necessary.all complete as per specification and instruction of E.I.C. (Valves,Speacials will be supplied departmentally). i )80 mm. dia. To 150 mm. Dia.
ii) 250 mm dia.
Erecting, hoisting, and fitting, fixing, laying and building in position C.I. flanged or socketted pipes with necessary specials, like valves, bell-mouth with paddle collers etc. for delivery, overflow, inlet and washout pipeline etc. as shown in drawing as per direction including supplying fitting, fixing proper with m.s. clamps supports stages for all top as of pipes with painting of specials, pipes complete with two coats of black Japan over a coat of red oxide primer. (a) 250 mm dia
b)150 mm dia
c)100 mm dia
Supplying mosquito proof stainless steel netting of 24 X 24 Mesh fitted in 25 X 25 X 6 mm M.S. angle frame of approved quality as per drawing for ventilator including fitting,fixing in R.C.C. wall with necessary fixtures,painting two coats of Black Japan paint all complete.( Analysed Rate, Analysis Enclosed )
Making arrangement for water tightness test of R.C.C. over head reservoir conforming to the provisions laid down in I.S. 3370 (part-I ) 965, by filling with water upto Top Water Level ( T.W.L. ) as shown in the drawing and as per direction of E.I.C. including the arrangement of water, it's carriage & lifting by necessary pipes, fittings and pumping machinery etc. all required for the purpose.
Hydraulically testing of different type (D.I./C.I./A.C.) of pipe in section by hand pump or pump and the proposed field testing to check the quality of workmanship of pipeline and the quality of pipe.The test pressure shall be kept 1.5 times to the actual operating pressure (i,e the test pressure recomended by I.S.I. for corresponding pipe materials whether the gauge pressure will remain static for 30 minutes by filling water including supply of necessary equipment such as generator set/ pump,gauge, air compressor in-section along with as specified in the specification including providing blank flange duly stiffened with angle or joint section on either side of the pipe line and necessary equipment, and supply of water will be necessary for testing work including disposal of water after testing etc. all complete as per direction of E.I.C. ( When department will supply water for test, the rate will be reduced @ 33% from the following rate ) i ) 100 mm. dia.
ii ) 150 mm. dia.
iii ) 250 mm. dia.
Disinfection of distribution line (A.C./C.I./D.I.) by flashing with water containing bleaching powder @ 56 mg. per liter of water and cleaning the same with fresh water.The water should remain in the main for a minimum period of 24 hours. The bleaching powder solution will be applied continuously for a period of time, to provided column of chlorinated water in contact with all inner surface of the main for a period of at least 3 hours operation. ( To be repeated twice )( The D.C.M. brand bleaching powder and water will be supplied by the agency )@ .405 Kg bleaching powder/meter i ) 100 mm. dia.
b)150 mm dia
c)250 mm dia
Supplying and laying Polythene Sheet (150gm/sq.m.) over damp proof course or below flooring or roof terracing or in foundation trenches.
Rain water harvesting, pump, sewerage, pipe distribution Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface] With 1:4 cement mortar
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.
Hire and labour charges for Steel shuttering form, made out of 2mm thk (14 SWG) M.S Sheet welded with peripheral angle-Stiffner (40x40x5) frame work and placed over suitable Telescopic/ Adjustable Span (2.45-4.16m) weighing > 39 kg (SO+SI) & supported by approved adjustible telesscopic prop (2.50-4.25m) weighing > 18.5 kg for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i) Shuttering without staging in foundation.
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. A) Pakur variety
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (i) Tor Steel / Mild Steel. I. SAIL / TATA / RINL (a) For works in foundation, basement and upto roof of ground floor/upto 4 m
Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for onpressure underground Drainage, Sewerage & Cross drainage application. and including cutting of trench,filling foundation with excavated earth & providing minimum sand cushioning of 300 mm to 450 mm as per direction of E-i-C. (i) 150mm internal dia
(iv) 200 mm internal dia
ii)300 mm internal dia
(iv) 450 mm internal dia
(iv) 600 mm internal dia
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary einforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL)
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only). (i) 900 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 150 mm dia. of approved make A) With Pakur variety. (SAIL/TATA/RINL)
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides,bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL)
iii) Extra for each additional depth of 150 mm or part thereof beyond initial 600 mm depth.(upto 900mm)
Providing and fixing squre mouth SWR gully trap of the following size in brick masnory chamber of standard design with first class brick and trap to be set in cement concrete 1:2:4 both side 12 mm thick plastering with floating coat of neat cement .making necessary connections & providing water tight CI cover with frame of 300mm x300mm internal size .The weight of cover & frame note be less than 8 kg per standard design . including necessary excavation, dewatering , raming and removing the same complete as requird . 300mmx300mm chamber with 150mmx100mm size P trap
Providing and installing 150 dia glazed stone water sewer trap in position in inspection chamber or man hole
Supplying, fitting and fixing in position RP/GRP/COMPOSITE UV stabilizer Gully Pit Cover with high abrasion surface of 7mm top thicknes, density of 2KG/m³ of approved make with rim of approved make (Heavy type) (ii) 20 M.T. Gully pit cover (yard gully) with arrangement for opening of size Frame Clear Opening Nos. 5904.00 385 mm X 317 mm. Cover Out to Out 445 mm X 377 mm.
Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications. (iv) 150 mm dia.
Providing and installing 150 dia glazed stone water sewer trap in position in inspection chamber or man hole
Supplying, fitting and fixing cast iron spun pipe conforming to I.S.1536/1976 with all necessary specials including cutting trenches in any soil or through masonry, concrete etc., if necessary,and mending good all damages including jointing pipes with Tyton joints as per manufacturer's specifications and filling up the trenches all complete but excluding the cost of masonry or concrete work, if required. Class A:80 mm nominal dia
150 mm nominal dia
200 mm nominal dia
C.I. sluice valve with flanged ends drilled to as per I.S. 1358/62 and having all cast iron components as per I.S. 780/71 solid forged bronze inside screw spindle having ultimate tensile strength not less than 4.72 MT per sq. cm. Spindle nut valve and seat faces of hard wear resisting,manufactured from best quality gunmetal conforming to I.S. 780/71,painted black all over with asphalt base paint tested to 21 kg (hydraulic pressure) per sq. cm., valve opening to anticlockwise direction, fitted and fixed complete.
150 mm nominal dia
200 mm nominal dia
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials(a) For Exposed Work CPVC Pipes Class-1, SDR-11 40 mm dia
50 mm dia
STP WTP Final Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. With Available Excavated Earth
Batch Mixed concrete of M 20 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [With Batching Plant & Transit Mixer] [Pakur Variety]. With approved concrete pump. In Ground Floor& Foundation.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns,Walls (any thickness) including attached pilasters, butteresses, plinth and string courses,Suspended floors, roofs, landings, balconies and access platform,Lintels, beams, plinth beams, girders, bressumers and cantilevers,Columns, Pillars, Piers, Abutments, Posts and Struts, Weather shade, Chajjas, corbels etc., including edges
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Thermo-Mechanically Treated bars : SAIL/TATA/RINL
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. For built up sections / srtuctural members of specified sections
Providing and fixing M.S. grating, over straight or curved drain, including fixed frame of angle 60 mm x 60mm x 6 mm size fixed to concrete with 25 mm x 3 mm hold fasts approx. 100 mm long welded at interval of 600 mm and welded cross braced at 1200 mm interval by 50 mm x 6 mm thick MS flats. The removable grating shall be made of with outer frame of size 600 mm long with M.S. angle 50 mm x 50 mm x 6 mm having welded cross members on one direction with M.S. flats of size 44 x 6 mm at a spacing of 30 mm c/c. Including two of synthetic enamel paints over a coat of primer complete as required. For 600 mm wide drain (For External Drain)
Supplying, installing, testing and commissioning of Water Treatment Plant with of Capacity : 12.5 Cu.M / Hr. (12 hrs operation, for Circuit court building) WTP- Fliter Feed Pump @ UGT Capacity: 9 cu mt / Hr Head : 35 m Softner - 9 cu.m / hr Sand Filter - 9 cu.m / hr Chlorinator - 6 lt / hr. Activated Carbon Filter - 9 cu.m / hr
Supplying, installing, testing and commissioning of Water Treatment Plant with of Capacity : 24 Cu.M / Hr. (12 hrs operation for other buildings) WTP- Fliter Feed Pump @ UGT Capacity: 4 cu mt / Hr Head : 50 m Softner - 4 cu.m / hr Sand Filter - 4 cu.m / hr Chlorinator - 6 lt / hr. Activated Carbon Filter - 4 cu.m / hr
Providing and installing crystalline waterproofing treatment to inside surfaces of the water retaining structures VERTICAL SURFACES : a) Treatment shall consist of preparation of surfaces including ‘V’ grooves at junctions and joints, pressure grouting the same and curing for specified period. b) Applying two coats of approved crystalline waterproofing compound at specified intervals as recommended by manufacturer and as directed by Engineer-in charge and allowed to cure. c) Plastering of walls and finishing smooth with 15 mm thick cement mortar 1:4 (1 cement : 4 fine sand) admixed with approved waterproofing compound in recommended proportions. HORIZONTAL SURFACES : d) Laying of 30 mm average thick cement concrete of mix 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate of 12.5mm nominal size) admixed with approved waterproofing compound in recommended proportions, on floors to required gradient, including rounding of corners / junctions with walls and floors etc., and finished smooth and cured. Tank shall be tested by filling with water for required depth and maintaining it for 72 hrs. for checking the leakages. The rate includes giving 10 year guarantee for waterproofing on a Rs.100/- stamp paper in approved proforma.
Providing orange colour safety foot rest of minimum 16 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design
Flushing Water feed pumps Circuit Court Building ESR Each pump Water Flow Rate : 8 cum / hr Head : 50 M Purpose : Flushing water Make : DP, Grundfos, ITT, Kirloskar, Engg.
Providing & fixing PN 10 butterfly valve including rubber gasket, flanges, nuts, bolts, washers & painting complete as required. 40 mm dia
50 mm dia
65 mm dia
80 mm dia.
150 mm dia
Providing & fixing C.I. wafer type check valve tested to a pressure not less than 15 Kg/sqcm, including rubber gasket, flanges, union, nuts, bolts, washers & painting complete as required. 80 mm dia
Providing & Fixing Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and wahsers complete as required. 80 mm dia
Supply, installation & comissioning of package type FRP underground sewage treatment plant 80KLD (80m3/day) of reputed company Like Sintex/Arvind Envisol/Hi-Clear with the following specification. i) Cylindrical Type 100% FRP underground Primary Collection Tank(UL1316 Standard) ---Size: 7936 mm(L) x 2430 mm (Dia)--One No. ii) Sylindrical Type 100% FRP base Underground fixed film aeration tank (UL1316 Standard) ----Size: 9726 mm(L) x 2430 mm (Dia)---One no. iii)Air blowers Twin Lobe--2 Nos(1W+1SB) , iV) Control panel--One no, V) FRP Strap---4nos, Vi) Concrete Dead Man--2 Nos. Vii)Excavation 7 mtr X 12 mtrX4.5 Mtr---One no. Viii) PCC 7.0 Mtr X 12.0 Mtr --One no, iX) Tank Lowering and back filling with Crushed stone--One no,X) Manhole 1.0X1.0X1.5 Mtr-Brick work---6 Nos ,Xi) Blower Room-2X2 Mtr with one door and one window--One no. Xii) Internal Pipe connection --One set. coplete to function STP properly. Rate includes cost of Supply, installation, Transportation and all taxes including GST and labour complete in all respect.
Supply, installation & comissioning of package type FRP underground sewage treatment plant 50KLD (50m3/day) of reputed company Like Sintex/Arvind Envisol/Hi-Clear with the following specification. i) Cylindrical Type 100% FRP base Underground Primary Collection cum fixed film aeration tank (UL1316 Standard) ----Size: 12790 mm(L) x 2430 mm (Dia)---One no. ii)Air blowers Twin Lobe--2 Nos(1W+1SB) , iii) Control panel--One no, iv) FRP Strap---4nos, V) Concrete Dead Man--2 Nos. Vi) Excavation 3.5 mtr X 13.7 mtrX4.5 Mtr---One no. Viii) PCC 7.0 Mtr X 12.0 Mtr --One no, iX) Tank Lowering and back filling with Crushed stone--One no, X) Manhole 1.0X1.0X1.5 Mtr-Brick work---3 Nos ,Xi) Blower Room-2X2 Mtr with one door and one window--One no. Xii) Internal Pipe connection --One set. Rate includes cost of Supply, installation, Transportation and all taxes including GST and labour complete in all respect.
Tube well Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (b) For depth upto 250 metre for 200 mm dia. Tube well with top enlargement of 300 mm dia.(upto 50 metre). .
Next 50 metre
Next 50 metre
Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of of TATA make (heavy quality) as per standard specification, 5 mm thick. 200 mm dia pipe
300 mm dia pipe
Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge (a) 200 mm nominal dia (i) 6.00 mm wall thickness
Supplying, fitting and fixing in position G.I. pipes of TATA ake for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making hreads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately) 80 mm dia. medium quality
Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. 200 mm dia
Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. 300 mm
Supplying, fitting and fixing heavy type bell mouth reducing socket. 200 mm X 300 mm
Supplying, fitting and fixing G.I. cap at top 300 mm
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, esting etc. complete in all respect as per direction.
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed ravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
Providing 200 mm centre guide with clamp
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.
Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report.
Supplying, fitting and fixing Submersible Pump make KSB/CROMPTON/KIRLOSKER/BE pump or equvalent reputed manufacturers as approved by the Engineer-in-Charge.The rate includes the cost of the pump including transportation charges,lowering charges & all Taxes complete in all respect. Submersible Pump 10 HP
Supplying, fitting and fixing Mono Block Pump make KSB/CROMPTON/KIRLOSKER/BE pump or equvalent reputed manufacturers as approved by the Engineer-in-Charge.The rate includes the cost of the pump including transportation charges,lowering charges & all Taxes complete in all respect. Mono Block Pump 5HP
C.I. sluice valve with flanged ends drilled to as per I.S. 1358/62 and having all cast iron components as per I.S. 780/71 solid forged bronze inside screw spindle having ultimate tensile strength not less than 4.72 MT per sq. cm. Spindle nut valve and seat faces of hard wear resisting, manufactured from best quality gunmetal conforming to I.S. 780/71, painted black all over with asphalt base paint tested to 21 kg (hydraulic pressure) per sq. cm., valve opening to anticlockwise direction, fitted and fixed complete. 100 mm
Supply, erection,testing & commissioning of electric motor driven Jockey pump, horizontal, centrifugal type capable of delivering 180LPM at 105 MWC. The pump shall be coupled to TEFC motor of suitable KW with speed of 2900 RPM with all accessories mounted on common base frame. (MAKE-KIRLOSKAR, MATHER & PLATT)
Supply, erection, testing & commissioning of compartmentalised common control panel for above pumps. All components shall be housed in a common cubical made of 16 swg. M.S. sheet with required stiffners (if required). The panel shall be power quoted of approved colour both inside and out side. The panel shall have both bottom and top cable entry provisions and panel shall be mounted on pedestal of 300 mm height. The panel should have sufficient NO / NC contects for extending the status of fire pumps to the fire alarm panel. (Make-Star Enterprise, Fluid Energy System, Reputed)
Supply, laying, testing & commissioning of PVC outer sheath, steel armoured, aluminium /copper conductor, 1100 Volt Grade power cables with gland etc. The cable shall be laid in tray /hume pipe / in trenches / on walls / floors etc as required. Cables laid outdoors shall include the price of earth escavation providing brick and sand protection, refilling and compacting the earth. (Make- Polycab, Mescab) a 3.5C x 95 sq.mm YFY for main pump
b 4C x 10 sq.mm YFY for Jockey Pump
c 12C x 2.5 sq.mm for Diesel Engine
d 2C x 1.5 sq.mm for instrumentation
GI earthing strips of 50mm x 6mm thick, strips shall run on floor / ceiling / walls, from pump to control panel with necessary accessories as required. (Make -Reputed)
25 Sq.mm single core multistrand copper cable shall be run on floor / ceiling / walls, from thenearest earth bar to the pump control panel with necessary accessories as required. (MAKE-POLYCAB,MESCAB)
Supply and installation of pressure gauge, 1/2 inch bottom entry, of suitable range for pump set with ball valves and other accessories (Make- H GURU / FIEBIG / PRICOL)
Supply and installation of Pressure switches, SPDT type, of suitable range for pump sets with ball valves and other accessories (Make- INDFOS / SWITZER / DENFOS)
Supply,Erection, fabrication, testing of MS black steel pipe Heavy grade conforming to IS : 1239 Part 1 /3589 including all fittings viz. Elbows, tees, flanges, etc. reducer, clamps, MS support dash fasteners etc. including painting the pipe with two coats of approved red oxide primer and two coats of approved red enamel paint and welded joints complete with cutting and making good the walls, floors or any other surface (For pumping system ). (Make-TATA,JINDAL) a 250 mm NB x 6 mm thk
b 200 mm NB x 6 mm thk
c 150 mm NB
d 100 mm NB
e 80 mm NB
f 65 mm NB
g 25 mm NB
Supply,Installation, testing & commissioning of CI Gate Valve as pe IS:14846 (PN 16) with matching flanges complete with nuts & bolts. (Make-H.SARKAR / KARTAR/ KOLEY) a Size 200mm NB
b Size 150 mm NB
c Size 80 mm NB
d Size 65 mm NB
Providing & fixing Non return valve (Wafer type) with matching flanges complete with nuts & bolts. (Make-H.SARKAR / KARTAR/ KOLEY) a Size 150 mm NB
c Size 65 mm NB
Providing & fixing Butterfly valve as per BS :5155 (Wafer type) matching flanges complete with nuts & bolts(for Terrace pump). (Make-H.SARKAR / KARTAR/ KOLEY) a Size 150 mm NB
b Size 100 mm NB
Supply, Installation, testing & commissioning of CI Globe Valve as per IS:9338(PN16 rating) complete including matching flanges, nuts & bolts complete. (Make-H.SARKAR / KARTAR/ KOLEY) a Size 100 mm NB
Supply & installation of Gunmetal 4 way collecting head with 63 mm dia instantaneous type inlet 150 dia flanged outlet with built in check valve for fire brigade connection to fire water reservoir (IS : 904). (Make-NEWAGE / FIRESHIELD / SAFIEX)
Supply & installation of Gunmetal Fire Brigade Draw out connection with necessary foot valve for reservoir. (Make-NEWAGE / FIRESHIELD / SAFIEX)
B) FPS SYSTEM: Supply, erection, testing of MS black steel pipe Heavy Grade conforming to IS : 1239/3589 including all fittings viz. Elbows, tees, flanges, etc. reducer, clamps, included with joints complete with anticorrosive treatment to burried pipes by wrapping with 4mm thick PYPKOTE membrane applied over a coat of primer for external yard hydrant network. (Make-TATA,JINDAL) a 200 mm NB
b 150 mm NB
c 100 mm NB
d 80 mm NB
Supply, fabrication, erection & testing of MS black steel pipe Heavy grade conforming to IS : 1239/3589 including all fittings viz. Elbows, tees, flanges, etc. reducer, clamps, MS support dash fasteners etc. including painting the pipe with two coats of approved red oxide primer and two coats of approved red enamel paint and welded joints complete with cutting and making good the walls, floors or any other surface (Make-TATA,JINDAL) a 200 mm NB
b 150 mm NB
c 100 mm NB
d 80 mm NB
e 25 mm NB
Supply, installation, testing & commissioning of CI Gate Valve as per IS:14846 (PN 16) with matching flanges complete with nuts & bolts. (Make-H.SARKAR / KARTAR/ KOLEY) a Size 200 mm NB
b Size 150 mm NB
c Size 100 mm NB
d Size 80 mm NB
e Size 25 mm NB(SS construction)
Providing & fixing Non return valve (Wafer type) with matching flanges complete with nuts & bolts. (Make-H.SARKAR / KARTAR/ KOLEY) a Size 150 mm NB
b Size 80 mm NB
Providing & fixing Butterfly valve as per BS :5155 (Wafer type) matching flanges complete with nuts & bolts(for Terrace pump). (Make-H.SARKAR / KARTAR/ KOLEY) a Size 150 mm NB
b Size 100 mm NB
Supply,Installation of SS oblique type single headed Landing valve with 80 mm inlet and 63 mm outlet SS instantaneous male coupling with rubber cap and chain conforming to IS : 5290.. (Make-NEWAGE / FIRESHIELD / SAFIEX)
Supply,Installation of SS oblique type single headed Hydrant valve with 80 mm inlet and 63 mm outlet SS instantaneous male coupling with rubber cap and chain conforming to IS : 5290.. (Make-NEWAGE / FIRESHIELD / SAFIEX)
Supply & installation of SS branch pipe with 20 mm nozzle conforming to IS : 903 complete (Make-NEWAGE / FIRESHIELD / SAFIEX)
Supply & installation of 63 mm dia rubberized reinforced rubber line hose pipe in 15 m length conforming to IS : 636 Type I ISI marked with gunmetal male and female instantaneous coupling conforming to IS 903 wounded with 18 SWG copper wire complete (Make-NEWAGE / FIRESHIELD / SAFIEX)
Supply & installation of MS hose box of fabricated from 16 SWG CRCA sheet double door with lockable arrangements to accommodate 2 RRL hose of 15 m length and one branch pipe painted white inside and red outside with one key. (750x600x250 mm) (Make-NEWAGE / FIRESHIELD / SAFIEX)
Supply & installation of swinging type hose reel drum fabricated from 14 SWG CRCA sheets painted with red colour stove paint 2 coats over 1 coat of primer with 30 m long 20 mm dia rubber hose pipe with 10 kg/sq cm working pressure with SS self closing shut – off nozzle of 5 mm outlet fixed on wall with dash fasteners and necessary shut off valve. (Make-NEWAGE / FIRESHIELD / SAFIEX)
Supply & installation of SS 2 way inlet connection with 63 mm dia instantaneous type inlet 100 dia flanged outlet with built in check valve for fire brigade connection to fire riser (IS : 904) with one no. butterfly valve of 100NB size (Make-NEWAGE / FIRESHIELD / SAFIEX)
Supply & installation of Gunmetal 3 way collecting head with 63 mm dia instantaneous type inlet 150 dia flanged outlet with built in check valve for fire brigade connection to fire hydrant network (IS : 904) with one no. butterfly valve of 150NB size. (Make-NEWAGE / FIRESHIELD / SAFIEX)
Supply & installation of automatic 25 NB Air Release Valve (Make-H.SARKAR / KARTAR/ KOLEY)
Supply & installation of Globe Valves in S.S Construction to IS: 778 with screwed ends (Make-H.SARKAR / KARTAR/ KOLEY) a Size 25NB
C) AUTOMATIC SPRINKLER SYSTEM: Supply, erection, testing of MS black steel pipe Heavy Grade conforming to IS : 1239/3589 including all fittings viz. Elbows, tees, flanges, etc. reducer, clamps, included with joints complete with anticorrosive treatment to burried pipes by wrapping with 4mm thick PYPKOTE membrane applied over a coat of primer for external yard hydrant network. (Make-TATA,JINDAL) b 150 mm NB
Supply, fabrication, erection & testing of MS black steel pipe Heavy grade conforming to IS : 1239/3589 including all fittings viz. Elbows, tees, flanges, etc. reducer, clamps, MS support dash fasteners etc. including painting the pipe with two coats of approved red oxide primer and two coats of approved red enamel paint and welded joints complete with cutting and making good the walls, floors or any other surface. (Make-TATA,JINDAL) a 150 mm NB
b 100 mm NB
c 80 mm NB
d 65 mm NB
e 50 mm NB
f 40 mm NB
g 32 mm NB
h 25 mm NB
Supply & fixing of Sprinkler Head (Make-HD FIRE, TYCO, VIKING) a Pendent type
b Side wall type
Supply,Erection and testing of Installation Control Valve complete with trims & gong. . (Make-HD FIRE, TYCO, VIKING) a Size 150 mm NB
b Size 100 mm NB
Supply, installation, testing & commissioning of CI Gate Valve as pe IS:14846 (PN 16) with matching flanges complete with nuts & bolts. (Make-H.SARKAR / KARTAR/ KOLEY) a Size 150 mm NB
b Size 100 mm NB
c Size 80 mm NB
Providing & fixing Non return valve (Wafer type) with matching flanges complete with nuts & bolts. (Make-H.SARKAR / KARTAR/ KOLEY) a Size 150 mm NB
b Size 100 mm NB
c Size 80 mm NB
Providing & fixing Butterfly valve as per BS :5155 (Wafer type) matching flanges complete with nuts & bolts (Make-H.SARKAR / KARTAR/ KOLEY) a Size 150 mm NB
b Size 100 mm NB
c Size 80 mm NB
Providing & fixing Flow Switch (MAKE-HONEYWELL, SYSTEM SENSOR)
Supply & installation of automatic 25 NB Air Release Valve (Make-H.SARKAR / KARTAR/ KOLEY)
Supply & installation of Globe Valves in S.S Construction to IS: 778 with screwed ends (Make-H.SARKAR / KARTAR/ KOLEY) a Size 40NB
b Size 25NB
D. PORTABLE EXTINGUISHERS: Supply & fixing of 6 Kg ABC type dry power extinguisher consisting of welded MS cylindrical body with discharge valve, nozzle and hanging arrangement complete conforming to IS:15683 (Make-MINIMAX / FIRESHIELD / SAFIEX)
Supply & fixing of 9 Litre Water type CO2 (ISI marked) extinguisher including all accessories with wall bracket & raw plug conforming to IS:15683 (Make-MINIMAX / FIRESHIELD / SAFIEX)
Supply & fixing 4.5kg CO2 type (ISI marked) extinguisher including all accessories with wall bracket & raw plug confirming to IS:940 (Make-MINIMAX / FIRESHIELD / SAFIEX)
Supply & fixing 9 Litre Foam type (ISI marked) extinguisher including all accessories with wall bracket & raw plug confirming to IS:15683. (Make-MINIMAX / FIRESHIELD / SAFIEX)
Supply, erection, testing & commissioning of Optical type Smoke Detector (MAKESYSTEM SENSOR, ASES, RAVEL)
Supply, erection, testing & commissioning of analogue addressable Multicreteria Detector (MAKE-HOCHIKI, NOTIFIER, BOSCH)
Supply, erection, testing & commissioning of analogue addressable Heat Detector (MAKE-HOCHIKI, NOTIFIER, BOSCH)
Supply, erection, testing & commissioning of analogue addressable Mannual Call point (MAKE-HOCHIKI, NOTIFIER, BOSCH)
Supply, erection, testing & commissioning of Hooter (MAKE-HOCHIKI, NOTIFIER, BOSCH)
Supply, erction, testing & commissioning of analogue addressable Control Module (MAKE-HOCHIKI, NOTIFIER, BOSCH)
Supply,erection, testing & commissioning of analogue addressable Isolator Module (MAKE-HOCHIKI, NOTIFIER, BOSCH)
Supply, erection, testing & commissioning of analogue addressable Monitomodule (MAKE-HOCHIKI, NOTIFIER, BOSCH)
Supply, erection, testing & commissioning of Beam Detector (MAKE-HOCHIKI, NOTIFIER, BOSCH)
Providing & fixing ARMOURED CABLING complete with lugs, laying and termination of both ends. (MAKE-POLYCAB, MESCAB) a 2C x 1.5 mm2
F PUBLIC ADDRESS SYSTEM: Supply, erection, testing & commissioning of 6 Watt Ceiling mounted Speakers (MAKE-ASES, AHUJA,BOSCH)
PA console with microphone for annuncement. (MAKE-RAVEL, ASES, AHUJA)
Supply, erection, testing & commisssioning of 600watt Amplifier (MAKE-REPUTED)
Providing & fixing ARMOURED CABLING complete with lugs, laying and termination of both ends. (MAKE-POLYCAB,MESCAB) a 2cx1.5sqmm pa cable
G. SIGNAGES: Supply and installation in position the "FIRE EXIT" Sign with luminicent colour having size 300 x 100 mm.
Supply and fixing in position the signages " FIRE ORDER" contain the following matter on 3 mm thick "Opaque" PVC foam board of computerised cut, PVC nonreflective self adhesive vinyle painted foam board of size 1200 x 1000 mm. a ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATION. b EVACUATE THE OCCUPANTS BY USING FIRE EXIT AND EMERGENCY EXITS ONLY AND ASSEMBLE AT ASSEMBLY POINTS. c BE CALM AND DO NOT GET PANIC, WALK DO NOT RUN
Supply and fixing signage with printed " IN CASE OF FIRE, DO NOT USE LIFT. USE STAIRS ONLY" OF 1.5 cm height letters in red with white background. The size of the board shall be 300 x 250 mm and shaall be fixed at the height of 2 mtrs.from finished floor near Manual Call Point.
Shapoorji Pallonji and Company Private Limited
NCC Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid