Loading…
Loading…
Tender Value
₹5.7 L
EMD Value
₹5,681
Closing Date
13 Oct 2026, 4:00 pm5d left
Deputy Executive Engineer, Electric (R&B) Sub Division, Rajkot.
Replacing Old & u/s Led Tubelight , Ceiling Fan , Modular / Tissino type Accessories in Various Department of Government Polytechnic College at Rajkot.
351074
13-10-2026 16:00
Open
Electrical Works
Works
Rajkot
9 documents required · 8 mandatory · 1 optional
₹900
Deputy Executive Engineer, Electric (R and B) Sub Division, Rajkot.
₹5,681
1 Oct 2026
1 Oct 2026
1 Oct 2026
13 Oct 2026
1 Oct 2026
Name of work: Replacing Old & u/s Led Tubelight , Ceiling Fan , Modular / Tissino type Accessories in Various Department of Government Polytechnic
College at Rajkot.
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
In Figures In Word
Qty. Unit estiamted
Replacing Old & u/s by Point wiring for Light / Bell with 2-
1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 kV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length , in below type of pipe erected with
6A Modular type switch / bell push & accessories and earth
Rupees Five Hundred
continuity of following type, erected on PVC /
1 17.00 Pt. 539.34 ThirtyNine Paise
Metallic/Wooden box, single mounting base frame covered
ThirtyFour Only
with textured/metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed.(a) with
medium class Rigid PVC pipe and accessories erected flushed
on wall/ceiling complete Cat. III
Replacing Old & u/s by Point wiring for FAN with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 kV Grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe erected
with 6A Modular type switch and hum free EME step type
electronic fan regulator mounted and accessories with earth Rupees Seven Hundred
2 6.00 Pt. continuity of following type erected on PVC / 765.58 SixtyFive Paise FiftyEight
Metallic/Wooden box, single mounting base frame covered Only
with textured/metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected. with necessary ceiling rose
/ H.D.Connector as directed. (a) with medium class Rigid PVC
pipe and accessories erected flushed on wall/ceiling complete
Replacing Old & u/s by Providing and erecting Mains with
kV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected
concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper Rupees One Hundred Four
conductor FRLS PVC insulated stranded wire of green colour Paise Three Only
for earth continuity of following size (A) With medium class
Rigid PVC pipe and accessories (b) 2 wire 2.5 sq. mm
Point wiring for Individual Plug with & earth wire of
sq.mm (Green) both are of ISI marked 1.1 kV grade FRLS
PVC insulated multi strand copper wires up to 10 mtr length, in
below type of pipe erected complete with Modular type switch
& 5 pin Plug erected on PVC / Metallic/Wooden box covered Rupees Eight Hundred
4 3.00 Pt. with appropriate front plate modules erected on / in wall / 853.45 FiftyThree Paise
ceiling as per pipe erected with following type of FourtyFive Only
accessories.[II] For 16A Plug and 16 amp switch with 2-2.5
sq.mm Cu. Wire from mcb db board. (a) with medium class
Rigid PVC pipe and accessories erected flushed on wall/ceiling
complete Cat. III
Replacing Old & u/s by Supplying and erecting LED indoor
fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high U.V. & corrosion
resistance with diffuser with company mark/name 160V to
270V, Power Factor more than 0.95, THD < 15%,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Tube Light with integral driver (v) 36-40 Watts, Surge-2 Rupees Five Hundred
170.00 Ea kV, IP-20, conventional 4 feet (v) 36-40 Watts, Surge-2 kV, IP- 535.30 ThirtyFive Paise Thirty
20, conventional 4 feet Only
Replacing Old & u/s by Providing following type of Modular
Type Accessories mounted with PVC / metallic/Wooden box,
single mounting base frame covered with textured / Rupees One Hundred
metallic/white front plate , modules erected with necessary FiftyOne Paise Fifty Only
connections as per site situation directed by Engineer In
charge.(1)One No. SP 6 Amp.Cat.III
(2) One No 5 pin plug Cat.III Rupees One Hundred
FiftyOne Paise Fifty Only
(5) Electronic hum Free steps EME Fan regulator Cat.III Rupees Three Hundred
100.00 Ea 398.95 NinetyEight Paise
NinetyFive Only
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
In Figures In Word
Qty. Unit estiamted
Replacing Old & u/s by Providing & Erecting following
Shockproof tissino type accessories erected on 3 mm thick PC
Rupees ThirtyOne Paise
7 350.00 Ea (Polycarbonate) sheet in PVC/ Metal/Wooden Box. erected 31.31
on wall/ ceiling.(1) One no Single pole 6 A Switch / Bell push
(2) One no 3/5 pin 6 A Socket Rupees ThirtyOne Paise
(14) Electronic Hum free EME Socket Type Steps Fan Rupees Two Hundred
110.00 Ea Regulator 219.17 Nineteen Paise Seventeen
Replacing Old & u/s by Providing & erecting water cooler
having storage capacity 150 Ltr. & cooling capacity 150 Ltr.per
hour @ an ambient temp of 45˚ C. The outlet temp. of the
water should drop by 15˚C within a hour, The water cooler Rupees SixtyOne
should be comprising of hermetically sealed compressor, fan Thousand Four Hundred
motor, condensing unit, water tank surrounded by evaporating, EightyTwo Paise
coil, thermostats, relay etc.complete with necessary inlet & SeventyFour Only
outlet connection. The body of water cooler will be made from
Stainless Steel and ISI Certified.
Supplying & erecting approved make low noise decorative Rupees One Thousand
9 9.00 Ea exhaust fan having square frame ABS body with inbuilt lowers 1703.87 Seven Hundred Three
& square frame. 250mm with 1350 RPM Cat.II Paise EightySeven Only
Replacing Old & u/s by Providing & erecting Approved make
Power Saving 45 - 50 Watt Ceiling Fan with double ball
Rupees One Thousand
bearing ISI mark with Condenser 230 volt A.C. 50 Hz
10 88.00 Ea 1948.29 Nine Hundred FourtyEight
mm sweep complete having 3blades with aluminium blades
Paise TwentyNine Only
with , canopy & 30 cm. down rod erected with earthing.(Make
shall be approved by Engineer in charge))
Rupees Five Lakh SixtyEight Thousand SeventyEight Paise FiftyFour Only
Note:- The Credit of dismentalled materials for Rs.22421.00 shall be recovered from the First R.A. bill payable to the contrator and there after the
dismentalled materials shall be the property of the contractor.
I/We am/are willing to carry out the work at__________________% above/below (in figures)_____________________________________percent Above / below (in
words) the estimated rates mentioned above amount of my\our tender works out as under :-
Estimated amount put to Tender Rs. _________
Deduct________% below Rs. _________
Net Amount Rs. _________
Estimated amount put to Tender Rs. _________
Net Amount Rs. _________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local situation regarding material,labour and
other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications and other tender documents of this
work and agree to execute the same accordingly.
C Any Excess in Tender Item/Extra Item if Needs to be Execute. Contractors has to carry out work on the instruction of Competant Authority on
Tender Submitted rate,No Excuse will be Accepted.Hence Contractor are Requested to quote the rate considering this condition.
D Contractor are requested to quote the Tender by considering that payment will be made after availibility of grant.Contractor has to start the work
immediately after issue of Work Order and as per instruction of Engineer-in-Charge irrespective of availibility of grant.
E "This estimate has been prepared on the new SOR wich is exclusive of GST hence GST additional will be paid to the agency as per existing
(Signature of the Contractor) Deputy Executive Engineer
Electrical R&B Sub Division
Executive Engineer
Electrical R&B Division
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be considered as final.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Contractor_Registration_Paripatra__1_.pdf
GR for Extra Item.pdf
GR for single Tender.pdf
SD EMD GR 25-26.pdf
ONLINE_NOTICE(R-2).pdf
SBD.pdf
SCH-B.pdf
MAKE FOR ELECTRICAL ITEM.pdf
DM.pdf
ANNEXURE-A.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .