| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 CrAccepted-AOC 17 22 AMAR CHAKRABORTHY ROAD P O KHAGRA DIST MURSHIDABAD 742103 | MURSHIDABAD | WEST BENGAL | 742103 | ₹11.7 Cr | L1 | Accepted-AOC Accepted as L1 Bidder |
| 2 | L2₹12.0 CrRejected-Finance NOT AVAILABLE | NA | NA | 121004 | ₹12.0 Cr | L2 | Rejected-Finance Rejected due to L2 Bidder and Financially Disqualified |
| 3 | L3₹12.1 CrRejected-Finance PURBA BARDHAMAN | HOOGHLY | WEST BENGAL | 712134 | ₹12.1 Cr | L3 | Rejected-Finance Rejected due to L3 Bidder and Financially Disqualified |
| 4 | Rejected-Technical KALIKA DAS ROAD PATAKURA P O DIST COOCH BEHAR PIN 736101 | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | - | - | Rejected-Technical Not Complied with Technical Specification |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Complied with Technical Specification |
Tender Value
₹11.4 Cr
EMD Value
₹22.9 L
Closing Date
19 Jan 2026, 1:00 pmClosed
Sr. Superintending Engineer
Shilpa Bhavan, 31, Black Burn Lane, Kolkata- 700012
Development of Civil and Electrical Infrastructures of Dabgram Industrial Park, Phase-IV in the district Jalpaiguri.
2025_MSMET_980100_1
NIET 32 of 2025-26
Open Tender
CIVIL AND ELECTRICAL WORKS
365 days
Dabgram Phase IV
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,800
₹22.9 L
Shilpa Bhavan
17 Feb 2026
26 Dec 2025
20 Jan 2026
27 Dec 2025
19 Jan 2026
27 Dec 2025
8 Jan 2026
TOTAL
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared)
Earthwork in filling in compound, tank, low land, ditchesetc.withgoodearth, in layersnot exceeding 150mm. cludingbreakingclodsandconsolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work) (a) With carried earth arranged by the contractor within a radius exceeding 5km.but not exceeding10 km. including cost of carried earth
Boundary Wall and gate
Earth Work in excavation for foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required.
Depth of Excavation not exceeding 1500mm
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplyingand laying Polythene Sheet (150gm/ sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. a) Pakurl Variety
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (a) Pakur Variety
In Ground floor including roof
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
25 mm to 30 mm shuttering without staging in foundation
Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
In foundation and ground floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction (i) Tor steel/Mild Steel . A.JSW/JSPL/SHYAM/SRBM/BMASL/ELECTRO STEEL/SSI
For works in foundation and upto roof of ground floor/upto 4 m
Brick work with 1st class bricks in cement mortar (1:6)
In Foundation and Plinth
125mm. Thick brick work with1st class bricks in cement mortar (1:4) in ground floor
In Ground floor
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) .(a) With earth obtained from excavation of foundation
Labour for Chipping of concrete surface before taking up Plastering work.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
With 1:6 cement mortar (a) 20 mm thick plaster
In Ground floor including roof
Neat cement punning about 1.5mm thick in wall, dado,window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.
Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof
For structural members of specified sections weighing less than 22.5 Kg./m
Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc.)
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.
Grill weighing above 16 Kg./sq.mtr and above
For Grill Gates
For supplying fitting and fixing bottom rollers including all labour comple
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials
Iron parliamentary hinges conforming to IS 362-1982 fitted and fixed complete with steel screws (a) 150mm. X 125mm. X 27mm. X 2.50mm
Supplying, fitting, fixing in position rails on any surface.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) Two Coat
In Ground floor
Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (a) Two Coats
In Ground floor
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary
a) With super gloss (hi-gloss), with any shade except white &black . 2 Coats
On steel or other metal surface : With super gloss (hi-gloss). Two coats (with any shade except white
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof.
Labour for taking out (from fencing) line of wire (galvanised, strand or barbed) by drawing the same out through holes in the body of the post or through holes formed by fixed staples.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with theMunicipal / Corporation Rules for such disposal, loading into truck and cleaning the site inall respect asper direction of Engineer in charge
2 Nos. Security Room
Earth Work in excavation for foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required.
Depth of Excavation not exceeding 1500mm
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. a) Pakurl Variety
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (a) Pakur Variety
In Ground floor including roof
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
In foundation and ground floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction . (i) Tor steel/Mild Steel . A.JSW/JSPL/SHYAM/SRBM/BMASL/ELECTRO STEEL/SSI
For works in foundation and upto roof of ground floor/upto 4 m
Brick work with 1st class bricks in cement mortar (1:6)
In Foundation and Plinth
In Super Structure, ground floor
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
With 1:6 cement mortar, 20mm thick
In Ground floor including roof
With 1:4 cement mortar, 10mm thick
In Ground floor including roof
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS:732-1983andIS:1285-1975;Annodized (with required film thickness and specified colour/natural)matt finished conforming to IS:1868-1983for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed/certified make and brand as per direction of Engineer-In Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film, Natural white ( K ) Movable door shutter
Door frame. (Top & sides)
Shutter :
Top Rail
Bottom Rail
Lock Rail
Door Vertical
Glazing Clips
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)
4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating)
Supplyingand laying Polythene Sheet (150gm/ sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white . For 2- Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (a) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr
In Ground floor
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:
225mm long x 10mm dia. bolt
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete
With continuous plate base (Hexagonal/ Round rod). 150 mm grip x 10 mm dia rod.
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws (a) 125 x 75 x 4.0mm
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987
4mm thick clear glass
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) . (a) 40mm X 6mm, 125mm Length
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. (a)35mm thick.
In Ground Floor
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
In Ground Floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)
2 Coats : Water based interior grade Acrylic Primer
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) Two Coat
Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (a) Two Coats
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary
a) With super gloss (hi-gloss), with any shade except white &black . 2 Coats
On steel or other metal surface : With super gloss (hi-gloss). Two coats (with any shade except white
Road Net Work
Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary.
Depth up to 150 mm
For each additional Depth of 150mm and part thereof.
Construction of granular sub-base by providing graded material, mixing by mix in place method with Rotavator at OMC, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials,machinery, tools and plants including cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision ), N.Bengal Variety ( Ethalbari Variety ) ( Stone Chips)
Grading - III
Grading - V
Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including screening of aggregates and granular materials, premixing the material with water at OMC in Wet Mix Plant, carriage of mixed material by tipper to site, laying in uniform layers with Paver in Sub- base / Base course on well prepared surface and compacting with Vibratory Roller to achieve the desired density, including supply of all materials, machinery, fuel and lubricants, including incidental costs for lighting, guarding, barricading, making earthen bundh to protect the edges including cost of quality control complete as per Clause 406 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (a) N.Bengal Variety ( Ethalbari Variety) ( Stone Chips)
Cast in Situ Cement Concrete M20 Kerb : Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (The rate is inclusive of cost of all materials, labour, hire and usage charges of machinery and all incidental charges in this connection.) (a) Using Concrete Mixer
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
Supplying and laying in the specified pattern of interlocking concrete block pavements (ICBP) with concrete blocks ( with concrete grade as specified as per Table-I of IS 15658:2006) manufactured from BIS licensed manufacturer, with spacer nib ( small protruding profiles on the vertical face of paver block used as a device for keeping minimym joint gap in between the paving blocks, as per C.I No- 3.26 of IS:15658 ) and of specified size and shape with aspect ratio ( the ratio of length to thickness of a Paver block, as per C I No - 3.3 of IS : 15658) as per table - II of I.S : 15658 with flexural strength / breaking load as per Annexure G of I.S: 15658, on the prepared base course of specified CBR as per Table-I of IRC SP 63 ( 2018 ) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25 to 35 mm thick ( grading of the bedding sand as per clause 6.5.1 of IRC SP 63) and filling up the gaps in between paver blocks with joint filling sand ( the grading of the joint filling sand will be as per clause 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per C I No 8.7 of IRC SP 63 (2018) with proper confindment of bedding and joint filling sand, compaction, levelling and filling up of the edge gap..
80mm thick, Grey
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary
With super gloss (hi-gloss), with any shade except white. 2 Coats
On timber or plastered surface
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
80 mm x 60 mm rectangular
60 cm x 60 cm square
Water Supply
Earth Work in excavation for foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required.
Depth of Excavation not exceeding 1500mm
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 :
150 mm dia Ductile Iron Double Flanged
100 mm dia Ductile Iron Double Flanged
Supplying, fitting and fixing cast iron spun pipe conforming to I.S. 1536/1976 with all necessary specials including cutting trenches in any soil or through masonry, concrete etc., if necessary,and mending good all damages including jointing pipes with Tyton joints as per manufacturer's specifications and filling up the trenches all complete but excluding the cost of masonry or concrete work, if required.
Class-B, 80mm Dia
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
C.I. sluice valve with flanged ends drilled to as per I.S. 1358/62 and having all cast iron components as per I.S. 780/71 solid forged bronze inside screw spindle having ultimate tensile strength not less than 4.72 MT per sq. cm.Spindle nut valve and seat faces of hard wear resisting, anufactured from best quality gunmetal conforming to I.S. 780/71, painted black all over with asphalt base paint tested to 21 kg (hydraulic pressure) per sq. cm., valve opening to anticlockwise direction, fitted and fixed complete.
Sluice valve chamber with C.I. heavy cover with locking arrangement, (weight not less than 25 kg) (size of chamber 450 mm X 600 mm inside upto 900 mm depth) 250 mm thick cement brick walls (6:1), 150 mm thick cement oncrete (6:3:1) bed with stone chips, 20 mm thick cement plaster (6:1) for inside wall and 15 mm thick cement plaster (4:1) for outer walls including rounding corners.
Drain Net Work
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete
Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. a) Pakur Variety
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (a) Pakur Variety
In Ground floor including roof
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
In foundation and ground floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction (i) Tor steel/Mild Steel . A.JSW/JSPL/SHYAM/SRBM/BMASL/ELECTRO STEEL/SSI
For works in foundation and upto roof of ground floor/upto 4 m
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
With earth obtained from excavation of foundation
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
With 1:6 cement mortar, 20mm thick
Labour for Chipping of concrete surface before taking up Plastering work.
Neat cement punning about 1.5mm thick in wall, dado,window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
2 Nos. Depth Tube Well
Electro-logging charge.
Site Preparation, Temporary Latrine, Placement & levelling of Rig Machine, Mast hoisting and Casing drilling (Upto 6 mtr.) Placement of Casing with all allied works necessary to commence drilling woks and wind up of all machineries after completion of Drilling.
Drilling borehole by Rig machine with Odex-165 (Simultaneous driving of casing pipe) method of drilling through any kind of soil, boulder, rock etc. upto the required depth. This item includes the cost of hiring of Rig machine, Compressor, Supporting vehicle and other machinery & equipments with operators, drivers, laborers etc. Proportionate cost of drilling tools and accessories such as Hammer, Pilot bit, Reamer bit, G uide device, Guide sleeve etc.Cost of consumable materials like fuel & lubricants, electrode for welding, any other related equipment, materials and service etc.
GL to 60 mtr
60 mtr. to 100 mtr.
100 mtr. to 120 mtr.
Supply and Delivery of 125 mm dia LCG/HDPE/other suitable filter
Supply and Delivery of 183 mm ID/196 mm OD MSERW fin cut pipe
Lowering and placing of filter assembly of required length and Extraction and partening off the casing pipe of required length.
Mobilisation and transportion of the Rig machine and its accessories and others materials, etc. to the site.
Supply and Delivery of Bit tube (1.5mtr. Long) for Odex-165
Supply and Delivery of Casing Shoe (for Odex-165)
Packer Assembly (for Odex-165)
Supply and Delivery of MS TW Specials (Clamp, Cap, Bail plug,Lugs, Ring etc.)
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete. Note: Initial 6 m. of Annular space between the housing pipe and the bore should not be shrouded with Pea size gravel to avoid contamination with surface water.
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.
Development of the tubewell by Air Compressor and BHT/ other suitable pump and Yield Testing by BHT/ other suitable pumping machinery upto the satisfaction of EIC. It includes arrangement of all machinery, s upply of fuel & lubricants, laborers, any others etc.
Water sample collection and chemical test including Arsenic Test.
U G R (For Fire) & Pump Room
Earth work in excavation of foundation in all sorts of soil in dry and wet condition including necessary protection for earth retention of the sides of the excavated area, removal as required, complete as per specification and direction of Architect/Employer. Depth up to 1.5 m.
Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring
Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete.(Payment to be made on basis of measurement of finished quantity of work). With earth obtained from excavation of foundation.
Filling in foundation or plinth by fine sand in layers not exceeding 150mm as by thorough saturation with water, ramming complete exceeding 150 mm as directed and consolidating the same including the cost of supply of sand. (Payment to be made on measurement of finished quantity)
Anti termite Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS-6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).
Supplying & laying 250 micron polythene sheeting below P.C.C & between brick shuttering and concrete.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. a) Pakur Variety
Hire and labour charges for shoring work (including necessary close plank walling, framing,Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge).
Depth upto 1.5 m.
For additional depth beyond 1.5 m. and upto 3.00 m
Brick work with 1st class bricks in cement mortar (1:6)
In Super Structure, ground floor
125mm. Thick brick work with1st class bricks in cement mortar (1:4) in ground floor (a) In Ground floor
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(a) Pakur Variety
In Ground floor including roof
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs , beams, columns , lintels curved or straight including fitting , fixing and striking out after completion of works. (A) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work, In foundation and ground floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction . (i) Tor steel/Mild Steel . A.JSW/JSPL/SHYAM/SRBM/BMASL/ELECTRO STEEL/SSI
For works in foundation and upto roof of ground floor/upto 4 m
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 30 Grade (a) Pakur Variety
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white . For 2- Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (a) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr
In Ground floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (a) Sal : Siliguri
In Ground floor
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made)
40mm thick shutters with 19mm thick panel of size 30 to 45 cm
Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement.
35mm thick
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
With 1:6 cement mortar, 20mm thick
With 1:4 cement mortar, 10mm thick
In Ground floor including roof
Labour for Chipping of concrete surface before taking up Plastering work.
Neat cement punning about 1.5mm thick in wall, dado,window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:
225mm long x 10mm dia. bolt
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete
With continuous plate base (Hexagonal/ Round rod). 150 mm grip x 10 mm dia rod.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987
4mm thick clear glass
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) . (a) 40mm X 6mm, 125mm Length
Supplying Aluminium casted body Butt Hinge (KOBRA type). (Natural white)
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
In Ground Floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)
2 Coats : Water based interior grade Acrylic Primer
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) Two Coat
In Ground Floor
Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (a) Two Coats
In Ground Floor
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. In all floors
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary
a) With super gloss (hi-gloss), with any shade except white &black . 2 Coats
On steel or other metal surface :
On timber or plastered surface
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 - For 110 mm dia
Single Socketed 3 Meter Length, 110mm dia
Supplying, fitting and fixing in position reinforced cement polymer concrete manhole /gully pit cover with matching frame.As per I.S-12592(M.D)
15 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of size Cover: 460 mm X 75 mm Frame: 620 mm X 150 mm opening: 360mm Weight: 100 kg (approx)
U G R Filter Water Tank & Pump Room
Earth work in excavation of foundation in all sorts of soil in dry and wet condition including necessary protection for earth retention of the sides of the excavated area, removal as required, complete as per specification and direction of Architect/Employer. Depth up to 1.5 m.
Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring
Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete.(Payment to be made on basis of measurement of finished quantity of work). With earth obtained from excavation of foundation.
Filling in foundation or plinth by fine sand in layers not exceeding 150mm as by thorough saturation with water, ramming complete exceeding 150 mm as directed and consolidating the same including the cost of supply of sand. (Payment to be made on measurement of finished quantity)
Anti termite Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS-6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).
Supplying & laying 250 micron polythene sheeting below P.C.C & between brick shuttering and concrete.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. a) Pakur Variety
Hire and labour charges for shoring work (including necessary close plank walling, framing,Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge).
Depth upto 1.5 m.
For additional depth beyond 1.5 m. and upto 3.00 m
Brick work with 1st class bricks in cement mortar (1:6)
In Super Structure, ground floor
125mm. Thick brick work with1st class bricks in cement mortar (1:4) in ground floor
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (a) Pakur Variety
In Ground floor including roof
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs , beams, columns , lintels curved or straight including fitting , fixing and striking out after completion of works. (A) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work, In foundation and ground floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction . (i) Tor steel/Mild Steel . A.JSW/JSPL/SHYAM/SRBM/BMASL/ELECTRO STEEL/SSI
For works in foundation and upto roof of ground floor/upto 4 m
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 30 Grade (a) Pakur Vatiety
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white . For 2- Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (a) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr
In Ground floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (a) Sal : Siliguri
In Ground floor
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made)
40mm thick shutters with 19mm thick panel of size 30 to 45 cm
Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement.
35mm thick
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
With 1:6 cement mortar, 20mm thick
With 1:4 cement mortar, 10mm thick
In Ground floor including roof
Labour for Chipping of concrete surface before taking up Plastering work.
Neat cement punning about 1.5mm thick in wall, dado,window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:
225mm long x 10mm dia. bolt
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete
With continuous plate base (Hexagonal/ Round rod). 150 mm grip x 10 mm dia rod.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987
4mm thick clear glass
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) . (a) 40mm X 6mm, 125mm Length
Supplying Aluminium casted body Butt Hinge (KOBRA type).(Natural white)
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
In Ground Floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)
2 Coats : Water based interior grade Acrylic Primer
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) Two Coat
In Ground Floor
Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (a) Two Coats
In Ground Floor
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. In all floors
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary
a) With super gloss (hi-gloss), with any shade except white &black . 2 Coats
On steel or other metal surface :
On timber or plastered surface
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 - For 110 mm dia
Single Socketed 3 Meter Length, 110mm dia
Supplying, fitting and fixing in position reinforced cement polymer concrete manhole /gully pit cover with matching frame.As per I.S-12592(M.D)
15 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of size Cover: 460 mm X 75 mm Frame: 620 mm X 150 mm opening: 360mm Weight: 100 kg (approx)
Pay & Use Toilet
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared)
Earth Work in excavation for foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required.
Depth of Excavation not exceeding 1500mm
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. a) Pakur Variety
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (a) Pakurl Variety
In Ground floor including roof
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
In foundation and ground floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction . (i) Tor steel/Mild Steel . A.JSW/JSPL/SHYAM/SRBM/BMASL/ELECTRO STEEL/SSI
For works in foundation and upto roof of ground floor/upto 4 m
Brick work with 1st class bricks in cement mortar (1:6)
In Foundation and Plinth
In Super Structure, ground floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) . In ground floor.
In Ground floor
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
With 1:6 cement mortar, 20mm thick
In Ground floor including roof
With 1:4 cement mortar, 10mm thick
In Ground floor including roof
Labour for Chipping of concrete surface before taking up Plastering work.
Providing and fixing factory made door frame (single rebate) made of single piece extruded solid PVC profile with homogenous fine cellular structure having smooth outer integral skin having 62mm width x 32 mm thickness (the door frame is to be made with single piece extruded solid pvc profile whereas no sheet pasted profile shall be applied for door frame fabrication) and shall be fixed to wall as per instructions of Engineer – in – charge using 100 x 8 sheet metal CSK screws
Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge.
Providing and fixing of factory made uPVC Louver window (White Colour) (U value=1.9-1.3 W/m 2 K, flame resistant, self extinguishing, lead free) comprising of uPVC multi-chambered with wall thickness of 2.3mm (±0.2 mm ) duly reinforced with 1.6 mm (±0.2 mm) thick G. I. Section made from roll forming process of required length (shape & size according to uPVC profile). Profile of frame & sash shall be mitred cut and usion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. Both vertical sides of the frame, adjustable louver mechanism having one lever shall be fitted with the provision of 4 mm glass. Window frame will be fixed to the wall with 100mm long and 8mm dia for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Fasteners and after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per as per approved drawing & direction of Engineer-in-Charge. (Note: Profile manufacturer & Window Manufacturer must be one & same, Only manufacturer Waranty is aceptable
a) Louver Window with provision of Exhaust Fan frame of size 67 x 62 mm & Sash / Mullion of size 67 x 78 mm both having wall thickness of 2.3 ± 0.2 mm
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (a) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr
In Ground floor
Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:
225mm long x 10mm dia. bolt
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws (a) 125 x 75 x 4.0mm
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete
With continuous plate base (Hexagonal/ Round rod). 150 mm grip x 10 mm dia rod.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987
4mm thick clear glass
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) . (a) 40mm X 6mm, 125mm Length
Levelling Course with Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (a) Pakur Variety
In Ground floor
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).
In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength > 1500 N
In Ground Floor
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
25 mm thick Tiles as per IS: 1237-2012 for footpath,ramp,staircase of public building(over 25 mm thick (Avg) Cement mortar (1:3) & Cement Slurry @ 4.4 kg/Sq.m at back side of Block. Cement for Mortar & Slurry to be supplied by Department.
Coloured Decorative
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc
On Wall . (a) With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile above 0.09 Sq.m (i) Coloured decorative
In Ground floor
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
In Ground Floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)
2 Coats : Water based interior grade Acrylic Primer
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) Two Coat
Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (a) Two Coats
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary
a) With super gloss (hi-gloss), with any shade except white &black . 2 Coats
On steel or other metal surface : With super gloss (hi-gloss). Two coats (with any shade except white
Labour for fitting and fixing high density poly-ethylene pipes or P.V.C. pipes for above ground work including cost of jointing materials paints etc. fitting and fixing all necessary specials, cutting pipes, making threads, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps(any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. )
Above Ground
15mm Dia
20mm dia
25mm dia
40mm Dia
Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007
CPVC Pipes Class-1,SDR-11
15mm dia
20mm dia
25mm dia
40mm Dia
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).
25mm dia
40mm Dia
Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand).
Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.
(a) E.W.C., Bestolite (solid type) black
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 - For 110 mm dia
Single Socketed 3 Meter Length, 110mm dia
Double Socketed 1.2 Meter Length- 110 mm dia
Door Tee. 110mm dia
Door Bend (T.S.) 110mm dia
110 X 110 P Trap
Shoe - 110 mm dia
Vent Cowl. 110mm dia
Pipe Clip. 110 mm dia
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials
Above Ground , 110mm dia
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.
635 mm X 395 mm X 420 mm
Supplying, fitting and fixing complete Bottle waste trap (Heavy Quality) (a) Chromium plated Bottle trap 32 mm with 190 mm long connecting pipe and wall flange (Equivalent to Code No. 545 & Model - Tropical /Sumthing Special of ESSCO or similar brand)
Supplying, fitting and fixing urinal flush pipe fittings of approved brand.
C.P. urinal flush pipe fittings range of one
Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets
610 mm X 450 mm X 250 mm-
Roman brown, Fern green, Misty lilac, Orange, Sienna gold, Silver grey, Sepia, Alpine, Cornil sorvinto blue
Supplying, fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excluding concreting at bottom and sides).
150mm dia
225mm dia
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.
i) With N.Bengal variety (Other than SAIL/TATA/RINL).
Extra for each additional depth of 150 mm or part thereof beyond initial 600 mm depth
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only).
900 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 150 mm dia. of approved make A) With N.B Variety (Other than SAIL/TATA/RINL)
Supplying, fitting and fixing S.W. master trap.
225 mm X 225 mm
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer
2000 litre capacity
Labour for hoisting plastic water storage tank.
Above 1500 litre upto 5000 litre capacity.- Upto 1 story
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover (heavy type) of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C (1:1.5:3) bottom slab including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and refilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.
For 50 Users , (a) With N.B Varity Stone chips (Other than SAIL/TATA/RINL)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia.
Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges
2 Nos. Culverts
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete
Depth of excavation not exceeding 1,500 mm.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (a) Pakur Variety
In Ground floor including roof
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 30 Grade a) Pakur Variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
In foundation and ground floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction . (i) Tor steel/Mild Steel . A.JSW/JSPL/SHYAM/SRBM/BMASL/ELECTRO STEEL/SSI
For works in foundation and upto roof of ground floor/upto 4 m
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
With earth obtained from excavation of foundation
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m. In ground floor including roof (a) Upto 150mm thick
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof.
Brick work with 1st class bricks in cement mortar (1:6)
In Foundation and Plinth
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
With 1:6 cement mortar, 20mm thick
Labour for Chipping of concrete surface before taking up Plastering work.
Supplyingand laying Polythene Sheet (150gm/ sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Neat cement punning about 1.5mm thick in wall, dado,window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Electrical works
Supply of HDPE Pipe conforming to IS - 4984 - 1985 [PE - 63] (6kg/sq cm): 63mm (Dia) (Make: Supreme/Oriplast/Ashirbad as appd by EIC) & laying underground trench 460 mm wide x 760 mm average depth, including filling the trench with shifted soil, leveling up and restoring surface duly rammed
Supply of HDPE conforming to conforming to IS - 4984 - 1985 [PE - 63] (6kg/sq cm) : 40 mm Dia (Make: Supreme/Oriplast/Ashirbad as appd by EIC) & laying underground trench 460 mm wide x 760 mm average depth, including filling the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
For 4 core 10 sqmm
For 4 core 35 sqmm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc.
For 4 core 10 sqmm
For 4 core 35 sqmm
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Installation the feeder pillar box only on cement brick foundation including plastering and neat cementing as per specification and direction of E.I.C. b) For large size feeder pillar box. (drawing to be approved by EIC)
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
100 mm Dia.
50 mm Dia.
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete.for supporting the pipes
Supply of G.I Flange with suitable arrangement & necessary nuts, bolts & washers.
Supply & fixing C.I. 80 mm non-return valve. (Make: Approved by EIC)
Supply & fixing of pressure gauge with Syphon Bends. (Make: Approved by EIC)
Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required: 32 mm dia
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Supplying and fixing (2+4 way) double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Incl Supply & fixing of Incomer: 40 A DP MCB with breaking capacity of 10kA, Outgoing: 4 Nos. 6 A SP MCB with breaking capacity of 10kA on DIN rail (Legrand)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug (make:Legrand/Cabtre/ siemens) point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC (Make: Finolex/Polycab/Havells as approved by EIC) (ON BOard)
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.a) 16 sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.a) 6 sqmm
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. Average run 6 mtr.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Distribution wiring in 2 x 2.5 sq mm + 1 x 1.5 sq mm sigle core stranded FR PVC insulated & un-sheethed copper wire (Make: Finolex/Polycab/Havells as approved by EIC) in 19 mm bore 3 mm polythene pipe concealed in wall as per direction of EIC. For room SPN DB to 15 A Power Plug.
Earthing with 50 mm (2" dia) galv GI pipe 3.64mm thickness x 3.04 m long and suitable size GI clamp continously welded around the earth electrode and earth lead of GI strip of size (19 mm x 3 mm, 4 mts long) after connecting them by 13 mm dia x 80 mm long GI bolt double nut. Double washers incl S/F 15 mm dia GI pipe protection (1 mtr long) to be filled with bitumen partly under the ground level an partly above ground level to an avg depth of 3.65 mtr below the ground level as below. a) by TATA-M GI pipe.
Supply and fixing sheet steel main switches on angle frame on wall 32 Amp, 415 V front handle TPN with fuse on L & N (Make- L&T /Havells).
Supply and fixing sheet steel main switches on angle frame on wall 32 Amp, 240 V front handle DP with fuse on L & N (Make- L&T /Havells).
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
S&F Compression Type brass cable gland as to GS as follows: 4 Core 16 sq.mm. PVC Al. armoured cable
S&F Compression Type brass cable gland as to GS as follows: 2 Core 10 sq.mm. PVC Al. armoured cable
S&F finishing end of the cable socket by crimping method as to GS as follows: 4 Core 16 sq.mm. PVC Al. armoured cable
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991): 4 bars 415 V, 63 A Al. Busbar
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.): 80 mm dia (Make: Approved by EIC)
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. 6SWG
Supply And drawing 2 x1.5 sqmm. copper wire for LED module connection and SMPS connection.+2 Nos board (Finolex/Polycab/Havells as approved by EIC)
S&F finishing end of the cable socket by crimping method as to GS as follows: 2 Core 10 sq.mm. PVC Al. armoured cable
WBSEDCL Service Connection Charge for three nos. of supply meters(two(2) for pump houses and one(1) for street lighting arrangement of adequate capacity within the premises ) (in co-ordination with the WBSEDCL and WBSIDCL (Please refer Cl 19 of NIET)
Shifting Charges of existing WBSEDCL infrastructure including HT/LT pole, (Please refer Cl 19 of NIET)
Erection of new WBSEDCL Infrastructure including HT/LT poles ,cable ,transformer , feeder piller.(Please refer Cl 19 of NIET)
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Providing 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70mm A/F, sheet thickness 4mm on provided foundation including Foundation bolts (TS-600) Make-Bajaj/Volmount/Transrail as approved by EIC
Foundation & erection of single 8 m octagonal pole with RCC foundation (Proportion & dimension indicated below) (Base: 1200x1200x375 mm; Column: 450x450x1500 mm) thick RCC ( 3:1.5:1) base block below sole pole with hard jhama metal incl RCC 4:2:1 (muffing 0.30 mtrs above ground level incl, 3mm thick neat cemented finish) as per the drawing approved by the EIC
Supply & delivery of 3 C x 1.5 sq. mm. PVC Copper Cable (Make :- KEI/Polycab/Gloster as approved by EIC)
Supply and fixing of All In One Solar LED Street Light of 80W (Lumen output not less than 10500 lumens) on existing Steel Tubular Poles having following specifications:- Solar Panel: 1. Solar panel should be made from Monocrystalline cells. 2. The Solar Module Power shall be ≥ 100 Wp. 3. Cell efficiency should be≥21% . 4. Operation Mode: Hybrid 5. Module efficiency should be ≥17% . 6. Glass should be Borosilicate only . 7. Manufacturer should comply to IEC 61215, IEC 61730 & IEC 61701 standards.
Lighting Luminaries: 1. The Lumens Output of the Fitting shall be of Minimum 10500 Lumens. 2. LED should be of Osram/ Lumiled/Cree/Seoul/ Nichia/ Bridgelux 3. LED Type: High power SMD LED, Gen 5 4. LED Efficacy: 171lm/W 5. CRI should be >70 6. CCT should be 5700K±500K 7. System Efficacy ≥150 lm/W 8. Aluminium heat-sink to be used 9. LEDs shall have optical grade polycarbonate lens to provide streetlight distribution. LED optical lens should be mechanically fixed to MCPCB and should not be fixed by glue. Individual or cluster of LEDs should be provided with Optical Grade Polycarbonate lens with streetlight (Type II) optical distribution 10. The LED shall be compliant with LM80-08 standard. 11. Useful LM70 life of 50000 Hrs with 70% lumen maintenance at 35 deg C ambient temperature. (Complete LM 80 test report for LED should be submitted) 12. Product should be IP 65 at component level.
Battery: 1. Battery pack should be of LiFePO4 type cells 2. Life of battery should be ≥2000 cycles @ 80% DoD 3. Battery backup: ≥10 hours in full power mode≥30 hours in saving mode (30% light output throughout) (Battery fully charged condition) 4. Battery size: 12.8V, 60Ah 5. Battery should have wide operating temperature range (0 to ≥45 degree celcious) to work in higher ambient 6. Cells used in battery pack should have BIS/IEC certification as per IS 16046/IEC 62133.BIS certificate to be provided for cell. 7. Battery BMS should have over temperature, over voltage, under voltage & short circuit protection 8. Battery pack should have a FR sheet packing with HS sleeve 9. Battery pack should have IP66 protection.
Electronics: 1. Should have MPPT algorithm for charging. 2. MPPT tracking efficiency: >98% 3. MPPT Conversion efficiency: >95% 4. LED driver efficiency: >90% 5. Reverse Polarity, Short circuit, LED open, LED short circuit, open circuit protection 6. Reverse current flow protection 7. Standby current consumption Should be <20mA 8. Should have indications for Charging, LVD, Status of system 9. Electronics should comply with IEC/BIS standards 10. Product should be IP 65 on component level 11. Wide operating temperature range: 0 to 55 degrees 12. MPPT, Driver & PIR sensor should be potted 13. Status indications to be provided for Charging, Battery full, Product status, Battery low, Over temperature.
Mechanical: 1. Housing material should be made up of Aluminium Extrusion/sheet 2. Manufacturer Logo to be embossed on housing 3. Metallic silver powder coating with thickness of ≥70 micron 4. ≥5mm thick, Hot dip galvanised & powder coated hardware for pole mounting 5. Robust pole mounting clamps to handle high wind pressure 6. All screws and nuts should be SS 304 grade 7. IP 67 -Soft switch for ON/OFF operation 8. Fixed 5-degree tilt to be provided to Solar panel for optimum charging.
Remote Operation for Maintenance: 1. Connectivity via Bluetooth App Version 1.0.5 Android 8.0 Oreo (API26) up to 30 meters detection in open space with antenna placed internally not visible outside 2. Dedicated mobile App with settings to be provided for Bluetooth operation 3. User accessible dual dimming feature-Dimming percentage, Timer based dimming 4. Different level of dimming possible-Preconfigured factory settings as well as customisation as per site requirements 5. User can track status of system, battery status, voltage detection, dimming type & dimming percentage 6. Easy maintenance and service via Bluetooth app.
Warranty: Warranty and maintenance assurance certificate for atleast 5 (Five) years. Make: (BAJAJ/TRANSRAIL/CROMPTON/Signify as approved by EIC)
Supply & Delivery of 4 CORE, 10 SQMM, XLPE ELECTRIC POWER CABLE:Voltage grade: 1.1 KV No of Core: 4 Nominal Area of Cross section: 10 Sq.mm , Conductor: Aluminum stranded conductor complying with IS: 8130 - 1984 with latest amendment if any, Core Insulation: XLPE insulated,Core identification: Colour coded , Inner Sheath: Wrapped /extruded with thermoplastics materials.Armouring: Galvanized single steel strip armouring Outer Sheath: Polyvinyl Chloride (PVC), BIS Specification: Conforming to IS: 7098 Part - 1 with latest amendment if any and marked with ISI.Drum length : 500 Meter ± 5 %. (Make-KEI/Polycab/Gloster as approved by EIC)
4 CORE, 35 SQMM, XLPE ELECTRIC POWER CABLE: Voltage grade: 1.1 KV No of Core: 4,Nominal Area of Cross section: 35 Sq.mm ,Conductor: Aluminum stranded conductor complying with IS: 8130 - 1984 with latest amendment if any, Core Insulation: XLPE insulated,Core identification: Colour coded , Inner Sheath: Wrapped / Extruded with thermoplastic materials Armouring: Galvanized Single steel strip armouring Outer Sheath: Polyvinyl Chloride (PVC), BIS Specification: Conforming to IS: 7098 Part - 1 with latest amendment if any and ISI Marked. (Make-KEI/Polycab/Gloster as approved by EIC)
Supply of feeder piller box (floor mounted type) of size 1372 x 914 x 607 mm made by 3.15 mm thickness MS Plate and 50x50x6 MS Angle frame) with 900 mm Legs made up of 40x40x5 MS Angle with two door locking system for street light control incl following switchgears(Make: L&T/Havells or as appd by EIC), and painting as per direction of EIC (Drawing alongwith make of each component to be approved by EIC 200 A Cu Busbar -4 Nos. (min-1 mtr lenghth each) Danger Board-2 Nos. 20 cm x 30 cm (8" x 12")
Incoming:- 100A TPN MCCB - 1 No. Supply & delivery of the following Current Transformer (Make: KAPPA/AE): Ratio:- 100/5A - 3 Nos.
Outgoing:- Street Light Control: 40A TPN MCB - 1 No. Digital Time Switch - 1 No. Supply and fixing of 415volt, 50 Hz, 4P, power contactor (Make: L&T/ABB/Schneider/ Simence/ GE) having contact block of the following range: 9-25Amp, 1NO/1NC - 1 No. 6-32A SP MCB, 10 kA - 12 Nos. For Signage & security room 16 A DP MCB - 1 No.
Supplying and erecting submersible pump set suitable for erection on open well of 7.5 KW/10 HP with 415 V 50 c/s.A.C. supply, having delivery head from 65-50-42 m and capacity from 160 to 410 Itrs. per minute & pipe of Delivery 50 mm diameter erected with necessary H type clamps as per direction of EIC (make: Kirloskar/KSB Cat No. -BPD 242/06A + UMAI (S) 150-6/22 or equivalent as appd by EIC)
Supplying and erecting submersible monoblock pump set suitable for erection on open well of 7.5 KW/10 HP with 415 V 50 c/s.A.C. supply, having delivery head from 65-50-42 m and capacity from 160 to 410 Itrs. per minute & pipe of Delivery 50 mm diameter erected with necessary H type clamps as per direction of EIC (make: Kirloskar Cat No. MR 10F C-80-65-38 SD/KSB or equivalent as appd by EIC)
Supply & fixing of 10 HP Pump Starter panel suitable for Pump Motor set including Vstart & stop switchs and single phase preventer & thermal over load complete wiring & connection and allied accessories as required. (Make: L & T Cat No. MUG-15 FASD)
Supply & fixing of 1100V grade 3 core 2.5 sq.mm PVC insulated and PVC sheathed cable with electrolytic grade annealed copper conductor flat cable for submersible monoblock pump motor from starter panel to pump motor set at UGR as directed by EIC in underground trench as under GS. (Make: MESCAB/Finolex/Havells/KEI as approved by EIC)
S/F/F UPVC column pipes of Ashirvad make 80mm dia heavy duty quality.
S/F UPVC upper & lower adapter for 80mm dia pipe (Ashirvad)
S&F wall bracket fan (400 mm) Swing Platina of Havells/Orient make fixed on wall by nut bolts to G.S for security room
Supply of industrial box type luminaries suitable for Single LED Batten tube light fittings (make: Signify Cat No. BN170C LED 40S-6500 PSU L1 20/Havells or as approved by EIC)
S/F Bulk Head light fittings directly on wall Crompton 10 watt outdoor fittings with IP-65 protection as per direction of EIC. Cat No. CIS-306-10-57-SL-DP-NBK or equivalent as approved by EIC
Supply & drawing of 1.1KV Al. XLPE Armoured cable as directed by EIC. (Make:- KEI/ Polycab/ Gloster as approved by EIC ) 4C X 16 sq.mm through HDPE pipe
Supply & drawing of 1.1KV Al. XLPE Armoured cable as directed by EIC. (Make:- KEI/ Polycab/ Gloster as approved by EIC ) 2C X 10 sq.mm through HDPE pipe
Supply, Fabrication, Fixing and fitting of angle iron frame fabricated from 75mmX50mmx6mm MS C Channel with cross 40x40x6 mm MS angle & redial support including six numbers 6inches X 6inches x10 mm MS base plate for fixing on the structure with all necessary welding & fabrication. the structure shall be proper welding as per instruction of E.I.C including painting as directed by E.I.C
Supply & Fixing of angle iron frame fabricated from 50mmX50mmsquare four no. hollow bar with cross angle & redial support including.one number 40X40mm x6 mm angle iron support in the middle for the sign board for size 16 ft with suitable three nos cross angle support welded with six nos angle hook in equal space for fixing on the structure with all necessary welding & fabrication. the structure shall rest in both side with 40mmX40mm approximate length up to 4ft behind the ACP board structure for back support poper welding as per instruction of E.I.C including painting as directed by E.I.C 2 Nos board
Supply and fixing ACP back lit LED sign board made 3 mm thick ACP sheet(Alstrong/aludacore) finished with approved metallic colour as back ground(Deep Blue; Colour Code to be approved by EIC) after router cutting. The riser structure also shall be covered with ACP sheet.(Front side & back side ACP sheet) (including 4 side are moulded by ACP) LED board. =2 nos board
Supply & Fixing special type of imported 62.5 mm thick acylic sheet having dimention of 375 mm dia Biswa Bangla & National Emblem on ACP board. =2 Nos board (Make-Astariglas/UB or equivalent as approved by EIC)
Supply & Fixing special type of imported 62.5 mm thick acylic sheet having dimention of 375 mm dia WBSIDCL industrial logo on ACP board. = 2Nos board (Make-Astariglas/UB or equivalent as approved by EIC)
Supply and fixing special type of imported acrylic letter (3 mm thick) projected on the ACP board 62.5 mm. The letter font shall be in horizontal line. 2 Nos. board (Make-Astariglas/UB or equivalent as approved by EIC)
Supply and fixing special type of imported acrylic letter (4 mm thick) projected on the ACP board 62.5 mm. The letter font shall be in horizontal line with vynile cutting pasting letter, having dimention (For official website and email.= 3 Nos board, (Make-Astariglas/UB or equivalent as approved by EIC)
S&F 230V,1.50 Watt LED module inside the acylic sheet letter. One run for each letter including wiring ( Make- Arihant Samsung / Aries / GOQ powered by Samsung/Osram as approved by EIC) for 2 nos. board
S & F water proof 300 watt power supply system IP65, 50/60Hz frequency, 180 to 260V , AC power supply,.095 power factor for LED lamp. (Make: union / aries as approved by EIC).
Supply and fixing 50 mm x 25 mm alumminium channel having length 3 Nos board
Transportation cost for taking away the LED sign board from Company's workshop to work site incl loading/unloading.
Timer Panel consisting of: i) Enclosure: 450 mm x300 mm x 200 mm (Sheet Thickness 2 mm) ii) Time Switch: AUTS01ANA00 (L&T)-1 iii) 32A TPN MCB: (L&T)-1 iv) 32 A Contactor-MNX 32(L&T)-1 v) 6A SPN MCB-(L&T)-1 vi) Toggle Switch-1 vii) Indicating Lamp viii) Interconnecting Cu Wire (Make: KEI/Polycab/Glaster as approved by EIC)
Supply & Laying of 2cx10 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting (Make-KEI/Polycab/Gloster as approved by EIC)
Erection of MS C Channel in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented as per direction EIC
Supply & Fixing Sintex make SMC Junction box for ( Size: 155x100x60 mm) Cat No. GSJB 1510
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.34 MB
Tendernotice_2.pdf
PDF • 1.01 MB
Tendernotice_3.pdf
PDF • 0.36 MB
BOQ_2389291.xls
BOQ • 0.90 MB
Download all tender documents and submit your bid