Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹42.7 LAccepted-AOC | L-1 | Accepted-AOC LOWEST-1 | |
| 2 | L-2₹48.5 L−₹3.8 Cr (88.8%)Rejected-Finance KALIJHORA KALIJHORA BAZAR KALIJHORA BAZAR KALIJHORA BAZAR DARJEELING WEST BENGAL 734008 | DARJEELING | WEST BENGAL | 734008 | L-2 | Rejected-Finance Lowest-2 | |
| 3 | l-3₹54.4 L−₹3.8 Cr (87.4%)Rejected-Finance | l-3 | Rejected-Finance Lowest-3 |
Tender Value
₹39.5 L
EMD Value
₹66,801
Closing Date
16 Aug 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE
EXECUTIVE ENGINEER JAL SHAKTI DIVISION BAGGI
AS PER BOQ
2022_HPIPH_63423_1
EE-JSD-BAGGI/2022- 19610-60 DATED 04/082022
Open Tender
Civil Works
Item Rate
180 days
BAGGI
AS PER NIT
6 documents required · 6 mandatory
₹400
EE BAGGI
₹66,801
Yes
18 Jan 2024
6 Aug 2022
17 Aug 2022
6 Aug 2022
16 Aug 2022
6 Aug 2022
120 days
Amount
Excavation in foundation,trenches (for pipes & pits) up to all depths in all classification of earth work such as pick work,jumper work,saturated soil including bailing and pumping out water, blasting soft/hard rock or chiseling soft/hard rock where blasting is prohibited in all lifts including trimming & dressing of sides, levelling of beds to correct grade i/c shoring/ strutting,planking, timbering & dewatering wherever required, stacking the useable of unuseable material/ soil separately & after laying jointing testing of pipes in trenches in 15 Cm layers including consolidating of each deposited layer by ramming & watering & then disposing of all surplus Excavated soil/unusable material as directed with in all leads & lifts including restoration of unmetalled surfaces to its original condition & including cost of diversion for traffic,night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per the entire satisfaction & directions of Engineer- in- charge.
Providing, laying, Jointing, testing and carriage in trenches to be levelled to grades IS marked , MSERW flanged pipe of following dia meters conforming to ISO 3183-2007 (latest with up to date ammedments) having minimum wall thickness as specified below of steel grade L 290 or X42 jointed with flanges conforming to table as specified below of IS 6392-1971 (latest with upto date ammendments ) welded at both ends according to relevant IS standard and detailed specifications and provided with nuts and bolts of required size, 3mm thick compressed asbestos fiber gasket or synthetic rubber gasket conforming to relevant IS codes including all short pieces,bends tees,and other specials extra made from parent tubes and welded with flanges of tables as applicable to the particular reach and of approved specifications as per site condition including flushing,cleaning,painting and hydraulic testing complete. The pipes and specials shall have galvanised coating as per ISW-4736 with latest ammendments at following RDs.
65mm dia, ISO 3183-2007, Flange Table -34, Wall Thickness= 4.00mm L -290
Providing Laying, jointing, testing and carriage (by way of circumfrential butt welded joints by electrical arc welding) and testing of MS ISO 3183-2007 of following dia meters conforming to ISO 3183-2007 OR latest with upto date amendments, with bevelled ends and capable of withstanding required test pressure in a random length, including manufacturing specials, reducers/ tapers , all short pieces, bends, equal and unequal TEE's etc. as per site requirement made from parent tubes . The laying of pipe will also include all operations such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering & laying in excavated trenches to ensure required level i/c flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and specials ( if damaged during laying jointing operation of pipe) made form the parent tube , shall be provided with anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing , complete in all respect in all leads and lifts to the best satisfaction & direction of Engineer in charge . ( Earth work if required in trenches, to be measured and paid for seperately)
65mm dia, ISO 3183-2007, Wall Thickness= 4.00mm L-290
Laying, jointing, testing and carriage in trenches to be leveled to grades, IS marked GI flanged pipes of following diameters conforming to IS 1239-1990 (part-II) (latest with up to date ammendments) having minimum wall thickness as for class of pipe specified below jointed with flanges conforming to tables as specified below of BIS 6392-1971 (latest with up to date amendments) welded at both ends according to relevant BIS standards and detailed specifications as appended in NIT & provided with nuts & bolts of required sizes, 3mm thick compressed asbestos fibre gasket of synthetic rubber gasket conforming to relevant BIS codes as given in technical specifications including all leads and lifts, flanged short pieces, bends, tees and other specials etc. made from parent tubes including bends & welded with flanges of tables as aplicable for the particular reach & of technical specifications appended in the NIT as per site conditions including flushing cleaning & hydraulic testing as per directions of the Engineer-in-charge.
GI pipe 65mm dia, Heavy Class , Flange Table -34, Wall Thickness= 4.50mm
GI pipe 65mm dia, Medium Class , Flange Table -34, Wall Thickness= 3.60mm
Laying, jointing, testing and carriage of GI pipe (MC) (by way of circumfrential butt welded joints by electrical arc welding) of following dia meters conforming to IS 1239-1991 OR latest with upto date ammendments, with bevelled ends and capable of withstanding required test pressure in a random length, including manufacturing specials, reducers/ tapers , all short pieces, bends, equal and unequal TEE's etc. as per site requirement made from parent tubes . The laying of pipe will also include all operations such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering & laying in excavated trenches to ensure required level i/c flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and specials ( if damaged during laying jointing operation of pipe) made form the parent tube , shall be provided with anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing , complete in all respect in all leads and lifts to the best satisfaction & direction of Engineer in charge . ( Earth work if required in trenches, to be measured and paid for seperately)
GI pipe 65mm Dia, Heavy Class ,Wall Thickness= 4.50mm
GI pipe 65mm Dia, Medium Class , Wall Thickness= 3.60mm
CENTRIFUGAL STAGE :- Providing and supplying of horizontal spindle/vertical split casing single/ (backpull out arrangement) Multistage centrifugal / Reciprotcating pumps of approved make such as KSB/ Mather & Platt/ Kirloskar /Best & Crompton/ BE pump as per BIS 5120-1980 (latest with upto date ammendment) read with BIS 9137 -1978 OR latest to handle clear water having turbudity upto 50 ppm edition sutiable for lifting water for under maintioned characterstics with bronze impeller/priming funel,casing ring and shaft sleeves or bronze, shaft of steel with cast iron casing couple directly through a flexible coupling on a common CI / Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to sliping/squirrel cage screen proctected drip proof induction motor/motors of approved make such as Kirloskar /NGEF/ GEC/ Crompton / Siemen/ Jyoti /ABB/Marathon. operation range of plus (+)10% and minus(-) 15% of duty point head. The motor/motors as per IS 325-1978 with upto date ammendment read with IS 900 -1972. It should include cost of bearing , nuts ,volts and painting etc and should meet the following requirments
SITE CONDITIONS :-Location of site:- About 6Km from Dadour. The altitude of place in which the motor is intended to work in ordinary service if it exceeds 763 mtr. Altitude of place is 763 mtrs above MSL Humidity : Weather generally remains humid during monsoon season Nature of atmosphere : As normally encountered in Shivalik Range. Detail of quality of water Clear cold water. Water free from sand or not Yes Water corrosive or not No Turbidity (if any) Clear Cold water NPSH avilable N.A. . Any other information or requirement Rising main Dia:- 65mm and total length is 4500 mtr. B.OPERATING CONDITIONS Type of current AC three/single phase Operating frequency 50 HZ Rated voltage 415 (+/-) 10% volts System of earthing if any to be adopted.Double loop earthing as per BIS 3043-1987 latest with upto date ammendments No. of working hours per day 8 hours Speed of revolution in RPM To be quoted by tenderer Direction of rotation To be quoted by tenderer. The max. Temp. of cooling air & water in the place in which the pumpset is intended to work in ordinary service. 35 degree centigrade. C. MOTOR Ref to BIS code BIS 325-1978 read with BIS 900-1992 (latest) with up to date amanedments. Type of enclosure of motor SPDP (As per BIS 4691-1985, latest). Type of duty Continuous
Mechanical out put in KW Suitable for driving submersible pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. Class of insulation Class -B/F- Max.permissible temp.rise of motor reqd. if different from that given in B (viii) above To be specified by the tenderer Particulars of test required & where they are to be conducted. As per terms & conditions attached Particulars as to whether voltage limiting device will be employed ATS / Star Delta starter oil immersed,fully automatic to be installed between bus bar chamber & motor.Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE:- Star delta starter upto 37.5 KW & ATS for 37.5 KW to 50 KW & stator rotor starter with slip ring motor beyond 50 KW. Motor whether squirrel cage or slipring Squirrel cage. Note: Squirrel cage up to 65 HP & slipring above 65 HP Details of shaft extension required. Just sufficient to provide direct drive by flexible coupling to pump. Type of slipring gear whether continously rated or for starting purposes only and whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required.Continously rated for squirrel cage/ slippering motor. Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit. Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current. Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period. To work the pump offered Where possible fault capacity of the system to which the motor is connected. The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
PUMPS: BIS: 1520-1980, read with BIS 9137-1978 both latest with up to date amendments. Nos of pumpsrequired 2 No. pumps( One will be act as standby) Spare parts required for six months normal maintenance as recommended by manufacturer. Optional fittings reqd.Air cock for exhausting air from each stage E. PUMP OPERATING CONDITIONS Capacity 2.42 LPS. Total head in Mts.481.46 Mtrs.( If total head is not known then following details be provided) :- Static head 393.00 mtrs. Minimum depth of water ………….. Mtrs. Variation in water level ………….. Mtrs. Ground level to max. water level '------------------- Mtrs. Ground level to delivery point ---------------Mtrs. Pressure in the suction tank …………. Kg/cm^2 Pressure in the delivery tank …………. Kg/cm^2 Length of R/Main -4500 mtrs ( column pipe +Rising main) Dia of R/Main 65mm Dia (MC) Drive arrangement: Direct through flexible coupling on a common base plate.Drive type Electric driven NPSH required To be quoted by tenderer /contractor. Limits of total head in which the pump is reqd. to operate. (-) 15% to (+) 10% of total head. Suction/delivery size of pump To be specified by the tenderer Efficiency of pump at To be specified by the tenderer (a) Duty head ( b) (+) 10 % head ( c) (-) 15 % head Material of construction To be specified by the tenderer (Manufacturer's certficate to be appended)
Suply of suitable oil immeresd Star Delta Starter/ATS/stator Rotor Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release with initial oil filling. Note:- Star- delta - starter upto 37.5 KW. ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50KW.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Bushbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52 Kg/cm^² NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirlosker/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pas arrangement & size equal to delivery of Pump for withstanding nominal seat pressure of 52Kg/cm^² NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Glad/Bhel/Leader of suitable size Cast Iron/Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 52 Kg/cm^² NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Glad/BHEL/Leader/of reputed make of suitable size cast iron flanged sluice valve confirming to IS 780, size equal to dia of suction pipe PN 1 Provided with hand wheel/Cast iron Cap.
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with upto date ammendments.
Providing Laying suitable size copper pVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phase) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor. The type size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing laying suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part-I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipes, solder, nuts & bolts, cable gland sets. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing laying double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure indicated in item No. 1e(ii). Note :- Actual laying to be done as per final drawings to be approved by the Engineer-in-Charge.
Errection of all equipments from S.No. 6 to 19 i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Royal Construction Company
Bharat Engg and Suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .