Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-Finance | ₹24.9 L | L1 | Accepted-Finance Only Bidder |
| 2 | Not Admitted-Fee B 71 ASHISH ROW HOUSE 395009 RANDER SURAT GUJARAT 395009 UDYAM GJ 22 0018204 24AEKPG4203R1ZD R S MSME STATUS AS NOT VERIFIED | SURAT | GUJARAT | 395009 | - | - | Not Admitted-Fee Fee not received |
| Sl No | Description | Qty | Unit | FINIX ENGINEERING & Services L1 |
|---|---|---|---|---|
| 1.00Air Conditioning System | ||||
| 1.01 | Design, Supply, Installation, Testing and Commissioning of air-cooled type ceiling suspended ductable Split air conditioners of following nominal cooling capacity with HFC-134a / 407C / 410A, comprising hermetic scroll compressors , air cooled condenser unit, indoor evaporator with cooling coil of minimum 3 rows of copper coil with aluminium fins, blower and motor, the blower shall be capable of developing static pressure required for overcoming the pressure drop in supply air plenum. The Indoor unit shall have DIDW forward curved centrifugal blower driven by suitable single / three Phase motor, thermostat, starter for motors of compressors, condenser and blower with overload relay and single phase preventer, HDPE filters, return air slots and associated refrigerant piping all housed in a sheet metal cabinet and duly painted. Entire indoor unit shall be acoustically insulated as per standard. The noise level of indoor unit shall not exceed 60 db within 1 meter of the units. Refrigerant piping of heavy gauge hard drawn copper with suitable Nitrile rubber thermal insulation for connecting condensing unit and indoor unit kept at an average distance of 8 M. Refrigerant piping and cables shall run in cable tray/ PVC conduits to protect them from mechanical damage. Condensing units shall be connected to the indoor evaporator unit and the refrigerant piping should include necessary service valves for isolation of refrigerant lines. The ductable Split unit shall be provided with microprocessor based control system with corded remote and fully automatic in operation. Auto restart after resumption of power supply in case of power failures shall be an inbuilt feature of Split A/C unit. Display of parameters like room temperature, status of split unit, fault / trip indication shall be provided with split A/C unit. 4 TR Ductable inverter AC unit. Make - Mitsubishi/Daikin | 2 | each | 2,34,500 ₹4.7 L |
| 1.02 | Supply, Installation, Testing and Commissioning of 4 way inverter cassette AC units with all the accessories. Each of nominal capacity as indicated below suitable for operation on Single Phase, 230V/ 415V± 10%, 50 Hz AC supply for both indoor and outdoor unit, outdoor unit mounting stand, R-32/R-410A/ R407c refrigerant with accessories. 1.5 TR Inverter Type Cassette AC. Make - Mitsubishi / Daikin | 1 | set | 1,16,700 ₹1.2 L |
| 1.03 | Supply, Installation, Testing and Commissioning of 4 way inverter cassette AC units with all the accessories. Each of nominal capacity as indicated below suitable for operation on Single Phase, 230V/ 415V± 10%, 50 Hz AC supply for both indoor and outdoor unit R-32/R-410A/ R407c refrigerant with accessories. 4 TR Inverter Type Cassette AC. Make - Mitsubishi/ Daikin | 5 | set | 2,32,000 ₹11.6 L |
| 1.04 | Supply, Installation, Testing and Commissioning of refrigerant piping between indoor and outdoor units with heavy gauge hard drawn copper refrigerant piping (including Suction & Liquid lines) of suitable size along with 13mm thick elastomeric Nitrile rubber insulation, heat sealant tape, necessary clamps, support etc. The entire work shall be executed as instructed by Engineer in charge. | 10 | metre | 2,800 ₹28,000 |
| 1.05 | Supply and laying of adequate size additional refrigerant copper piping kit suitable for AC units consisting copper tubing (Suction and delevery) of suitable size, elastomeric nitrile rubber insulation for suction and liquid line and covering all the pipes and cable with wheather proof insulation covering tape and clamping at an interval of 600mm complete as required and as directed by EIC. | 100 | metre | 1,800 ₹1.8 L |
| 1.06 | Supply and installation of drain piping made of rigid PVC pipe size of 32mm dia with Elastomeric Nitrile rubber insulation, heat sealant tape etc., for the above ductable Split AC units. All the joints shall be neatly sealed with jointing materials. All the loose ends shall be properly plugged/capped etc. The PVC pipe is for drain water line and is to be connected to drain point of DSAC indoor unit. The entire work shall be executed as instructed by Engineer in charge " | 120 | metre | 350 ₹42,000 |
| 1.07 | Supply, fabrication and erection of GSS ducting grade 120 GSM confirming to latest IS:655 & 277 complete with dampers supporting arrangements ie. tab hangers, anchor fasteners, vanes, access door frame work etc. for plenum, ducts, wall opening & closing the openings after erecting of duct etc complete as required and as indicated below. 0.63 mm GSS Duct. Make: Sail / Tisco / Jindal / I spot | 50 | sqm | 1,600 ₹80,000 |
| 1.08 | Supply, fabrication and erection of GSS ducting grade 120 GSM confirming to latest IS:655 & 277 complete with dampers supporting arrangements ie. tab hangers, anchor fasteners, vanes, access door frame work etc. for plenum, ducts, wall opening & closing the openings after erecting of duct etc complete as required and as indicated below. 0.80 mm GSS Duct . Make: Sail / Tisco / Jindal / I spot | 15 | sqm | 1,800 ₹27,000 |
| 1.09 | Supply and installation of fresh air intake louvers of size 300 x 300 mm, made out of extruded aluminium with bird/insect screen provided with intake louvers and all aluminium made volume control dampers, complete as directed by Engineer-In- Charge. | 1 | no | 4,000 ₹4,000 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
23 Dec 2025, 3:00 pmClosed
Deputy Vice President (Projects)
Projects Division, HLL Lifecare Ltd, HLL Bhavan Poojappura
HVAC works
2025_HLL_253525_2
HLL/CHO/PROJ/INT/GJB-5/HVAC
Open Tender
Miscellaneous Works
56 days
Thiruvananthapuram
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,950
HLL Lifecare Ltd
₹50,000
5 Jan 2026
1 Dec 2025
24 Dec 2025
1 Dec 2025
23 Dec 2025
1 Dec 2025
Amount
Air Conditioning System
Design, Supply, Installation, Testing and Commissioning of air-cooled type ceiling suspended ductable Split air conditioners of following nominal cooling capacity with HFC-134a / 407C / 410A, comprising hermetic scroll compressors , air cooled condenser unit, indoor evaporator with cooling coil of minimum 3 rows of copper coil with aluminium fins, blower and motor, the blower shall be capable of developing static pressure required for overcoming the pressure drop in supply air plenum. The Indoor unit shall have DIDW forward curved centrifugal blower driven by suitable single / three Phase motor, thermostat, starter for motors of compressors, condenser and blower with overload relay and single phase preventer, HDPE filters, return air slots and associated refrigerant piping all housed in a sheet metal cabinet and duly painted. Entire indoor unit shall be acoustically insulated as per standard. The noise level of indoor unit shall not exceed 60 db within 1 meter of the units. Refrigerant piping of heavy gauge hard drawn copper with suitable Nitrile rubber thermal insulation for connecting condensing unit and indoor unit kept at an average distance of 8 M. Refrigerant piping and cables shall run in cable tray/ PVC conduits to protect them from mechanical damage. Condensing units shall be connected to the indoor evaporator unit and the refrigerant piping should include necessary service valves for isolation of refrigerant lines. The ductable Split unit shall be provided with microprocessor based control system with corded remote and fully automatic in operation. Auto restart after resumption of power supply in case of power failures shall be an inbuilt feature of Split A/C unit. Display of parameters like room temperature, status of split unit, fault / trip indication shall be provided with split A/C unit. 4 TR Ductable inverter AC unit. Make - Mitsubishi/Daikin
Supply, Installation, Testing and Commissioning of 4 way inverter cassette AC units with all the accessories. Each of nominal capacity as indicated below suitable for operation on Single Phase, 230V/ 415V± 10%, 50 Hz AC supply for both indoor and outdoor unit, outdoor unit mounting stand, R-32/R-410A/ R407c refrigerant with accessories. 1.5 TR Inverter Type Cassette AC. Make - Mitsubishi / Daikin
Supply, Installation, Testing and Commissioning of 4 way inverter cassette AC units with all the accessories. Each of nominal capacity as indicated below suitable for operation on Single Phase, 230V/ 415V± 10%, 50 Hz AC supply for both indoor and outdoor unit R-32/R-410A/ R407c refrigerant with accessories. 4 TR Inverter Type Cassette AC. Make - Mitsubishi/ Daikin
Supply, Installation, Testing and Commissioning of refrigerant piping between indoor and outdoor units with heavy gauge hard drawn copper refrigerant piping (including Suction & Liquid lines) of suitable size along with 13mm thick elastomeric Nitrile rubber insulation, heat sealant tape, necessary clamps, support etc. The entire work shall be executed as instructed by Engineer in charge.
Supply and laying of adequate size additional refrigerant copper piping kit suitable for AC units consisting copper tubing (Suction and delevery) of suitable size, elastomeric nitrile rubber insulation for suction and liquid line and covering all the pipes and cable with wheather proof insulation covering tape and clamping at an interval of 600mm complete as required and as directed by EIC.
Supply and installation of drain piping made of rigid PVC pipe size of 32mm dia with Elastomeric Nitrile rubber insulation, heat sealant tape etc., for the above ductable Split AC units. All the joints shall be neatly sealed with jointing materials. All the loose ends shall be properly plugged/capped etc. The PVC pipe is for drain water line and is to be connected to drain point of DSAC indoor unit. The entire work shall be executed as instructed by Engineer in charge "
Supply, fabrication and erection of GSS ducting grade 120 GSM confirming to latest IS:655 & 277 complete with dampers supporting arrangements ie. tab hangers, anchor fasteners, vanes, access door frame work etc. for plenum, ducts, wall opening & closing the openings after erecting of duct etc complete as required and as indicated below. 0.63 mm GSS Duct. Make: Sail / Tisco / Jindal / I spot
Supply, fabrication and erection of GSS ducting grade 120 GSM confirming to latest IS:655 & 277 complete with dampers supporting arrangements ie. tab hangers, anchor fasteners, vanes, access door frame work etc. for plenum, ducts, wall opening & closing the openings after erecting of duct etc complete as required and as indicated below. 0.80 mm GSS Duct . Make: Sail / Tisco / Jindal / I spot
Supply and installation of fresh air intake louvers of size 300 x 300 mm, made out of extruded aluminium with bird/insect screen provided with intake louvers and all aluminium made volume control dampers, complete as directed by Engineer-In- Charge.
Factory fabricated aluminum grilles for SA & RA with / with out volume control damper, necessary frame work etc. and complete as required including powder coated finish of approved colour. SA Grills With VCD
Factory fabricated aluminum grills for SA & RA with / with out volume control damper, necessary frame work etc. and complete as required including powder coated finish of approved colour. A Grills With VCD
Duct Acoustic insulation of plenum/supply air ducting with 10 mm thick processed elastomeric open cell class 'One' type Nitrile rubber insulation material having a density of 140 - 180 Kg / cu. mtr. It shall be flame and fire retardant and shall have low thermal conductivity. The insulation shall be fixed with suitable fire retardant adhesive and it shall be fixed using nut & bolt with Aluminium washers at an intervals of maximum 600mm and as per duct size. The whole work shall be carried out as per the instruction of the Engineer-in-charge. Make : Aeroflex / Superlon / Supreme/K flex
Supply & fixing of thermal insulation for SA ductswith 9mm thick closed cell Nitrile rubber Elastomeric insulation of density 40-55 kg/m3 at 20 deg.C, moisture diffusion resistance factor 10000 and shall have antifungal and anti microbial properties. It shall be flame and fire retardant and shall have low thermal conductivity. Nitrile rubber shall have fire performance of class O as per BS 476 Part6 and Part 7. All longitudinal and transverse joints shall be suitably sealed with Alu. foil tape. The insulation shall be stuck with adhesive of Pidilite Eco fresh or equivalent make. The adhesive shall be of low VOC, suitable for use on nitrile rubber and non flammable.The insulation shall have Alu. foil backing for the outer surface. Make : Aeroflex / Superlon / Supreme/K flex
Supply and fixing of Isowall panel boxing for ductable AC units as per site requirement . Isowall panels shall be of 50mm thick (min)expanded polystyrene, both side of panel shall be laminated with0.50mm thick galvanized steel sheet coated with polyester paintwith strippable polythene sheet. the work shall be executed atsite as per site condition making use of pre fabricated/factoryL angle/C channels etc. All the joints shall be sealed with siliconsealant. The cost includes all materials, labor, fixing arrangements as per site conditions.
Manufacturing, Supply and Installation of Isowall Panel Door as approved by Engineer in Charge
Supply and installation of outdoor stand for air conditioning units, fabricated from heavy-duty galvanized iron or structural grade steel suitable for wall-mounting or floor-mounting as per site requirement including accessories.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 225 mm width X 50 mm depth X 1.6 mm thickness
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm (Make : Finolex, Polycab,KEI)
Dismantling and Refixing
Dismantling of existing 3TR cassette-type air conditioning unit, including indoor and outdoor units, refrigerant piping, electrical connections, and drainage line, ensuring minimal damage to the site and equipment for potential reuse and stacking as per the direction of Engineer in Charge.
Dismantling of the 1.5TR split air conditioning system comprising the indoor unit, outdoor unit, refrigerant piping, drain line, and electrical connections, ensuring no damage to reusable components and stacking as per the direction of Engineer in Charge.
Refixing/reinstallation of a 3TR cassette-type air conditioning unit, including both indoor and outdoor units, refrigerant piping, vacuuming and gas charging electrical connections, drain line, testing, commissioning, and making the system fully operational.
Reinstallation of a 1.5 Ton split air conditioner system including indoor and outdoor units, interconnecting copper piping, drain pipe, power cable, vacuuming, refrigerant charging, testing, and commissioning. The unit shall be made fully functional after reinstallation.
Reinstallation of a 1.5 Ton split air conditioner system including indoor and outdoor units, interconnecting copper piping, drain pipe, power cable, vacuuming, refrigerant charging, testing, and commissioning. The unit shall be made fully functional after reinstallation.
Description of Work / Item(s)
Amount
Lift - CAMC
Design, Supply, Installation, Testing And Commissioning of HVAC System on 5th Floor at Golden Jubilee Block, Poojappura, Thiruvananthapuram - CAMC Rate in Rupees/Year
1st year (Free of Cost)
2nd year (Free of Cost)
3rd year (Free of Cost)
4th year
5th year
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
IFB_HVAC.pdf
Tender Documents • 1.20 MB
BOQ_296947.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid