Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC A 3 13 SIMANDHAR ENCLAVE NEAR PAVAPURI BUS STOP GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | ₹8.9 L Quoted ₹9.9 L | L1 | Accepted-AOC Accept |
| 2 | L2₹10.0 L+₹11,270 (1.13%)Rejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | ₹10.0 L+₹11,270 (1.13%) | L2 | Rejected-Finance Rejected due to bidder not L1 |
| 3 | L3₹10.1 L+₹21,823 (2.20%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹10.1 L+₹21,823 (2.20%) | L3 | Rejected-Finance Rejected due to bidder not L1 |
| 4 | L4₹12.0 L+₹2.1 L (20.8%)Rejected-Finance | ₹12.0 L+₹2.1 L (20.8%) | L4 | Rejected-Finance Rejected due to bidder not L1 |
| 5 | L5₹12.7 L+₹2.8 L (28.0%)Rejected-Finance 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | ₹12.7 L+₹2.8 L (28.0%) | L5 | Rejected-Finance Rejected due to bidder not L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
28 Jun 2023, 6:00 pmClosed
Maj Ravinder Sharma and Smt Saroj A Makwana AE QS
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION WORKS IN MD AND OTM ACCN OF ZONE B AT AHMEDABAD
2023_MES_602013_1
8331/E8
Open Tender
Civil Works
Works
180 days
GE (Army) Ahmedabad
As per NIT
8 documents required · 8 mandatory
₹500
GE (Army) Ahmedabad
₹30,000
Yes
12 Mar 2024
8 Jun 2023
30 Jun 2023
8 Jun 2023
28 Jun 2023
13 Jun 2023
8 Jun 2023 - 13 Jun 2023
Amount
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked fixing accessories and sunken galvanized modular steel terminal boxes of thickness not less than 1.2 mm covered with suitable galvanized steel box, plate with cover for mounting of switches, sockets, fan regulators complete including making good the wall surfaces with matching colour on wall complete. - Note : Including Cutting chases,pinning in ,making good for facings where required and pointing the cement mortar 1:3 to ends or edges of landings,steps,cills,sun shades,shelves,lintels etc and cutting chases for concealed conduit wiring etc and making good ,cutting not exceeding 10cm grith all as specified and directed.
One light point controlled by one switch.
One fan point /Exhaust fan point controlled by one switch.
One light point controlled by two, two way switches.
One socket outlet 6 amp controlled by one switch on the same board with other switches.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 4 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 4 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with with suitable galvanized steel box, plate with cover complete for one 16 amp socket outlet controlled by one switch on independent board including making good the wall surfaces with matching colour on wall complete.
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x12 mm ISI marked ivory colour with all fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete.
One light point controlled by one switch.
One fan point /Exhaust fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board with other switches.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
One light point controlled by two, two way switches.
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 4 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 4 sqmm (Green) drawn into and including PVC casing-caping not less than 32 x12 mm ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover complete for one 16 amp socket outlet controlled by one switch on independent board Cable complete
S&F angle holder, insulated polycabonate body with back plate complete.
S&F switch piano flush button single pole one way 6 amp complete.
S&F switch piano flush button single pole one way 16 amp complete.
S&F switch flush type, 6 amp, single pole, two way complete.
S&F bell push, flush type, 6 amp 240 volts complete.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F ceiling rose 3 plates polycarbonate body complete.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete.
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FR-LSH multistranded copper conductor cable (Phase - R,Y,B, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories complete
2x4 sqmm + 1x4 sqmm earth wire in 20 mm dia conduit.
2x6 sqmm + 1x6 sqmm earth wire in 25 mm dia conduit.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FR-SH multistranded copper conductor cable (Phase - R,Y,B, Neutral - Black, Earth - Green) drawing into into including PVC casing-caping not less than 25x12 mm ISI marked of following nominal sizes
2x4 sqmm + 1x4 sqmm earth wire.
2x6 sqmm + 1x6 sqmm earth wire.
Supply and Fix LED Batten 20 watt tube light fiiting complete with decorative type fitting 4 feet long with Light Linear with its bright light output at 100 lumen/watt give batten type complete including all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core 6500K ( fittings shall be fitted on two plastic square/round block. Note power factor should not be less than 0.90.Sqmm, PF>0.9 all as required at site complete
Supply and Fix in replacement existing unsv sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long of same make having ballast, bipin holder, connector block etc complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core,6500K , PF>0.9 all as required at site complete
S&F energy efficient recessed mounted LED luminaire 36 Watt suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required complete
Supply and fixing LED bulk head light fitting 1X10watts complete including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of suitable size all as required complete
S&F LED Lamp 9 watt 230 volts complete all as specififed and direccted.
Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete.
Supply & Fixing for sheet metal enclosure MCB distribution board, double door with IP43 -IK09 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete
S&F MCB distribution board SPN, 240 volts, 8 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete.
Supply & Fixing for sheet metal enclosure MCB distribution board, double door with IP43 -IK09protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete.
S & F Distribution board (ETPN)iron clad, double door with IP-54 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete Including with one MCCB 3 pole 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site complete.
S&F tripple pole and neutral, powder coated, CRCA steel sheet Vertical bus bar distribution board (VTPN) constructed as per IS 8623 , IP-54 1K-09 suitable for MCCB incomer upto 125 amp, 4 way, 415 volts, degree of protection IP 43, mechanical strength IK 08 with metal door, recess mounted, having 200 amp insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required complete
S&F in Wall LED light fitting including fixing arrangement on wall with suitable size of GI pipe bend into shape, clamps and nut & bolts for fitting capacity of LED 20 watt, with pressure diecast aluminum housing & polycarbonate having top opening seperate driver compartment with IP66 protection and impact resistance IK07 duly prewired connection complete.
S&F MCBs of 'B' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
Single pole 6 to 32 amp.
Double pole 6 to 32 amp.
Four pole 32 to 63 Amp
S&F Ding dong bell, AC, 240 volts, complete.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete.
Taking down carefully aluminium or copper submain wiring with PVC casing caping / PVC surface conduit and making good disturbed surfaces complete.
Electricals India
ALBA AC AND REF SERVICES
r s corporation
Shree Krushna Supply Corporation
M/S VENUS BUILDER
MAA PUNAGRI ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .