Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.0 LAccepted-Finance | 1 | Accepted-Finance L1 LOWEST BIDDER | |
| 2 | 2₹18.2 L+₹3.2 L (21.5%)Rejected-Finance 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | 2 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 3 | 3₹18.9 L+₹3.9 L (26.2%)Rejected-Finance | 3 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 4 | 4₹19.4 L+₹4.4 L (29.6%)Rejected-Finance | 4 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 5 | Rejected-Technical | - | Rejected-Technical EXPERIENCE NOT PROPER |
Tender Value
₹18.3 L
EMD Value
₹18,500
Closing Date
2 Aug 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC AZAMGARH
220KV S/S COLONY HAFIZPUR AZAMGARH
ERECTION OF 63 MVA T/F AND CONSTRUCTION OF NEW 132 KV AND 33 KV BAY AT 132 KV S/S SIKANDARPUR UNDER ETD, BALLIA.
2023_UPTCL_814916_1
38/AETC/2023-24
Open Tender
Electrical Works
Item Wise
60 days
BALLIA
UTR SLIP OF EMD TENDER FEE PAN CARD GST CERTIFICATE WORK EXPERIENCE etc.
2 documents required · 2 mandatory
₹590
SE ETC UPPCL AZAMGARH
₹18,500
1 Sept 2023
24 Jun 2023
3 Aug 2023
24 Jun 2023
2 Aug 2023
24 Jun 2023
24 Jun 2023 - 2 Aug 2023
Amount
Bolted type tension gun fitting suitable for Single ACSR Moose conductor
Bolted type tension gun fitting suitable for Single ACSR Panther conductor
Bolted type suspension gun fitting suitable for ACSR Moose conductor
P.G Clamp made of Aluminium alloy with 3 Nos. suitable size galvanized G.I. nut, bolts & washer for panther to panther conductor.
P.G Clamp made of Aluminium alloy with 4 Nos. suitable size galvanized G.I. nut, bolts & washer for moose to Moose conductor.
P.G Clamp made of Aluminium alloy with 4 Nos. suitable size galvanized G.I. nut, bolts & washer for moose to panther conductor.
Bimetalic terminal connector suitable for 33KV C. T to twin Moose conductor
Bimetalic terminal connector suitable for 33KV C. B to twin Moose conductor
Bimetalic terminal connector suitable for 33KV Isolater to twin Moose conductor
Bus post clamp Suitable for Moose
Bus post clamp Suitable for Panther
G.I Nut. Bolt with washer Size- 16x40 mm
G.I Nut. Bolt with washer Size- 16x45 mm
G.I Nut. Bolt with washer Size- 16x50 mm
70KN Disc insulator
40 mm MS Rod for main earthmat
40 mm Dia MS electrodeof 3 meter length
Part -B, Work (Erection of 63 MVA T/F) Shifting upto 20 M of main tank of 63 MVA ,132/33 KV transformer from unloading place to suitable place including turning of tank , if required. All T&P and all other associated works for completion of job satisfactory.
Additinal shifting of 5 meter a part therof 90 meter of 63 MVA 132/33 KV Transfomeer @5 meter per job.
Complete erection of 63 MVA, 132/33 KV Transformer by erection of radiators, conservator tank, all bushings, their turrets connecting all pipe lines, cooling fans, motor drive mechanism of tap charger, RTCC panels, and associated oil pipe lines etc to complete the job satisfactorily including first filling of oil and topping up of T/F oil (Not circulation) in tank radiators, oil pipe lines, conservator tank etc, and attending the oil leakage, if any and all other associated works for satisfactory completion of job. Crane and T&P shall be provided by the contractor
Complete earthing of 63 MVA, 132/33 KV Transformer by 75X10 mm/50X6mm M.S Flat including main tank of T/F , Marshalling box ,OLTC drive mechanism , RTCC Panel and connecting with existing earthmat of substation by (X&Y axis of main earth mat of the substation )cutting, bending welding thereafter painting including cost of M.S Flate, paint& brush etc .
Centrifuging of fresh transformer oil and filling of balance oil into the transformer with machine ,operator and to achieve final BDV & PPM testing results. Machine and operator will be provided by the contractor.
Construction of Delta earthing by piercing 3.00 meter long electrodes in earth and then connecting them with each other by 75x10 mm M.S flat and connecting to neutal bushing ,the same with main earthmate at 2 places (X&Y axis of main earth mat of the substation )as required, excluding the cost of M.S. Bar and M.S. flat to be provided by the department free of cost. and all other associated work to completion the job satisfactory.
Jumpering of 63MVA T/F HV side 1 X Panther conductor
LV side with 2X Moose conductor
Following Testing of t/f oil If any NABL Accredite lab the detail as:- BDV PPM DGA
Part -C, Work (Erection of 63 MVA T/F Bay) Sortng, counting and loading and carriage of substation structure (22MT) from EFU Naini Prayagraj to 132 KV S/S Sikandarpur and after carriage unloading it at 132 KV S/S Sikandarpur. Sortng, counting and loading of G.I S/S Structure (22 MT) at EFU Naini .
Carriage of S/S Structure(22MT ) from EFU Naini Pryagraj to 132 KV S/S Sikandarpur (Approx distance 310 KM) (22M.T X310KM )=6820
Unloading and stacking of G.I Structure(22 MT) at 132 S/S Sikandarpur.
Erection of Main and auxiliary structure by shifting of structure from store to work site as per relevant drawing and practices using Nut - Bolt and spring washers .The material shall be supplied by department free of cost but the contractor has to manage T&P and all other associated work to complete the job satisfactory.
Stringing of 132 KV Jack Bus bar ( R, Y & B phase ) with ACSR single Panther conductor including cutting, bending and clamping fitting of tension clamp with all associated accessories, hoisting of insulator string after shifting of material from store to work site and all other associated work to complete the work satisfactory.
Stringing of 132 KV Main Bus bar ( R, Y & B phase ) with ACSR single Moose conductor including cutting, bending and clamping fitting of tension clamp with all associated accessories, hoisting of insulator string after shifting of material from store to work site and all other associated work to complete the work satisfactory.
Stringing of 33 KV Main/Transfer Bus bar ( R, Y & B phase ) with ACSR Single Moose conductor including cutting, bending and clamping fitting of tension clamp with all associated accessories, hoisting of insulator string after shifting of material from store to work site and all other associated work to complete the work satisfactory.
Erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material from store to work site includig all other associated work to complete the job Satisfactory. 120 KV LA
145 KV BSI
145 KV SF6 ,CB
Junction box for 145 KV CT
Junction box for 36 KV CT
Junction box for 36 KV PT
36 KV VCB
36 KV BSI
Relay & control panel for 63MVA Power Transformer.
33KV Tripple feeder control & relay panel
Erection of ABT Energy Metering panel with main and check rack
Jumpering of equipments using single/double panther/zebra/moose conductor from bus bar to isolators,CB,CT,LA, etc on both sides required.
Laying of follwing size control cables from control & relay panels to Transformer marshalling box, various equipment junction boxes etc in switchyard as per cable schedule, its binding at every 1.5 mtr. distance with M.S. saddle including carriage of cable from store to work site and shifting back to store and all associated works to complete the job satisfactorily. 2C x 2.5 sq. mm
4C x 2.5 sq. mm
6C x 2.5 sq. mm
Termination of above cable as per cable schedule including making necessary holes in gland plates of boxes where ever required including Supply and fixing of cable glands of approxinmate size and to provide ferrules and nos. for each core of cable and its termination with all the other associated works to complete the Job.
Delta earthing of 120 KV and 30 KV LA consisting of 03 Nos 3 meter long electodes its placing inside the ground and connecting all three electrodes with 75x10 mm MS flat and connecting the same with LA at two place required including cost of M.S strip excluding cost of M.S round bar
Earthing of Main & Auxiliary structure and various type equipments (CT, PT, CB, LA, LSI, BSI etc ) by M.S strips by cutting to proper size, digging of earth from ground level to earthmat then proper welding as per drawing and leveling earth. Painting of M.S Strips of one coat red oxide primer and two coat with green colour and all associated work to complete the job satisfactory . M.S Flat will be provided by the contractor. 75 x 10 mm
Laying of 40 mm dia. Round bar 700 mm below ground level including cutting straightening ,welding painting excavation of earth in trench from back filling after completion of work with all other associated work to complete the job satisfactory ,excluding cost of 40mm dia round bar.
Fabrication of 3 meter long electrode with 40 mm MS round bar having 150 mm conical shape and then its piercing vertically inside the ground with top 700 mm below ground level and its welding exluding cost of 40 mm dia. Round bar
Fabrication of Fire bucket stand having of 2100x1100x150 mm with 10Nos bucket Hookes in two racks then painting one coat red oxide primer and two coats red colour standerd make paint . Then wiriting Fire in size 12 mm height on top cover end rounded side plate and all other assocaited works including cost of material and labour . Angle will be provided by UPPTCL.
Hi-tech power transmission
M/s S.S. Refregeration
M/s. ADITYA TRADING CO., KM-383, RAIDOPUR OFFICERS COLONY, AZAMGARH, U.P.-276001.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .