Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹8.1 L+₹60,901 (8.15%)Rejected-AOC 2ND 6 KEDIA HOUSE MA ROAD BYELANE 1 REHABARI GUWAHATI ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | L2 | Rejected-AOC NOT LOWEST |
Tender Value
₹8.6 L
EMD Value
₹17,200
Closing Date
9 Feb 2023, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR AND MAINTENANCE OF STREET LIGHTS AND CONNECTED WORKS AT KOTDWARA AND LANSDOWNE UNDER AGE I LANSDOWNE
2023_MES_573866_1
8806/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
AGE I Lansdowne
Class E Cat b i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹17,200
20 Mar 2023
9 Jan 2023
11 Feb 2023
9 Jan 2023
9 Feb 2023
23 Jan 2023
Amount
Supplying and erecting in true vertical position steel tubular swaged pole, 9 meters long, type 410 SP-31, complete as per IS-2713 with MS iron base plate of 06mm with pole cap, finial taper plug , bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:4:8 type D-2, (using 40mm graded stone aggregage) and PCC 1:3:6 type C2, (using 40mm graded stone aggregate) as in plinth block, disposal of surplus soil to a distance not exceeding 50 mtr, painting two coats of aluminium paint over one coat of red oxide primer including tarring one coat on steel surface embedded in concrete and 05 Nos strips of 250mm height from coping comprising & black yellow paint in alternative layer complete all as specified and directed. Note:- Required earth work, PCC foundation will be paid separetly under relevant items of Sch A.
Supply, install and testing in repair LT Feeder pillar panel cubical outdor type made out of CRCA Sheet 3.00mm front hinged openable door including locking arrangement, platform mounted with angle iron 40mmx 40mmx 5mm frame work suitable for 440 volts grade three phase 4 wire 50 Hz AC Supply system, having bus bar chamber with suitable aluminium bus bar 100 Amp rating and accomodated with 63 Amp MCB TPN, with digital 24 Hr timer and making all necessay electrical connection complete, the box shall be dust and vermin proof IP-54 class protection alongwith in built short circuit protection confoms to IS/IEC 60947-4-1 complete all as specified and directed .
M&L laying or passing through pipe LT UG XLPE PVC insulated,steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core including taking out old unserviceable cable complete all as specified and directed.
Description same all as per sel Item No 03 here in above but 16 sqmm 4 core complete all as specified and directed.
Description same all as per sel Item No 03 here in above but 10 sqmm 4 core complete all as specified and directed.
Description samen all as per sel Item No 03 here in above but 10 sqmm 2 core complete all as specified and directed.
Supply and fixing bracket made out of 40mm bore, steel tubings, galvanised, light grade not less than 1.2 mtr long bend to shape with all fitting including fixed on pole with 02 Nos MS Clamp made out of F1 32x6mm complete all as specified and as directed.
Supplying, laying & jointing GI tubing light grade ISI Marked of size 40mm bore, in trenches/pole post/under culvert/under road etc for cable porection, complete all as specified and directed.
Disconnecting and dismantling old U/S pole box and S&F Loop in and Loop out FRP rectangular SMC junction box (Pole Box) front openable hinged from side of size 240x130x110 mm suitable for outdoor installation weather proof having 4 pole cable connector (for cable in and out junction) fixed inside box with insulator support and 01 nos MCB SP 06 Amp fixed inside box complete for street light fitting with MS clamps 40x5 mm GI nuts, bolts and washers complete all as specified and directed. Make of Box:- Sintax/Hensel/EPP/Universal switchgear & control
Dismantling and taking down the existing old unsv street/flood light fittings of any type and any capacity from steel tubular pole/wall, checking for servicieability and replacing the defective parts as LED driver, PCB etc and Refixing the same on existing pole/wall or other different location directed by EIC complete all as specified and as directed. Note : (i) Defective parts of light fittings shall be measured and paid separately. (ii) The T&P , vehicle and necessary ladders etc will be arranged by the contractor and the cost of the same deemed to be included in the quoted rate. (iii) Unit rate shall also include replacement of U/S wiring from OH lines to ligtht fittins and minor spares also.
Supply only LED driver with PF>0.95, input voltage 240 V AC, 50 Hz, input current 0.25 Amp AC, output voltage 42V-72V DC, output current 0.7A DC THD<10%, line volatge 140 to 277 V, IP 20 protection as per IS:15885(part-II section 13) suitable for LED street light of 25 Watt to 45 Watt outdoor dry and damp application (Size of driver should be as per sample given by EIC) complete all as specified and directed
Supply only LED driver with PF>0.95, input voltage 240 V AC, 50 Hz, input current 1.6 Amp AC, output voltage 42V-72V DC, output current 0.7A DC THD<10%, line voltage 140 to 277 V, IP 20 protection as per IS:15885(part-II section 13) suitable for LED street/Flood light of 50 W to 90Watt outdoor dry and damp application (Size of driver should be as per sample given by EIC) complete all as specified and directed
Supply only PCB 45 to 60 watt suitable for LED street light, flood light outdoor type (size of PCB should be as per sample given by EIC) complete all as specified and directed.
S&F flexible 3 core PVC insulated unsheathed FRLS-H cable of size 1.5 Sqmm, 1100 volts grade heavy duty multi stranded copper conductor drawn through in non metallic rigid PVC conduit for making electrical connection of street light with poles junction box, complete all as specified and directed. (Note:- PVC conduit shall be measured and paid separately under respective item)
S&F non metallic rigid PVC conduit of size 20mm dia, medium grade, inclusive tees/bends//elbows/ reducers/bell mouth tube ends and fixing accessories fixed on poles from junction box to light fitting with fittings like mild steel clamps, nut & bolts etc. complete all as specified and directed.
Excavation in trenches in any type of soil n.exc 1.5 m wide and n.exc 1.5 m in depth for poles,laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out, trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed.
Returning filling in any type of soil including spreading, levelling, watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
Removal of excavated surplus any type of soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid.
M&L for burnt bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
M&L PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in mass concrete/foundation complete all as specified and directed.
M&L PCC 1:4:8, type D-2, ( using 40mm graded stone aggegate) as in foundation and posts including caps and bases complete all as specified as directed.
Supply & Fixing in repair of power contactor three pole 60 Amp 415 Volts din rail mounted type on existing panel complete all as specified and directed.
Supply & Fixing in repair of power contactor three pole 40/32 Amp 415 Volts din rail mounted type on existing panel complete all as specified and directed.
Supply & Fixing in repair of 24 hour analog time switch, din rail mounted type on existing panel complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B-1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Material and labour for servicing of high mast light including of Oiling & greasing of wire rope and driving Motor complete all as specified and directed.
Supply and fixing in replacement of PVC LT Line seperators 4/5 way complete all as specified and directed.
Supply and fixing in replacement of PVC LT Line seperators 2/3 way complete all as specified and directed.
ADITI CONSTRUCTION CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .