Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.1 CrAccepted-AOC | ₹1.1 Cr | 1 | Accepted-AOC Being Lowest Bidder |
| 2 | 2₹1.1 Cr+₹4.0 L (3.74%)Rejected-Finance | ₹1.1 Cr+₹4.0 L (3.74%) | 2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | 3₹1.1 Cr+₹6.3 L (5.84%)Rejected-Finance | ₹1.1 Cr+₹6.3 L (5.84%) | 3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | 4₹1.2 Cr+₹7.9 L (7.32%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹1.2 Cr+₹7.9 L (7.32%) | 4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | 5₹1.2 Cr+₹10.0 L (9.25%)Rejected-Finance | ₹1.2 Cr+₹10.0 L (9.25%) | 5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
12 May 2021, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Special Repairs to DSC Building at Dega Vihar, Visakhapatnam
2021_MES_434886_1
82133 / E8
Open Tender
Civil Works
Item Rate
270 days
Visakhapatnam
Class B
Category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Depot
₹2.2 L
Yes
23 Jun 2021
7 Apr 2021
19 May 2021
7 Apr 2021
12 May 2021
28 Apr 2021
7 Apr 2021 - 14 Apr 2021
Amount
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
S & F Solid PVC door frame of size 100mmX45mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F Factory made, 35mm thick, Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc. [without Sash Bars], edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [a] and fitted to Chowkats complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed.
S & F Factory made UPVC Sliding Window, Three Track, White Colour of area not exceeding 2.0 Sq.m, made of extruded profiles with wall thickness of 2.3mm±0.2mm, Window profile with hollow section with multi chamber, Frame of size 88mm X 52mm, Sliding Sash of size 42mm X 67mm, Sliding Mesh Sash of size 42mm X 57mm, Sliding Interlock [One vertical length in each shutter] of size 45.50mm X 28mm, Glazing Bead of size 24.50mm X 16mm shall be mitred cut and fusion welded at all corners, including drilling holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM Gasket, 1.2mm±0.2mm thick Galvanized Steel Frame of size 30mmx 18mm, 2 Nos, Sliding Sash of size 30mm x 18mm, Sliding Mesh Sash of size 26mm x 10mm profile to be inserted in required profile, frame shall be fixed to the wall with 8mm X 100mm long fasteners, Hardware such as Touch lock of zinc alloyed [white powder coated], Steel roller system, Stainless Steel Wire Cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories shall be provided with proper operative and locking hardware mechanism, frame shall be fixed to wall with high quality fasteners and silicon glue shall be applied to fill up gap between frame and wall to make leak proof complete all as specified and as per Manufacturer instructions. Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.
S & F Factory made, 35mm thick, Second Class Hard Wood, Plain framed, Panelled Shutter [Two Panel] with Lock Rail and Panel of 9 mm BWP Commercial Ply or 12 mm Veneered Particle Board with Commercial Veneering on both faces, the size of Rail and Stile as per IS – 1003 [Part – I], Kiln Seasoned and Chemically Pressure treated and fitted to Chowkats complete all as specified and as directed.
M & L for Preparing surfaces of wood and wood based materials, steel and iron work new or old, of any description and girth not otherwise described, and treating ends of posts, backs of Chowkats, etc. area tarred exceeding 0.1 Sq.m and not exceeding 0.5 Sq.m each with tar or coal tar black paint complete all as specified and as directed.
Supply only Powder Coated Aluminium Deco Grill of Model / Design No. DG 104 including Powder Coated Aluminium Channel of size 30 X 12 X 1.5mm for fixing Deco Grill complete all as specified and as directed.
S & F Factory made PVC Ventilator made out of multi chamber PVC hollow section DWUF 405 [40x46mm] with 3mm pin headed glass fixed to the lower section using extruded PVC section of 9 X 19.5mm size OL19 with EPDM gasket [SPL 003] for both PVC sections, ventilator's centre mullion shall be made up of multi chamber hollow PVC section DWUF-406 [63.5mmX40mm] with EPDM gasket GL-19 and fixed to the 3 sides of DWUF-405 and DWUF 406 [63.5X40mm] above the centre mullion, Glass panels with aluminium lower set shall be fixed to the frame DWUF-405 on the top of the ventilator for the glass, DWUF 405 and DWUF 406 comers shall be mitred cut and welded, jointed with 12mm MS Rods [Guard Bars] including necessary fixtures complete all as specified and as directed.
M & L for PCC 1:2:4, Type B-1, using 20 mm graded stone aggregate as in Bed blocks and Bed plates including weathering, slightly rounded or chamfered angles and throating, necessary form work etc complete all as specified and directed.
S & F Mild Steel work conforming to Fe - 290, Grade E-165 as in Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes, including Bolts, if required, Hooks [Stay], heavy, for Large Gates, Hook and Pintle Hinges, large Hasps and Staples, Chains, hand made Sliding Bolts, Clamps, Hold Fasts, Wall Ties, Hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
M & L for Plain / Reinforced cement concrete Type B1 [Nominal Mix] 1:2:4 using 20mm graded stone aggregate cast in situ in lintels up to 1.5m span, Cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and as directed.
Supply only 4mm thick sheet glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
S & F Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm and fixed with tinned tacks or stainless steel wire staples with new wooden beading including necessary painting to beading to match with existing surfaces complete all as specified and as directed.
S & F in repairs Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm and fixed with tinned tacks or stainless steel wire staples with new wooden beading including necessary painting to beading to match with existing surfaces complete all as specified and as directed.
S & F 100 mm size, Butt hinges, Extruded Aluminium alloy with galvanised mild steel hinge pin, anodised, Type B-21, including fixtures complete all as specified and as directed.
S & F Hasp and Staple, safety type of aluminium anodised including bolt to hinge plate, fixed with screws of 100mm size complete all as specified and as directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 100mm long complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 100 mm size of extruded section complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F Harrison Rails [Curtain Rails], Anodised Aluminium, 25 mm dia with fixing brackets, stops, rollers etc complete all as specified and as directed.
S & F Mild Steel Door Spring 375 mm, Ordinary Rat Rail Rod Pattern springs including roller and roller plate complete all as specified and as directed.
S & F in repairs white Vitreous China Squatting Pan "Orissa Pattern" of size 580 mm X 440 mm with integral foot rests and 'P' or 'S' Trap including provision of lime concrete bedding and 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe complete all as specified and as directed.
S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed.
S & F in repairs PTMT Grating Doom, 100 mm dia [Minimum weight 25 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and directed.
S & F in repairs Brass Chromium Plated Shower Rose of size 125mm with or with out swivel joints fixing to steel pipes complete all as specified and as directed.
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 20 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Stainless Steel, Tubular Towel Rail, D Type, 600 mm long between flanges complete all as per Jaquar Catalogue No. ACN-1111SM or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Zinc rich epoxy primer to all steel surfaces as antirust agent and welding steel wire Fabric / Mesh of size 75X25mm of weight not less then 3.0KG per Sq.m to existing reinforcement, applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 40mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable bonding agent of M/s. Fosroc Chemicals or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
Demolition of Stone Slab laid, bedded and pointed in Cement Mortar of thickness not exceeding 25 mm and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for machine cut Kota stone slab flooring using 20 to 25mm thick slabs, laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including diagonals, inlays, borders, margins in two or more shades of slabs including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
S & F in repairs 150mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F in repairs 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F 150 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F Sand Cast, Cast Iron, soil / waste / vent pipes, 50mm bore, in any length with or without ears, jointed with cement sand mortar, laid in trenches or in floors including Demolition and breaking up Cast Iron of any diameter set in cement mortar complete all as specified and as directed.
S & F CI Bends [any radius] with duck's foot or heel rest of 50mm bore, for Cast Iron soil / waste / vent pipes complete all as specified and as directed.
S & F in repairs 50mm dia out let, Cast Iron Floor Trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4, Type B-1 complete all as specified and as directed.
S & F in repairs 75mm bore Cast Iron Nahani Trap with grating including jointing to waste pipe, fixed in cement concrete type B1, 1:2:4 complete all as specified and as directed.
S & F GI water tubing of 15 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed.
S & F GI water tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed.
S & F GI water tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed.
S & F in repairs Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as per Jaquar Catalogue No. CON-083KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type, Short Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-047KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as per Jaquar Catalogue No. CON-011KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 6mm dia bars at every fourth course of brick work complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Supply only integral water proofing compound [ISI marked] of approved make.
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc. surface finished even and smooth with out using extra cement complete all as specified and as directed.
M & L for 100 mm thick, PCC 1:2:4, Type B-2, using 40mm graded stone aggregate as in Sub base for flooring complete all as specified and as directed.
M & L for Glazed Polish finished coloured Chequered Cement Concrete Tiles of thickness 23 to 25mm, made with M-25 Grade Precast Cement Concrete, Hydraulically pressed of size not less than 300 X 300 mm, of approved shape, colour and pattern, set, jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
Demolition of Reinforced Cement Concrete as in Roof, Floors [other than ground floor], beams, staircase, landing, Chajjas and similar suspended work including reinforcement cut as required to facilitate demolition and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for RCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Slabs supported on walls, beams, columns, landings, shelves, Chajjas and the like complete all as specified and as directed.
M & L for providing RCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Precast Landings, Cover Slabs [for manholes etc], Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified and as directed.
Use and removal of steel formwork to Chullah hoods, Chajjas, troughs and similar items including edges and similar works for fair finished surfaces of concrete complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment of soil under existing floors using chemical emulsion @ 1 litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment along external walls below concrete or masonry apron using chemical emulsion @ 2.25 litres per RM by drilling 12 mm dia holes up to 300 mm deep and 300 mm centre to centre including plugging holes complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment at points of contact of wood work by chemical emulsion [in oil or kerosene based solution] @ 0.5 litre per hole by drilling 6 mm dia holes at a downward angle of 45 degrees at 150 mm centre to centre and sealing the same complete all as specified and as directed.
M & L for preparing newly plastered wall surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for preparation of old plastered or unplastered surfaces including brooming down or steel wire brushing and applying one coat of white wash on walls complete all as specified and as directed.
M & L for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for preparation of old plastered or unplastered surfaces including brooming down or steel wire brushing and applying one coat of white wash on ceilings complete all as specified and as directed.
M & L for preparing newly plastered Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for preparing newly plastered Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
S & F in repairs Plain Mild Steel Wire, Galvanised Class 3, in Fencing including straining and fixing to Wood, Concrete or Steel Posts and/or to Straining Bolts, including securing with and provision of Galvanised Iron tying wire, Galvanised Iron Staples or Steel Pins, etc. as in detached work such as for Mosquito Nets and fixing to Straining Bolts, Hooks, Eyes, etc. complete all as specified and as directed. [Note: Each line of wire shall be measured as One Unit]
M & L for concrete bed to drain pipes of size 150 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed.
M & L for 150 dia for Salt Glazed Stoneware Drain Pipes of Grade "A" laid in trenches and jointed including Demolition and breaking up drain pipes [Salt glazed ware, AC or Reinforced concrete] of any diameter set in cement mortar complete all as specified and as directed.
M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size not exceeding 0.36 Sq.m, 9 to 10 mm thick as in Floors, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Floors, Treads of Steps, Window Cills, Cooking Platform etc., and the like with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: Single stone slab shall be used for entire Width and Length of Steps, Window Cills, Cooking Platform etc. and joints shall match with the flooring. The edges of treads shall be bull nosed / half rounded. The edges of the treads and landings shall also be provided with three Nos of grooves.
M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Skirting, Dado, Risers of Steps, Jambs, Pillars, Wall Lining [Veneering to Wall] etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including diagonals, inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: Single stone slab shall be used for entire height of Skirting / Dado / Risers and joints shall match with the flooring.
S & F in repairs Stainless Steel Railing made with Stainless Steel Pipes of wall thickness not less than 1.6mm, of Grade AISI 304, standard quality, bright polish finish, using 50mm dia pipes for hand rail, 25mm dia pipes for vertical supports / balusters and 25mm dia pipes as in tie bars in three layers, SS tubes shall be welded at the turnings and junctions, welded portions shall be completely grinded and brought to bright and smooth finish including all bends, elbows, making holes in the floor / steps, grouting with epoxy to achieve full strength of railing complete all as specified and as directed.
S & F Calcium Silicate False Ceiling made out of 15mm thick, 595 x 595 mm size Tiles of siliceous and calcareous material reinforced with cellulose fibre fixed to the Exposed Metal Frame Ceiling Grid of 600mm x 600mm size and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer and including Exposed Metal Frame Work using GI Main "T" Runner of size 25X35mm, 0.7mm thick, spaced 1200mm centre to centre, Cross "T" of size 25X35mm, 0.7mm thick, 1200 mm long spaced between Main "T" at 600 mm centre to centre to form a grid of 1200X600 mm and secondary Cross "T" of 600mm long and of size 25X35mm, 0.7mm thick of the 1200x600mm panel to form grid of size 600x600mm, resting on periphery walls / partitions on GI Perimeter Wall Angle of size 25X25X3000 mm, 0.70 mm thick with the help of rawl plugs at 450mm centre to centre with 35mm long dry wall screws including cutting/making opening for services like diffusers, grills, light fittings, smoke detectors etc., wherever required. Main "T" Runners shall be suspended from ceiling using GI Soffit Cleats made of GI Channels of 1.8 mm thick, having unequal flanges of 37 mm and of 25 mm and web of 25 mm fixed to ceiling with 6mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised steel level clips of size 85x30x2mm, spaced at 1200mm centre to centre along Main "T". Bottom exposed width of 25 mm of all sections shall be pre-painted with polyester baked paint at all heights including Dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified and as directed.
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified. Note: Rate quoted is also deemed to be inclding cost of Cutting chases, pinning in Brick Walls, making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed.
All as per Serial Item No. 98 above but for One Light Point controlled by Two Nos. of, Two way Switches complete all as specified and as directed.
All as per Serial Item No. 98 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 98 above but for One 3 pin Socket Outlet 5 Amps on the Same Board with other switches complete all as specified and as directed.
All as per Serial Item No. 98 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, Two Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, One Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F Bell Push, Flush Button, Single Pole, 5 Amps, 230 Volts complete all as specified and as directed.
S & F Bell, Ding Dong / Multi Music Type, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F Lamp Holder, Insulated Body with Back Plate, 230 Volts for Batten Fittings complete all as specified and as directed.
M & L for Taking down Ceiling Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, replacement of Spares such as Capcitor 2.5 Mfd, Bearings, Shaft Bushes, Capacitor, Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts etc. as required and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
M & L for Rewinding of Motor of Ceiling Fan of any description using super enamelled copper conductor of suitable gauge including insulation, varnishing, packing and testing etc., cleaning, greasing etc. complete all as specified and directed.
Taking down Exhaust Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, cleaning, greasing etc and replacement of Spares such as Capacitor 4 Mfd, Bearings, Shaft Bushes, Condenser, Rubber Bushes, Nuts & Bolts etc. and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
M & L for Rewinding of Motor of Exhaust Fan of any description using super enamelled copper conductor of suitable gauge including insulation, varnishing, packing and testing etc., cleaning, greasing etc. complete all as specified and directed.
Taking down Split Air Conditioner including Outdoor unit of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up, cleaning, carrying out minor repairs and replacement of Nuts & Bolts etc. including MS Stand / Bracket suitable for fixing Outdoor Units of Split ACs of different capacities, recharging with suitable refrigerant gas as required and necessary scaffolding etc. for complete all as specified and as directed. Note: Rate quoted is deemed to be inclusive of safe custody of the Air Conditioers during B/R works including cleaning and minor repairs, making good any damages caused during the custody to match with the original fitting complete all as specified and as directed.
Taking down Air Curtains of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up, cleaning, carrying out minor repairs and replacement of Nuts & Bolts etc. including fixing Brackets etc of different sizes and necessary scaffolding etc. for complete all as specified and as directed. Note: Rate quoted is deemed to be inclusive of safe custody of the Air Curtains during B/R works including cleaning and minor repairs, making good any damages caused during the custody to match with the original fitting complete all as specified and as directed.
S & F in repairs Down Rod suitable for Ceiling Fan of any sweep made of 15mm dia GI Pipe of 0.50 to 1.00 metre length including Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts etc. as required and also including cleaning and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
S & F in repairs Down Rod suitable for Ceiling Fan of any sweep made of 15mm dia GI Pipe of 1.00 to 1.50 metre length including Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts etc. as required and also including cleaning and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
Taking down Light Fittings of any description and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including cleaning and minor repairs, making good any damages caused during the custody to match with the original fitting complete all as specified and as directed.
S & F in repairs Heavy duty PVC Conduit, 20 mm dia concealed in Walls / Roofs / Floors / Ceiling etc. inclusive of boxes [Junction / Terminal but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for drawing Coaxial TV Cable or Telephone Cable or LAN Cable etc. complete all as specified
S & F in repairs Heavy duty PVC Conduit, 25 mm dia concealed in Walls / Roofs / Floors / Ceiling etc. inclusive of boxes [Junction / Terminal but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for drawing Coaxial TV Cable or Telephone Cable or LAN Cable etc. complete all as specified
S & F in repairs MCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar, IP43 rated suitable for mounting MCBs complete all as specified and as directed.
S & F in repairs MCCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar, IP42 rated suitable for mounting MCBs and provision for MCCB as incomer and including MCCB, TP, 160 Amps, 25 KA, 415 Volts, 50 Hz complete all as specified and as directed.
S & F MCCB, TP, 100 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F MCB, TP, 63 Amps, 10 KA, C Curve, AC, 415 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, TPN, 63 Amps, 10 KA, C Curve, AC, 415 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SPN, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F in repairs Power Socket, 20 Amps with 2 Pole and Earth Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts, 4 Modules, Modular Type Pressed Metal Flush Box and Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches & Sockets etc. complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit. Rate quoted is also deemed to be inclding cost of Cutting chases, pinning in Brick Walls, making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit. Rate quoted is also deemed to be inclding cost of Cutting chases, pinning in Brick Walls, making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed.
M & L for Sub main wiring with 4 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 40 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 5 runs of 10 Sq.mm & one run of 40 mm dia PVC Conduit will be measured as one unit. Rate quoted is also deemed to be inclding cost of Cutting chases, pinning in Brick Walls, making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 35 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
Supplying and laying GI pipe, 50mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
Cutting Bituminous Road / Hardstanding etc. as required for Jointing / Laying Cables and Pipeline of width not exceeding 300mm and depth not exceeding 600mm and refilling after laying and making good with PCC 1:2:4, Type B1 using 20mm graded stone aggregate, 100mm thick complete all as specified and as directed.
S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 25 X 4mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Earth continuity Conductor or main earthing lead made of GI Wire of 8 SWG, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 25 X 4mm GI Strip [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
SUPREET CONSTRUCTIONS
CIVILEC ENGINEERING WORKS
RAGHU RAMA PANDA
SRI THULASI TECH
Mavee Syndicate
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .