Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.4 LAccepted-Finance 3 4 JEEVAN DEEP BUILDING 10 PARLIAMENT STREET NEW DELHI 1 PH 011 43573493 9899713006 | ₹72.4 L | L1 | Accepted-Finance Being Lowest Bidder |
| 2 | L2₹81.6 L+₹9.2 L (12.7%)Rejected-Finance | ₹81.6 L+₹9.2 L (12.7%) | L2 | Rejected-Finance Being 2nd Lowest |
| 3 | L3₹98.9 L+₹26.5 L (36.6%)Rejected-Finance | ₹98.9 L+₹26.5 L (36.6%) | L3 | Rejected-Finance Being 3rd Lowest |
| 4 | L4₹1.0 Cr+₹27.7 L (38.3%)Rejected-Finance 405 406 FF NILKANTH PALACE OPP KARMA SHRSTHAN TOWER 100 FT ROAD JODHPUR SATELLITE AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | ₹1.0 Cr+₹27.7 L (38.3%) | L4 | Rejected-Finance Being 4th Lowest |
| 5 | L5₹1.1 Cr+₹40.6 L (56.1%)Rejected-Finance | ₹1.1 Cr+₹40.6 L (56.1%) | L5 | Rejected-Finance Being 5th Lowest |
| Sl No | Description | Qty | Unit | M/s. PRANAM HVAC ENGINEERING PVT. LTD. L4 | SNOWMEX ENGINEERS LIMITED L1 | Ingenious Industries L3 | AirBizz AirConditioning Pvt. Ltd. L5 | Mvac Engineers L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing and commissioning of factory built (suitable for assembling at site in operational terminal Building AHU room) floor mounted chilled water double skin type horizontal Air Handling Units made with Thermal Break Profile 46 -50 mm panel thicknes consisting of pre plasticized G.I. casing of thickness 1 mm outside layer and 1 mm inside layer with CFC free polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure of 70 mm WC, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick washable synthetic type air pre-filters, MERV-8 Pre-filter section (90% down to 10 microns) with UV light, backward curve belt drive DIDW blower fan package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for variable frequency drive applications, drain connections, stainless steel (1.25mm thick) drain pan with PUF insulation,3mm thick galvanised steel base channel frame, 150 mm dia. dial type Stainless steel pressure gauges (2 Nos.) and industrial type thermometers (2 Nos.) at the inlet and outlet of AHU including test points and necessary vibration isolation arrangement, Duct flexible connector (fire proof) shall be provided at outlets and return connection of AHU etc. with SITC of starter panel with VFD (fabricated out of powder coated 16 gauge CRCA sheet) and control accessories i/c LED indicating lamp, Sensor for operation of fire damper, inter connection to AHU and other accessories as per specification for following capacities. VFD should have suitable comunication port to work with BMS system, starter panel should have minimum 04 potential free contacts. Safety Features : 1) The Fan Access Door shall be equipped with micro-switch inter locked with fan motor to enable switching off the fan motor automatically in the event of door opening. 2) The Access Door shall further have wire mesh screen as an added safety feature bolted on to the unit frame. 3) Fan and motor base shall be properly grounded. | ||||||||
| 1.01 | 35000 CFM | 1 | Job | 18,10,000 ₹18,10,000 | 13,28,562 ₹13,28,562 Lowest | 19,04,500 ₹19,04,500 | 16,70,921 ₹16,70,921 | 13,49,450 ₹13,49,450 |
| 1.02 | 23500 CFM | 2 | Job | 12,05,000 ₹24,10,000 | 9,01,520 ₹18,03,040 Lowest | 12,54,240 ₹25,08,480 | 12,45,657 ₹24,91,314 | 9,43,930 ₹18,87,860 |
| 1.03 | 15000 CFM | 2 | Job | 8,21,000 ₹16,42,000 | 6,04,160 ₹12,08,320 Lowest | 7,41,000 ₹14,82,000 | 7,74,493 ₹15,48,986 | 6,24,040 ₹12,48,080 |
| 1.04 | 10000 CFM | 1 | Job | 6,50,000 ₹6,50,000 | 4,77,000 ₹4,77,000 | 5,78,110 ₹5,78,110 | 5,64,992 ₹5,64,992 | 4,52,100 ₹4,52,100 Lowest |
| 2.00Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the AHU Room in the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastrometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.034 W/MK or better at 20 deg mean temperature class ‘O’ insulation 32 mm thick with Glass Cloth pre-applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. | ||||||||
| 2.01 | 125 mm dia (32 mm GC insulation) | 18 | Rtm | 3,100 ₹55,800 | 100 ₹1,800 Lowest | 3,491.25 ₹62,842.5 | 4,478 ₹80,604 | 2,710 ₹48,780 |
| 2.02 | 100 mm dia (32 mm GC insulation) | 24 | Rtm | 2,500 ₹60,000 | 2,291 ₹54,984 | 2,930 ₹70,320 | 3,793 ₹91,032 | 2,240 ₹53,760 Lowest |
| 2.03 | 80 mm dia (32 mm GC insulation) | 24 | Rtm | 2,000 ₹48,000 | 1,563 ₹37,512 Lowest | 2,206.25 ₹52,950 | 3,280 ₹78,720 | 1,720 ₹41,280 |
| 2.04 | 65 mm dia (32 mm GC insulation) | 18 | Rtm | 1,700 ₹30,600 | 100 ₹1,800 Lowest | 1,896.25 ₹34,132.5 | 2,816 ₹50,688 | 1,440 ₹25,920 |
Tender Value
₹1.1 Cr
EMD Value
₹3.4 L
Closing Date
30 Oct 2025, 11:00 amClosed
AGM (E-E)-II, AAI, Surat International Airport
AGM (E-E)-II, AAI, Surat International Airport
Replacement of AHU, Valves and modification of piping in Terminal Building at Surat International Airport, Surat.
2025_AAI_250993_1
AAI/SRT/AGM(E-E)/25-26/eNIT-08
Open Tender
Electrical Works
Item Rate
150 days
AAI, Surat International Airport
19 documents required · 19 mandatory
₹1,180
Yes
₹3.4 L
17 Nov 2025
9 Oct 2025
31 Oct 2025
9 Oct 2025
30 Oct 2025
9 Oct 2025
9 Oct 2025 - 15 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 7.16 MB
Tender.pdf
Tender Documents • 7.53 MB
BOQ_288048.xls
BOQ • 0.84 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .