Loading…
Loading…
Tender Value
₹29.9 L
EMD Value
₹59,880
Closing Date
5 Oct 2026, 6:00 pm7d left
Executive Engineer
Office of Executive Engineer PHED District Rural Division Ajmer
Operation and Maintenance of Scheme originating from Nandla, PS6, Bithoor and Rajgarh pump houses including operation of pump house Bidakchiyawas under District Rural Division, Ajmer under jurisdiction of Rural sub division, Nasirabad
2026_PHCJA_600837_3
EE PHED District Rural Division Ajmer NIT NO 21 to 23
Open Tender
Civil Works
Percentage
365 days
Ajmer
AS per tender document
6 documents required · 6 mandatory
₹500
8745 EE PHED District Rural Dn Ajmer
₹59,880
Yes
26 Sept 2026
26 Sept 2026
6 Oct 2026
26 Sept 2026
5 Oct 2026
26 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Daily/ periodical operation of valves at supply times for specified by department per sluice valve per month. (95*12)=1140 (Valve rod and cap to be arranged by contractor) | - | - | - | - |
| 2 | 80-300mm | 1,140 | Each valve | 1,200 | ₹13,68,000 |
| 3 | Running expenditure of pumphouses which includes complete operation of pumpmotor , maintenance of log-books as directed by Engineer-in-charge, general upkeeping of premises, security arrangements, Regular chemical dosing in CWR, cleaning and desilting of SR/CWR/SUMP once every six months, daily valve operation under the Campus of pump house and all other works as mentioned in scope of work in tender document for per pump house per month. (power supply minimum 16 hrs) (Bidakchiyawas PH with 2 new OHSR ) | - | - | - | - |
| 4 | Upto 100 HP (excluding repairing of pumping machinery etc.)(12.5 HPx4 nos =50 Hpi.e.<100HP),(supply interval is 48 to 96Hr ,therefore rate is adopted proptinately on lower side for each month,i.e.,@12*75%=9 month utilisation as per BSR criterian | 12 | Each | 36,000 | ₹4,32,000 |
| 5 | Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost) | - | - | - | - |
| 6 | In all type Soil AC/PVC/HDPE pipe | - | - | - | - |
| 7 | 50/63/75mm | 40 | Each | 255 | ₹10,200 |
| 8 | 80/90mm | 180 | Each | 262 | ₹47,160 |
| 9 | 100/110mm | 120 | Each | 299 | ₹35,880 |
| 10 | 125/140mm | 40 | Each | 364 | ₹14,560 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
Nandla.pdf
Tender Documents • 2.19 MB
BOQ_1064860.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .