Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹26.4 L+₹53,180 (2.06%)Rejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L2 | Rejected-AOC BEING L2 | |
| 3 | L3₹27.4 L+₹1.6 L (6.17%)Rejected-AOC | L3 | Rejected-AOC BEING L3 | |
| 4 | L4₹37.0 L+₹11.1 L (43.0%)Rejected-AOC | L4 | Rejected-AOC BEING L4 |
Tender Value
Refer Docs
EMD Value
₹65,400
Closing Date
13 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Dehradun
HQ CWE Dehradun The Mall Road Dehradun Cantt
REPAIR AND MAINTENANCE OF MRS YARD, EQIUIPMENT AND CONNECTED ACCESSORIES AT IMA DEHRADUN
2021_MES_421541_1
8730/IMA/34/E8
Open Tender
Civil Works
Item Rate
120 days
Dehradun
As per NIT
8 documents required · 8 mandatory
₹500
GE IMA Dehradun
₹65,400
Yes
16 Apr 2021
12 Feb 2021
15 Mar 2021
12 Feb 2021
13 Mar 2021
26 Feb 2021
60 days
Amount
Material and labour for servicing 33 KV yard structure complete including replacement unserviceable jumper, sleeves, vice type connector, nut bolt and washers, connecting lugs/thimble, knife contact, applying petroleum jelly to the moving as well as fixed contacts, tightening all the connection for its smooth functioning preparing old painted surface of this structure such as poles, cross arms, bracing supports, clamp and back plate complete painting of two coats of anti corrosive weather proof heat resistant aluminium paints and providing Red/Yellow and Black paint including writing SM/MES No or all other direction/Marker/Code etc with grey/Black paint on boards etc not less than 40 mm height, 7-10 mm thick complete all as specified and directed. Note: No extra payment will made for the spares required to keep the yard structure in satisfactory functional state throughout contract period other then given in schedule complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth in soft/lose soil for laying cable/taking out underground cable, GI pipes and bricks laid under cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick in soft/lose soil after cable/pipes are laid and tested complete all as specified and directed.
Removing the excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed.
Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete all as specified and directed. Note :- Only punned down sand thickness 18 CM shall be measured and paid.
Supplying and laying old size bricks, laid flat ie length of brick shall be laid across the cable, common burnt clay building bricks sub class `B' designation 75 complete all as specified and directed and testing on completion complete all as specified and directed.
Supply and fixing of rotating type air break isolating switch horizontal mounting for triple pole, mechanically operated mounted on gang operated devices united on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200 Amps for 33000 volts complete all as specified and directed.
Supply and fixing of switches air break, gang operated triple pole with dropout fuse set 12 insulator, mechanically operated, mounted insulator and steel frame with operating mechanism worked from ground level for current rating upto 400 Amps 11000 volts complete including dismantling and taking down existing unserviceable GOD of any description complete all as specified and directed.
Filtration/dehydration of transformer oil through filtration plant to improve the dielectric strength/insulation value of the transformer oil up to 55 KV at 2.5mm gap complete all as specified and directed. Note : (a) The contractor will take shut down orders in working before commencement of the work from Engineer-in-charge. (b) The contractor shall ensure no wastage at transformer oil. (c) The contractor solely responsible for any damage to the transformer/HTOCB during filtration operations. He is responsible for making good any damage to the transformer/HTOCB at his own cost without any extra cost to the department. (d) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration. (e) Contractor will be fully responsible for shift the load of existing transformer to standby transformer before taking down for repair.
Supply and fix disc type insulator porcelain vitreous 145 mm height and 255 mm dia ball and socket type white brown or green with tension clamp for conductor working pressure 11000 volts complete all as specified and directed.
Supply and fix pin type insulator porcelain vitreous white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150 mm height and 150 mm dia for working pressure 11000 volts grade complete all as specified and directed.
Supply, filling and for topping up the transformer with new transformer oil duly filtered with filtration plant complete all as specified and directed. Note: (i) The transformer oil shall be type EHV confirming to IS 3357 of 1983. (ii) Mineral oil grade 'B' shall be used. (iii) The transformer oil should have a high dielectric strength not less than 50KV. (Note: Oil should be brought in 209 ltrs sealed container)
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and directed.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 sq mm complete all as specified and directed.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and directed.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 sq mm complete all as specified and directed.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and directed.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 400 sq mm complete all as specified and directed.
Supply and fix MS Sheet plate 3 mm thick of size 150 x 100 mm fixed on pole/panel with proper size clamps of along with radium alphabet up to 30 Nos complete all as specified and directed.
Taking out/down unserviceable HT under ground cable of size 50 to 95 sq mm of any description from trenches for fixing straight through/end joint of any description and relaying/taking up the same complete all as specified and directed. Note: Excavation, sand cushioning and bricks shall be measured and paid separately under respective items of schedule 'A'.
Taking out/down unserviceable HT under ground cable of size 120 to 185 sq mm of any description from trenches for fixing straight through/end joint of any description and relaying/taking up the same complete all as specified and directed. Note: Excavation, sand cushioning and bricks shall be measured and paid separately under respective items of schedule 'A'.
Supply and fixing LT control copper conductor PVC insulated and PVC sheathed round multi core cable 1100 volts grade including dismantling of existing cable of following cross sectional area sizes :-
Size of cable 2.5 Sq mm 2 Core
Size of cable 2.5 Sq mm 4 Core
Size of Cable 2.5 Sq mm 8 Core
Disconnecting & taking out non functional HT VCB 11 KV 3 phase 1250 Amp 12 KA of make ABB installed at MRS IMA Dehradun, dismantling/opening of the VCB for servicing/ overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/servicing and its testing on full load complete all as specified and directed. Note: (i) The quoted rates includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as ‘supply only’. (ii) The rates quoted by the contractor shall also include the cost of replacement of worn out nuts, bolts, gaskets, A-grade greasing and oiling of moving parts and re fixing the same.
Supply only following spare parts for HT VCB 11KV 3 phase 1250 Amp 12 KA of make ABB, conforming to the respective cat part given as under:- Note: (i) Fixing & testing element of following item is deemed to be included under BOQ item No 23 above. (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item.
Vaccum interrupter 11 KV. of Make ABB Cat Part No. 1VCR004683G0008 or equivalent make from the make specified in PS-II.
Shunt closing coil 110 V DC of Make ABB Cat Part No. 1VCR004291G0005 or equivalent make from the make specified in PS-II.
Shunt opening coil 110 V DC of Make ABB Cat Part No. 1VCR004289G0005 or equivalent make from the make specified in PS-II.
Spring charging geared motor for 220 V 50 Hz AC of Make ABB Cat Part No. 1VCR012079G0004 or equivalent make from the make specified in PS-II.
Enbloc polycarbonate of Make ABB Cat Part No. 1VCR002320G0001 or equivalent make from the make specified in PS-II.
Insulating cover central of Make ABB Cat Part No. 1VCR007464F0001 or equivalent make from the make specified in PS-II.
Insulating cover side of Make ABB Cat Part No. 1VCR007465F0001 or equivalent make from the make specified in PS-II.
Tulip contact assembly 8 finger Make ABB Cat Part No. 500595-802 or equivalent make from the make specified in PS-II.
Auxiliary switch 2O 3C silvered Make ABB Cat Part No. GCE7109399R0122 or equivalent make from the make specified in PS-II.
Auxiliary switch 3O 2C silvered Make ABB Cat Part No. GCE7109399R0121 or equivalent make from the make specified in PS-II.
Unigear 64 pin plug Make ABB Cat Part No. GCE7102436P0100 or equivalent make from the make specified in PS-II. .
EL3 drive complete Make ABB Cat Part No. 510507-805 or equivalent make from the make specified in PS-II.
Common truck 12.12.40 (P210) common truck assembly Make ABB Cat Part No. 1VYN400701-BA or equivalent in CG/Siemens.
Coil support(EL)(1VCF339799R0271) Make ABB Cat Part No. 1VCR002352G0001 or equivalent in CG/Siemens.
Relay of HT VCB 11 KV 1250 Amp having protection of over current trip, earth fault trip, cable arc trip, breaker arc trip, bus bar arc trip, phase unbalance trip, U/V trip, O/V trip, Res O/V trip, TOL trip and TCS unhealthy complete all as specified and directed. Make: ABB Model; REF 615 or equivalent in L&T/Siemens.
Relay of HT VCB 11 KV 1250 Amp having protection of over current trip, earth fault trip, cable arc trip, breaker arc, trip bus bar arc trip, trafo fault trip, TCS unhealthy complete all as specified and directed. Make: ABB Model; REF 615 or equivalent make from the make specified in PS-II.
Testing and calibration of 33 KV VCB outdoor type along with control panel and control wiring, protection system and relays by primary and secondary injection system, battery bank/battery charges/DC system complete all as specified and directed.
Testing and calibration of 11 KV VCB indoor type along with control panel and control wiring, protection system and relays by primary and secondary injection system installed at 33 KV MRS complete all as specified and directed.
Testing and calibration of 33/11 KV, 3.15 MVA outdoor type transformer and control panel -1 No indoor type along with control wiring, protection system complete all as specified and directed.
Testing and calibration of 33/11 KV, 2 MVA outdoor type transformer and control panel -1 No indoor type along with control wiring, protection system complete all as specified and directed.
Dismantling and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of indoor epoxy type 11 KV Transformer having ratio 200/100/5+ 5 Amps having protection core class IP10, burden of 15 VA and breaking cap of 18.4 KA for 1.0 second complete all as specified and directed.
Dismantling and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of indoor epoxy type 11 KV Transformer having ratio 100/50/5+ 5 Amps having protection core class IP10, burden of 15 VA and breaking cap of 18.4 KA for 1.0 second complete all as specified and directed.
Disconnecting and taking out existing unserviceable lighting arrestor any description and in any position and supply and fix new lightening arrester non liner type confirming to IS No 3070 part I complete with all fittings, transmission class discharge capacity 65 KA suitable for 33 KV including making connections complete all as specified and directed.
Supply and fixing digital Volt meter 11 KV, 3 phase range of accuracy 0.5 complete all as specified and directed.
Supply and fixing digital Ampere meter 11 KV 3 phase range of accuracy 0.5 complete all as specified and directed.
Supply and fixing digital LED Pilot lights 110 Volts DC Red /Green/Yellow/Blue complete all as specified and directed.
Supply and fixing digital HRC Fuse with base 2/5/10 Amp complete all as specified and directed.
Repair to HT VCB 33 KV 1250 Amp 25 KA out door of make Crompton Greaves and ABB installed at MRS IMA Dehradun, dismantling/opening of the VCB for servicing/overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/servicing and its testing on full load complete all as specified and directed.
Note: (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. (ii) The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as ‘supply only’. (iii) The rates quoted by the contractor shall also include the cost of replacement of worn out nuts, bolts, gaskets, A-grade greasing and oiling of moving parts and refixing the same.
Supply only following spare parts for HT VCB 33 KV 3 phase 1250 Amp 25 KA of make ABB, conforming to the respective cat part given as under:- Note :- (i) Fixing & testing element of following item is deemed to be included under BOQ item No 58 above. (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item.
Vacuum interrupter 33 KV.
Spring charging geared motor 33 KV.
Closing coil assembly 33 KV.
Tripping coil assembly 33 KV.
Dismantling and taking out existing unserviceable current transformer of any description and in any position and Supply, installation , commissioning and testing of outdoor type 33 KV Current Transformer having ratio 50/25/5+5 Amps having protection core class IP10, burden of 15 VA and breaking cap of 18.4 KA for 1.0 second complete all as specified and directed.
Dismantling and taking out existing unserviceable potential transformer of any description and in any position and Supply, installation, commissioning and testing of 36 KV polycrete outdoor inductive voltage transformer having voltage 33000/√3 winding-I 110/√3 burden 50 accuracy class 0.5 and winding - II 110/√3 burden 50 accuracy class 3 P voltage factor 1.2 cont/1.5-30 Sec insulation level 70/170 kv creep age distance 900 mm complete all as specified and directed.
Material and labour for preparation of old painted surfaces and cooling coils/fins of transformers of capacity 2.0 MVA to 3.15 MVA by removing oil marks using chemical or hot blow lamp. Spray painting to prepared surfaces using synthetic enamel paint of superior quality of colour as approved by GE/AGE E/M as per standard engineering practice with two coats including painting the remaining iron parts i.e. supporting angles, XPM Jali etc and white wash the transformer plate form with two coats. Writing SM No, MES No, Make and capacity with white paint having height not less than 2.5 cm and width not less than 1 cm all as required complete all as specified and directed.
Taking down unserviceable silica gel breather of transformer complete and providing new silica gel breather with all accessories and silica gel refill suitable for transformer of capacity 2.0 to 3.15 MVA complete all as specified and directed.
M&L for graded course aggregate of 63 mm grade nominal size without any vegetation or chemical including leveling /spreading surrounding HT/LT 2/4 pole structure LT/HT panel complete all as specified and directed.
M&L for graded course aggregate of 40 mm grade nominal size without any vegetation or chemical including leveling /spreading surrounding HT/LT 2/4 pole structure LT/HT panel complete all as specified and directed.
Supply, laying, connecting, testing and charging HT cable XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (Heavy duty) 11000 volts grade with stranded aluminum conductor of cross sectional area 240 sqmm 3 core complete all as specified and directed.
Supply, laying, connecting, testing and charging HT cable XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (Heavy duty) 11000 volts grade with stranded aluminum conductor of cross sectional area 185 sqmm 3 core complete all as specified and directed.
Material and labour in replacement of unserviceable danger notice board with pressed vitreous painted plate fabricated out of 1.6 mm thick mild steel sheet vitreous enameled white with letters. figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of size 25X20 cm complete all as specified and directed.
Disconnecting existing power transformer 33KV/11KV of 2.0 MVA capacity including draining out and collecting burnt transformer oil from radiator fins and conservator, dismantling of radiator fins and other accessories etc and keeping aside in safe custody all as specified and directed.
Loading/unloading and transporting defective 2.0 MVA power transformer with the help of crane by using of hydraulic crane and loading on truck from MRS of GE IMA and transport to approved nearby workshop/ factory by road, transporting back to MRS after repairing of transformer and reconnecting incoming and outgoing connections including fixing of radiator fins, conservator, filing of transformer oil and other accessories etc including commissioning and testing all as specified and directed.
Detailed inspection of transformer of cap 2.0 MVA including major repair work in transformer as detailed below : Opening of transformer cover, draining of oil if any, de-tanking core and coil assembly, replacement of damaged items all as per inventory prepared after joint inspection by Engr-in Charge and Contractor, minor repair of any part including core and tank(if required), cleaning washing of dust and dirt etc from all parts including core and tank, cooling tubes of radiators, fitting and fixing of new parts, re-assembling of core and winding after carrying out necessary repair and replacement of defective items including providing all necessary insulation material of appropriate class, drying out in vacuum chamber till specified IR values are obtained, complete insulation varnishing to be done and providing new gasket, nuts , bolts, and checking of leakages if any, rectifying the same by welding etc, replacement of silica gel and reassembling of complete transformer all as directed by Engr-in-Charge , making transformer ready for test and testing all as per IS 2026(Part-I) -1997 para-16/Technical specification.
Supply only new HV coil suitable for 33 KV power transformer complete along with insulation varnishing by vacuum impregnating (if required as per sample) and backing of coil assembly complete all as specified and directed.
All as per item No. 50 above but HV coil suitable for 11 KV power transformer complete all as specified and directed.
Supply only HV bushing with metal part 33 KV for 2.0 MVA transformer complete all as specified and directed.
Supply only 11KV bushing with metal part for 2.0 MVA transformer complete all as specified and directed.
Supply only rubber mat of 1 meter x 2 meter x 19 mm complete all as specified and directed.
Supply only rubber hand glove suitable for 33 KV complete all as specified and directed.
Supply only rubber hand glove suitable for 11 KV complete all as specified and directed.
Earthing complete for machinery equipment installed at power house/sub station with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to GI strip 32mm X 6mm main earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron and protected with 40mm dia light grade GI pipe all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 40mm dia GI light grade earth lead protection pipe etc complete all as specified and directed.
Material & Labour for Earth continuity conductor or main earthing lead GI strip 32x6mm, laid in pipe/fixed on walls or any other position including jointing by tinned GI nuts, bolts and washers in addition to brazing at every joint complete including disconnecting & taking up or down existing unserviceable /de shaped, GI earth strip or taking down conductors of any size and in any position, including making good the disturb surfaces to match with the existing surfaces complete all as specified and directed.
M/s Kamal Traders
M/s Anamika Enterprises
M/s Ram Chander Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .