Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical Disqualfied |
| 3 | Rejected-Technical | Rejected-Technical Disqualfied |
| 4 | Rejected-Technical | Rejected-Technical Disqualfied |
Tender Value
Refer Docs
Closing Date
4 Jan 2021, 3:15 pmClosed
Deputy Vice President (HCD)
LL Lifecare Limited, HCD Projects, HLL Bhavan, No26/4, Tambaram-Velachery Main Road, Pallikaranai, Chennai 600 100, Tamilnadu, India Ph 044 -2981 3732/34
Tender for setting Up of Virology Laboratory (BSL 2) at Mela Hospital, Haridwar in Uttarakhand on TurnkeyBasis
2020_HLL_63640_2
HLL/CMO/HCD/UK-VL/HDR
Open Tender
Construction Works
Turn-key
25 days
Mela Hospital
Please refer Tender documents.
10 documents required · 10 mandatory
₹7,500
Yes
Payable To
Exempted
30 Jan 2021
23 Dec 2020
5 Jan 2021
23 Dec 2020
4 Jan 2021
23 Dec 2020
Amount
Biosafety Cabinet Class II B2
Deep Freezer (-80C)
Deep Freezer (-20C)
Refrigerator (4C)
Automated RNA Isolation platform (96 sample)
Refrigerated Centrifuge
Autoclave Machine
Vortex Mixer
Microspin Centrifuge
Micropipettes (0.1-2.5ul, 0.5-10ul, 2-20ul, 10-100ul, 20-200ul, 30-300ul, 100-1000ul, 500-1000ul)
Multichannel Pipettes
Dry Heat Bath
Real time PCR with computer
DNA/RNA Extractor Kit (1000 tests)
UV Light System
Vibration free table
Computer / Laptop with Printer
Online UPS (40 KVA)
Generator 125 KVA
RT PCR Kit (1000 tests)
Positive Pressure Air Respirator (PAPRS)
Description of Work / Item(s)
Amount
Kits Automated RNA Isolation platform
RT PCR Kit
Description of Work / Item(s)
Amount
Biosafety Cabinet Class II B2
2nd Year
3rd Year
4th Year
5th Year
6th Year
Deep Freezer (-80C)
2nd Year
3rd Year
4th Year
5th Year
6th Year
Deep Freezer (-20C)
2nd Year
3rd Year
4th Year
5th Year
6th Year
Automated RNA Isolation platform (96 sample)
2nd Year
3rd Year
4th Year
5th Year
6th Year
Refrigerated Centrifuge
2nd Year
3rd Year
4th Year
5th Year
6th Year
Autoclave Machine
2nd Year
3rd Year
4th Year
5th Year
6th Year
Microspin Centrifuge
2nd Year
3rd Year
4th Year
5th Year
6th Year
Dry Heat Bath
2nd Year
3rd Year
4th Year
5th Year
6th Year
Real time PCR with computer
2nd Year
3rd Year
4th Year
5th Year
6th Year
Online UPS (40 KVA)
2nd Year
3rd Year
4th Year
5th Year
6th Year
Generator 62.5 KVA
2nd Year
3rd Year
4th Year
5th Year
6th Year
Description of Work / Item(s)
Amount
Civil Work
EARTH WORK
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard rock (requiring blasting)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
DISMANTLING
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm.
Dismantling plastered brickwalls in cement mortar including cleaning, stacking the useful materials as directed by engineer-in-charge and dumping the dismantled debris as indicated at site, levelling, consolidating, all complete as directed and disposing the debris away from site all complete as directed.
CEMENT CONCRETE
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
RCC WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
MASONRY
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
PLASTERING
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) of mix : 1:3(1 cement: 3 fine sand)
ALUMINIUM WORK
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4mm thickness (weight not less than 10 kg/ sqm
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete
Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. 100x70x4 mm (ordinary type)
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 150x10 mm
Providing and fixing panelling or Providing and fixing panelled or Making Shelf, Racks, Tables, etc (Area of opening for panel excluding portion inside grooves or rebates to be measured): Marine Ply wood , 18 mm thick
Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Size 50 mm.
Providing and fixing magnetic catcher of approved quality in cupboard /ward robe shutters, including fixing with necessary screws etc. complete. Triple strip vertical type.
Providing and fixing powder coated telescopic drawer channels(pair) 300 mm long with necessary screws etc. complete as per directions of Engineerin-charge.
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-inchargePowder coated minimum thickness 50 micron aluminium.
FRP DOOR
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
STEEL WORK
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angles 40x40x6 mm for diagonal braces.
PAINTING
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Finishing walls with Acrylic Smooth exterior paint of required shade : Finishing walls with Acrylic Smooth exterior paint of required shade :
WALL TILE
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
CLADDING AND PARTIONS
Supply Installation Testing & Commissioning (SITC) of Cladding panels made up of GI powder coated of 0.8 mm thick sheet on both sides, with 50 mm thick class 'O' PUF of min.38kg/m3 density sandwiched in between. The GI sheet shall have 80 micron thick powder coating by hot dip galvanizing with zinc coating not less than 180gm/sqm both side of the panel. Scope includes bottom runner, inter connecting profiles, fixing arrangements, silicon sealant application and all other accessories required to complete the work as per site requirement. Movable Wall Includes a) Puff Insulation 40kg/m³ b) GI frame work c) Silicon Sealant (Clear/White/Winsil Gray), complete with all necessary hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, drawings and instructions of the Engineer-In charge.
Supply Installation Testing & Commissioning (SITC) of Wall panels made up of GI powder coated of 0.8 mm thick sheet on both sides, with 100/80 mm thick class 'O' PUF of min.38kg/m3 density sandwiched in between. The GI sheet shall have 80 micron thick powder coating by hot dip galvanizing with zinc coating not less than 180gm/sqm both side of the panel. Scope includes bottom runner, inter connecting profiles, fixing arrangements, silicon sealant application and all other accessories required to complete the work as per site requirement. Color: Powder coated, complete with all necessary hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, drawings and instructions of the Engineer-In charge. Self-supporting wall provided in modular units consisting of external skin in PCGI/ PCGI which will be 0.8mm thick ,with protective film to prevent surface damage during shipping and installation. Movable Wall Includes a) Puff Insulation 40kg/m³ b) GI frame work c) Silicon Sealant (Clear/White/Winsil Gray)
Supply, Installation, Testing & Commissioning (SITC) of modular sandwiched doors with both side GI powder coated, GI Sheet construction 0.8mm thickness duly flushed with the walls, with 45mm thick PUF, sandwiched between GI sheets, with drop seal door, including flushed hinges, view panels (800Wx900H), SS304 handle/ push plates and hydraulic door closers. Door complete with all necessary hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, drawings and instructions of the Engineer-Incharge. Doors are available in various sizes as per the requirement of the client. The following accessories are a part of the door: a) Shutter Thickness: 46 mm thick b) Stainless steel hinges c) Stainless Steel 'D' type of handles on pull side d) Stainless steel push plates on push side. e) Dorma make standard arm door closure (TS-68) f) View panel along with self-adhesive tape and silicon sealant g) Both side key operated locking arrangement h) Automatic door bottom seal at the bottom i) Stainless Steel kick plates j) Filler material: Puff Insulation Single leaf door (1200 X 2100)
FALSE CEILING
Supply Installation Testing & Commissioning (SITC) of the Modular False Ceiling System Shall Comprise of Ceiling panels of double skin type, 80 mm thick, sandwiched with self- extinguishing quality PUF of density not less than 38kg/cum. the inner and outer skin shall be of powder coated steel sheet, the thickness of inner skin and outer skin of the panel shall not less than 0.8 mm the powder coated steel sheet shall be hot dip galvanized with zinc coating not less than 180gm/ sqm both side of the GI sheet used. False ceiling panels are designed to fit within each other and suspended by threaded tension bars with adjustable turnbuckles fastened to the overhead support at fixed intervals and have a composite construction of two skins of PCGI / PCGI over an GI frame work with a sealed and insulated interior. Ceiling includes: a) Puff insulation b) Sheet Thickness 0.8mm c) GI frame work d) Silicon sealant(Clear, White, Winsil Gray) From within Only
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board
FLOORING
Providing and fixing 2 mm antistatic seamless conductive Epoxy Flooring (3 Layers + 1 Priming Coat) for Clean room. The floor should be scratch resistant, fire resistant, chemical resistant, non-corrosive, slip resistant, smooth, anti fungi, antimicrobial impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. The floor finish should pass over a concealed cove(curved) former and continue up the wall for 100mm. The floor should be provided flat to within a tolerance of ±3mm over any 3 meter area. Copper grounding strip (0.05 thick, 50 mm width) should be laid flat on the floor in the conductive adhesive and connect to copper wire of grounding. The connection from copper grid should be brought out uniformly at places to form equipotential grid. A self-leveling compound should be laid prior to lying of the floor finish. One earthing lead should be brought out of from every 150 Sq.ft. area and attaching it to main earthing strip/ground. Finished Floor should be highly durable with resistance to shock, scratch proof and indentation. Corners should be uniformly Coved Up to 10 cm height. The conductive material should be uniformly impregnated as grains. The floor should be inert to body fluids, chemicals, detergents and disinfectants and it should not be affected by temperature variation within the OT. Colour should be uniform, pleasant and matching with ambience. The floor should have electrical resistance(Point to ground) within 2.5x10 to 2.5x106 Ohms as per NFPA-99/ DIN 51953/ATMF-150 B1 class of fire resistance. The floor should efficiently discharge electric charges upto 2 KV. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. It should fulfill product requirement s as per EN649. The corner should not be terminated sharply and concealed cove-former (Aluminum) should be used overlap to a height of approx.25mm and sealed perfectly and uniformly. Self-leveling compounds should be used for this purpose.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm
AUTOMATIC HERMETICALLY SEALING DOORS
Providing, Fixing, Installation, and Commissioning of Automatic Hermetically Sealing door 1.2 to 1.8m wide, 2.1 to 2.3m height, having high pressure laminate on both sides that could withstand high abrasion , vision panels (300x500mm) . High grade aluminium extrusion profile to carry any door weight (till size 2400mm in width X 2400mm in height) with deep indentations to ensure perfect hermetic sealing. The door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing to maintain pressure differential. Air tightness 99.99% at a pressure 100KPa (Test certificate for hermetic sealing with door frame should be provided with pre-despatch documents. The finished door on either side of the door should be perfectly level (maximum permissible difference +1mm). The door should provide X-Ray protection as per AERB regulation (Lead equivalent at 100 KV is 0.27mm). Powder coated galvanized sheet 1mm thick over the full length of track with sloping top and closing caps.Door core of 60mm thick built up with 4mm thick HPCL (High Pressure Compact Laminate) skin at both side of the door to provide better strength and rigidity.CFC-free, high density polyurethane puff (density 40 kg/m3), thickness 52mm to provide better insulation.Door core is surrounded by 2.5 mm thick high grade aluminium extrusion profiles with natural anodizing of 15 microns finish.Epoxy Polyester Powder coated as per RAL colours, SS Finish (matt/ mirror finish) The aero- dynamic design of profiles makes the door ROBUST in its segment league.Gaskets Door blade is made with 3-tier specially designed 3 side heavy duty replaceable EPDM gasket against wall frame.Bottom sealing with 2-tier heavy duty EPDM gasket to flush with finished floor.Stainless Steel 304 grade lever handle on both side of the door blade for smooth and easy door opening and closing.High Quality double glazed flush vision window of Wall Frame High grade Aluminium extrusion with natural anodized 15 micron finish wall frame profile. This wall frame profile is 3-sided blind fixed with cladding on wall cut-out section from inside and outside of the room. Including Labour, Transpotation, Conveyance etc. The door interlock and access control system shall be provided with combination of proximity card based, numerical key pad lock based and push button based system. The system shall be complete with access logic controllers, door electromagnets, proximity cards and card reader/s, numerical keypad locks, door release push buttons, emergency door release buttons, PC communicator, control and power wiring and cabling and other required accessories, hardware,and software. The access control system shall be powered through UPS supply for uninterrupted operation even during mains power failure. The door Electromagnetic Lock shall be suitable for installation on doors/frames. The electromagnetic lock and armature shall be constructed and designed to provide trouble free service. MAKE: METAFLEX/REBBONE/ALTOS
FURNITURES
Lockers for Personal belongings (H1800*W900*D450mm,18 cabinets with independent Lock System. Steel structure of Cold-rolled steel plate of 0.8 mm Thick Epoxy Powder Coating Surface)
Contemporary style Work Benches with Steel structure, 'C' & 'H' Frames standard 60 ×40 ×1.5mm square steel tube spraying epoxy powder coating. Body Material 1.2mm galvanized steel, 20mm thickness laboratory grade Black Granite Matt finish worktop . Cabinet for a better apperance and high efficient working station.Cabinet size is 400 ×450 ×600mm & 600 ×450 ×600mm for 1.5 m Standard length, Handle 304# stainless steel. Reagent Shelf Module Aluminum column,12mm tempered glass as the layer. Faucet single taps/two way taps/triple taps for cold water,cold&hot water,pure water taps,sensor tapse. Water proof lab furniture socket
SS 304 grade Revolving Stool, Capacity 100kg, 12" seat size,Height adjustable 450mm to 680mm.
Office Table of 5.5 ft x 2.5 ft approx. 25mm pre-laminated top with 3 drawers on right side and with locker and shelf on other side foot rest and knee cover. Locking System for all the drawer with single key in duplicate Made of CRCA steel with frame 18-gauge square pipes.
Providing and Supplying shoe rack of size 1175W x 1175 H x 375 D, whose work surface is made of 25mm thick. Pre Laminated Particle Board (PLB) OR Engineered Wood All work surface edges are duly sealed with 2mm thick PVC Edge banding. The modesty panel is made of 18mm thick. Pre Laminated Particle Board (PLB) All work surface edges are duly sealed with 2mm thick PVC Edge banding. Powder coat (Epoxy polyester). Brand: Evok OR Equivelent Assembly: Carpenter Assembly Dimensions: 1175W x 1175 H x 375 D Primary Material: Engineered Wood Room
SCRUB STATION
Providing and Fixing 2 bay Surgical Scrub Sink made out of 304 Stainless Steel & seamless welded construction polished to a satin finish which is operated on sensors.Overall Size 1600mmL x 622mmW x 718mmH (63"L x 24.5"W x 28.25"H) Sink Size 1525mmL x 508mmW x 356mmH (60"L x 20"W x 14"H) 2Nos of elbow operated water tap and a Soap Dispensor holder. Welding Joints TIG welding with seamless curves Drain and grid Surface. Including the Cost of 35m UPVC IN & OUT Pipes with individual Effluent decontamination Sysytem.
PASS BOX
Providing and fixing Pass Box of Chamber dimension 610 mm x 610 mm x 610 mm The unit shall be complete with HEPA filters, blower, motor, door electromagnets, door interlock, UV Lamp with timer, necessary wiring, controls and all other accessories. etc. complete. The Pass Box doors shall be interlocked by providing suitable electromagnet, so that both the door cannot be opened simultaneously. The interlock shall provide visual indicator for door open/close conditions. The blower motor of Pass Box shall of suitable rating and shall be dynamically and statistically balanced. Magnehelic differential pressure gauge shall be provided to indicate the pass box chamber pressure. The pass box shall be provided with UV light with ON/OFF switch and shall be interlocked with the pass box doors
PLUMBING
Providing and fixing gun metal gate valve with C.I. wheel of approved quality -25MM nominal bore
Providing and fixing Polypropylene laboratary sink with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 20.9 x 15.3 x 11.1 inches; 2.26 Kg.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. 20 mm nominal outer dia .Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes
Providing and fixing PVC Waste pipe for sink or wash basin including PVC waste fittings complete.:Semi rigid pipe 32mm dia
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
Providing and fixing 25mm Brass Automatic Touchless Sensor tap of Solid Body, Chrome Finish. Infrared Sensor Component, Dual Operation System AC & DC with Deck Mounted Installation.
Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00m spacing and also including cutting of chases and making good the walls including testing of joints complete as per direction of Engineer -in-charge. (The pipe length inserted in the fitting shall not be measured for payment) 22.22 mm Outer dia pipes
Description of Work / Item(s)
Amount
ELECTRICAL WORKS
Point wiring in PVC conduit with modular type switch.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring through PVC conduit
Wiring for circuit/submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Make:Havells/Finolex/V-guard/RR Kabel/Polycab)2X1.5 sq.mm + 1X1.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Make:Havells/Finolex/V-guard/RR Kabel/Polycab)2X2.5 sq.mm + 1 X2.5 sq mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Make:Havells/Finolex/V-guard/RR Kabel/Polycab)2X4 sq.mm + 1X4 sq.mm earth wire
FOR HVAC MAINS:
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 4 X 10 sq.mm + 2 X 6 sq.mm Earth wire\
Telephone wiring in existing conduit:
Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Modular type blanking plate:
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Modular boxes, bases & cover plate:
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.Make:CLIPSAL (Schneider)/Legrand/Havells/Philips.[Make should be Germfree, Antibacteria type.]. 3 module
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.Make:CLIPSAL (Schneider)/Legrand/Havells/Philips.[Make should be Germfree, Antibacteria type] 6 module
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.Make:CLIPSAL (Schneider)/Legrand/Havells/Philips.[Make should be Germfree, Antibacteria type.]. 8 module
Modular type switch/socket:
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Make:CLIPSAL (Schneider)/Legrand/Havells/Philips/Wipro-north-west [Make should be Germfree, Antibacteria type.] 5/6 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Make:CLIPSAL (Schneider)/Legrand/Havells/Philips/Wipro-north-west [Make should be Germfree, Antibacteria type.] 3 pin 5/6 Amp socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Make:CLIPSAL (Schneider)/Legrand/Havells/Philips/Wipro-north-west [Make should be Germfree, Antibacteria type.]. 15/16 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Make:CLIPSAL (Schneider)/Legrand/Havells/Philips/Wipro-north-west [Make should be Germfree, Antibacteria type.]. 6pin 15/16 Amps (universal) socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Make:CLIPSAL (Schneider)/Legrand/Havells/Philips/Wipro-north-west [Make should be Germfree, Antibacteria type.] Telephone socket outlet
S/F PVC conduit:
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make) 20mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make) 25mm
LAN CABLE
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Installation Testing & Commisioning
ITC Fluorescent fitting directly on surface: Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/LED of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
LAYING OF CABLES
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. FROM EB Mains TO VDB1 3.5 X 50 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. FROM VDB TO PBD1,2 3.5 x 25 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. FROM VDB TO LDB1 4 x 16 sq.mm
END TERMINATION
Supply and making end termination with brass compression gland, earth clip and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable fo 1.1KV grade as required. 3.5 X 150 sq.mm
Supply and making end termination with brass compression gland, earth clip and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable fo 1.1KV grade as required. 3.5 X 50 sq.mm
Supply and making end termination with brass compression gland, earth clip and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable fo 1.1KV grade as required. 3.5 X 25 sq.mm
Supply and making end termination with brass compression gland, earth clip and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable fo 1.1KV grade as required. 4 X 16 sq.mm
S/F OF Vertical Distribution Board
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(Make: Legrand/L& T/ABB/Havells/Schneider/IndoAsian/HPL) 8 way (4 + 24), Double door
S/F of TPN MCB DB
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make: Legrand/L& T/ABB/Havells/Schneider/IndoAsian/HPL) 4 way (4 + 12), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make: Legrand/L& T/ABB/Havells/Schneider/IndoAsian/HPL) 8 way (4 + 12), Double door
S/F OF SP MCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/L& T/ABB/Havells/Schneider/IndoAsian/HPL) 6/32 A SP MCB
EARTHING
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc without charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required. (Make: Legrand/L&T/ABB/Havells/Schneider/IndoAsian/HPL)
FIRE ALARM SYSTEM-ADDRESSABLE
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.(Make Honeywell/System Sensor/GST/Siemens or else equivalent or higher version can be used without change in specification and rate)
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.(Make Honeywell/System Sensor/GST/Siemens or else equivalent or higher version can be used without change in specification and rate)
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. (Make Honeywell/System Sensor/GST/Siemens or else equivalent or higher version can be used without change in specification and rate)
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. (Make Honeywell/System Sensor/GST/Siemens or else equivalent or higher version can be used without change in specification and rate)
Supplying, installation, testing & commissioning of fault isolator complete with base as required (Make Honeywell/System Sensor/GST/Siemens or else equivalent or higher version can be used without change in specification and rate)
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.(Make Honeywell/System Sensor/GST/Siemens or else equivalent or higher version can be used without change in specification and rate)
Supplying, installation, testing & commissioning of addressable fire control module complete as required.(Make Honeywell/System Sensor/GST/Siemens or else equivalent or higher version can be used without change in specification and rate)
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.(Make Honeywell/System Sensor/GST/Siemens or else equivalent or higher version can be used without change in specification and rate)
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required
PUBLIC ADDRESS SYSTEM
Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
LIGHT FITTINGS
SITC of modular type 20W LED tube fitting sleek with decorative end cap, powder coated CRCA steel channel complete with all electrical accessories like electronic ballast, lamp holder, 20W LED lamp etc complete as required. (Philips / Wipro /HAVELLS)
CLEAN ROOM LUMINAIRES
Supply,installation, testing and commissioning of peripheral lights 585x 245 mm or 600x600 mm rectangular/square type cool white, pure white LED recess mounted fixture with Integrated Driver & Backlight Technology with a minimum system efficiency of 95 w/Lm, lux level>350, Standard CCT: 3000k* 4000 k & 6500k, high colour rendering CRI>80, IP 55 with high efficiency driver, minimum of 35000 hours working life and surge protection -4kv(light variant as decided by engineer in charge). Fittings shall be sealed type, capable to withshand chemical fumigation. Each module should be tested and QC approved by competent authority and same to be furnished before electrical engineer HLL Life Care Ltd before purchase or else any higher or equivalent versions/specification may be used without change in cost, only at the discretion of HLL/NHM Engineer at site or Electrical Engineer( HLL ) (Make: WIPRO(lc30-551-XXX-57-G1)/Crompton(LCBOR-40-CDL)/or else higher version can be used without change in specification and rate. Philips/GE/Bajaj/Havells)only with the permission of HLL Engineer in charge.).
Supply and installation of 600 mm X 600 mm square type white LED , recess mounted fixture, decorative Soft lite luminaire, powder coated CRCA housing complete with all electrical accessories etc complete with all mounting accessories like chain, anchor fastner etc as required. (Havells VENUS NEO HE 2x2 R18-42WLED840MODUGR<19) or else any higher or equivalent versions/specification may be used only at the discretion of HLL/NHM Engineer at site or Electrical Engineer( HLL ).
SITC of 1x1 Square tyoe Recess Mounted slim circular/Square tye LED panel in white finish with anti-glare diffuser and seperated energy efficient electronic driver with a minimum of following technical specifications - Input voltage AC 220-240 V, 50/60 Hz, Driver Type: Constant Current. Non-Integral, P.F >=.8,High Surge Protection, CRI:Ra>70, LED Life : 30,000 hours, Optics: Poly carbonate Diffuser, Accessories: with Driver and mounting accessories complete as required, any change in the specifications should be made under the consent of Electrical Engineer or Engineer in charge.(Make:Philips/Wipro/GE/Bajaj)
EPABX SYSTEM
Supply, installation, testing and commissioning of EPABX System for upto 2 incoming lines and 8 outgoing lines[including connection for clean room phones] of ISI make complete with its all accessories
Supply and fixing of flush mounted Clean room telehone set for handsfree operation along with its telephone cabling works complete with its all accessories. The phone should have following capabilities 1. smooth front panel sealed with an overlay to keep the phone particulate-free and makes cleaning quick and easy. 2.Auto answer option allows clean room personnel to answer calls without leaving their stations. 3.Oversized buttons allow easy operation for gloved hands. Button function is clearly indicated. 6.Two auto-dial push buttons. 7.on/off push button with keypad for standard telephone operation.
Supply and fixing of Basic landline phone set with jumbo display complete with its all accessories.
FIRE FITTINGS & EXTINGUISHER
Supply, installation, testing and commissioning of 2 loop microprossesor based intelligent and electronically addressable , modular, loop capacity of 159 detectors . Fire alarm control panel with 5.7 inch touch screen LCD display , multiple access levels , 10,000 event history logs in the non volatile memory (EEPROM). The panel should be modular microprocessor based in nature. The panel shall have 240 V AC power supply, automatic battery charger, 24 v , ceiled lead acid maintanance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 30mints during emergency condition. The panel shall be EN 54 /UL certification. (Make Honeywell/System Sensor/GST/Siemens or else equivalent or higher version can be used without change in specification and rate)
Beam Detector: Providing and fixing of Beam detector including mounting base along with interface module to direct connect to loop , having a coverage area with a distance of min 10m and maximum 100m with extra width up to 14 m , operating temperature range of -20C to +55C , Response sensitivity of 40% . (Make Honeywell/System Sensor/GST/Siemens or else equivalent or higher version can be used without change in specification and rate)
Supply & Fixing ISI marked ( IS : 15683 ) Portable Fire Exitnguisher, ABC type,finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of following capacity.-4 KG
Supply and installation of Co2 Fire Extinguisher (Trolley Mount - Wheel Operating) Type 4.5KG with MS clamps etc. for fixing on wall/wooden partition with 01 year warranty. I.S. No. 13849.
PUBLIC ADDRESS SYSTEM
Mixer amplifier: Supply Installation Testing & Commissioning of Class-D PA Amplifier with USB/SD, FM & Bluetooth with remote controller, RMS power: 35W, Impedence: 4Ω, 8Ω, 16Ω , Speaker output: 100V or 70V, Input: 3x Mic in, 2x Line in
Gooseneck Mic: Supply Installation Testing & Commissioning of 18" Condenser type Gooseneck mic with Frequency response: 30Hz-20kHz, Output impedance: 75Ω, Dynamic range: 109 dB, Signal to noise ratio: 65 dB, On/Off switch
LAN ACCESSORIES
Wall Mount Rack - 9U-Wall Mount Racks are made with solid steel structure 9U 19",with minimum dimensions 350x350x550 mm,(H x W x D), in a single section with front lockable glass door and with provision of two side cable entry from top and bottom with proper internal cable management and heat management. Having IP20 level protection.RAL 7035 SHADE , neatly finished etc as required
Supply and fixing RJ45 Keystone IO jack with cover and face plate, including crimbing/Punching of UTP 4 Pair CAT 6E LAN Cables on both ends with RJ45 Connector.
CABLE SUPPLY
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).(Make:Havells/ Glostar/Nicco/Finolex/Polycab) FROM MSB TO SSB 3.5 core 150 sq mm
Supplying the following PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade as per CPWD standards as required. (Make:Havells/ Glostar/Nicco/Finolex/Polycab) 3.5 x 50 sq.mm
Supplying the following PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade as per CPWD standards as required. (Make:Havells/ Glostar/Nicco/Finolex/Polycab) 3.5 x 25 sq.mm
Supplying the following PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade as per CPWD standards as required. (Make:Havells/ Glostar/Nicco/Finolex/Polycab) 3.5 x 16 sq.mm
Supply of following PVC /XLPE insulated armoured cable with copper conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPE 4 x 25 sq.mm
Supply of following PVC /XLPE insulated armoured cable with copper conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPE 4 x 16 sq.mm
S/F of TP MCB
Supplying and fixing 6 amps to 63 amps rating, 415 Volts, "C" series, miniature cirucuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.(Make: Legrand/Havells/HPL/Siemens/ABB/Indo-Asian.) 63A TP MCB
Supplying and fixing 6 amps to 63 amps rating, 415 Volts, "C" series, miniature cirucuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.(Make: Legrand/Havells/HPL/Siemens/ABB/Indo-Asian.) 40A TP MCB
S/F of TPN RCBO
Supplying and fixing following rating, four pole, (three phase and neutral) 415 volts RCBO, having a sensitivity current upto 100/300 milliamperes in the existing MCB PDB complete with connections, testing and commissioning etc. as required.(Make: Legrand/Havells/HPL/Siemens/ABB/Indo-Asian.) 63 A 4P RCBO 100mA
Supplying and fixing following rating, four pole, (three phase and neutral) 415 volts RCBO, having a sensitivity current upto 100/300 milliamperes in the existing MCB PDB complete with connections, testing and commissioning etc. as required.(Make: Legrand/Havells/HPL/Siemens/ABB/Indo-Asian.) 40 A 4P RCBO 100mA
EARTHING WIRE
Supplying and laying 10 SWG Copper wire on, surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/ cable as required.
PANEL BOARD-SSB-EMERGENCY PANEL
All the LT panels shall be with validated design and fully comply with requirements of Type Tested Assemblies (TTA) as per IEC 61439-1&2. All switchgear shall confirm to Ics=100% Icu. The enclosure, busbar, busbar supports etc shall take care of normal stress as well as abnormal electro-mechanical stress due to short circuit conditions. The type tested certificates complying with IEC 61439 shall be submitted. Supplying installation, testing & commissioning of 415 V, 3 ph, 50Hz, 4wire system, sheet steel clad, dust & vermin proof cubical & indoor type floor mounted, free standing extendible type main LT panel with IP-42 Protection, compartmentalized design & fabricated out of 2 mm/1.6mm CRCA Sheet steel complete with Al.Bus bar electrical interlocks as per the various status of all the equipment indicates on the drawing.Providing & fixing of base plate chennel, p/f the following complete with earth bus bar throughout the length of the panel, terminal arrengment for incoming / outgoings cables & also outgoing termination for verious size of cables, the incoming & outgoing feeders shall be accommodated in a modular multi-tier arrenment adiquate size bus duct /cable Alliey, sign writing painting, earthing, numbring, danger plat etc. complet as requir as per specification & drawing .The panel should support provision for MCCB and VFD enclosure with ventilation fan and suitable for AHUs and exhaust units/PDB/LDB & control system.Panel should be CPRI approved manufacturer. INCOMER- 1 nos. 250A, 415V, 4P 35kA MCCB With microprocessor based release having O/L,S/C ,E/F , RPR, O/V, U/V protection & ON/OFF/TRIP Indication with MCB as Bus coupler, 3 nos. Digital type power analyser meters to show (V,A,KWh,KVAh,KW,KVA,KVAR,PF,Hz,harmonic) with cast resin CTs. & communication port, 3 set of LED phase indicating Lamps with MCB protection, 3 nos. trip circuit supervision relays.3 nos.electronic type dual type automatic power factor correction relay, 3 nos TPN surge protection device of class 1&2, 3nos restricted earth fault. BUSBARS-Set of TPN AL bus bar of minimum of 300 A,50/55 kA capacity with heat shrinkable coloured slabs & i/c DMC/SMC Bus bars suports at required intervals complete for cross section, size suports & their spacing etc. for with standing fault level of 50KA for 1 sec.OUTGOING-All MCCBs are to be with rotary operating handle and door interlock, spreader links, terminal shroud kit, phase barrier kit etc.100A,25 kA TPN MCCB with thernal adjustable setting range - 2 no., 63A,25 kA TPN MCCB with thermal adjustable setting range - 5 no., AUTOMATIC POWER FACTOR CONTROL PANEL(EEP) rating as per finalized drawing,IP Rating IP33, IP40, IP44, IP54, IP55, three phase. Rating should be considered for each outgoings. Including and providing, overload indication, over heat sensing, cooling fan, 1 set of LED phase indicators etc complete as required. Providing and Fixing of Electrical ISI Grade Rubber Mat suitable for 440Volts Switchboards. (6' x 3' x 1/4")-4 No.Provide and Fixing of L.T./H.T danger sign boards-1 Each.
Providing and Fixing of Electrical ISI Grade Rubber Mat suitable for 440Volts Switchboards. (6' x 3' x 1/4")
Provide and Fixing of L.T./H.T danger sign boards
PLC CONTROL SYSTEM
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: PLC modules(As per Annexure-1)
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: PLC software.(As per Annexure-2)
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: Control panel (As per Annexure-3)
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: Door access system (As per Annexure-4)
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: CCTV System.Make: LG/Hikvision/CP Plus/Honeywel(As per Annexure-5)
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: Computer (As per Annexure-6)
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: Actuator.(As per Annexure-7)
BAG-IN-BAG-OUT
Supply, installation, testing and commissioning of Bag in Bag out[BIBO] unit complete with its all accessories. The unit should have the following specification listed as per annexure 8.
Supply and fixing of 2 KVA UPS (ONLINE) with battery backup for 15 minutes.( single phase 230V AC+ Neutral + Earth, 50 Hz, p.f of 0.9 output, pure sine wave output, Harmonic distortion: < 2% (linear load) / 5 % nonlinear load, efficiency 90%, Bypass: Static bypass Transfer time.[Make: Tata Emerson/APC/Sukam/V-Guard/Microtek.]
Supply and installation EXHAUST FAN,SHUTTER TYPE white colour, 9" OR 10" star rated as per BEE complete with its all accessories(Make Havells/bajaj/usha/V-guard)
Supply, installation, testing and commissioning of Hot and Cold, 3 star rated (as per BEE) Air Cooled High Wall mounted Inverter type Split Air Conditioner consisting of high wall mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of enegy efficient suitable rotary compressor for operation on single phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation 4m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. Make: Voltas, Toshiba, Blue Star, Siemens, Mitsubuishi, Hitachi or equivalent or as per the approval of Engineer in Charge. Ambient Temperature variation from -10 deg to 60 degree 2 Tr. 3 star rated Air cooled High Wall mounted
SITC OF DIESEL GENERATOR/UPS/INVERTER AND ALLIED WORKS
Supply, installation, testing and commissioning of 40 KVA modular UPS and isolation transformer and tubular battery with 30 min backup. These specification describe requirements for a modular three-phase UPS (UNINTERRUPTIBLE POWER SYSTEM). The design of the UPS shall be doubel/delta conversion online. The scope includes supply, installation, testing and commissioning of the UPS system, tubular battery for 30 min backup at full load, isolation transformer of required capacity at the output, suitable enclosures & racks for UPS, interlink cables, Battery & Transforer, interconnecting cables, circuit breakers (power and control), etc complete for the satisfactory functioning of the UPS system at site. The UPS shall automatically maintain AC power within specified tolerances to the critical load, without interruption (For specified duration as per battery run time), during periods of failure or deterioration of the mains power supply. The UPS shall be equipped with a centrailized mains static bypass switch. The ups shall be suitable for providing power to harmonic rich medical equipment load and computer load.
Supply, Installation and commissioning of continuous duty, True online, Double conversion type, microprocessor based,5 kVA Uninterruptible Power Supply,Voltage : 415 V AC, +/-10%, 3 Phase, 4 - wire, IGBT based, True Sine wave, . 1% (RMS)With Battery Bank DC voltage ripple, Overload Capability 110% for 60 min., 125% for 10 min 150% for 1 min, Built-in Static Bypass and Manual Bypass, Battery : VRLA SMF battery, along with interconnecting cables, rack, etc. with back up time of 30 Minuets, Temperature : Up to 40 degree C, Humidity 90 % RH, Audible Alarms: Normal Mode, Load on Battery, Load on Bypass, System Fault, Mains Failure alarm, Low Battery Alarm,Overload, etc.MCB for protection from Input mains. [Make: Tata Emerson/APC/Sukam/V-Guard/Microtek/Luminous]
SITC of DX type double skinned air handling units, ceiling suspended/ floor mounting type with capacities listed below, complete with suitable DIDW blower (as per approved make), blower section, static presure of 150 mm of water column, built in pre filter, fine filter & hepa filter 99.97% effieciency down to 0.3 microns and controls connected to condensing units, insulated SS drain pan 6 row cooling coil, electric motor , direct driven package with TEFC motor class B insulation, suitable for 3 phase, 415V 50Hz supply, suitable AHU panel & cabling. AHU temp & speed control panel, ARI certified, with 0.70 mm sheet for outer skin and plain GP 0.63 mm sheet for inner skin 47mm thick PUF panel, belt guards, suitable supports for suspending from slab, vibration isolator, strip heater etc. conforming to specifications. Consider ambient temerature range of (-10 degree to max 40 degree)Proper heating coiling should be added.Refer Annexure 9: [Zeco/Flakt/Airvision/VTS/System Air orelse higher version can be used without change in specification and price only with the consent of HLL Engineer in charge.] 8.5 Tr (2400 cfm) with 3 stage Filteration
SITC of DX type double skinned air handling units, ceiling suspended/ floor mounting type with capacities listed below, complete with suitable DIDW blower (as per approved make), blower section, static presure of 150 mm of water column, built in pre filter, fine filter & hepa filter 99.97% effieciency down to 0.3 microns and controls connected to condensing units, insulated SS drain pan 6 row cooling coil, electric motor , direct driven package with TEFC motor class B insulation, suitable for 3 phase, 415V 50Hz supply, suitable AHU panel & cabling. AHU temp & speed control panel, ARI certified, with 0.70 mm sheet for outer skin and plain GP 0.63 mm sheet for inner skin 47mm thick PUF panel, belt guards, suitable supports for suspending from slab, vibration isolator, strip heater etc. conforming to specifications. Consider ambient temerature range of (-10 degree to max 40 degree)Proper heating coiling should be added.Refer Annexure 9: [Zeco/Flakt/Airvision/VTS/System Air orelse higher version can be used without change in specification and price only with the consent of HLL Engineer in charge.] 5.5 Tr (1900 cfm) with 3 stage Filteration
Supply, installation, testing and commissioning (SITC) of 8.5 TR capacity aircooled inveter type Outdoor condensing unit with single/multi scroll compressor as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll compressor, electronic microprocessor pendant controller with digital display, first charge R 407A/R410A refrigerant gas, vibration isolator pads and saftey devices like thermal protector, pressure relief valve, over load relays single phase preventor, high-low pressure cut out, suitable for three phase 440V supply.(Should support ambient temperature of -10 degr to 50 degre)
Supply, installation, testing and commissioning (SITC) of 5.5 TR capacity aircooled inveter type Outdoor condensing unit with single/multi scroll compressor as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll compressor, electronic microprocessor pendant controller with digital display, first charge R 407A/R410A refrigerant gas, vibration isolator pads and saftey devices like thermal protector, pressure relief valve, over load relays single phase preventor, high-low pressure cut out, suitable for three phase 440V supply.(Should support ambient temperature of -10 degr to 50 degre)
Supply, installation, testing and commissioning of suitable sized hard drawn copper refrigerant piping(both suction and liquid piping) including 25mm thick dosed cell elastomeric insulation as per specification for 8 .5 TR & 5.5. Tr machine between indoor & outdoor units as per site conditions complete in all respect.
Supply, installation, testing and commissioning UPVC drain pipe 6kg/sq.cm of suitable dia connecting to the drain pan of the indoor units to nearest drain point, with 12mm thick dosed cell elastomeric insulation as per specification
Canvass connection out of synthetic SRF cloth with zip fastener for measuring temperature at the outlet of AHU.
Supply and fixing of Underdeck insulation with 13 mm thick Fire retardent class nitrile rubber stuck with synthetic adhesive and held in position with SS screw and washer at 600mm centres and cross braced with SS 20SWG wire netting
Supply , installation, Testing and Commissioning of thick extruded ss/aluminum profiles frame and sealed gasketed Laminar Air flow system with plenum for air distribution complete with 6 Nos. HEPA Filters ( usage for seperate roonwise) efficiency 99.99% down to 0.3 microns ) with uv sterilization complete.For Distribution of supply/ return air flow. Designs of class 100. (< = 100 particles/ft3) and bacteriological class B ( = 5 cfu/m3). Hepa should be capable to withstand corrosive agents and gases and have the following items: a.Protective grids : White epoxy painted micro drawn grid b.Separators : Continuous thermo plastic chord c.Sealant : Polyurethane . d.Gasket : One piece polyurethane e.EN 1822 class : H14 f.MPPS average efficiency: > 99.995% g.3 Micron DOP efficiency > 99.999% h.Pressure drop : 600 pa(max) i.Maximum Operating Temp : 60 degree Celsius j.Maximum RH : 90 %. (Submission of test certificate for the filters from original manufacturer is must along with its supply).(Details specifiec in Annexure:10)
Supply, installation and testing of Exhaust fan/blowers with hepa filtered for uni directional air circulation-As per Annexure 11) Exhaust Fan location for BSL-2 : Minimum 25 ft from AHU intake Air velocity at exhaust discharge :As per norms of BSL-2
PRESSURE RELIEF DAMPER
Providing, Fixing, Supply and Installation and Commissioning of proper Pressure Relief Dampers having multi 304 graded stainless steel blades for maintaining the negative pressure inside the lab.
FILTERATION FOR ICU STANDARDS
Supply, installation, testing and balancing of Powder coated/Anodised extruded aluminium construction, inlet air louvers with bird screen, volume damper & filter for fresh air as per specifications and approved drawings
FILTERS: F-7 Filter & Discharge supply section ,Flanged type F-7( 3 micron) Fine filter Flanged type G-4 Pre-filters of capacity-1 no spare.
LOWER SIDE ANCILLARY WORKS;
Supply, installation, balancing and commissioning of ISI-655 site fabricated make 22 swg 19mm insulation of class O, aluminium sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications.
Supply, installation, testing and commissioning of centrifugal stainless steel air curtain with remote and sensor with high quality international standards - CE GS Approved Casing made in Stainless Steel body which is sealed to resist dust going inside, with fire and corrosion resistance, and easy for cleaning and maintenance. Blowers are made of high quality ABS to ensure less noise with toughness intensified High quality motor, low noise, overload protection, and long life-span. Air speed is with High and Low two switch of speeds
Supply, installation, testing and commissioning of 2" Air tight valves for isolating the air circulation from the proposed facility or laboratory room to become isolated from the rest of the HVAC system without affecting other areas
DUCT/DUCT INSULATION / ACOUSTIC INSULATION
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.80 mm sheet
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.19mm
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.25mm
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.
AIR TERMINAL DEVICES
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications, 200mm dia
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Fire Damper
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Actuator
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room-Damper
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room-Actuator
Supply & fixing of powder coated extruded aluminium SUPPLY AIR DIFFUSER with aluminium volume control dampers as per specification with anti smudge ring & removable core.
Supply & fixing of powder coated extruded aluminium RETURN AIR DIFFUSER with louvers without volume control dampers as per specification anti smudge ring & removable core.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .