Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC H K BHATTAR ROAD P O HAZINAGAR NORTH 24 PARGANAS | HAZINAGAR | NORTH 24 PARGANAS | WEST BENGAL | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.2 L+₹259.75 (0.05%)Rejected-AOC 79 7561 J K ROY CHOWDHURY LANE HALISAHAR ARABINDA PALLY P O HALISAHAR NORTH 24 PARGANAS | HALISAHAR | NORTH 24 PARGANAS | WEST BENGAL | L2 | Rejected-AOC L2 | |
| 3 | L3₹5.2 L+₹519.49 (0.10%)Rejected-AOC 96 A KALYANI SIMANTA P O P S KALYANI NADIA PIN 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L3 | Rejected-AOC L3 |
Tender Value
₹5.2 L
EMD Value
₹10,390
Closing Date
17 Jan 2026, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chairman of Halisahar Municipality
Halisahar Municipality PO. Halisahar, PS. Halisahar, North 24 Parganas, Pin-743134
CONSTRUCTION OF TOILET BLOCK AT HUKUMCHAND JUTEMILL NEARBY H/O ABHISHEK SINGH UNDER HALISAHAR MUNICIPALITY. WARD NO 19 AND PART NO 82
2025_MAD_979643_2
WBMAD/ULB/HM/APAS- 11(2025-26)
Open Tender
CIVIL WORKS
Percentage
30 days
HALISAHAR
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹10,390
16 Apr 2026
26 Dec 2025
19 Jan 2026
27 Dec 2025
17 Jan 2026
27 Dec 2025
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (P.No.1, T/2(a) (a) Depth of excavation not exceeding 1,500 mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (P.No.1, T/3(a) (a) With earth obtained from excavation of foundation.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. P.no. 14, T/1)
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion P.no. 34, T/22) (a) 1:3:6 proportion
Brick work with 1st class bricks in cement mortar (6:1) (P.No.15, T/7 a & 8 b) (a) In foundation and Plinth.
(b) In superstructure, ground floor (6:1) Less for door & windows
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). (P.No.47, T/1)
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. P.no. 16, T/16) Less for Windows
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) P.no. 42, T/36 a) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In- Charge
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (a) Pakur/Chandil variety. (P.No.26 T/10(i))
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (P-43, T/40)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary .[Excluding cost of chipping over concrete surface] A) In Ground floor (P-189 T-1,) (A) With 1:4 cement mortar (c) 10 mm thick plaster (celing
(B )With 1:6 cement mortar (c) 20 mm thick plaster (Inside plaster) Less for door & windows
(C )With 1:6 cement mortar (C) 15 mm thick plaster (outside plaster) Less for door & windows
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (P-107, T/20) (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (P.No.104, T/13(i) ) (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. (P.No.106, T/18) In ground floor.
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (P.No.205, T/1) (ii) 4 mm thick
Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge. In ground floor. (P-125, T/15)
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (P-64, T/35) (A) Floor With polymerised Adhesive and Epoxy grout pointing including spacer-2 mm (when tiles are laid over existing hard ready surface) (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative
(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative Less for door & windows
White washing including cleaning and smoothening surface thoroughly (b) Two coats (to be done on specific instruction) (P-194, T/1(b)) Plaster (A+B+ C)) Less wall tiles area
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (P-200, T/1 a)
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (P-200, T/2 a, iv) (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, alamoid /Bitumen /M-Seal etc) complete. (P-212, T/21 a, ii) A) UPVC Pipes: (ii) 110 mm. Dia.
B) UPVC Fittings: a) Plain Tee (ii) 110 mm. Dia.
d) Shoe (ii) 110 mm. Dia.
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (P-79, T/2) Plumbing & Sanitary Schedule 2017 (a) With 'P' trap
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. (P-80, T/6 (ii)) Plumbing & Sanitary Schedule 2017
Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). (P-80, T/7) Plumbing & Sanitary Schedule 2017
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. (P-81, T/11) Plumbing & Sanitary Schedule 2017 i) Polythene Flush Pipe
Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (P-81, T/12 (a)) Plumbing & Sanitary Schedule 2017 (a) C.P. urinal flush pipe fittings range of one
Supplying, fitting and fixing soap holder. (P-82, T/18 (b)) Plumbing & Sanitary Schedule 2017 (b) Fibre glass
Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets. (P-41, T/1 (ii)) Plumbing & Sanitary Schedule 2017
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (P-43, T/9 9 (iii)) Plumbing & Sanitary Schedule 2017
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (P-43, T/10 (iv)) Plumbing & Sanitary Schedule 2017 (iv) 1050 mm long
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. (P-36, T/2) Plumbing & Sanitary Schedule 2017
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (P-37, T/6 (b)) Plumbing & Sanitary Schedule 2017 (b) 1000 litre capacity
Supplying, fitting & fixing H.C.I. bend with door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (P-61, T/17) Plumbing & Sanitary Schedule 2017 (a) With valamoid joints including sealing the top with cement mortar (4:1) (ii) 100 mm dia.
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (P-12, T/19 (I)) Plumbing & Sanitary Schedule 2017 (a) For Exposed Work PVC Pipes (i) 25 mm dia
(ii) 20 mm dia
(iii) 15 mm dia
Supplying, fitting and fixing bib cock or stop cock. (P-6, T/7) Plumbing & Sanitary Schedule 2017 (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). 15 mm
(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. (P-87, T/1) Plumbing & Sanitary Schedule 2017 i) With Pakur variety. (SAIL/TATA/RINL)
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. (P-89, T/3 (iii) (a)) Plumbing & Sanitary Schedule 2017 (iv) For 30 users A) With Pakur variety. (SAIL/TATA/RINL)
Add GST @ 18%
Add Cess 1%
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.37 MB
Tendernotice_2.pdf
PDF • 1.23 MB
BOQ_2388137.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .