Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | Admitted-Finance |
| 3 | Admitted-Finance 472 C 1 TOCOL MACHINE TOOLS PRIVATE LIMITED 13TH CROSS 4TH PHASE PEENYA INDUSTRIAL AREA BANGALORE KARNATAKA 560058 | BENGALURU URBAN | KARNATAKA | 560058 | Admitted-Finance |
| 4 | Admitted-Finance 31 NEELGIRI IND ESTATE T J ROAD SEWRI W MUMBAI MAHARASHTRA 400015 | MUMBAI | MAHARASHTRA | 400015 | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical AS PER RFP |
Tender Value
Refer Docs
Closing Date
26 Apr 2021, 10:00 amClosed
DGMCOM
DGMCOM, INCOD, NAVAL DOCKYARD, SBS ROAD , MUMBAI 400023
OFFLOADING CASE FOR REPAIR / REFURBISHMENT OF VARIOUS CONTROL SYSTEM FITTED ONBOARD INS VIKRAMADITY
2021_NAVY_433791_1
DYT/ECI/20-21/106A/ PL-IN/VKD-CONTROL SYSTEMS/391
Open Tender
Marine Services
Item Rate
300 days
NAVAL DOCKYARD MUMBAI
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
NAVAL DOCKYARD MUMBAI
3 Jun 2021
31 Mar 2021
27 Apr 2021
31 Mar 2021
26 Apr 2021
9 Apr 2021
9 Apr 2021
Amount
Service - Removal, Overhauling, Servicing, Calibration and Fitment of Pressure sensor relay./ pressure switch Functional check and STW to be done onboard ship. (07 in nos for each FCBT Control System).
Service - Removal, Overhauling, Servicing and Fitment of Electro hydraulic four way manipulator. Functional check and STW to be done onboard ship. (04 in nos for each FCBT Control System)
Service - Removal, Overhauling, Servicing, Calibration and Fitment of Differential Pressure Regulator. Functional check and STW to be done onboard ship - FCBT Control System.
Service - Removal, Overhauling, Servicing and Fitment of Lock in relay. Functional check and STW to be done onboard ship - FCBT Control System
Service - Removal, Overhauling, Servicing and Fitment of booster relay. Functional check and STW to be done onboard ship - FCBT Control System
Service - Removal, Overhauling, Servicing and Fitment off quick closing valve. Functional check and STW to be done onboard ship - FCBT Control System
Service - Removal, Overhauling, Servicing and Fitment of Hydraulic suction/vacuum equalizing valve. Functional check and STW to be done onboard ship - FCBT Control System
Service - Removal, Overhauling, Servicing and Fitment of Impeller of feed pump. Functional check and STW to be done onboard ship - FCBT Control System
Service - Removal, Overhauling, Servicing and Fitment of regulating valves. Functional check and STW to be done onboard ship - FCBT Control System
Material - Renew FCBT LCP Local Control Panel – (Size 1X1X1 Feet) with Steel Body (Rust Proof)
Service - Fitment of FCBT LCP Local Control Panel – (Size 1X1X1 Feet) with Steel Body (Rust Proof), Scope of work include (a) Degutting of Panel / Cable / Conduct Pipes. (b) Disconnect all connections, marking and insulate all opened connection. (c) Fitment of new LCP. Connection of all electrical connections. (d) Panel internal Wiring / Connector Change and Lugging. Also Earthing wire, Panel connector, Lamp, Switches of Panel, Lamp indicator. (e) Proving the system and STW- FCBT Control System
Material - Renewal of Cable / Local Control Panel to Control Box Cabling / Connectorisation 19 Core X 1.5 Sq mm - 400 Mtr. (50 Meter each per FCBT) Connectorisation / Lugging at both end. (Qty in Mtr) - FCBT Control System
Service - Renewal of Cable / Local Control Panel to Control Box Cabling / Connectorisation 19 Core X 1.5 Sq mm - 400 Mtr. (50 Meter each per FCBT) Connectorisation / Lugging at both end.(Qty in Meter)- FCBT Control System
Material - Renewal of Cable of Pressure Switch to Control Box approx 3200 Mtr of 3 Core X 1.5 sqmm. (400 Meter each per FCBT) Connectorisation / Lugging at both end. (Qty in Meter)- FCBT Control System
Service - Laying of Cable of Pressure Switch to Control Box approx 3200 Mtr of 3 Core X 1.5 sqmm. (400 Meter each per FCBT) Connectorisation / Lugging at both end.(Qty in Meter)- FCBT Control System
Material - Renew Cable & Connectorisation / Cable gliding / securing from Manipulator to Control Box for 16 in No Manipulator. 4 Core X 1.00 sqmm and 800 Mtr. (50 Meter Each) (Qty in Meter) - FCBT Control System
Service - Laying of Cable & Connectorisation / Cable gliding / securing from Manipulator to Control Box for 16 in No Manipulator. 4 Core X 1.00 sqmm and 800 Mtr. (50 Meter Each)(Qty in Meter) - FCBT Control System
Material - Renewal of Metal conduit pipe of 1’’, Renewal on all FCBT approx 150 Mtr & securing of Aluminium Alloy (Rust Proof) conduit pipe. For all 08 FCBT (Qty in Meter)- FCBT Control System
Service - Laying of Metal conduit pipe of 1’’ , Renewal on all FCBT approx 150 Mtr & bending as per space / securing of Aluminium Alloy (Rust Proof) conduit pipe. For all 08 FCBT (Qty in Meter)- FCBT Control System
Material - Cable Tray Approx 1000 Mtr of 6''/ 150 MM for cable securing. (Qty in Meter) - FCBT Control System
Service - Laying of Cable Tray Approx 1000 Mtr of 6''/ 150 MM including cable securing, clamping of trays. (Qty in Meter) - FCBT Control System
Service - Removal, Overhauling, Servicing and fitment of QCV. Functional check and STW to be done onboard ship. Check and purge associated pipes. Change ‘O’ Rings, Adapters, Connectors. Pressure test / Leak proof system - FCBT1
Material - Renewal of 1'' SS pipe, Change ‘O’ Rings, Adapters, Connectors. (Length in meters) - FCBT 2
Service - Check and purge associated pipes. Change ‘O’ Rings, Adapters, Connectors. Pressure test / Leak proof system. Rectify defect and complete STW onboard Ship - FCBT 2
Service - Check the protection system for operation - Over speed trip. Repair and calibrate KD140 indicator with Sensor. - FCBT
Material - Replace 03 Core/1 Sq mm trip switch screen cable (Qty in Meter)- FCBT
Service - Laying of 03 Core/1 Sq mm trip switch screen cable (Qty in Meter) - FCBT
Service - Rectify defect for Low lubrication oil pressure. -FCBT
Service - Removal, Overhauling, Servicing and fitment of servomotor for all quick/automatic operating valves with actuators/ servomotors, Sentinel valve. Functional check and STW to be done onboard ship. - FCBT
Service - Check and prove setting of protection system. Rectify defect - FCBT
Service - Check seals of servomotor for leaks. The system to be made leak proof. - FCBT
Service - Removal, Overhauling, Servicing and fitment of Servomotor for QCV. Functional check and STW to be done onboard ship - FCBT Pumps
Service - Removal, Overhauling, Servicing and fitment of Servomotor for regulating valve. Functional check and STW to be done onboard ship - FCBT Pumps
Service - Removal, Overhauling, Servicing and fitment of Hydraulic suction/ vacuum equalising valve. Functional check and STW to be done onboard ship - FCBT Pumps
Service - Removal, Overhauling, Servicing and fitmentof Four way manipulator. Functional check and STW to be done onboard ship - FCBT Pumps
Service - Removal, Overhauling, Servicing and fitmentof Drop regulator. Functional check and STW to be done onboard ship - FCBT Pumps
Service - Removal, Overhauling, Servicing and fitment of Drop regulator for standby FCBT. Functional check and STW to be done onboard ship - FCBT Pumps
Service - Removal, Overhauling, Servicing and fitment of Booster relay. Functional check and STW to be done onboard ship - FCBT Pumps
Service - Overhauling and proving of the regulation control and protection system of TD circulator - TD Circulating Pump.
Material - Change ‘O’ Rings, Adapters, Connectors. Leak proof system. SoW includes replacement of Roller, ratchet bush, lever assembly, spring, bush, friction bush, casing, deflector, sleeves, special pin, indicators, sleeve assembly, rod, lever assembly, four part ring, two part ring, washers, two part bush, screw rod, position pins, paper pin, O Rings, Gaskets, Nut Bolts - TD Circulating Pump.
Service - Removal, Overhauling, Servicing and fitment of QCV. Functional check and STW to be done onboard ship. Check and purge associated pipes. Change ‘O’ Rings, Adapters, Connectors. Leak proof system / Pressure Test. SoW includes replacement of Roller, ratchet bush, lever assembly, spring, bush, friction bush, casing, deflector, sleeves, special pin, indicators, sleeve assembly, rod, lever assembly, four part ring, two part ring, washers, two part bush, screw rod, position pins, paper pin, O Rings, Gaskets, Nut Bolts - TD Circulating Pump.
Material - Overhauling and Servicing of Servo Drive. SoW includes replacement of O Rings, Gaskets, Nut Bolts, Springs, Guide Bush, Roller assembly, sleeve, needle, disc, pusher, stop, adjusting bush, rod, outer ring, inner ring, piston, valve, lever assembly - TD Circulating Pump.
Service - Overhauling and Servicing of Servo Drive. Functional check and STW to be done onboard ship. SoW includes replacement of O Rings, Gaskets, Nut Bolts, Springs, Guide Bush, Roller assembly, sleeve, needle, disc, pusher, stop, adjusting bush, rod, outer ring, inner ring, piston, valve, lever assembly - TD Circulating Pump.
Material - Replacement of Gaskets, Nut Bolts, Springs, Guide Bush, special nut, spring cap - TD Circulating Pump.
Service - Overhauling and Servicing of Limit RPM Regulator. Regulator to be cleaned, dis-assembled, overhaul, assembled and adjusted. Functional check and STW to be done onboard ship. SoW includes replacement of Gaskets, Nut Bolts, Springs, Guide Bush, special nut, spring cap - TD Circulating Pump.
Material - Replacement of dog catch axle, dog catch, clevis, roller, striker, spring, bush, stop, shim and spiral spring - TD Circulating Pump.
Service - Overhauling and Servicing of Limit Regulator Lever. It needs to be cleaned, dis-assembled, overhaul, assembled and adjusted. Functional check and STW to be done onboard ship. SoW includes replacement of dog catch axle, dog catch, clevis, roller, striker, spring, bush, stop, shim and spiral spring - TD Circulating Pump.
Service - Removal, Overhauling, Servicing and fitment of Throttle Slide Valve. Functional check and STW to be done onboard ship - TD Circulating Pump.
Service - Check the regulation and protection assemblies for serviceability and adjustment - TD Circulating Pump.
Service - Calibration of Sensor , Tachometer matching Module & Indicator - TD Circulating Pump.
Material - Renewal of defective screened cable, lugging, gliding. RPM Sensor (Pick type ) to Matching module. 3 Core X 0.5 sqmm. (Qty in Meter) - TD Circulating Pump.
Service - Laying / securing of defective screened cable, lugging, gliding. RPM Sensor (Pick type ) to Matching module. 3 Core X 0.5 sqmm.(Qty in Meter) - TD Circulating Pump.
Material - Renewal of defective screened cable, lugging, gliding. Matching Module to gauge 300 Mtr 3 X 0.5 sqmm. (Qty in Meter) - TD Circulating Pump.
Service - Laying/securing of defective screened cable, lugging, gliding. Matching Module to gauge 300 Mtr 3 X 0.5 sqmm.(Qty in Meter) - TD Circulating Pump.
Material - Renewal of defective screened cable, lugging, gliding. Matching Module to Back rectifier of 3 X 0.5 sqmm.(Qty in Meter) - TD Circulating Pump.
Service - Laying/ securing of defective screened cable, lugging, gliding. Matching Module to Back rectifier of 3 X 0.5 sqmm.(Qty in Meter) - TD Circulating Pump.
Material - Renewal of defective connectors approx of various size Pins (4 Pin, 2 Pin, 7 Pin etc), soldering, securing, tallies. Soldering of connectors. (Qty in Each) - TD Circulating Pump.
Service - Connectorisation of defective connectors approx of various size Pins (4 Pin, 2 Pin, 7 Pin etc), soldering, securing, tallies. Soldering of connectors.(Qty in Each) - TD Circulating Pump.
Service - Repairs of Tachogenerator, maching module and indicator of TD Circulator (04 in nos for each TD Circulator)
Service - Removal, Overhauling, Servicing and fitment of spool valve. Functional check and STW to be done onboard ship of TD Circulator
Service - Calibration of DP Level Transmitters. Function check and STW to be done onboard ship of various systems
Service -Tuning of RPM setter, Function check and STW to be done onboard ship
Service - Calibration of Boiler water level sensor, Function check and STW to be done onboard ship
Service - RCP system of TDFL responding sluggish, to be overhauled. Defect to be rectified and Complete systems to be proved with functional checks and STW onboard ship - TDFL 3
Service - Turbine top and bottom bearing to be inspected and checked for clearances - TDFL 3
Service - Turbine rotor to be inspected for trueness shaft balancing and alignment also to be checked - TDFL 3
Material - Labyrinth glands to be renewed - TDFL 3
Service - Regulation Control Protection block to be overhauled and system to be proven for correct functioning - TDFL 3
Service - The turbine casing to be checked for serviceability and renewed if required - TDFL 3
Service - RECP system of TDFL responding sluggish, to be overhauled. Defect to be rectified and Complete systems to be proved with functional checks and STW onboard ship - TDFL
Service - Turbine top and bottom bearing to be inspected and checked for clearances - TDFL
Service - Turbine rotor to be inspected for trueness shaft balancing and alignment also to be checked - TDFL
Material - Labyrinth glands to be renewed - TDFL
Service - Regulation Control protection clock to be overhauled and system to be proven for correct functioning. - TDFL
Service - The turbine casing to be checked for serviceability and renewed if required - TDFL
Service - Check serviceability and undertake adjustment of regulation and protection assemblies - TDFL
Service - TDFL To be overhauled and serviceability checks to be carried out. Function check and STW to be done onboard ship
Service- Repair and Calibration of Tachogenerator, matching module and indicators of TDFL (04 in nos for each TDFL)
Service - Removal, Refurbishment,Calibration and Fitment of TDFL: 0-15000 RPM
Service - Removal, Refurbishment,Calibration and Fitment of tachogenerator range: 0-2000 RPM - Turbo Generator
Service - Removal, Refurbishment,Calibration and Fitment of Pump pressure gauges. Range: 0-600kpa in Terek Panel of TG Control Panel
Service - Removal, Refurbishment,Calibration and Fitment of Vacuum gauges, range – 100kpa -300 kpa in Terek Panel of TG Control Panel
Service - Removal, Refurbishment,Calibration and Fitment of Steam pressure gauges. range 0-10 kpa of Terek Panel
Service - Removal, Refurbishment,Calibration and Fitment of Lub oil Pump pressure gauges in Terek Panel of TG Control Panel. Range: 0-600kpa.
Service - Removal, Refurbishment,Calibration and Fitment of RPM indicator gauge 0-1800 rpm in Terek Panel of TG Control Panel. Qty-6 (calibration with sensor/ tacho generator)
Service - Removal, Refurbishment,Calibration and Fitment of Steam temperature indicator, range 0-6100 Celsius in Terek Panel of TG Control Panel(calibration with sensor/ tacho generator)
Service - Removal, Refurbishment,Calibration and Fitment of Bearing temperature gauge view erratic indication in local gauges, range 0-100 Celsius in Terek Panel of TG Control Panel(calibration with sensor/ tacho generator)
Service - Removal, Refurbishment,Calibration and Fitment of Lub oil pressure 0-100 kpa in Terek Panel of TG Control Panel. Qty-06
Service - Removal, Refurbishment,Calibration and Fitment of Governing oil Switch 100kpa-300 kpa in Terek Panel of TG Control Panel. Qty- 06
Service - Removal, Refurbishment,Calibration and Fitment of Vacuum Switch 100kpa-300 kpa in Terek Panel of TG Control Panel. Qty- 06
Service - Removal, Refurbishment,Calibration and Fitment of Pump pressure switch in Terek Panel of TG Control Panel. Range: 0-600kpa. Qty- 06
Service - Removal, Refurbishment,Calibration and Fitment of Sat steam pressure switch range 0-10 Mpa in Terek Panel of TG Control Panel. Qty- 06
Service - Removal, Refurbishment,Calibration and Fitment of Aux - steam pressure switch range 0-10 Mpa in Terek Panel of TG Control Panel. Qty- 06
Service - Low vacuum indication in Terek Panel of TG Control Panel (Defect Identification and Defect rectification)
Service - Low lub oil pressure in Terek Panel of TG Control Panel(Defect Identification and Defect rectification)
Service - Oil temperature increasing in Terek Panel of TG Control Panel(Defect Identification and Defect rectification)
Service - Oil temperature decreasing in Terek Panel of TG Control Panel(Defect Identification and Defect rectification)
Service - over speed indication in Terek Panel of TG Control Panel(Defect Identification and Defect rectification)
Service - Bearing temperature in Terek Panel of TG Control Panel(Defect Identification and Defect rectification)
Service - Sea water pressure drop indication in Terek Panel of TG Control Panel(Defect Identification and Defect rectification)
Service - Emergency oil pump indication in Terek Panel of TG Control Panel(Defect Identification and Defect rectification)
Service - QCV indication in Terek Panel of TG Control Panel(Defect Identification and Defect rectification)
Service - Check Gate Valve operation from push button and check of valve position lamp for all tanks of Boiler Fuel System Control and Indication System (PUNS)
Material - Renewal of Push Button on Control Panel and check actual valve position for Gate Valve 22, 53 and 57 of Boiler Fuel System Control and Indication System (PUNS)
Service - Fitment of Push Button and STW on Control Panel and check actual valve position for Gate Valve 22, 53 and 57 of Boiler Fuel System Control and Indication System (PUNS)
Service - Incorrect position of switch showing for gate valve of aft receiver of boiler fuel for Gate valve no. 53 and 57 of Boiler Fuel System Control and Indication System (PUNS). Rectify defect.
Material - Change of CKΠУM Д3a and re-soldering of cable connectors for gate valve 5 of Boiler Fuel System Control and Indication System (PUNS)
Service - Change of CKΠУM Д3a and re-soldering of cable connectors for gate valve 6 of Boiler Fuel System Control and Indication System (PUNS)
Service - CKΠУM Д3a is to be tuned for Gate Valve no. 12 of Boiler Fuel System Control and Indication System (PUNS)
Material - Change of CKΠУM Д3a, re-soldering of cable connectors of gate valve no. 15. Rectify defects.
Service - Change of CKΠУM Д3a, re-soldering of cable connectors of gate valve no. 15 of Boiler Fuel System Control and Indication System (PUNS). Rectify defects.
Service - Signal is duplicated from ΠУMHC2 and ΠУMHC2 has faulty power supply line for gate valve 57 of Boiler Fuel System Control and Indication System (PUNS). Faulty signal on control panel. Rectify defects and Calibrate CKΠУM Д3a,
Service - Faulty power supply line or sensor for Tank No. H-36, H-38, H-39, H-40, H-43, H-53, PH-5, PH-6, PH-7 of Boiler Fuel System Control and Indication System (PUNS). Rectify defects and STW
Material - Renewal of Push Button on Control Panel for Gate Valve 22 of Boiler Fuel System Control and Indication System (PUNS).
Service - Fitment and STW of Push Button on Control Panel for Gate Valve 22 of Boiler Fuel System Control and Indication System (PUNS).
Material - Change of CKΠУM Д3a and re-soldering of cable connectors for gate valve 39 Replace CKΠУM Д3a for gate valve 38,40,41,42,53 of Boiler Fuel System Control and Indication System (PUNS)
Material - Renewal of CKΠУM Д3a and re-soldering of cable connectors for gate valve 39 Replace CKΠУM Д3a for gate valve 38,40,41,42,54 of Boiler Fuel System Control and Indication System (PUNS)
Material - Renewal of cables for Gate Valve 57,72,73 of Boiler Fuel System Control and Indication System (PUNS). (3 Core signal cable, screened) (Qty in Meter)
Service - Laying and securing of cables for Gate Valve 57,72,73 of Boiler Fuel System Control and Indication System (PUNS). (3 Core signal cable, screened) (Qty in Meter)
Material - Flexible conduits for laying of Boiler Fuel System Control and Indication System (PUNS)(3 Core signal cable, screened) (Qty in Meter)
Service - Flexible conduits for laying of Boiler Fuel System Control and Indication System (PUNS) (3 Core signal cable, screened) (Qty in Meter)
Material - Replace CKΠУM Д3a for Gate Valve 76 connector for Gate Valve 76 of Boiler Fuel System Control and Indication System (PUNS).
Service - Connectorisation of CKΠУM Д3a for Gate Valve 76 and re-solder connector for Gate Valve 76 of Boiler Fuel System Control and Indication System (PUNS)
Service - Rectify defect for Gate Valve No. 77 of Boiler Fuel System Control and Indication System (PUNS) Faulty indication
Material - Replace lamp with caps of Boiler Fuel System Control and Indication System (PUNS) including fitment of lamps with caps
Material - Renewal of fire retardent 02 Core screen cable (From sensors to JB and JB to RPCC Panel (Length in Meter) including gland packing, end connections, lugging, soldering, earthing
Service - Laying/ securing of fire retardent 03 Core screen cable (From sensors to JB and JB to RPCC Panel (Length in Meter) including gland packing, end connections, lugging, soldering, earthing
Service - Calibration of salinometer of MTXM (TDAC) System
Material - Renewal of Pressure Cut Outs (3KG per centimeter square) of MTXM (TDAC) System including fitment and STW onboard
Material - Renewal of Pressure Cut Outs (1.65 to 1.85 KG per centimeter square) of MTXM (TDAC) System including fitment and STW onboard
Material - Renewal of Temperature Cut Outs (35 deg centigrade) of MTXM (TDAC) System including fitment and STW onboard
Material - Renewal of Temperature Cut Outs (55 deg centigrade) of MTXM (TDAC) System including fitment and STW onboard
Material - Renewal of Temperature Cut Outs (75 deg centigrade) of MTXM (TDAC) System including fitment and STW onboard
Material - Renewal of Temperature Cut Outs (80 deg centigrade) of MTXM (TDAC) System including fitment and STW onboard
Material - Renewal of cable tray including clamping, securing of MTXM (TDAC) System including fitment and STW onboard
Material - Renewal of conduit including clamping, securing of MTXM (TDAC) System including fitment and STW onboard
Service - Laying of cable tray including clamping, securing of MTXM (TDAC) System (Qty in Meter)
Service - Laying of conduit including clamping, securing of MTXM (TDAC) System (Qty in Meter)
Service- Function check, STW and proving of RPCC Control Circuit Panel of MTXM (TDAC) Sytem to be done onboard ship
Service - Defect Identification and Defect Rectification of Working Water System of FCBT Controls
Service - Defect Identification and Defect Rectification of Working Water System of TD Lubricant Pump Controls
Service - Defect Identification and Defect Rectification of Working Water System of TD Circulator Controls
Service - Defect Identification and Defect Rectification of Working Water System of MTXM (TDAC) plants
Service - Degutting/regutting, cleaning / purging of all control pipes FCBT System and connected equipments (including tagging for indentifcation)
Service - Degutting/regutting, cleaning / purging of all control pipes TD Circulator Controls and connected equipments (including tagging for indentifcation)
Service - Degutting/regutting, cleaning / purging of all control pipes of TD Lubricant Pump Controls and connected equipments (including tagging for indentifcation)
Service- NR Maintenance routines, defect rectification, function checks and STW of Terek Panel of TG Controls
Service- NR Maintenance routines, defect rectification, function checks and STW of TD Lubricant Pump Controls
Service- NR Maintenance routines, defect rectification, function checks and STW of TD Circulator Controls
Service- NR Maintenance routines, defect rectification, function checks and STW of FCBT Controls
Service- NR Maintenance routines, defect rectification, function checks and STW of (PUNS) Boiler Fuel System Control and Indication System. Qty in Set
Service- NR Maintenance routines, defect rectification, function checks and STW of MTXM (TDAC) plants.
Service -HATs and SATs for all the serials of BOQ (Qty in Mandays for service engineers)
YEOMAN MARINE SERVICES PVT. LTD.
TOCOL MACHINE TOOLS PVT LTD
SMEC Automation Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .