Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 969 EWS
GE 969 EWS
PROVN OF ELEVATED GUARD POST AT BARAMULLA , SPL REPAIR TO TOILET OF BLDG NO P-506,T-63,T-64 AND T-65 AT BARAMULLA AND PROVN OF DRAINS INCLUDIND CONNECTED WORKS AT NAUGAM UNDER GE 969 EWS.
2021_MES_447927_2
CANO 969/WS- /2021-22
Open Tender
Civil Works
Item Rate
270 days
Baramulla
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹58,000
Yes
11 Mar 2022
17 Jan 2022
8 Feb 2022
17 Jan 2022
5 Feb 2022
24 Jan 2022
60 days
Amount
Surface excavation n exc 30 cm deep and averging 15 cm deep and getting out in soft loose soil Complete all as specified and directed by Eng-In-Charge.
Excavation over areas n exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sq m on plan aqnd n exc 1.5m in depth and getting out in soft/loose soil Complete all as specified and directed by Eng-In-Charge.
Excavation over area exc 1.5m and n exc 3 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sq m on plan aqnd n exc 1.5m in depth and getting out in soft/loose soil Complete all as specified and directed by Eng-In-Charge.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes,cables etc n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil Complete all as specified and directed by Eng-In-Charge.
Dismantling floor hearth or wall tiling including cement mortor bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises Complete all as specified and directed by Eng-In-Charge.
Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15cm thickness (below or ground level) Complete all as specified and directed by Eng-In-Charge.
Taking down chowkhats or frames exc 1.5 Sqm but n.exc 4.00sqm each with shutters (without taking off shutters from the frame) Complete all as specified and directed by Eng-In-Charge.
Taking down shutter exc 1.00sqm and n.exc 2.00sqm each & refixing in the same opening after resecuring or easing and adjusting shutters of any description Complete all as specified and directed by Eng-In-Charge.
Dismantling of plain or corrugated steel sheeting , any gauge and thickness in roof covering including Nainital or similar pattern roof covering Complete all as specified and directed by Eng-In-Charge.
Taking up or down 15mm bore GI tubing including cleaning for refixing or removal to store etc. Complete all as specified and directed by Eng-In-Charge.
Taking down cement plaster on brick or stone walls,etc. including raking joints,hacking for key, scrubbing down with water etc Complete all as specified and directed by Eng-In-Charge.
Demolition of brickwork of stone/boulder masonry, built in cement mortar inlcuding all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles Complete all as specified and directed by Eng-In-Charge.
M&L for PCC 1:4:8 type D-2 (40mm graded agg) is in foundation filling and mass concrete Complete all as specified and directed by Eng-In-Charge.
Stone walling of random rubble with best quality locally available harder stone such as granite, trap or basalt, brought upto courses, well bonded, bedded, solidly hearted and built in cement mortar 1:4, complete all as specified & directed.
Extra over stone walling of granite, trap or basalt stone for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc 20mm, complete all as specified & directed.
PCC 1:3:6, (nominal mix), type C-2, using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified & directed.
M & L Reinforced concrete pipes, class NP 2 with one collar per length of pipe 450 mm dia, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
100 mm thick PCC 1:2:4, nominal mix, type B2, using 40mm graded crushed stone aggregate as in flooring/paving, surface finished even and smooth without using extra cement, complete all as specified.
Precast cement concrete 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match, complete all as specified.
M&L for reinforced cement concrete (Nominal mix ) 1:1.5:3 (20mm graded aggregates) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs, under-reamed piles and mass concrete Complete all as specified and directed by Eng-In-Charge.
M&L for reinforced cement concrete (Nominal mix ) 1:1.5:3 (20mm graded aggregates) as in column, pillars, piers, post and struts Complete all as specified and directed by Eng-In-Charge.
M&L for reinforced cement concrete (Nominal mix ) 1:1.5:3 (20mm graded aggregates) as in beams, cantilevers, bressummers, lintels Complete all as specified and directed by Eng-In-Charge.
M&L for reinforced cement concrete(Nominal mix ) 1:1.5:3 (20mm graded aggregates) as in slab supported on walls , beams and columns in floors, roofs landings balconies, staircase, canopies , deck slabs and in shelves Complete all as specified and directed by Eng-In-Charge.
M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending, binding spirally hooping for columns, hooking ends, binding with with mild steel wire (annealed) not less than 0.9mm dia of securing Complete all as specified and directed by Eng-In-Charge.
M&L for Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia or securing with clips Complete all as specified and directed by Eng-In-Charge.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders Complete all as specified and directed by Eng-In-Charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams, and similar work ; vertical or to batter to rough finished surface of concrete, Complete all as specified and directed by Eng-In-Charge.
Formwork to rough finished surfaces of concrete for flat to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floor and beams etc Complete all as specified and directed by Eng-In-Charge.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete surface square or rectangular or polygonal, Complete all as specified and directed by Eng-In-Charge.
Formwork to soffits of suspended slabs fair finished surfaces such as roof slabs, floor slabs landing and similar work not exceeding 200mm thick Complete all as specified and directed by Eng-In-Charge.
Returning filliing in in layers n exc 25 cm thick including spreading, levelling, watering and well ramming Complete all as specified and directed by Eng-In-Charge.
Removing excavated soil to a distance n.exc 50m & depositing where directed at a level n.exc 1.5m above the starting point Complete all as specified and directed by Eng-In-Charge.
Soil obtained from excavation use for filling under floors or in foundation including watering and consolidation Complete all as specified and directed by Eng-In-Charge.
M&L hardcore of gauge n exc .63mm, deposited, spread and levelled as in layers n exc 15cm thick, watered and rammed to a true surface with broken stone or boulders Complete all as specified and directed by Eng-In-Charge.
M&L 75mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub floors, sub bases, floor and paving etc Complete all as specified and directed by Eng-In-Charge.
M&L for 40mm thick cement concrete type B-1, 1:2:4(20mm graded aggregate) as in sub floors, sub bases, floor and paving etc Complete all as specified and directed by Eng-In-Charge.
M&L for 25mm thick cement concrete type B-1, 1:2:4(20mm graded aggregate) as in sub floors, sub bases, floor and paving etc Complete all as specified and directed by Eng-In-Charge.
M&L for brickwork with subclass "B" bricks straight or curved on plan exc. 6m mean radius in cement mortar (1:6) Complete all as specified and directed by Eng-In-Charge.
Rendering 10mm thick in cement and sand mortar 1:6 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth using extra cement complete all as specified
Rendering 15mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth using extra cement complete all as specified
M&L for preparing new plastered surface of external walls and applying two coat of exterior emulsion over one coat of primer Complete all as specified and directed by Eng-In-Charge.
M&L for preparing new surfaces plastered of walls and applying two coat of oil bound distermper over a coat of primer Complete all as specified and directed by Eng-In-Charge.
M&L preparation of new plaster surfaces of walls and applying two coats of cement base paints to walls Complete all as specified and directed by Eng-In-Charge.
M&L for Preparation of old surface including washing, rubbing down and stopping of distempered and painted surface of walls and applying one coat of cement base paint, complete all as specified Complete all as specified and directed by Eng-In-Charge.
S&F for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe 410 W (Gde E-250) quality A Complete all as specified and directed by Eng-In-Charge.
S&F for rolled mild steel in plates (plain or chequred) channels, square or cut or notched (ordinary or counter sunk) forming of Fe 410W (Gde E-250 quality A) Complete all as specified and directed by Eng-In-Charge.
S&F MS bolts of dia exc 16 to 20mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 22.5cm and n exc 30cm long Complete all as specified and directed by Eng-In-Charge.
S&F framed work in tubular pipes such as grills, gratings etc with ends of bar shouldered or rivetted , walk ways ,railings and similar work conforming to FE 290 Gde E-165 Complete all as specified and directed by Eng-In-Charge.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer Complete all as specified and directed by Eng-In-Charge.
M&L pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of green colour having tensile strengh of 550 Mpa as in roof covering/cladding to wall, fixed with J type or cranked hook bolts in lieu of self tapping screws Complete all as specified and directed by Eng-In-Charge.
M&L for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of green colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with J type or cranked hook bolts in lieu of self tapping screws as specified Complete all as specified and directed by Eng-In-Charge.
S&F with second class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints Complete all as specified and directed by Eng-In-Charge.
S&F 35 mm thick second class hardwood factory made plain framed panelled shutter (two pannel) with lock rail and panel of 9 mm B.W.P. comercial ply or 12 mm veneered particle board with commercial veneeing on both faces. The size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated Complete all as specified and directed by Eng-In-Charge.
S&F steel windows with side hung shutters including box type hinges with steel handle made of flat iron 20 x 3 mm, 150mm long 01 Nos each leaf and 125mm MS tower bolt 2 Nos in each leaf and steel peg stay and tie rod of 10mm dia complete with glazing bars dovetailed or welded Complete all as specified and directed by Eng-In-Charge.
M&L solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube Complete all as specified and directed by Eng-In-Charge. Make:- Rajshree / Everest.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail , lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheet to be fitting in MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvant cement supplying and fixing in the frame at site Complete all as specified and directed by Eng-In-Charge.
S&F steel ventilators with top hund shutter including hihges steel peg stay Complete all as specified and directed by Eng-In-Charge.
S&F MS bands, staps,hold fasts etc and similar small article confirming to Fe-290 Gde E-165 Complete all as specified and directed by Eng-In-Charge.
S&F Sheet glass 4 mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane Complete all as specified and directed by Eng-In-Charge.
M&L for preparation of new or previoulsy untreated wood surface of any description, over 10 cm width or girth, not other wise described and applying two coats of synthetic enamel paint over a coat of pink primer Complete all as specified and directed by Eng-In-Charge.
S&F 100mm size butt hinges extruded aluminium alloy with galvanised mild steel hige pin, anodised and fixed type C-21 Complete all as specified and directed by Eng-In-Charge.
S&F aluminium anodised barrel tower bolt 150 mm long Complete all as specified and directed by Eng-In-Charge.
S&F 150 mm size aluminum handle cast type Complete all as specified and directed by Eng-In-Charge.
S&F 300 mm long aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extuded sections or MS Complete all as specified and directed by Eng-In-Charge.
M&L for second class soft wood wrought in scantling timed fixed Complete all as specified and directed by Eng-In-Charge.
S&F Plain fillets, square rectangular or triangular in section wrought, secured with nails or brad, 2nd class soft wood (kail) sectional area exc 13 sqcm but not exc 25 sqcm as in cover fillets complete , all as specified and directed.
M&L plain fillets second class soft wood square rectangular or triangular in section clean swan secured with nails or brads n exc 3 and n exc 6 sqcm Complete all as specified and directed by Eng-In-Charge.
S & F for 4mm thick veneered decorative plywood,grade 1 (with BWR resin) with decorative face veneers on one face fixed with nails to timber frame work in ceiling Complete all as specified and directed by Eng-In-Charge.
M&L 75mm thick PCC type C-2 1:3:6 40 mm graded aggregrate as in plinth protection to be cast in panels 1.50 Sqm each panel in an outward slope of 1 in 10 with 6mm wide joints filled with bitumen mastic filing Complete all as specified and directed by Eng-In-Charge.
M&L for screed bed or bedding layer of mortar 15mm thick to CM 1:6 as under floor tiles Complete all as specified and directed by Eng-In-Charge.
M&L rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished fair and even under vertical tiles Complete all as specified and directed by Eng-In-Charge.
M&L coloured glazed ceramic tiles in vertical surface 450x300 X 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match Complete all as specified and directed by Eng-In-Charge.
M&L coloured non skid ceramic tiles 7 to 8mm thick (square/ rectan gular) area of each tiles exc 0..18 sqm but n.exc 0.38sqm 8mm thick,as in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match Complete all as specified and directed by Eng-In-Charge.
S&F for 25mm bore, 3-layer PP-R polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stbility for hot & cold water supply incuding all PP-R plain & brass t hreaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc Complete all as specified and directed by Eng-In-Charge.
S&F in repair vitreous china WHB, white, flat ack, size 550 x 400 mm, including cutting for and pinning in ends of brackets or erecting stand etc Complete all as specified and directed by Eng-In-Charge.
S&F in rep PVC valve less, syphonic action type flushing cistern, 10 ltr papacity low level, white, with inlet, ball valve, float and handle including brackets Complete all as specified and directed by Eng-In-Charge.
S&F in rep Vitreous china wash down closet pan and trap (pedestal pattern) white including connection to drain ( or outgoing pipe) and flushing pipe, antisyphonage pipe, etc but excluding flushing cistern and flushing pipe, fixed in repair, Complete all as specified and directed by Eng-In-Charge.
S&F plastic water closet seat closed pattern flat bottom and cover and mild steel chromium plated hinging device Complete all as specified and directed by Eng-In-Charge.
S&F in rep Vitreous China squatting pan “Orissa pattern” size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) with CI ‘P’ trap of long arm of suitable size including connection to flush pipe, anti symphonic pipes etc , Complete all as specified and directed by Eng-In-Charge.
S&F 110mm bore PVC (SWR) pipes single socket any length with rubber ring joints laid in trenches or in floors Complete all as specified and directed by Eng-In-Charge.
All as per item 75 but 75 mm bore Complete all as specified and directed by Eng-In-Charge.
S&F 75mm bore PVC (SWR) pipes single socket any length with rubber ring joints fixed in walls Complete all as specified and directed by Eng-In-Charge.
S&F 110mm bore PVC (SWR) bends any radius Complete all as specified and directed by Eng-In-Charge.
All as per item 78 but 75 mm bore Complete all as specified and directed by Eng-In-Charge.
S&F 110mm bore PVC (SWR) T any radius Complete all as specified and directed by Eng-In-Charge.
All as per item 80 but 75 mm bore Complete all as specified and directed by Eng-In-Charge.
S&F 75mm bore PVC (SWR) vent Cowl
S&F for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm bore Complete all as specified and directed by Eng-In-Charge.
S&F in rep 15mm bib tap cast copper chormium plated alloy with capstan handle screwed down screwed for iron pipe or for brass ferrule and fixed in repairs Complete all as specified and directed by Eng-In-Charge.
S&F in repair stop angle valve cast copper alloy chromium plated 15mm dia screwed down, high pressure with capstan handle, screwed both ends for iron pipes or for unions and fixed, Complete all as specified and directed by Eng-In-Charge.
S&F in repair PVC connection 15 mm size with PTMT nuts of length 600 mm Complete all as specified and directed by Eng-In-Charge.
S&F pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed Complete all as specified and directed by Eng-In-Charge.
S&F Tubular towel rail aluminium anodised 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified.
S&F 20mm PP-R gate valves (brass insert) as per requirement of the site Complete all as specified and directed by Eng-In-Charge.
S&F 25 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) etc Complete all as specified and directed by Eng-In-Charge.
S&F in rep Rotational moulded polyethylene water storage tanks of 500 litres capacity (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, oulet and over flow pipe and provision of wash out pipe etc complete all as specified and directed
Demolition and breaking up 150 mm bore drain pipes (Salt glazed ware, AC , PVC or reinforced concrete, set in cement mortar including bed concrete all as specified and as directed by the Engineer-in-Charge.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm concealed in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge. (Note : Cost of for cutting chesing and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate.) (a) One light point controlled by one switch one way
(c) One socket out let 5 Amps 5 pin on independent board
All as per item No 93 here in before but with cable size 2.5 Sq mm for one 3/5 pin 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed by Engr-in-Charge.
S&F of switch piano, flush type, 5 amps, single pole, one way Complete all as specified and directed by Eng-In-Charge.
S&F of socket outlet 2in1, 3 pin 5 Amps flush type Complete all as specified and directed by Eng-In-Charge.
S&F of socket outlet 2in1, 3 pin 15/5 Amps flush type Complete all as specified and directed by Eng-In-Charge.
S&F of switch piano, flush type, 15 amps, single pole, one way Complete all as specified and directed by Eng-In-Charge.
S&F of ceiling rose surface bakelite two terminals Complete all as specified and directed by Eng-In-Charge.
S&F MCB distribution board single pole and neutral 4 way factory made sheet steel, phosphates, powder Coated with 200 Amps rated bas bar, 240 volts, neutral link, earth bar and Din rail double door Complete all as specified and directed by Eng-In-Charge.
S&F of MCB SPN 6-32 Amps, 10 KA,240V, 50Hz, 'C' Series complete all as specified and as directed by Engineer-in-charge
S&F of MCB SP 6 to 32 Amps SP 10 KA,50HZ, 240V, 'C' Series complete all as specified and as directed by Engineer-in-charge
M/L for Sub main wiring with 2 Run of 6 Sqmm cable and one run of 6 sqmm PVC insulated, unsheathed FRLS cable of multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories concealed on wall and surface on ceiling complete all as specified and directed by Engineer in charge.
Supply & fix LED tube light along with fixture, 20 W including taking down old onecomplete all as specified and as directed by Enge -in - Charge
M&L for earthing with galvanised iron earth plate electrode 600mm x600mmx 6mm thick burried directly in ground (Eart pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.00mm dia connected to earth plate electrode by means of bolts,nuts,check nutsand washers,earth wire protected with and including 15 mm bore light grade ISI marked GI pipe upto 7.5 meters long aii as shown in electrical plate no 5 of MES schedule part-1,with and includingPCC 1:2:4 type B1 pit with cover of RCC 1:2:4 type B1,reinforced with welded steel wire fabric not less than 4 kg per sqmtrwith handle andangle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked,GI fannel with GI mesh,filling with mixture of commen salt and charcoal,necessary excavation, refilling, removing away spoiland earth work in any type of soil,including test point, testing and commissioning complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core Complete all as specified and directed by Eng-In-Charge.
Supply and filling dry river sand in trenches including spreading for cushioning of LT UG cablec and punning down complete all as speified and directed by Engr-in-charge. Note : Punned down thickness shall be measured and paid
M&L for well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as speified and directed by Engr-in-charge.
Taking down old unserviceable/deteriorated batten/PVC conduit / cassing capping point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories of single/three phase Complete all as specified and directed by Eng-In-Charge.
M&L for point wiring in PVC casing capping with 1.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with backelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor for one lihjt point/fan point/ex fan point controlled by one 5 Amps switch, one way all as specified and directed by Engineer-in-Charge for the following:- (a)One light, fan, call bell point controlled by one switch.
(b) One 5 Amp socket point controlled by one switch on same board
S&F Socket outlet 2 in 1, 3 pin, 5 &15 A, 240 volts, flush type white finish, ISI Marked Complete all as specified and directed by Eng-In-Charge.
S & F Decorative ultra slim aluminium LED lighting 22 watt fixture with high lumen output, environmental friendly, energy efficient Complete all as specified and directed by Eng-In-Charge. Make : Havells Cat part No LHEXBTP7IN1S022 or equivalent in Crompton/Philips
S&F Lamp holder insulated body with back plate suitable for angle / batten fitting ISI Marked Complete all as specified and directed by Eng-In-Charge.
Supply and fix LED Lamp 10 watt, 240 volts Complete all as specified and directed by Eng-In-Charge.
S&F Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires Complete all as specified and directed by Eng-In-Charge.
S&F MCB SP 240 volt 6 Amp to 40 amp 10 KA capacity having C-curve characteristics connected with suitable lugs Complete all as specified and directed by Eng-In-Charge.
All as per item srl No 126 but SPN 16-32 Amps Complete all as specified and directed by Eng-In-Charge.
M/s GHULAM HASSAN MALIK
M/S HAJI MOHD ASHRAF SUMJI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .