Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7,540Accepted-Finance | L1 | Accepted-Finance L1 items 12 20, 22, 23, 54
Refer to Financial Result Summary | |
| 2 | L1₹8,850Accepted-Finance 56 INDUSTRIAL ESTATE KAMAL ENCON INDUSTRIES LIMITED YAMUNA NAGAR YAMUNA NAGAR HARYANA 135001 UDYAM HR 19 0003018 06AAACK4706E1ZZ R M MII STATUS AS VERIFIED | YAMUNANAGAR | HARYANA | 135001 | L1 | Accepted-Finance L1 Items 6 Refer to Financial Result Summary | |
| 3 | L1₹15,238Accepted-Finance 110 GD ITL TOWER NETAJI SUBHASH PLACE NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | L1 | Accepted-Finance L1 Items 8 Refer to Financial Result Summary | |
| 4 | L1₹18,549Accepted-Finance | L1 | Accepted-Finance L1 Item 26 Refer to Financial Result Summary | |
| 5 | L1₹22,300Accepted-Finance | L1 | Accepted-Finance L1 Items 18 Refer to Financial Result Summary |
Tender Value
₹19 Cr
EMD Value
₹38 L
Closing Date
30 Aug 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Medical Director
GIPMER, 1 JLN MARG, NEW DELHI - 110002
E-TENDER FOR THE PROCUREMENT OF CORONARY AND PERIPHERAL STENTS FOR CARDIOLOGY DEPARTMENT, GIPMER, NEW DELHI
2024_GBPH_259681_1
FNo.411/PUR/GBP/PS/OTE/2024-26
Open Tender
Miscellaneous Goods
Supply
180 days
GIPMER, 1 JLN MARG, NEW DELHI
As per Tender Documents
14 documents required · 14 mandatory
₹0
₹38 L
Yes
1 JLN MARG, NEW DELHI - 110002
10 Jan 2025
18 Jul 2024
31 Aug 2024
18 Jul 2024
30 Aug 2024
1 Aug 2024
24 Jul 2024
A. Non-Medicated Coronary Stent
Balloon-mounted, Non-Medicated Stent on Stainless Steel platform
Balloon-mounted, Non medicated stent on Non- stainless-steel platform
B. Medicated Coronary stent – SIROLIMUS ELUTING
Balloon mounted, Sirolimus-eluting stent with biodurable/biostable polymer*
Balloon-mounted, Sirolimus-eluting stent with biodegradable polymer on stainless steel platform
Balloon-mounted, Sirolimus-eluting stent with biodegradable polymer on a Non-stainless-steel platform with uniform ultrathin struts of less than 60 microns
Balloon-mounted, Sirolimus-eluting stent with biodegradable polymer on a Non-stainless-steel platform with uniform thin struts (60-80 microns)
Balloon-mounted, Sirolimus-eluting stent with biodegradable polymer on a Non-stainless-steel platform with uniform thin struts (60-80 microns), with at least one publication of the quoted product in PubMed indexed journal.
Balloon-mounted, Sirolimus-eluting stent with biodegradable polymer on a Non-stainless-steel platform with uniform strut thickness greater than 80 microns
Balloon-mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform ultrathin struts (up to 60 microns) and diameters inclusive of 2.0 mm to 4.0 mm of varying lengths, with at least one publication of the quoted product in PubMed indexed journal.
Balloon mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform thin struts (61-80 microns) and diameters inclusive of 2.0 mm to 4.0 mm of varying lengths, with at least one publication of the quoted product in PubMed-indexed journal.
Balloon-mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform ultrathin struts (up to 60 microns) and diameters inclusive of 2.25 mm to 4.5 mm or more of varying lengths.
Balloon mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform thin struts (61-80 microns) and diameters inclusive of 2.25 mm to 4.5 mm or more of varying lengths.
Balloon-mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform ultrathin struts (up to 60 microns) of varying lengths including stent length of 8 mm or less, with at least one publication of the quoted product in PubMed indexed journal.
Balloon mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform thin struts (61-80 microns) of varying lengths including stent length of 8 mm or less, with at least one publication of the quoted product in PubMed indexed journal.
Balloon-mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform strut thickness greater than 80 microns of varying lengths including stent length of 8 mm or less
Balloon-mounted, Sirolimus-eluting stent on a Non- stainless-steel platform with uniform ultrathin struts (up to 80 microns) of varying lengths including stent lengths of 48 mm or more across all diameters from 2.5mm to 4.0 mm, with at least one publication of the quoted product in Pubmed indexed journal.
Balloon-mounted, polymer-free, Sirolimus-eluting stent
C. Medicated Coronary stent – EVEROLIMUS ELUTING
Balloon mounted, Everolimus eluting stent with biodurable/biostable polymer* on a Non-stainless-steel platform
Balloon mounted, Everolimus eluting stent with biodegradable polymer on a Non-stainless-steel platform with uniform ultrathin struts (less than 60 microns)
Balloon mounted, Everolimus eluting stent with biodegradable polymer on a Non-stainless-steel platform with uniform thin struts (60-80 microns), with at least one publication of the quoted product in Pubmed indexed journal.
Balloon mounted, Everolimus eluting stent with biodegradable polymer on a Non-stainless-steel platform with strut thickness greater than 80 microns.
Balloon mounted, Everolimus eluting stent on a Non- stainless-steel platform with ultrathin struts (up to 80 microns) and diameters inclusive of 2.0 mm to 4.0 mm of varying lengths, with at least one publication of the quoted product in Pubmed indexed journal.
Balloon mounted, Everolimus eluting stent on a Non- stainless-steel platform with uniform ultrathin struts (up to 80 microns) and diameters of 2.25 mm to 4.5 mm or more of varying lengths, with at least one publication of the quoted product in PubMed indexed journal.
Balloon mounted, Everolimus eluting stent on a Non-stainless-steel platform with uniform thin struts (61-80 microns) of varying lengths including stent length of 8 mm or less, with at least one publication of the quoted product in Pubmed indexed journal.
Balloon-mounted, polymer-free, Everolimus/Biolimus eluting stent.
D. Other Coronary Stents
Balloon-mounted, coronary sirolimus-eluting stent with abluminal drug coating
Balloon mounted, coronary drug (other than sirolimus) eluting stent with abluminal drug coating
Balloon-mounted, Dual drug-coated Drug Eluting stents
Balloon mounted, Zotarolimus eluting stent with biodurable/biostable polymer* on a Non-stainless-steel platform
Coronary stent graft/ Coronary covered stent of variable diameters and lengths
*Biodurable Polymers include SIBS (Polystyrene-b-isobutylene b-styrene), PBMA (poly n butyl methacrylate, PEVA (polyethylene covinyl acetate), PVDF-HFP (poly vinlidene fluoride hexafluoropropylene, PC (phosphorylcholine), Siloxane copolymer and any other commercially approved biodurable polymer
For publication of the quoted product in Pubmed indexed journal, only original research article will be considered. Case reports, case series will not be accepted. The relevent publications highlihting the quoted product must be attached along with technical literature.
E. Peripheral vascular stents (Carotid stents self-expandable)
Nitinol Carotid Stent, 0.014" Guide Wire compatible, 5 – 10 mm Diameter- Non tapered
Nitinol Carotid Stent, 0.014" Guide Wire compatible, 5 - 10mm Diameter- tapered
Nitinol Monorail Closed cell design with flared ends- tapered, 6F Sheath Compatible
F. Peripheral vascular stents (Renal stents balloon mounted)
Monorail Balloon mounted Renal stents of diameter 4-7 mm of varying lengths
Monorail 0.014" wire compatible Cobalt Chromium renal stent of diameter 4-7 mm of varying lengths
Monorail 0.014” wire compatible Cobalt Chromium renal stent of diameter 5-7 mm, of varying lengths, 5 F Compatible
G. Balloon mounted Peripheral stents
Peripheral stainless-steel stent of diameter 5-10 mm and length 20- 60 mm
Peripheral stainless-steel stent of diameter 5-10 mm and length 17-57 mm
Peripheral stainless-steel stent of diameter 11-14 mm and length 20-60 mm
Peripheral stainless-steel stent high radial strength of diameter 15-24 mm
Peripheral balloon expendable Cobalt Chromium stent with high radial force with smaller introducer sheath, semi flexible hybrid cell design, with lengths from 13 mm up to 57 mm & diameter from 6 mm up to 32 mm.
Peripheral Cobalt Chromium Stent 5-10 mm diameter and length 15- 60 mm
Peripheral Cobalt Chromium Stent with thin struts, over the wire, 0.035” guide wire compatible, 6F Sheath compatible across all sizes (7 mm to 10 mm diameter)
Peripheral Stainless-Steel Stent, Monorail, all sizes
Peripheral Cobalt Chromium Stent, Monorail base, all sizes
H. Self-expanding Peripheral stents
Over the wire, 0.035” wire compatible, nitinol/ elgiloy peripheral self-expanding stent of diameter 5-10 mm of varying lengths
Over the wire, 0.035” wire compatible, nitinol/ elgiloy peripheral self-expanding stent of diameter 11-14 mm of varying lengths
Over the wire, 0.035” wire compatible, nitinol/ elgiloy peripheral self-expanding stent of diameter 5-14 mm and of varying lengths
Over the wire, 0.035” wire compatible, nitinol/ elgiloy peripheral self-expanding stent of diameter 10-24 mm of varying lengths
0.018” wire compatible nitinol/ elgiloy peripheral self- expanding stent of all sizes and variable lengths
0.035’’ wire compatible Nitinol/elgiloy peripheral self- expanding stent of all sizes and varying lengths
Self-expandable peripheral stent dedicated for SFA/ Popliteal and across joint intervention in all diameters with lengths 150 mm or more
Over the wire, 0.035" wire compatible, self-expandable stent of braided construction, with higher flexibility and improved compression resistance, of diameter 5-24 mm variable lengths
I. Peripheral Drug eluting stent
Drug eluting peripheral stents of all diameters and varying lengths
J. Peripheral Stent Grafts
Aortic Stent graft Self Expandable Tubular Diameter 23 mm or less and 34 mm or more with Delivery System. The manufacturer should agree to supply the size customized to the patient’s anatomy based on CT imaging
Aortic Stent graft Self Expandable Bifurcated Diameter 23 mm or less and 34 mm or more with Delivery System & contralateral limb. The manufacturer should agree to supply the size customized to the patient’s anatomy based on CT imaging
Aortic Stent graft system for thoracic endovascular aortic repair with Delivery System. Proximal stent graft diameter from 22 mm or less to 46 mm or more in varying lengths. The manufacturer should agree to supply the size customized to the patient’s anatomy based on CT imaging
Extension tube graft for Aortic Stent Graft
Iliac extension for Aortic stent graft
Balloon expandable Peripheral Stent graft of all diameters and varying lengths
Balloon expandable Stent graft with PTFE expandable to 24 mm
Self-expandable Peripheral Stent graft of all diameters and varying lengths
Self-expandable covered stent of diameter 6mm-14mm and length 20-70 mm
Self-expandable Aortic Stent graft expandable to 24 mm
Self-expandable Stent graft expandable to 14 mm
PTFE covered balloon expendable Cobalt Chromium stent with high radial strength, of length 18 to 57 mm and diameters up to 35 mm
K. Peripheral stents for Coarctation of Aorta
Balloon Expandable Stent up to 30mm in Diameter Stents are Composed of 0.013” platinum-iridium wire arranged in either an 8 zig or 10 zig patterns Un-Covered and Unmounted
Balloon Expandable Stent up to 30mm in Diameter Stents are Composed of 0.013” platinum-iridium wire arranged in either an 8 zig or 10 zig patterns Un-Covered and Pre-mounted on Balloon in Balloon (Two Balloons on same shaft)
Balloon Expandable Stent up to 30mm in Diameter Stents are Composed of 0.013” platinum-iridium wire arranged in either an 8 zig or 10 zig patterns Covered and Unmounted
Balloon Expandable Stent up to 30mm in Diameter Stents are Composed of 0.013” platinum-iridium wire arranged in either an 8 zig or 10 zig patterns. Covered and Pre-mounted on Balloon in Balloon (Two Balloons on same shaft)
Balloon Expandable Peripheral stent diameters upto 30 mm or more in various lengths.
Pre-mounted Balloon Expandable Peripheral stent diameters upto 30 mm or more in various lengths
Boston Scientific India Pvt. Ltd
SAHAJANAND LASER TECHNOLOGY LTD
Onehplus Healthcare Private Limited
PURPLE MICROPORT CARDIOVASCULAR PVT LTD
MULTI MEDICS LLP
KAMAL ENCON INDUSTRIES LIMITED
Newtech Medical Devices Pvt. Ltd.
Meril Life Sciences India Pvt.Ltd.,
India Medtronic Private Limited
Translumina Therapeutics LLP
Dev Health Care
LIFESHIELD MEDICARE
Advanced LifeSciences Pvt. Ltd.
TRIVENI HEALTH CURE PVT LTD
Envision Scientific Pvt. Ltd
stage.html
html • 0.10 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ_340425.xls
BOQ Document • 0.45 MB
Technical_Stent_Cardiology.xls
BOQ Document • 0.06 MB
148507208.pdf
Tender Document • 1.03 MB
Tender_Documents_merged.pdf
Tender Document • 1.24 MB
148507210.html
Tender Document • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .