Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹14.5 L+₹66,625 (4.81%)Rejected-AOC 0 0 KAIMGANJ ROAD KUIYA SANT FARRUKHABAD UTTAR PRADESH 209745 | FARRUKHABAD | UTTAR PRADESH | 209745 | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹15.6 L+₹1.8 L (12.8%)Rejected-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L3 | Rejected-AOC Quoted L3 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
8 Oct 2021, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
CLEANING OF SEWAGE INSTALLATIONS, OH TANKS, UG SUMPS, SWTS INCLUDING REWINDING OF SUBMERSIBLE/CENTRIFUGAL PUMPS AND REPAIR/REPLACEMENT OF WATER LEVEL INDICATIONS AT AF STN CHANDIGARH
2021_MES_474455_1
GE(AF)/CHD/T-29/2021-22
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹30,000
19 Dec 2021
11 Sept 2021
11 Oct 2021
11 Sept 2021
8 Oct 2021
24 Sept 2021
11 Sept 2021 - 17 Sept 2021
Amount
Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exc 1.5 m deep for laying of pipes etc and getting out all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified.
Removal of surplus soil to a distance not exc 50 m away and depositing where directed at a level not exc 1.5 above the starting point complete all as directed.
Dismantling and taking out from trenches the existing DI pipe 100 mm dia with spigot and socketed ends and lead joints including burning out joints and recovering lead etc. including all fittings such as bends, elbow and Tees etc. all as specified and directed.
Dismantling and taking out from trenches the existing CI pipe 150 mm dia with spigot and socketed ends and lead joints including burning out joints and recovering lead etc. including all fittings such as bends, elbow and Tees etc. all as specified and directed.
Dismantling and taking out from trenches the existing CI pipe 100 mm dia with spigot and socketed ends and lead joints including burning out joints and recovering lead etc. including all fittings such as bends, elbow and Tees etc. all as specified and directed.
Dismantling and taking out from trenches the existing CI pipe 80 mm dia with spigot and socketed ends and lead joints including burning out joints and recovering lead etc. including all fittings such as bends, elbow and Tees etc. all as specified and directed. Note: Excavation and earth work will be measured and paid for separately for Srl item No 4 to 7
Dismantling and taking out from trenches/walls/ceilings/floors the existing GI pipe including all fittings such as bends, elbow and Tees etc. of following sizes complete all as specified and directed.
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Note: Excavation and earth work wherever reqd will be measured and paid for separately.
Supplying, laying, Jointing and testing in trenches new ductile iron pipe conforming to IS-839-2000, class K-7 in any length laid in excavated trenches without fitting for run lead joint/ tyton push or rubber gasket joint with spigot and socketed ends of following sizes complete all as specified and directed.ote:- The under mentioned pipelines are unserviceable and burned under runway during extension of runway and could not be retrieved, hence not considered in Sch of Credit.
(a) 150 mm Bore
(b) 100 mm Bore
Note: (i)Excavation/earth work & push on type rubber joint/ead joint will be measured and paid for separately
Supplying, laying, Jointing and testing in trenches CI pipe centrifugally cast class 'LA' suitable for run lead joint with spigot and socketed ends in any length complete all as specified and directed of following dias
150 mm bore
100 mm bore
80 mm bore
Note: Excavation/earth work & push on type rubber joint/ead joint will be measured and paid for separately
Supplying, laying, jointing and testing GI Pipe medium grade inclusive of all fittings such as bends, Tee, union, elbow, reducer and Socketed etc. ISI marked of following sizes complete all as specified and directed.
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Note: Excavation and earth work will be measured and paid for separately
Supply & fixing in replacement including taking down old sluice valve CI body with Gun metal/Steel spindle with hand operated iron wheel both ends flanged and drilled including ring, nuts, bolts class PN 1.6 conforming to IS 14846-2000. ISI Marked of following sizes complete all as specified and directed.
150 mm bore
100 mm bore
80 mm bore
Note: Earthwork shall be measured and paid for separately.
Supply & fixing in replacement including taking down old Gun metal/globe/ gate valve with iron wheel handle screwed at both ends ISI marked suitable for GI pipe of following sizes complete all as specified and directed.
25 mm bore
40 mm bore
50 mm bore
80 mm bore
S&F in replacement Cast Iron Air release Valves with single air Outlets, conforming to IS 14845-2000, duly ISI marked with nut, bolts, washers and rubber gasket of following sizes dia bore and fixing up in CI/DI on Water supply mains complete all as specified and directed.
100 mm bore
80 mm bore
S & F in replacement foot valve confirming to IS:4036, of size 80 mm dia (GI/CI) complete
S&F in replacement of non return valve/reflex valve with by-pass arrangement od following dia ISI marked complete all as specified and directed.
150 mm (6") dia
80 mm (3") dia
M&L for CI/DI fitting in replacement i.e. bends any type radius/angles tapers and type straight bends increasing, decreasing or double socket etc. Tee pieces Collars Taps push on type rubber joint/lead joint and plugs etc. ISI Marked not exceeding 150 mm bore complete all as specified and directed. Note: Joints, excavation and earthwork is included in rate quoted.
M&L for run lead joints suitable for following sizes for spigot and socketed CI/DI pipes and fittings complete all as specified and directed.
150 mm bore
100 mm bore
80 mm bore
M&L for tyton push or rubber gasket joints suitable for following sizes for spigot and socketed ductile iron pipes and fittings complete all as specified and directed.
150 mm bore
100 mm bore
80 mm bore
Repair/rectification to leakage of CI water pipe line of following size spigot and socket ends complete all as specified and as directed by Enge-in-Charge.
150 mm bore
100 mm bore
80 mm bore
Note :- Materials i.e lead/lead wool, Spunyarn and excavation work for any depth, returning/ filling & removal etc are included in the quoted rates.
Cutting Existing steel tubing for alteration or additions (each cut measured) in any condition complete all as specified and directed.
40 to 50 mm bore
50 to 100 mm bore
Material & labour for construction of brick missionary valve pit of size 90cmx90cmx 105cm (internal dimension) with frame of angle iron and MS sheet cover 3 mm thick and locking arrangements duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including dismantling and removal of existing broken MS frame and cover etc. complete all as specified and directed by Engineer-in-Charge.
All as per item No. 22 above but 60cmx60cmx60cm (internal dimension)
M & L for making good hard standing/road cutting portion etc with PCC 1:2:4 type B2 using 40 mm graded crushed stone aggregate complete all as specified and directed.
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia of following sizes including all fittings complete all as specified and directed.
15 mm bore.
20 mm bore.
25 mm bore.
Supply & fixed in repairs straight plain brass ferrules (or connecting screw) of following sizes, screwed both ends complete all as specified and directed.
15 mm bore.
20 mm bore.
25 mm bore.
Removing of chocked position of CI pipe line upto 150 mm dia (max 5 or 5.5 mtr pipe length consider as each job) by opening the fitting/joints and cleaning the pipe line for free flow of water & refixing in its original location complete all as specified and directed. Note :- Materials i.e lead/lead wool, spuryan and excavation & earth work for any depth etc are included in the quoted rates.
Cleaning of RCC overhead water storage tank cap 1,00,000 Gallons at 40 Ft staging in two compartments by tank clean process as below
Mechanical removal of all remaining dirty water by reqd capacity of submersible pump.
Removal of sludge by vacuum operated pump.
Dewatering the over head tank by any means and cleaning the complete inner surfces by rubbing / scrapping by wire brush to remove the sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely and details of tanks like date of cleaning ,capacity of tanks etc shall be written on the out side of the tank with synthetic enamel paint with letter size 20 cm high in white colour, over a black background of size 100x30 cm all as specified and directed.
Removing of all dirty particles by industrial wet vacuum cleaner leaving the tank 99.9% physical cleaned.
Sterilization of tank by eco-friendly degradable and highly effecting all pathogens agent of tank clean sterilization of tank atmosphere by industrial V.V radiator leaving the tank complete sterile and writing the date of cleaning with paint all as specified and directed.
All as per item No 28 above but RCC overhead tank of cap 25000 Gallons single compartment 40 ft staging.
All as per item No 28 above but underground sump of capacity 20000 glns.
All as per item No 28 above but RCC Static water storage tank of any capacity upto 25000 galns and including two coats of white wash.
Cleaning of sewage sump well 5 mtr dia and 9 mtr deep ground level by mechanical/manual removal of dirty water/vegetation sludge. Note: - (1) the contractor shall make temp ditch 10 mtr away from the well to dump the sludge removed from the well and refill the same after the work is over. (2) The contractor shall make temp arrangements for blocking the flow of sewage till the completion of work.
All as per item No 32 above but of Size 3 Mtrs dia and 6 Mtrs deep
Over hauling/maintenance to chlorination dozing plants sodium hypo chloride solution type of any make & model including replacement of defective motor, repairs to pump & replacement of all damage parts if any (from sodium hypo chloride solution tank to distrutution line) etc for complete serviceability of systems all as specified and directed.
M& L for dismantling electric connection from the LT panel board and taking out non-clog dry motor submersible pump 7.5 HP 3 phase 415 V, 50 C/S with column pipes, re-winding with existing size of copper conductor wire PVC insulated and repair to pump by replacing the neck rings, motor bush distance sleeves pump coupling stud sealing kit thrust plate and nuts and re fixing the same position and testing complete all as specified and directed.
All as per item No 35 above but 5 HP submersible pump.
Repairs to Mono block Pumping set 0.5 HP,re-winding with existing size of copper conductor wire PVC insulated and repair to pump by replacing the neck rings, motor bush distance sleeves pump coupling stud sealing kit thrust plate and nuts and re fixing the same position and testing complete all as specified and directed
Material and labour for Dismantling electric connection from the panel Board and taking out submersible pump and Motor complete set of capacity 40 HP with column pipes of any size, repair and rewinding of submersible motor with appropriate gauge PVC insulated copper wire and repair to pump by replacing the neck-rings, GM impellors motor bush distance sleeves, pump coupling stud and Nuts sealing Kit, including replacement of Nuts and Bolts of size ½” x 3” where required, thrust plate and refixing in position and testing complete all as directed.
All as per item No 38 above but capacity of pump set 30 HP
M& L for dismantling of centrifugal Mono block pump set of 15 HP capacity from base for complete over hauling , rewinding with suitable size of copper winding wire including replacement of worn out impeller, ball bearing pump gland shaft bush, with nuts, bolts welding turning and polishing of pump shaft including re fixing testing complete all as directed
All as per item No 40 above but capacity of pump set 30 HP
Supply & Fixing & lowering after cutting required length of existing pattern suction/delivery MS Column pipe 150 mm dia 3 Mtr long Medium grade with MS Flange including welding, cutting and replacement of Nuts and Bolts including/taking out unserviceable MS Column pipe 150mm dia. Make:- Tata/Jindal/Nidhi
All as per item No 42 above but MS column pipe of 100 mm dia
All as per item No 42 above but MS column pipe of 80 mm dia
M & L Providing cable joint water proof to submersible cable of size 3 Core up to 16sqmm complete all as specified and directed
Supply only Sodium Hypo Chlorite (NaOCL) chemical solution confirming to IS - 1673/86 having Chloride contents at the rate of 10% by weight (bleach liquid Solution) complete all as specified and as directed by the engineer- in- Charge. Note:- Chemical solution shall be supplied by the contractor as on requirement basis through out the currency of the contract. Therefore the contractor shall procure the chemical solution in piecemeal as per requirement. The material shall be deposited with AGE EM-II (AF) Chandigarh and RV shall be prepared accordingly. Contractor shall also arrange indepenndent testing of chemical form Govt authorized laboratory at his own expense. The cost of testing shall be deemed to be included in the quoted rate. Payment of supply of Sodium chlorite solution shall only be made on production of test report.
Supply & Fixing in repair Fully automatic star delta starter in sheet steel enclosure, MN type motor rating AC-3 duty, 415 V, 50 Hz three phase, 40-60 HP complete all as specified.
Supply & Fixing in repair Fully automatic star delta starter in sheet steel enclosure, MN type motor rating AC-3 duty, 415 V, 50 Hz three phase, 15 HP complete all as specified.
S&F PVC in repair insulated and PVC sheathed submersible cable flat 3 core 16 sqmm multistranded copper conductor suitable for working voltage 1100 volts including securing to column pipe with MS flat clamps of suitable size and connections to motor/starter.complete all as specified and directed.
S&F PVC in repair insulated and PVC sheathed submersible cable flat 3 core 10sqmm multistranded copper conductor suitable for working voltage 1100 volts including securing to column pipe with MS flat clamps of suitable size and connections to motor/starter.complete all as specified and directed.
Dismantling/taking out existing stainless steel solar tank of capacity upto 500 litre, from existing structure (mounting stand), disconnecting inlet and outlet connection & all the electrical connection complete etc all as directed by Engineer-in-Charge.
Material & labour for refixing stainless steel solar tank of capacity upto 500 ltrs, on structure (mounting stand), connecting inlet and outlet connection by using GI pipe, fittings, accessories & all the electrical connection complete etc all as directed by Engineer-in-Charge.
Material & labour for cleaning existing stainless steel solar tank of capacity 300 litre from inner side, brazing/descaling the brass / copper tubes of solar panel from inside with suitable chemical, including repair to minor leaking complete etc all as directed by Engineer-in-Charge.
Material & labour for cleaning existing stainless steel solar tank of capacity 500 litre from inner side, brazing/descaling the brass / copper tubes of solar panel from inside with suitable chemical, including repair to minor leaking complete etc all as directed by Engineer-in-Charge.
Material & labour for fixing glass wool with outer insulating material to existing stainless steel solar tank of capacity 300 litre complete etc all as directed by Engineer-in-Charge.
Material & labour for fixing glass wool with outer insulating material toexisting stainless steel solar tank of capacity 500 litre complete etc all as directed by Enngineer-in-Charge.
Material & labour for fixing of new toughened glass collector in existing SWHS collector glasses of sizes 1m x 2m x 4 mm thick complete etc all as directed by Engineer-in-Charge.
Supply & fixing in repair, heating element 3 KW (Heavy duty) to stainless steel solar tank by disconnecting electric connection & after refixing heating element reconnect electric connection complete etc all as directed by Engineer-in-Charge.
Supply & fixing in repair temperature gauge on hot water tank as per original pattern and size complete etc all as directed by Engineer-in-Charge.
Supply & fixing in repair MCB SP 16 Amps, 10 KA, C curve complete etc all as directed by Engineer-in-Charge. Make- Havells/L&T/ABB/Legrand.
Supply & fixing inrepair hose pipe connecting with solar plate collector and hot water reservoir tank as per site requirement complete etc all as directed by Engineer-in-Charge.
Supply & fixing in repair rock wool insulation/ nitryl rubber insulation with outer cladding of aluminium sheet of 26 gauge for existing 20 mm dia GI pipe complete etc all as directed by Engineer-in-Charge.
M&L in repair for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to galvanised Iron strip of size 35x6mm by means of bolts, nut check nuts and washers earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to test point all as shown in electrical plate No. 3 of SSR - 2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1;2:4), type B-1 reinforced XPM of weight not less than 4 Kg/Sqm and MS frame etc, complete all as specified. Notes:- (i) The unit rate includes copper earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. (ii) The complete earth system shall be guaranteed to give result less than 1 ohm resistance. (iii) Complete earthing will be redone at no extra cost to department, if result is found below 1 ohm. all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated inculding brazing/testing on completion.
Attending the complaint of water supply for leakage, Pipe broken, line block, cleaning of pipe, float valve and all related to water supply find out the problems & rectifying the same day without affecting the services. Note :- (i) Compaint should be attended immediately in one hour and to be rectified. (ii) Complaint should be received 24 hours through phone. (iii) Compaint attendee should have specific knowledge of water supply. (iv) Contrator will have to provide all tools & Plant, Vehicle & phone etc. reqd by the attendent and no extra payment will be allowed on this account.
Supply and fixing in replacement 15 mm bib tabs standard PTMT any colour high pressure screwed for iron pipe minimum weight 15 mm - 90 Grams fix complete, Make: Prayag/Shakti/Polytuf
Supply only Lead wool superior quality
Supply only Pig lead superior quality
Supply only Spun yarn superior quality
Supply and fixing three phase monoblock pump set of cap 2HP and discharge size 80mm flow range 846-450 LPM Headrange 6-12 mtr complete all as specified & directed Make:- kirlosker/crompton greaves/Beacon Notes:- old u/s pump set will be property of department
Testing of drinking water of pump houses with the following exanimation :- (a) Turbidity (b) PH (c) Residual Chlorine (d) Total Alkalinity (as CaCO3) (e) Total Hardness (as CaCO3) (f) Chlorides (as CI) (g) Free & Saline Ammonia (h) Total Dissolved Solids (j) M.P.N of coliform Bacilli per 100ml of water
Note:- Amount of credit of Rs 37649.00 for retrieved materials is mentioned in Schedule of Credit Page No 110 of tender documents in pdf form which will be deducted offline while acceptance of tender.
R S ENTERPRISES
PARTAP ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .