| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr Quoted ₹1.5 Cr | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹1.5 Cr+₹7.1 L (4.81%)Rejected-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹1.5 Cr+₹7.1 L (4.81%) | L2 | Rejected-AOC OTHER THAN L1 |
| 3 | L3₹1.6 Cr+₹16.7 L (11.4%)Rejected-AOC GURDASPUR ROAD NEAR SAINIK MANDIR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.6 Cr+₹16.7 L (11.4%) | L3 | Rejected-AOC OTHER THAN L1 |
| 4 | L4₹1.6 Cr+₹17.6 L (12.0%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.6 Cr+₹17.6 L (12.0%) | L4 | Rejected-AOC OTHER THAN L1 |
| 5 | L5₹1.7 Cr+₹25.1 L (17.0%)Rejected-AOC | ₹1.7 Cr+₹25.1 L (17.0%) | L5 | Rejected-AOC OTHER THAN L1 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
12 Dec 2022, 6:00 pmClosed
CWE YOL
HEADQUARTERS COMMANDER WORKS ENGINEERS YOL CANTT-176052
ADDN ALTN OF OVERHEAD HT/LT LINE TO UNDERGROUND CABLES AND ALLIED WORKS AT REC, SKE, 28 CAMP ANF 25 CAMP AT YOL CANTT
2022_MES_561941_1
CWE/Y-72/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
YOL
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE KH YOL
₹2.2 L
Yes
28 Jan 2023
7 Nov 2022
19 Dec 2022
7 Nov 2022
12 Dec 2022
28 Nov 2022
Amount
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in any type of soil, complete all as specified and directed.
All as per Srl Item No 1.00 above but depth exceeding 1.5 mtr and not exceeding 3.0 mtr.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar ands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork where required complete all as specified and directed.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick , complete all as specified and directed.
Removing carefuully exisiting bus bar with MCCB from site and transporting it to MES Power House and depositing in MES Store yard, comlpele all as specified.
Supply, jointing, fixing or passing through pipe, trenches or ducts, commissioning and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (Heavy duty) with aluminium conductor, 11000 Volts grade, cross sectional area 120Sqmm, 3 core, suitable for 11 KV earthed system confirming to IS 7098 Part-2 for insulation and for conductors Class 2 to IS 8130-84, in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing complete all as specified and directed. (Note : Excavation, earth work, PCC Cable cover, sand cushioning and GI pipe etc shall be measured &paid for separately).
Supply, jointing, fixing or passing through pipe, trenches or ducts, commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm 3.5 core in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing complete all as specified and directed. (Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured &paid for separately).
Supply, jointing, fixing or passing through pipe, trenches or ducts, commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm 3.5 core in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing complete all as specified and directed. (Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured &paid for separately).
Supply, jointing, fixing or passing through pipe, trenches or ducts, commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 Sqmm 3.5 core in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing complete all as specified and directed. (Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured &paid for separately).
Supply, jointing, fixing or passing through pipe, trenches or ducts, commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm 3.5 core in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing complete all as specified and directed. (Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured &paid for separately).
Supply, jointing, fixing or passing through pipe, trenches or ducts, commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 120 Sqmm 3.5 core in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing complete all as specified and directed. (Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured &paid for separately).
Supply, jointing, fixing or passing through pipe, trenches or ducts, commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 4 core in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing complete all as specified and directed. (Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured &paid for separately).
Supply, jointing, fixing or passing through pipe, trenches or ducts, commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 2 core in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing complete all as specified and directed. (Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured &paid for separately).
Dismantling of ACSR or AAC conductor, any type and size and removing from site, complete all as specified.
Dismantling steel poles/struts, any size and removing from site, complete all as specified.
Dismantling concrete poles/struts, any size and removing from site, complete all as specified.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and removing from site, complete all as specified.
Dismantling insulators any type, any size and removing from site, complete all as specified.
Dismantling stay assembly complete (including demolition of concrete, etc. and excavatio required) and removing from site, complete all as specified.
Dismantling earth wire or copper conductor, service feeder or distributor span and removing from site, complete all as specified.
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. o and removing from site, complete all as specified.
Taking out old LT cable from 10 Sqmm to 50 Sqmm, any core and removing from site, complete all as specified.
Taking out old LT cable from 70 Sqmm to 120 Sqmm, any core and removing from site, complete all as specified.
Cable route indicator made out of 2 mm thick mild steel sheet of size 20 cms X 15 cms duly coated with two coats of black paint over a coat of red oxide primer duly written the size of LT/ HT cable in white paint and welded to equal angle of size 30X30X3mm, 45 cms long and errected in ground in such a way that it is 15 cms above ground level and 30 cms below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-I, using 20 mm graded crushed stone aggregate of size 15 cms X 20 cms X 45 cms all as specified & directed. Note:- Cost of PCC and earth work & excavation shall be deemed to be included in unit rate quoted by contractor.
Structural steel work as in cross arms, bracings, supports, clamp and back plate fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in-Charge and applying two coats of aluminium paint over one coat of red oxide zinc chrome primer including preparation of surfaces , complete all as specified & directed.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC , complete all as specified and directed. Note : Excavation & earth work and PCC shall be measrued and paid separately.
Lightning arresters (Set of three) expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for 11000 volts complete all as specified and directed.
MCCB 3 pole with Adjustable Thermal & Adjustable Magnetic setting,160 Amps , 50 Hz 415 Volts, having rupturing capacity 35 KA all as specified and directed.
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) Microprocessor MCCB having current rating 200 Amps with rupturing cap 35 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (c) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (d) LED phase indicator lamp ( Qty- 01 set of three) (e) 200 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Outgoing:- (a) Microprocessor MCCB having current rating 125 Amps with rupturing cap 35 KA , AC 415 Volts,three pole, complete with spreader links. (Qty -01 No) (b )MCCB having current rating 32 Amps with rupturing cap 25 KA , AC 415 Volts,three pole, complete with spreader links. (Qty -04 No) Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) Microprocessor MCCB having current rating 125 Amps with rupturing cap 35 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (c) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (d) LED phase indicator lamp ( Qty- 01 set of three) (e) 200 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Outgoing:- (a) MCCB having current rating 32 Amps with rupturing cap 16 KA , AC 415 Volts,three pole, complete with spreader links. (Qty -06 No) Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) Microprocessor MCCB having current rating 125 Amps with rupturing cap 35 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (c) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (d) LED phase indicator lamp ( Qty- 01 set of three) (e) 200 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Outgoing:- (a) MCCB having current rating 32 Amps with rupturing cap 16 KA , AC 415 Volts,three pole, complete with spreader links. (Qty -05 No) Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) Microprocessor MCCB having current rating 100Amps with rupturing cap 35 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (c) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (d) LED phase indicator lamp ( Qty- 01 set of three) (e) 200 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Outgoing:- (a) MCCB having current rating 32 Amps with rupturing cap 16 KA , AC 415 Volts,three pole, complete with spreader links. (Qty -04 No) Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) Microprocessor MCCB having current rating 200 Amps with rupturing cap 35 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (c) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (d) LED phase indicator lamp ( Qty- 01 set of three) (e) 200 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Outgoing:- (a) Microprocessor MCCB having current rating 100Amps with rupturing cap 35 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) MCCB having current rating 32 Amps with rupturing cap 16 KA , AC 415 Volts,three pole, complete with spreader links. (Qty -06 No) Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) Microprocessor MCCB having current rating 160 Amps with rupturing cap 35 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (c) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (d) LED phase indicator lamp ( Qty- 01 set of three) (e) 200 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Outgoing:- (a) Microprocessor MCCB having current rating 100Amps with rupturing cap 35 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) MCCB having current rating 32 Amps with rupturing cap 16 KA , AC 415 Volts,three pole, complete with spreader links. (Qty -04 Nos) Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) Microprocessor MCCB having current rating 160 Amps with rupturing cap 35 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (c) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (d) LED phase indicator lamp ( Qty- 01 set of three) (e) 200 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Outgoing:- (a) MCCB having current rating 32 Amps with rupturing cap 16 KA , AC 415 Volts,three pole, complete with spreader links. (Qty -06 Nos) Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) MCCB having current rating 320 Amps with rupturing cap 35 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (c) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (d) LED phase indicator lamp ( Qty- 01 set of three) (e) 200 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Outgoing:- (a) Microprocessor MCCB having current rating 160Amps with rupturing cap 35 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) MCCB having current rating 32 Amps with rupturing cap 16 KA , AC 415 Volts,three pole, complete with spreader links. (Qty -05 Nos) Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) MCCB having current rating 63 Amps with rupturing cap 25 KA , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (b) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (c) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (d) LED phase indicator lamp ( Qty- 01 set of three) (e) 200 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Outgoing:- (a) MCCB having current rating 32 Amps with rupturing cap 10 KA , AC 415 Volts,three pole, complete with spreader links. (Qty -02 Nos) (b) Timer switch 20 Amp with 4 pole contactor-01 No. Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing
Painting to existing Prestressed concrete poles, 9m long with two coats of cement base paint including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (Total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
Painting to existing steel tubular LT poles, 9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (Total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
Supply, installation, commissioning and testing bus chamber factory made, CPRI approved, fabricated out of 1.6 mm thick mild steel sheet and vermin proof with neoprene gasket having front opening and locking arrangement with IP-54 protection as per IS-8623, duly powder coated (Internally and externally) comprising of 04 Nos aluminium bus bars of 200 Amps rating duly drilled holes for connections, RYB insulated with different color code and sleeved insulators complete prewired and copper cable connection with all incoming and outgoing cable connection with suitable size of lugs and glandscomplete all as specified.
Supply, installation, connecting and testing of street light junction box, pole mounted, fabricated out of 2 mm thick CRCA sheet, powder coated having front opening with magentic lock complete with bus bar 4 Nos suitable for 3 phase 4 wire supply system made out of aluminium strip 20x3mm, including one No. MCB SPN, 240 Volts 'C' curve type 6 Amps with rupturing capacity 10 KA, including fixing arrangement made of MS Clamps, requisite nuts, bolts and washers complete all as specified. Note : Cable entries should be through proper cable gland
MCCB 3 pole with Adjustable Thermal & Adjustable Magnetic setting, 200 Amps , 50 Hz 415 Volts, having rupturing capacity 35 KA including taking down old MCCB from existing LT Panel all as specified and directed.
MCCB 3 pole with Adjustable Thermal & Adjustable Magnetic setting, 250 Amps , 50 Hz 415 Volts, having rupturing capacity 35 KA including taking down old MCCB from existing LT Panelall as specified and directed.
MCCB 3 pole with Adjustable Thermal & Adjustable Magnetic setting, 320 Amps , 50 Hz 415 Volts, having rupturing capacity 35 KA including taking down old MCCB from existing LT Panelall as specified and directed.
Boring of holes under road, pavement, hardstanding by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe 150mm bore suitable for 0.4mpa working pressure and making good disturbed surfaces level and smooth , complete all as specified.
Supply, installation, testing and commissioning gang operated air break off load connecting switch HT, 11KV, tripple pole, each plate consisting galvanised steel base, verticle type mounted on 15 No's polymer insulators and steel frame, non ferrous knife and spring loaded contacts, arcing horns complete with dropout fuse element assembly, operating rod of GI pipe, medium grade, 20 mm dia (without joint) of suitable size and locking arrangement, connections, mild steel frame with PG clamps and sleeves etc required for current rating 400 amps capacity all as specified and directed.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-55 (11m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC including dismantling of old type of poles any length, complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm with suitable clamps made out of flat iron 50X6mm including nuts, bolts and washers, complete all as specified.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm, complete all as specified.
PVC insulated 3 core copper conductor cable of size 4 Sqmm, 1100 Volts grade with and including 25mm dia rigid PVC Conduit for connection of street Light from looping box to street light connector, complete all as specified
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 80mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
Un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed.
Laying only brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick , complete all as specified and directed.
Supply and fix in repair aluminum strip 25x3.15mm fixed on roof, pillars, wall etc. including porcelain isolator having not less than 50mm height with screws and saddles and placed at an interval not less than 50cm in such a manner that strip should not touch the wall/roof/pole surface etc. for roof conductors and down conductors above roof/wall/pole/ complete , fixed in repair complete all as specified.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of reinforced cement concrete M-15, reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 32X6 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 30 of tender doucments.
SATISH AND CO
SAINI AND SAINI BUILDERS
kailu construction co
TRIVENI CONSTRUCTIONS
B S Ranbir and Co
Shree Balaji Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .