Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.9 L+₹70,775 (3.90%)Rejected-AOC NORTH BEYPORE CALICUT 15 KERALA | KOZHIKODE | KERALA | 612906 | L2 | Rejected-AOC L2 | |
| 3 | L3₹19.1 L+₹99,749 (5.50%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹20.6 L+₹2.4 L (13.4%)Rejected-Finance ALANGAD P O KOTTAPURAM ALUVA 683511 | ALUVA | ERNAKULAM | KERALA | 683511 | L4 | Rejected-Finance L4 | |
| 5 | L5₹21.0 L+₹2.8 L (15.5%)Rejected-AOC SOBHA ELECTRIC CHANGANASERY KOTTAYAM | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
13 Jan 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical)
Executive Engineer (Electrical) Office of the Executive Engineer Electrical Electrical Division Engg Department University of Calicut Calicut University P O Malappuram District Kerala 673635
Electrification for new building of Calicut University Teacher Education Centre , Kallai, Kozhikode
2020_UoC_403297_1
D3/E-Tender No.12/2020-21
Open Tender
Electrical Works
Item Rate
60 days
University of Calicut
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,800
Yes
₹50,000
Yes
25 Feb 2021
30 Dec 2020
18 Jan 2021
30 Dec 2020
13 Jan 2021
30 Dec 2020
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A. (1.10.1)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B. (1.10.2)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C. (1.10.3)
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (1.11)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch. (1.24.2)
Wiring plug point along with wiring of light point including supply fixing 5A flush type modular switch and 3 pin plug socket in combined position.(Combined Plug). (od237431/2019_2020)
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. (1.38)
Supply,installation,testing and commissioning of Gong bell 300 mm. (od242267/2019_2020)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required - 20 mm. (1.21.1)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2x1.5 sq.mm + 1x1.5 sq.mm earth wire. (1.14.1)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (1.14.2)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. (1.14.3)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire. (1.14.4)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire. (1.14.7)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 4 X 4 sq. mm + 2 X 4 sq. mm earth wire. (1.14.8)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 4 X 6 sq. mm + 2 X 6 sq. mm earth wire. (1.14.9)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required - 3 X 1.5 sq.mm . (1.17.3)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. - 3 x 2.5 sq. mm. (1.17.12)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required - 6 x 2.5 sq. mm. (1.17.15)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required - 3 x 4 sq. mm. (1.17.21)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm. (1.17.24)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (1.26)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mm X 75mm). (1.27.1)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 15/16 amp switch. (1.24.3)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentia lbuildings).(1.31)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (1.32)
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess,including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). (1.56)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 3 pin 5/6 amp socket outlet. (1.24.4)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 6 pin 15/16 amp socket outlet. (1.24.5)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required. (1.44)
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored. (1.48)
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. (90.4.1)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (1.25)
Supplying and fixing PVC batten/ angle holder including connection etc. as required.(1.58)
supplying 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C. (od237432/2019_ 2020)
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. (90.4.8)
Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep. (1.50.1)
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden block including connection etc as required. (1.33)
Supply and laying 20 mm Corrugated PVC flexible conduit. (od237433/2019_2020)
Supply and laying 16/0.20 mm 3 core round copper conductor flex wire. (od237434/2019_2020)
supplying 25 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE. (od237435 / 2019_ 2020)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required -4 X 25 sq. mm (28mm). (9.1.34)
Supplying 16 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE. (od237436/ 2019_ 2020)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm). (9.1.33)
Supplying 10 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE. (od237437/ 2019_ 2020)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm). (9.1.32)
Supplying 4 sqmm 4 core PVC /XLPE insulated armoured cable with copper conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPE. (od237438/ 2019_2020)
Supplying 6 sqmm 4 core PVC /XLPE insulated armoured cable with copper conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLP. (od237439/2019_2020)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing masonry open duct as required.Upto 35 sq. mm. (7.6.1)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle). (7.7.1)
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. (2.16)
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts DP MCB Isolator complete with connections, testing and commissioning etc. as required. (od237450/2019_2020)
Supplying and fixing FP sheet steel enclosure on surface/ recess along with 40 amps 415 volts 4 pole Isolator complete with connections, testing and commissioning etc. as required. (od237451/2019_2020)
Supplying and installing 3Nos. of 300A Kit Kat Fuse unit (Lug type)using suitable size metal box , clamps, bolts ,nuts neutral link etc complete on existing LT post and making end termination of suitable UG cablewith aluminium lings on fuse side and winding on OH line. (od39699/2020_2021)
supplying one number of 185 sqmm 3.5 core PVC /XLPE insulated cable with aluminium conductor for working Voltages up to and including 1100 volts. conforming IS 1584/part I/1988 for PVC IS 7098 part I for XPLE. (od39700 /2020_2021)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp). (7.7.3)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp). (7.8.3)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 185 sq. mm (57mm). (9.1.27)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (5.4)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. (5.14)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing asrequired. (5.17)
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. (Dimension of pit shall be minimum of 2.5m * 0.6m*0.6m). (od237452/2019_2020)
Providing and fixing 10 SWG copper wire on surface or in recess for loop earthing as required. (od237453/ 2019_ 2020)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43). (90.11.1.14).
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43). (90.11.1.15)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator 12 way, Double door. (2.3.3)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/ Isolator - 16 way, Double door. (2.3.4)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43). (90.11.1.11)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole. (2.10.1)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole. (2.10.4)
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.(2.11)
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps. (2.12.1)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 amps. (2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps. (2.13.2)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps. (2.13.3)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrentcircuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps. (2.14.1)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 amps. (2.15.2)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required - 63 amps. (2.15.3)
Supplying 10W LED Bulkhead light Fitting. (od237455/ 2019_2020)
Erection of wall bracket / ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, Complete with all accessories including connection etc. as required. (1.35)
Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factorgreater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer). (90.15.4.3)
Supply and installation of crown shaped post tap lantern in soothing opal finished made up of polycarbonate pin type gate lamp with 20W LED lamp. (od49311/ 2020_ 2021)
Supply,installation,testing and commissioning of 36W, 240V, 2 * 2 Square type LED recces mounting light fitting on the existing false ceiling grid. od237457/ 2019_ 2020)
Supply, Installation ,testing and commissioning of 18W Square type LED (210*210 mm) fittings in the existing false ceiling. (od14459/2020_2021)
Supply,installation,testing and commissioning of 400 mm AC sweep oscillating type wall mounting fan with suitable clamp and bolt. (od237458/2019_2020)
Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/ 0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture. (90.3.20.3)
Supplying, fixing and commissioning of Surface mounting 36W white 2x2 LED luminaire,white powder coated CRCA housing with high power LED, Aluminium front frame with flat white light transmission acrylic cover. (od14463/2020_2021)
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame). (90.14.1.2)
Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. (90.14.2.1)
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board. (90.14.3.3)
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board. (90.14.5)
Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required. (90.14.6)
Supply and providing copper earth bus in the panel board. (90.14.7)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation, sand cushioning, protective covering andrefilling the trench etc as required.Upto 35 sq. mm. (7.1.1)
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Reducer" (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts suspended etc as required. 225 mm width X 50 mm depth X 1.6 mm thickness. (od49193/2020_2021)
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Tee"(Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts suspended etc as required. 225 mm width X 50 mm depth X 1.6 mm thickness. (od49194/2020_2021)
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bend"(Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts suspended etc as required. 225 mm width X 50 mm depth X 1.6 mm thickness. (od49195/2020_2021)
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable trays(Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts suspended etc as required. 225 mm width X 50 mm depth X 1.6 mm thickness. (od49196/2020_2021)
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Cross member" (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts suspended etc as required. 225 mm width X 50 mm depth X 1.6 mm thickness. (od49200/2020_2021)
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Reducer" (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts suspended etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness. (od49202/2020_2021)
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Cross member" (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts suspended etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness. (od49203/2020_2021)
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Tee" (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts suspended etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness. (od49204/2020_2021)
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bend"(Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts suspended etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness. (od49205/2020_2021)
Supplying and installing following size of perforated Hot dipped Galvanized Iron cable trays (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness. (od49206/ 2020_ 2021)
Supplying and installing incoming and outgoing MCCBs with thermal magnetic release having adjustable OL & SC and of suitable rated ultimate short circuit breaking capacity (Icu = 36kA) with Rotary handle , fixing 3Nos. RYB pilot lamps with toggle switch, MFmeter V,A, PF etc. base mount 3 phase energy meter with suitable CT 1) 1No.250A 4 pole MCCB as incomer 2) 7 Nos.63 /100A 3 pole MCCB (As outgoing) in the existing panel. (od36707 /2020_2021)
Supplying 1200 mm sweep- 5 star rated Ceiling fan, complete with 300mm down rod, canopies, shackles and blades working on 230/240V single phase A/C. (od237459/2019_2020)
gopakumar.kv
DINESAN.K,ELEKTRA ENGINEERING ASSOCIATES
M P SUBASH
AJESH K K
ASIF ELECTRICAL WORKS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_573461.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .