Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC NORTH BEYPORE CALICUT 15 KERALA | KOZHIKODE | KERALA | 612906 | L1 | Accepted-AOC Single tender approved by EE |
Tender Value
Refer Docs
EMD Value
₹18,696
Closing Date
5 Oct 2024, 6:00 pmClosed
Assistant Executive Engineer
O/o the Assistant Executive Engineer, PWD Electrical Sub Division, Kozhikode
Beautification work near Childrens park starting from Old NH Feroke- Interlocking/Drainage work-General Civil Work-Electrification-General Electrical Work
2024_PWD_690579_2
PWD/BLDG/TR/7851/2024
Open Tender
Electrical Works
Percentage
90 days
Kozhikode
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,650
₹18,696
19 Nov 2024
28 Sept 2024
7 Oct 2024
28 Sept 2024
5 Oct 2024
28 Sept 2024
Amount
Electrification
OD127914/2024-2025:Supply Conveyance, installation, testing and commissioning of 30W LED decorative luminaire Colour Temperature 3000-5700 K with IP 65 protection and IK09 impact resistance with power factor greater than 0.95 at full load, internal surge protection 4 KV, Spun & Extruded Aluminum body Powder coated finish, Convex type clear acrylic diffuser complete with THD less than 10%, power factor greater than 0.95,duly wired up for use on 240 V AC supply.With MS decorative pole of 4270mm height with single arm ,foundation bolts etc as required.( LED luminaire Make K-LITE code 5187 A11 Karona Fort Mini , DecorativePole K-LITE code 2011-427-G35-SA DRIVEWAY ORNA FLORUS Series or Techno commercial equivalent approved by engineer in charge)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD126277/2024-2025:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position and binding all complete.
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD125426/2024-2025:Supplying and fixing 24Hours Digital Time Switch for operating ON-OFF function in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. (L&T make Digital Time switch 2 module cat no 67DDT0 or Techno Commercial equivalent approved by engineer in charge)
OD126272/2024-2025:Supplying and fixing following rating modular type AC contactor in the existing MCB DB/Enclosure complete with giving connections, testing and commissioning etc. as required. 40 A, 2NO ( L&T make or Techno commercial equivalent approved by engineer in charge)
OD125425/2024-2025:Supplying and fixing following rating miniature type double pole AC change over switch with centre OFF in the existing MCB DB/Enclosure complete with connections, testing and commissioning etc. as required. 25 A, 2 pole, 2 way ( L&T make or Techno commercial equivalent approved by engineer in charge.)
OD125424/2024-2025:Supply and fixing following rating Surge Protection Devices (1P+N) ,Conforms to IEC 61643-11, Type 1+2(Protection against direct and indirect lightning surges) , Maximum Discharge Current - Imax up to 50 kA in existing MCB DB/ cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (L&T make or Techno commercial equivalent approved by engineer in charge.)
1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
OD127167/2024-2025:Providing and fixing following capacity DP / 2P disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp DP /2P(SDFU)
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
OD127985/2024-2025:Supply and providing 25x3mm brass nut and bolt etc. as required
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
OD127169/2024-2025:Supply and fixing 32 A Fuse base with HRC fuse link in the existing meter board and giving connections etc.
OD127960/2024-2025:Supply and fixing 32A, 2 way neutral link mounted on DMC/ SMC base in the existing box and giving connections etc. as required
OD127168/2024-2025:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision
OD126273/2024-2025:Supply and installation of CO2 type fire extinguisher of 2 Kg. Capacity with stored pressure type complete with installation brackets with ISI mark
OD126276/2024-2025:Supply and installation of CO2 type fire extinguisher of 4.5 Kg. Capacity with stored pressure type complete with installation brackets with ISI mark
OD126275/2024-2025:Supply and installation of ABC type fire extinguisher of 5 Kg. Capacity with stored pressure type complete with installation brackets with ISI mark
OD126274/2024-2025:Painting letters or figures with enamel paint as identification mark to SB, DB, panel board etc. as required 2.50 cm, 4 cm or 5 cm height
Bidder Name
gopakumar.kv
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1079312.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .