Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC 39 BASANT VIHAR RAKKAR COLONY DISTT UNA HP 174303 | UNA | HIMACHAL PRADESH | 174303 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹27.6 L+₹1.5 L (5.65%)Rejected-Finance NIL | L2 | Rejected-Finance Second Lowest | |
| 3 | L3₹28.6 L+₹2.5 L (9.57%)Rejected-Finance SCO NO 281 2ND FLOOR SECTOR 32 D CHANDIGARH 160031 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160031 | L3 | Rejected-Finance Highest |
Tender Value
Refer Docs
EMD Value
₹72,950
Closing Date
17 Feb 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE
Shimla
SOP to newly constructed Advocate General Building at High Court Shimla near New Chamber of High Court under ESD Chotta Shimla
2021_HPSEB_43868_1
DB-Tenders/No-11(SOP Advocate General Building)/20
Open Tender
Supply and Erection
Turn-key
120 days
As per NIT
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,360
Sr. Executive Engineer, Electrical Division No II
₹72,950
9 Apr 2021
1 Feb 2021
20 Feb 2021
1 Feb 2021
17 Feb 2021
4 Feb 2021
45 days
Amount
Design, Manufacture, Supply, Erection, Testing & Commissioning in supervision of OEM of 11/0.433kV 400kVA, Three Phase, indoor dry type transformer with Off Load Tap Changer with (+) 5% to (-) 7.5% in steps of 2.5% having cable and boxes on HV side suitable for 3x185mm2 XLPE cable of 11KV grade and 2000Amp and LV side complete with all accessories and flanges required for for connections confirming to IS-11171 and IEC-60076-11 as per specification complete in all respect. The scope is including Plinth/ iron Structure as per OEM design, complete in all rescept as per the direction of Engineer incharge.complete in all rescept as per the direction of Engineer incharge. Make:ABB/BHEL/CGL/C&S/ SCHNEIDER/GE(ALSTOM)/SIEMENS/Voltamp/Kirlosker/L&T
Design, Manufacture, Supply, Erection, Testing & Commissioning in supervison of approved OEM make, 12kV 630 Amps 21KA for 3 Sec. SF6 insulated, BIL 38 KV/95 KV peak, both side extensible, indoor duty 5 way, manually operated Ring main unit ( 2 LBS & 3 VCB) consisting of copper busbar in SF6 insulated . Suitable CT 100-50/1 A with microprocessor based numerical over current relay (IDMTL + Inst.) for Protection to be provided with VCB Feeder with HT metering of 0.5 accuracy Class CT 100-50/1 Amps, PT 11KV 110 volt, meter compatible to HPSEB TOD tariff make Secure/L&T/HPL)with right angle boot Touch Proof termination Kits. The RMU design should support site replaceable HT cable bushing. The scope is including Plinth/Angle iron Stand as per OEM design complete in all rescept as per the direction of Engineer incharge.Make:-ABB/SCHNEIDER/ GE(ALSTOM)/ SIEMENS/CGL/C&S
Design, Manufacture, Supply, Erection, Testing & Commissioning of LT distribution panel board having 01 Nos. incomer of ACB 800 Amps 50KA , 01 nos. outgoing 630Amps, 35KA and 01 nos.400Amps, 35KA on LV side with aluminium busbar of rating 1000A with adequate space for 3.5 core armoured PVC 500sq.mm LT cable. The scope will include all plinth/angle iron works required for erection of Panel and size of panel should be as per site requirement and complete in all respect as per the direction of Engineer incharge. Make:C&S/L&T/Schneider/ Crompton Greaves/Schneider / Siemens
Supply, Erection, Testing & Commissioning of Copper Earthing for neutral of transformer with copper earth plate 600mm x 600 mm x3 thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr. long etc with charcoal/coke and salt as required to complete the job including copper strip of size 40x 6mm from equipment to earthing complete in all rescept as per the direction of Engineer incharge. complete in all respect
Supply, Erection, Testing & Commissioning of GI Earthing for body earthing HT Panel & Transformer with GI plate 600mm x 600 mm x3 thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr. long etc with charcoal/coke and salt as required to complete the job including GI strip of size 40x 6mm from equipment to earthing complete in all respect as per the direction of Engineer incharge.
Prov. & fixing fire retardant/ extinguishing Electrical Insulated Synthetic Mat of size 3.00mm thick+10% confirming to IS; 15652 :2006 & metering requirements of SI; 3043, IS 5216 ( Part 1, 2 &3), IS 8437 and 479 Pub-1, Testing of Breakdown Strength,tensile/Elongation ageing properties, insulation resistance effects of acid alkaline diesel and transformer oil, leakage current test, fire test etc. having minimum width of 1000mm + 20mm. All allied material such as PU- resin, chemi bond (hardner) Aspl. PVC adhesive, liquid primer etc. suitable for all voltage not exceeding 66KV system with HT Trolley movment complete in all rescept as per the direction of Engineer incharge.
Erection, Installation, testing & commissioning of 11kV XLPE 3x95mm2 armoured cable complete in all rescept as per the direction of Engineer incharge.
Supplying, Installation, testing & commissioning of Heat Shrinkable End Termination Kit suitable for 11kV XLPE 3x95mm2 armoured cable as per ISI specifications and latest ammendment thereof CPRI tested complete in all rescept as per the direction of Engineer incharge. Make:3M/Denson/Rychem/Frontech.
Laying of 1.1KV grade LT armored cable PVC 3.5 core 500mm2 and providing Thimble complete in all rescept as per the direction of Engineer incharge.
Supplying, Installation & testing Fire extinguisher 6kg CO2 Cylinders as per ISI specifications and latest ammendment thereof complete in all rescept as per the direction of Engineer incharge.
Supplying, Installation & testing Fire extinguisher 9 kg AFFF Mechanical Foam Cylinder as per ISI specifications and latest ammendment thereof complete in all rescept as per the direction of Engineer incharge.
Nivesh Engineering and Power Solutions
ECS ENGINEERING CHD PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .