Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 CrAccepted-AOC | ₹26.5 Cr | L1 | Accepted-AOC L1 |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹25 L
Closing Date
23 Jul 2020, 6:00 pmClosed
Manager
KERALA STATE ELECTRONICS DEVELOPMENT CORPORATION LIMITED (A Government of Kerala Undertaking) 102-A, Poonam Chambers, Dr. A.B. Road, Worli, Mumbai - 400018
Supply, Installation, Testing and Commissioning of Video Surveillance system in connection with implementation of Integrated Security system (ISS) on Western Railways
2020_KSEDC_371833_1
KSEDC/KMO/Mumbai/2020-21/004
Open Tender
Hardware
90 days
Mumbai
Please refer Tender documents.
12 documents required · 12 mandatory
₹25,000
Yes
online
₹25 L
Yes
2 Nov 2020
15 Jul 2020
25 Jul 2020
15 Jul 2020
23 Jul 2020
16 Jul 2020
CCMS MAF
Supply, Installation, Testing & Commissioning of Fixed Box type/Bullet type, Full HD, IP colour Camera including Varifocal Lens, housing, mount and all other accessories as per RRDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. (Quantity of Fixed Box type & Bullet type cameras will be decided by the site in-charge as per site requirement.) MAF HIKVISION
Supply, Installation, Testing & Commissioning of P/T/Z (Pan/Tilt/Zoom), Full HD, IP Colour Camera including Lens and all other accessories as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. MAF HIKVISION
Supply, Installation, Testing & Commissioning of Fixed Box Type/Bullet Type, 4K UHD, IP Colour Camera including Varifocal Lens, housing, mount and all other accessories as per RDSO Specification RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. (Quantity of Fixed Box type & Bullet type cameras will be decided by the site in-charge as per site requirement.) MAF HIKVISION
Supply, Installation, Testing & Commissioning of Video Management & Video Recording Software with License as per RDSO Specification RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. (1. Per camera License means Video Recording & Video Management (Viewing) at multiple locations such as Station, RPF Post & S&T Command Center by same license.It should have provision of Viewing the system over Intranet Nerwork. 2. Customised Mobile App to be developed by the Contractor as per requirement & RDSO Specification)(Per unit means per Camera) MAF HIKVISION
Supply, Installation, Testing & Commissioning of Video Analytics Software with License as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. (Per camera License means Video analytic at multiple locations such as Station, RPF Post & S&T Command Center by same license. It should have provision of Video Analytics over Intranet Network)(Per unit means per Camera)
Supply, Installation, Testing & Commissioning of Face Recognition Software with License as per RRDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. (Per camera License means FRS at RPF Post. By same license, Face Recognition can be possible at multiple locations such as Station & S&T Command Center. It should have provision of Face Recognition over Intranet Network).(Per unit means per Camera)
Supply of Server Hardware / NVR (which will be used for Video Management & Video Recording and support minimum 64 cameras without adding any accessories ) with minimum usable storage of 32 TB and all other required accessories to make the system operational, as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. MAF HIKVISION
Installation, Testing & Commissioning of Server / NVR (which will be used for Video Management & Video Recording) with required accessories as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. MAF
Supply of Server Hardware for Video Analytics and all other required accessories to make the system operational, as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. MAF Huawei
Installation, Testing & Commissioning of Server Hardware for Video Analytics and all other required accessories to make the system operational, as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4.
Supply of Server Hardware for Face recognition and all other required accessories to make the system operational, as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. (The Sever should be CPU/GPU based. If Server is CPU based the Graphic card to be supplied by the contractor to fulfill FRS requirement.. One Server should support minimum 10 nos. of 4K UHD cameras for face recognition. If nos. of Servers required more to support minimum 10 numbers of cameras then additional Servers to be supplied by the the contractor free of cost). MAF Huawei
Installation, Testing & Commissioning of Server Hardware for Face recognition and all other required accessories to make the system operational, as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4.
Supply, Installation, Testing & Commissioning of External Storage Device with minimum usable storage of 240TB and all other required accessories to make the system operational, as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. (a. Minimum 6 numbers of Air-Conditioned racks to be provided by the contractor to accomodate 18 nos. of External Storage Device. If more number of racks are required, additional racks to be provided by the Contractor free of cost. b. Each Storage Device should support the enhancement of minimum usable storage of 320TB by adding only Hard Disks. c. Centralized NMS (Hardware & Software ) for the CCTV System and Entire Networking System is covered under this item. d. Furniture for the command center is also covered under this item. e. Necessary Hardware & Software required for storage, Managment & viewinng of Video data of Cameras shall be supplied by the contractor under this item if required.) MAF Huawei
Supply of PC Workstation including Software with License as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. MAF Lenovo
Installation, Testing & Commissioning of PC Workstation including Software with License as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. MAF Lenovo
laying of Permanently Lubricated HDPE Duct in trenches/GI pipe/RCC pipes including jointing and levelling using couplers and sealing the section etc as per site requirement and as per technical specification of Chapter-4.
Installation, Testing & Commissioning of Large Format Display Monitor as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. MAF LG
Supply, Installation, Testing & Commissioning of Layer-3 Switch as per RDSO Specification RDSO/SPN/TC/83/2014, Revision 1.0, Amendment 1.0 (with latest revision /amendments) and as per technical specification of Chapter-4. (L3 Switch shall have 24 nos. of 10/100/1000 Mbps Base-T ports equipped & 8 nos. modular ports supporting 10 Gbps. These modular ports shall be equipped with 02 nos of 10 Gbps SFPs & 06 nos of 1 Gbps SFPs). MAF Huawei
Supply, Installation, Testing & Commissioning of Field Switch as per RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. MAF 50% from Huawei, 50% fromTejus, Bangalore
Supply, Installation, Testing & Commissioning of 24 Port Layer-2 Switch as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. MAF Huawei
Supply, Installation, Testing & Commissioning of Aggregate Switch as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. MAF Huawei
Supply, Installation, Testing & Commissioning of Core Switch as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4. MAF Huawei
Supply & installation of 9 U Rack with all accessories as per technical specification of Chapter-4 MAF Dlink
Supply & installation of 42U Rack (Server Rack) with all accessories as per technical specification of Chapter-4 MAF Valrack
Supply of STP CAT 6 cable as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4, including laying in conduit pipe. (In this Item, conduit pipe with required accessories will be supplied by the contractor)
Supply of Power cable as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment, including laying and as per technical specification of Chapter-4, including laying. (Wherever required, Power cable to be laid in conduit pipe/flexible pipe/casing capping then these items will be supplied by the contractor).
Supply of 24 Fibre armoured underground Optic Fiber Cable as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4, including laying. (Wherever required, OFC cable to be laid in conduit pipe/flexible pipe/casing capping then these items will be supplied by the contractor)
Supply of Aerial Armoured Optical Fiber Cable , 6 Core , Single Mode as per technical specification of Chapter-4, including laying in conduit pipe. (In this Item, conduit pipe with required accessories will be supplied by the contractor) MAF Dlink
Supply, Installation, Testing & Commissioning of 10 KVA UPS with minimum battery backup of 30 minutes including suitable Rack as per technical specification of Chapter-4. ( Battery & UPS should be rack mountable. Battery back-up should be of minimum 30 Minutes at full load of 10KVA)
Supply, Installation, Testing & Commissioning of Panic Button as per RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest amendment and as per technical specification of Chapter-4, including suitable protection & fixing arrangement.
Supply & Installation of 12-port Fiber Optic Patch panel (LIU) allongwith all accessories as per technical specification of Chapter-4, MAF Dlink
Supply & Installation of 24-port Fiber Optic Patch Panel (LIU) along with all accessories as per technical specification of Chapter-4 MAF Dlink
Supply of Fiber Optic Duplex Patch cord as per technical specification of Chapter-4. MAF Dlink
Supply and installation of 150mm width x 50mm depth x 1.6mm thick size perforated GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with GI suspenders and as per technical specification of Chapter-4. (where support is not available , same will be provided by the contractor). MAF RDSO
Supply & installation of Earthing arrangement for Telecom equipments as per RDSO Specification RDSO/SPN/197/2016 Version 1.0 or latest and as per technical specification of Chapter-4.
Supply of Permanently Lubricated HDPE Duct with all accessories as per RDSO Specification RDSO/SPN/TC/45/2013 Rev. 2.0 Amendment 1 & 2 or latest amendment and as per technical specification of Chapter-4.
Laying of Permanently Lubricated HDPE Duct in trenches/GI pipe/RCC pipes including jointing and levelling using couplers and sealing the section etc as per site requirement and as per technical specification of Chapter-4. MAF RDSO
Supply and laying of 6 Meter long GI pipe of 100 mm dia, Grade-B with ISI mark as per technical specification of Chapter-4.
Supply and laying of Double Walled Corrugated HDPE Duct with all accessories as per RDSO/SPN/204/2011/ Ver.1.1 and Amendment 1 or latest amendment and as per technical specification of Chapter-4.
Excavation of trench 1.2 meter deep , 300 mm wide at the bottom along main line in all type of soil (Except rocky areas), asphalted road etc, including clearing of bushes , trees, teporary construction, bailing out water from the trench etc. and refilling of the trench by excavated soil and ramming after laying of the required quantity of cable as per specification, as per instruction of engineer in-charge and as per technical specification of Chapter-4. It also includes supply & provision of RCC cable route marker at 30 meter interval and also at every change of route.
Excavation of trench under rail track (1000 mm deep x 300 mm wide) & back filling after laying cable. Ramming of the soil in the trench and consolidation of the soil as well as the disposal of the soil if any, including supply & provision of RCC cable route markers at both the ends of crossing and as directed by engineer in-charge.This includes all required protective works to suite the site conditions and as per technical specification of Chapter-4.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid